Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.5 LAccepted-AOC | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹28.3 L+₹5.6 L (24.8%)Rejected-Finance | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹30.0 L+₹7.3 L (32.0%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L-3 | Rejected-Finance Being other than lowest | |
| 4 | L-4₹34.7 L+₹12.0 L (53.0%)Rejected-Finance | L-4 | Rejected-Finance Being other than lowest | |
| 5 | L-5₹35.2 L+₹12.5 L (55.0%)Rejected-Finance | L-5 | Rejected-Finance Being other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
26 Mar 2022, 5:00 pmClosed
GE (AF) TECH AREA AGRA
GE (AF) TECH AREA AGRA
REPAIR/ MAINT OF DG SET, AMF PANEL AT AF STN AGRA UNDER GE (AF) TECH AREA AGRA
2022_MES_499433_3
8200-1386/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) TECH AREA AGRA
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) TECH AREA AGRA
₹70,000
Yes
21 Apr 2022
10 Mar 2022
28 Mar 2022
10 Mar 2022
26 Mar 2022
14 Mar 2022
10 Mar 2022 - 12 Mar 2022
Amount
M&L for servicing of upto 40 KVA DG set including replacement Engine oil and all type of filters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling and topping of new engine oil complete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule 'A'. (b) Each servicing of DG Set will be required after 6 months or 250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop or rep of relative company
M&L for servicing 50 KVA to 82.5 KVA DG set including replacement Engine oil and all type of filters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling and topping of new engine oil complete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule 'A'. (b) Each servicing of DG Set will be required after 6 months or 250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop or rep of relative company
M&L for servicing of 100 to 180 KVA DG set including replacement Engine oil and all type of filters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling and topping of new engine oil complete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule 'A'. (b) Each servicing of DG Set will be required after 6 months or 250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop or rep of relative company
M&L for servicing of 200 to 320 KVA KVA DG set including replacement Engine oil and all type of filters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling and topping of new engine oil complete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule 'A'. (b) Each servicing of DG Set will be required after 6 months or 250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop or rep of relative company
M&L for servicing of 400 KVA DG set including replacement Engine oil and all type of filters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling and topping of new engine oil complete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule 'A'. (b) Each servicing of DG Set will be required after 6 months or 250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop or rep of relative company
M&L for servicing of 500 KVA KVA DG setincluding replacement Engine oil and all type of filters as per manufacturers manual.Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling and topping of new engine oil complete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule 'A'. (b) Each servicing of DG Set will be required after 6 months or 250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop or rep of relative company
Supply and filling of Engine oil 15 W / 40 complete all as specified and directed. Make :Castrol / HP / Bharat Petrolium / Valvoline
Supply and filling of coolant suitable for radiater of DG sets complete all as specified and directed. Make: HP/TVS / Valvoline / KIRLOSKAR
S&F in renewal of battery terminal brass(heavy duty)with nuts & bolts for battery (as per sample) complete all as specified and directed.
Supply and filling distilled water suitable for DG set complete all as specified and directed.
Disconnecting of self starter 12/24 volts DC, dismantling and repairing with renewal of bendex pinion , rewinding of armature , bushes set , rewinding of field coil assembly, reassembling complete including testing of the self starter for capacity upto 82.5 KVA DG Set Complete all as specified and directed.
Disconnecting of self starter 12/24 volts DC, dismantling and repairing with renewal of bendex pinion, rewinding of armature, bushes set,rewinding of field coil assembly, reassembling complete including testing of the self starter for capacity from 100 to 160 KVA DG Set Complete all as specified and directed.
Disconnecting of self starter 24 volts DC, dismantling and repairing with renewal of bendex pinion,rewinding of armature, bushes set, rewinding of field coil assembly, reassembling complete including testing of the self starter for capacity from 200 to 320 KVA DG Set Complete all as specified and directed.
Disconnecting of self starter 24 volts DC, dismantling and repairing with renewal of bendex pinion,rewinding of armature, bushes set, rewinding of field coil assembly, reassembling complete including testing of the self starter for capacity from 400 to 500 KVA DG Set Complete all as specified and directed.
Taking down old repairable Radiator by opening nut/bolt from foundation and loading/unloading and transportation to local market for checking, testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process. Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator with loading/unloading and transportation & including refixing to its old position with proper accuracy and correct situation for Capacity from 20 KVA to 40 KVA DG sets including renewal of nut/bolt, hose pipe sets with clamps and testing complete all as specified and directed.
Taking down old repairable Radiator by opening nut/bolt from foundation and loading/unloading and transportation to local market for checking, testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process. Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator with loading/unloading and transportation & including refixing to its old position with proper accuracy and correct situation for Capacity 62.5 to 82.5 KVA DG sets including renewal of nut/bolt, hose pipe sets with clamps and testing complete all as specified and directed.
Taking down old repairable Radiator by opening nut/bolt from foundation and loading/unloading and transportation to local market for checking, testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process. Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator with loading/unloading and transportation & including refixing to its old position with proper accuracy and correct situation for Capacity from 100 KVA to 160 KVA DG sets including renewal of nut/bolt, hose pipe sets with clamps and testing complete all as specified and directed.
Taking down old repairable Radiator by opening nut/bolt from foundation and loading/unloading and transportation to local market for checking, testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process. Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator with loading/unloading and transportation & including refixing to its old position with proper accuracy and correct situation for Capacity from 200 KVA to 320 KVA DG sets including renewal of nut/bolt, hose pipe sets with clamps and testing complete all as specified and directed.
Taking down old repairable Radiator by opening nut/bolt from foundation and loading/unloading and transportation to local market for checking, testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process. Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator with loading/unloading and transportation & including refixing to its old position with proper accuracy and correct situation for Capacity from 400 KVA to 500 KVA DG sets including renewal of nut/bolt, hose pipe sets with clamps and testing complete all as specified and directed.
Taking down old Radiator by opening nut/bolt from foundation and supply, installing and testing new Radiator with proper accuracy and correct situation for Capacity from upto 200 KVA DG sets including nut/bolt, hose pipe sets with clamps and testing complete all as specified and directed.
M & L for disconnection & taking down of cooler assembly from foundation of DG set engine including repairing, soldering & cleaning of Radiator assembly complete by acid process and refixing to its old position with proper accuracy and correct situation including transportation charges for 200 to 320 KVA DG set complete all as specified and directed.
M & L for disconnection, taking down and repairing of alternator DC from DG set engine with rewinding of armature ,renewal of carbon brushes, renewal of bearings, rewinding of field coil assembly, renewal of connection plate, reassembling and refixing to DG set engine after necessary repair for following sizes complete all as specified and directed:-
M & L for repairing of automatic battery charger of 12 Volt / 24 Volts including rewinding of transformer unit and renewal of diode plates, rectifier plates, auto cut mosfet circuit , fuses etc. and testing for following sizes complete all as specified and directed:-
M & L for repairing of canopy doors complete with renewal of following itmes including denting and necessary welding of doors complete all as specified and directed:-
M.S. Door lock of size 5.75" x 4.5" and of 08 levers
M.S.door handle of 150mm size
M.S. Butt hinges of 100 mm size
M & L in renewal of flywheel ring with proper setting and alignment for 100 to 160 KVA DG set complete all as specified and directed.
M & L for painting of DG set, panels, diesel tank, silencer and painting complete with two coats of synthetic enamel paint over one coat of primer and writing SM.MES No, Make and capacity with super enamel paint including scrapping of old paint for Capacity from 100 KVA to 160 KVA DG Set complete all as specified and directed.
M & L for painting of 20 KVA & 30 KVA DG Set with trolly frame including panels, diesel tank with two coats of super sythentic enamel paint over one coat of primer complete all as specified and directed.
M & L for renewal of Magnetic Pickup suitable for 100 KVA & 200 KVA DG set complete all as specified and directed. Make:- Cummins / KIRLOSKAR / GREAVES COTTON
S&F in renewal for Shut down valve solenoid suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal for Thermostat of suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal for Diaphramg coupling for upto 62.5 KVA DG set capacity complete all as specified and directed.
S&F in renewal for Hose Sil D100 X 90 for upto 200 KVA DG set capacity complete all as specified and directed.
S&F in renewal for Engine water temperature meter suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal for Engine RPM gauge meter for DG set complete all as specified and directed.
S&F in renewal for Switch temperature (Water Safety) suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal for Switch pressure ( Oil Safety ) suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal for Separator fuel water suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal for Air Cleaner Assembly for upto 62.5 KVA DG set capacity complete all as specified and directed.
S&F in renewal for Battery lead of 25 Sqmm, 2mtr long suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal for Feed pump suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal for Injector assembly for 62.5 KVA to 200 KVA DG set complete all as specified and directed.
S&F in renewal for V Belt / Fan belt suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal for Diesel pipe suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal for Fuel pipe (525 mm long) for all capacities of DG set complete all as specified and directed.
S&F in renewal for Lube Oil Pressure gauge-24 Volt /12 Volt, 60 mm suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal for Fuel filter cartridge duplex type suitable for up to 82.5 KVA DG set complete all as specified and directed.
S&F in renewal for Gear pump drive 100 KVA to 200 KVA DG set complete all as specified and directed.
S&F in renewal for Tube Lub Oil transfer suitable for all capacities of DG set complete all as specified and directed
S&F in renewal for Tube fuel bypass suitable for all capacities of DG set complete all as specified and directed
S&F in renewal for Hose Flexible suitable for for all capacities of DG set complete all as specified and directed
M&L for disconnecting, dismantling and overhauling of fuel injector pump of DG set capacity 15 KVA to 82.5 KVA including overhauling, calibration and testing at admissible pressure properly complete all as specified and directed. Note : FIP shall be calibrated by authorized workshop contractor has to submit documentary evidence for over hauling carried out from authorized workshop
Supply & fixing in renewal of Nozzle for 15 KVA to 82.5 KVA DG set complete all as specified and directed.
Supply & fixing in renewal of F.I.P. Elements for 15 KVA to 82.5 KVA DG set complete all as specified and directed.
Supply & fixing in renewal of Delivery valve for 15 KVA to 82.5 KVA DG set complete all as specified and directed.
M&L for disconnecting, dismantling and overhauling of fuel injector pump of DG set for capacity 100 KVA to 200 KVA including repair, overhauling, calibration, testing complete and refixing to its original position properly complete all as specified and directed. Note : FIP shall be calibrated by authorized workshop contractor has to submit documentary evidence for over hauling carried out from authorized workshop
Supply & fixing in renewal of Nozzle & Holder Assembly for 100 KVA to 200 KVA complete all as specified and directed.
Supply & fixing in renewal of Gear Drive Injection pump for 100 KVA to 200 KVA complete all as specified and directed.
Supply & fixing in renewal of Gasket injection pump mount for 100 KVA to 200 KVA complete all as specified and directed.
Supply & fixing in renewal of A.V.R suitable for 20 KVA to 200 KVA DG set complete all as specified and directed. Make:- KIRLOSKAR / AE / NATIONAL.
M & L for dismantling of defective water pump assembly by disconnecting of hose pipe connections, fanbelt, radiator connection and supply and fixing of new water pump assembly suitable for DG set capacity for 40 KVA to 100 KVA including renewal of u/s hose pipes, fan belt, nut/bolts etc complete all as specified and directed. Make:-- KIRLOSKAR / Cummins / GREAVES COTTON
Supply & fixing in renewal of solenoid stopper ( solenoid fuel pump ) for FIP pump for 40 KVA to 200 KVA DG set complete all as specified and directed. Make :--Cummins / Kirloskar .
Supply & fixing in renewal of fully automatic battery charger input 230V AC SMPS based) and out put 24V DC for 24 volt battery complete all as specified and directed. Make :- KIRLOSKAR / ELECT INDIA / Cummins / UNITEK INDIA .
Supply & fixing in renewal of fully automatic battery charger input 230V AC SMPS based) and out put 12V DC for 12 volt battery complete all as specified and directed. Make :- KIRLOSKAR / ELECT INDIA / Cummins / UNITEK INDIA
Supply & fixing in renewal of Battery- 12 Volts,180 AH for DG set complete all as specified and directed. Make: EXIDE / AMARON / or equillvant with 18 month replacement warranty
Checking of AMF panel & DG set for detecting any kind of fault in AMF panel & DG set and attending the fault immediately at any time round the clock and carry out certain repair as per site requirement and checking of AMF panel and DG set for power suply from DG set through AMF panel and replacing of worn out parts of AMF panel & DG set by expert engineer complete all as specified and directed. Note: (a) Replacement of worn out parts of AMF panel/DG set shall be measured and paid separately under items of schedule 'A'. (b) Charges for detecting the fault in AMF Panel/electric system/DG set are included in the quoted item rate.
M & L in renewal of flywheel ring ( 3246713 ) with proper setting and alignment from 400 to 500 KVA DG set complete all as specified and directed.
M & L in renewal for Flywheel ring from DG set and renewal of new flywheel ring ( 3166605 ) with proper setting and alignment from 320 KVA DG set complete all as specified and directed.
M & L for disconnecting, dismantling and overhauling with repairing of PT pump complete with renewal of drive accessories, Plunger Air fuel control, Oil seal , Gasket set fuel pump etc including machinery work for 500 KVA DG SET complete all as specified and directed (Location 50 Sqn). Note : PT pump shall be calibrated by authorized workshop contractor has to submit documentary evidence for over hauling carried out from authorized workshop
M & L for shifting of trolly mounted DG set up to 250 KVA from one location to another location (with in 05 kilometer) complete with dismentling of cable connection, earth strip including transportation with using necessary chain pulley & HYDRAULIC jack etc. with connection of cable earth strip and other etc. at new location complete all as specified and directed.
S & F in renewal of Genset Controller Panel suitable upto 125 KVA make and model as per site or directed by Enginer -in- charge
S & F in renewal of Genset Controller Panel suitable above 125 to 320 KVA make and model as per site or directed by Enginer -in- charge
S & F in renewal of Genset Controller Panel sutiable upto 400 Kva to 500 KVA make and model as per site or directed by Enginer -in- charge
Supply & fixing new in replacement of Digital Voltmeter 96 Sqmm, 0 to 500 volts. Make: AE/ HPL / National OR Equivalent
Supply & fixing new in replacement of Digital Ampere meter, 96 Sqmm, 0-200 Amps . Make: AE/ HPL / National OR Equivalent
Supply & fixing new in replacement of Digital Frequency meter, 96 Sqmm . Make: AE/ National OR Equivalent
Supply & fixing new in replacement of Analog Voltmeter 96 Sqmm, (0 to 30 volts). Make: AE/National OR Equivalent
Supply & fixing new in replacement of Indicater lamp with holder set of three colours of R,Y & B (LED type) suitable for DC/AC supply.
Supply & fixing new in replacement of bus bar of suitable length,width & thickness with suitable size of porcelain insulator duly insulated with coloured insulation tape R,Y,B and neutral Black laminated with respective colour code
Supply & fixing new in replacement of Relay-24 VDC/ 12 VDC / 220 VAC / 240 VAC for AMF panel of DG set. Make: CUMMINS( AX1012821 ) / OMRON / SALZER / PLA OR Equivalent .
Supply & fixing new in replacement of Contactor- 3/4 Pole,150 Amps/ 140 AMPS for 62.5 KVA DG Set AMF panel with replacement of lugs and checking of all connections etc. Make:- LEGRAND ( 4162 66 ) / L &T / SCHNEIDER .
Supply & fixing new in replacement of Contactor- 3/4 Pole, 225 Amp/ 200 Amp for 125 KVA DG set AMF panel with replacement of lugs and checking of all connections etc. Make:- LEGRAND ( 4162 96 ) / L &T / SCHNEIDER
Supply & fixing new in replacement of Contactor of 4 Pole, 250 Amps for AMF PANEL of DG Set with replacement of cable lugs and checking of all connections etc. Make:-SCHNEIDER ( LC1F1504 ) / L &T / LEGRAND.
Supply & fixing new in replacement of Contactor of 4 Pole, 400 Amps, for AMF PANEL of DG Set with replacement of lugs and checking of all connections etc. Make:- SCHNEIDER ( LC1F3304 ) / L &T / LEGRAND.
Supply & fixing new in replacement of Contactor- 4 Pole, 700 / 600 Amps for AMF PANEL of 500 KVA DG set capacity with replacement of lugs and checking of all connections etc. Make:- SCHNEIDER ( LC1F5004 ) / LEGRAND / L &T
Supply & fixing new in replacement of Spare Contact Kit for Contactor-250 Amps suitable for 100 KVA to 125 KVA DG set. Make:- L & T ( CS94084) / SCHNEIDER / LEGRAND.
Supply & fixing new in replacement of Spare Contact Kit for Contactor-400 Amps suitable for 110 KVA to 200 KVA DG set AMF panel. Make:- L & T ( CS94297 ) / SCHNEIDER / LEGRAND.
Supply & fixing new in replacement of Spare Contact Kit for Contactor-600 Amps suitable for 320 KVA DG SET. Make:- L & T ( CS94299 ) / SCHNEIDER / LEGRAND.
Supply & fixing new in replacement of MCCB, 400 Amp, 4 pole, 70 KA , 415 Volt including taking out existing connections, cable lugs etc all as specified and directed. Make:-L & T ( CM94153OOOOAG ) / Legrand / SCHNEIDER .
Supply & fixing new in replacement of MCCB, 630 Amp, 4 pole, 70 KA , 415 Volt including taking out existing and connections, cable lugs etc all as specified and directed. Make:- L & T ( CM94179OOOOAG ) / Legrand / SCHNEIDER .
Supply & fixing new in replacement of MCCB, 800 Amp, 4 pole, 70 KA , 415 Volt including taking out existing and connections, cable lugs etc all as specified and directed. Make:- L & T( CM96115OOOOAG ) / Legrand / SCHNEIDER
Supply & fixing new in replacement of DIN Type Fuse Links Type HN (160 amps ) suitable for 100 KVA DG set AMF panel. Make: L & T ( SF94231 ) / STANDARD OR Equivalent
Supply & fixing new in replacement of DIN Type Fuse Links Type HN ( 100 amps ) suitable for 63 KVA DG set AMF panel. Make: L & T ( SF94129 ) / STANDARD OR Equivalent
Supply & fixing new in replacement of Fuse Bases ( HN-Size 2 & 3 ) suitable for 63 KVA DG set AMF panel. Make: L & T ( SK91051 ) / STANDARD OR Equivalent
Supply & fixing new in replacement of Self Engine Stop Relay Device for 63 KVA to 180 KVA DG set AMF panel . Make: Automation Electronics / Elect India
Supply & fixing new in replacement of AMF Controller device for Auto/ Manual function for 200 KVA to 500 KVA DG set. Make: Automation Electronics / ELECT INDIA OR Equivalent
Supply & fixing new in replacement of Solenoid stopper ( Solenoid Fuel Pump ) upto 125 KVA DG set . Make:--Cummins ( 3928160 ) / Kirloskar / or Eqivalent
M & L for dismantling of defective water pump assembly by disconnecting of hose pipe connections, fanbelt, radiator connection. Supply and fixing of new water pump assembly suitable for DG set capacity for 125 KVA to 200 KVA including replacement of u/s hose pipes, fan belt, nut/bolts etc. Make:-- Kirloskar ( KL6.176.05.0.00 ) / Cummins or Eqivalent.
Supply & fixing new in replacement of Electronic Timer, auxilary supply-240 VAC/24 VDC for 125 KVA to 200 KVA DG set. Make: AE/ EAPL / MINILEC OR Equivalent
Supply & fixing new in replacement of Undervolt/overvolt relay-ON/OFF delay time (1 to 15 sec ),sensing supply 415 Volt for 63 KVA to 400 KVA DG set. Make-AE/ PIC / MINILEC OR Equivalent
Supply & fixing new in replacement of Changeover switch (Open Execution, Front operated) of 630 Amps, 4 Pole, 415 V, 50 Hz. Make: HPL ( BP06304POAV ) / HAVELLS / STANDARD.
Supply & fixing new in replacement of Changeover switch (Open Execution, Front operated) of 400 Amps, 4 Pole, 415 V, 50 Hz. Make: HPL ( BP04004POAV ) / HAVELLS / STANDARD.
Supply & fixing new in replacement of OFF-Load Changeover switch (Side Handle) of 400 Amps, 4 Pole, 415 V, 50 Hz. Make: HAVELLS / HPL / STANDARD.
Supply & fixing new in replacement of Rectifier Assembly for 40 KVA to 160 KVA DG set. Make: KIRLOSKAR ( KV280108000) / CUMMINS OR Equivalent .
Supply & fixing new in replacement of Set of Forword and Reverse Diode for 40 KVA to 160 KVA DG set Make: KIRLOSKAR ( F681539000 ) / CUMMINS OR Equivalent .
Supply & fixing new in replacement of Rocker housing assembly suitable for 160 KVA.. MAKE: CUMMINS ( 3044788 ) OR EQUIVALENT.
Supply & fixing new in replacement of Three Phase Multifunction Digital meter . Make: Automation Electronics / HPL / National OR Equivalent
Supply & fixing new in replacement of AMF Relay Box for Auto/ Manual function including voltage monityor system and fully auto and manual system for 63 KVA to 110 KVA DG set. Make: AE/ ELECT INDIA OR Equivalent
Supply & fixing new in replacement of STARTER ( SELF STARTER ) for 200 KVA DG set. Make: KIRLOSKAR ( KL6.140.12.0.00 ) / AUTOLEK / LUCAS.
Supply & fixing new in replacement of Tube injector fuel supply for 100 KVA to 200 KVA DG set. Make: CUMMINS ( 3964706 ) / KIRLOSKAR
Supply & fixing new in replacement of CONTROL GOVERNOR ( MECHANICAL GOVERNOR ) for 160 KVA DG set. Make: CUMMINS ( 3037359 ). .
M & L for repairing of PT pump complete with replacement of drive accessories, plunger and barrel, weight/courier,oil sheets etc including machinery work for 125 KVA to 160 KVA DG set complete all as specified and directed. Note : PT pump shall be calibrated by authorized workshop contractor has to submit documentary evidence for over hauling carried out from authorized workshop
Supply & fixing drive accessory(3005131) for repairing of PT pump for 125 KVA to 160 KVA complete all as specified and directed.
Supply & fixing plunger Air fuel control (3021676) for repairing of PT pump for 125 KVA to 160 KVA complete all as specified and directed.
Supply & fixing shaft governor weight (3006718) for repairing of PT pump for 125 KVA to 160 KVA complete all as specified and directed.
Supply & fixing oil seal (3006738) for repairing of PT pump for 125 KVA to 160 KVA complete all as specified and directed.
Supply & fixing gasket set fuel pump (3010242) for repairing of PT pump for 125 KVA to 160 KVA complete all as specified and directed.
M & L for dismantling of turbo charger for capacity 100 KVA to 200 KVA DG set engine including repair, overhauling, testing complete and fixing to its original position properly complete all as specified and directed:--
S&F in repair Kit Turbo (KIT3801101) for repairing of Turbo charger for capacity from 100 to 200 KVA DG Set complete all as specified and directed.
S&F in repair shaft (01320360) for repairing of Turbo charger for capacity from 100 to 200 KVA DG Set complete all as specified and directed.
S&F in repair sleeve turbocharger (216802) for repairing of Turbo charger for capacity from 100 to 200 KVA DG Set complete all as specified and directed.
S&F in repair support turbocharger (216804) for repairing of Turbo charger for capacity from 100 to 200 KVA DG Set complete all as specified and directed.
M & L for dismantling and replacement of Injector assembly (3239796) for 62.5 KVA to 200 KVA DG set complete all as specified and directed.
Taking out alternator of 125 KVA to 200 KVA DG sets of any make, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
Field coil rewinding of alternator of 125 KVA to 200 KVA capacity DG sets of any make, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
Taking out alternator of 62.5 KVA to 100 KVA DG sets of any make, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
Field coil rewinding of alternator of 62.5 KVA to 100 KVA capacity DG sets of any make, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
Taking out alternator of 20 KVA to 50 KVA DG sets of any make, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
Field coil rewinding of alternator of 20 KVA to 50 KVA capacity DG sets of any make, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
S&F MCCB 4 Pole Thermal adjustable breaker type complete all as specified and directed of following capacity Make : Make:- LEGRAND / L &T / SCHNEIDER
63 AMP, 36 KA
125 AMP, 36 KA
160 AMP, 36 KA
250 AMP, 36 KA
250 AMP, 36 KA
M/s KCL Engines and Machines
MUKTA AND COMPANY
Balaji Associate
M/S KRISHNA KAVYANSH BROTHERS
AUTOMATION AND SWITCHGEAR PANELS
Preetpowercontrol
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .