Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-Finance 210 A RASHBEHARI AVENUE KOLKATA 700029 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L1 | Accepted-Finance lowest bidder | |
| 2 | L2₹26.4 L+₹1.3 L (5.35%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700 028 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L2 | Rejected-Finance bidder is not L1 | |
| 3 | L3₹27.0 L+₹1.9 L (7.45%)Rejected-Finance 133 GARFA MAIN ROAD KOLKATA 700 078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L3 | Rejected-Finance bidder is not L1 | |
| 4 | L4₹27.1 L+₹1.9 L (7.76%)Rejected-Finance | L4 | Rejected-Finance bidder is not L1 | |
| 5 | L5₹27.9 L+₹2.8 L (11.3%)Rejected-Finance 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L5 | Rejected-Finance bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹67,415
Closing Date
25 Aug 2025, 11:00 amClosed
EE-l CKHED PWD
Central Kolkata Health Electrical Division P-12, C.I.T Road(1st floor) Kolkata- 700014
Augmentation and SITC of Electrical LT Panel for Enhanced Current Handling capacity and Safety at RRMB Building, Calcutta National Medical College and Hospital, Kolkata.(Electrical Work)
2025_WBPWD_887115_1
WBPWD/EE-I/CKHED/eNIT32/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
NMCH
Please refer Tender documents.
3 documents required · 3 mandatory
₹67,415
Central Kolkata Health Electrical Division
1 Sept 2025
4 Aug 2025
27 Aug 2025
4 Aug 2025
25 Aug 2025
11 Aug 2025
8 Aug 2025
Amount
Supplying and fixing 630 A,415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.[make:L&T(SK90492) /legrand /Siemens]
Supply and fixing of Copper Spreader Links or Extension Copper Bars to enab-le double cable entry and termination for a 630A Switch Fuse Unit (SFU) and a 630A Changeover switch, as per directed by EIC . including S&F Nut, Bolt, and Washer assemblies to securely fasten the spreader links or extension bars.
SITC of suitable size of Copper bus -bar chamber with 16 SWG sheet steel enclouser,on flat iron/angle iron frame on wall with nuts bolts etc having current capacity of following -
4 bars ,1000Amps capacity.[Dimension of Cu. Bars-{4 x (2x 80x5)mm} ]
4 bars ,315Amps capacity,[Dimension of Cu. Bars-{4 x 40x5mm} ]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsh-eathed copper wire (Brand: KEI/Havells/ Polycab/RR) in suitable size Aluminum flexible pipe ) incl. necy. fittings(Make: Precision) as required .
a)Cu ,Wire (4 X 185 SQ mm)
Finishing the wire ends of following Cu ,Wire by crimping method incl. supplying and fixing sCU socket (Dowels make), tapes, anticorrosive paste & jointing materials.
b)4 X 185 sqmm Cu ,Wire
Supplying and fixing 630 A, sheet steel (16SWG) cable end box on TPN SFU/ Changeover switch enclosure with nuts bolts etc incl. powder coated painting
Supplying and fixing 630A,415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc.[make: L&T (CO46300OSOO) / ABB/Siemens]
Supplying and fixing 415V,250A, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc.[make: L&T ]
Supply, installation, testing, and commissioning of an indoor-type LT Panel box, designed for IP-43 protection, rated at 415V, 1000A BBC, 50Hz.The panel construction will utilize 2mm thick CRCA steel/MS plate sheets reinforced on a 75X50X6mm angle iron frame, featuring front and rear openable hinged doors with door handle arrangements, including a locking arrangement.
The foundation for the panel will be constructed using cement concrete, ens-uring a robust and approved structure. This foundation will be sitespecific and will incorporate proper sizing of iron channels and angles to enhance stability and compliance with the EIC requirements. Additionally, the founda-tion, having a suitable size for the installation of the above-mentioned panel, is included in the scope of work. The panel will be securely mounted either in the floor or on the wall, as per the site requirements and in accordance with the EIC specifications. This mounting arrangement ensures optimal stability and accessibility for the efficient operation and maintenance of the LT Panel.
The LT Panel box will include interconnections between 415V Four Pole SFU. Heavy copper solid bars with necessary socketing will support the bus-bars, and FRP/DMC insulators will be used for insulation.Inside the panel, the interconnection between the main bus bar and all SFUs will be established using appropriate size copper bars and suitable spreader links. Wire connec-tions are not permissible for this purpose. To further enhance the reliabil-ity and efficiency of the panel, suitable size copper bars and spreader links will be provided for the outgoing terminals of all SFUs . This design feature aims to facilitate the connection of outgoing cable terminals, ensuring a robust and seamless electrical distribution system.Panel drawing detailling with busbar and interconnection cu strip arrangemant with cable entry and foundation details must be approved by EIC.
The panel dimensions will comply with the respective Bureau of Indian Standards (BIS) and site working space requirements. It will be painted powder coating with two coats of red oxide as a primer, followed by a final coat with synthetic light grey /Siemens grey shade as per IS 631.
A) Incoming: (i) 415V, 630 Amp TPN Cubical type Switch Disconnector Fuse Unit suitable for DIN Fuse-link. – (L&T) –1No. (ii) 415V,1000 Amp BUS-BAR of [4 x (2 x 80x5) mm] [Elecrtrolyte copper Bar on heavy duty porcelain insulator with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete as required. multi-color tapping & necy drilled holes.-1 Set. B) Outgoing: (i) 415V, 250 Amp TPN Cubical type Switch Disconnector Fuse Unit suitable for DIN Fuse-link. (L&T) –3No. (ii) 415V, 160 Amp TPN Cubical type Switch Disconnector Fuse Unit suitable for DIN Fuse-link. (L&T) – 8No
D) Miscellaneous: (1) S&F Danger board of size 1'x1' on the front face of LT Panel - - - 1 No. (2) All switches(SFU etc.) required, shall be fixed by S.S. nuts & bolts on angle/flat iron frame base as per requirement & direction of E.I.C (3) All separate compartments for SFUs etc. must be marked with Name Plates (replaceble type,because we can change the nameplate as required), according to their Outgoing or Incoming connections, as per direction of E.I.This labeling practice ensures clear identification of where each component is intended to be placed within the electrical system. (4) There must be cable entry box of appropriate size and of same material & guage as that of the main panel, at up-side & down-side of the panel. (5) Control circuit to be protected by MCB and control wiring to by 1.5 sq. mm.(min.) copper wire. (6) Panel Board must have indication lamps forR-Y-B indication. (7) Panel must have provision for cable entry (for Incomer and Outgoing cable).
Supply and fixing double door Vertical-TPN-MCB DB housing for MCCB incomer and TP-MCBs as outgoing with IP-43 protection, concealed in wall after cutting the wall or on flat iron/angle iron frame on wall with nuts bolts etc & mending good the damages to original finish & necy. wall matching paint as required or total establishment on angle iron frame on wall incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment require.also S&F Suitable size of copper spreader link for MCCB incoming cable connection . LEGRAND EKINOX : Upto 250A,Enclosure (607724)-12-way
Supply and fixing 415V/240V, of following rating "C"-curve MCBs (10kA)/ MCCBs(35kA)(Legrand Make) on din rail in existing VTPNDB/TPN-DBs/SPN-DBs and necy. connection as required. i)160A(35kA)FP MCCB.
ii)63A,TP,(10kA),MCB.
Supply & Delivery only the following 1.1 KV grade PVC insulated A/Al. Cable as below: [Polycab/RR/Havells] i)4 core 240 sq mm.
ii). 4 core 120 sq mm.
Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages as per direction of EIC
Laying of cable above 4 core 90 sqmm and upto 4 core 300 sqmm on wall/ surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspe-nder,bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. (ii) With 25x25x3mm angle iron support 300x50x1.25mm (18SWG).
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. Above 150 sqmm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 80 mm dia
S & F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: i). 4 core 240sq mm.
ii). 4 core 120sq mm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. i).4 core 240 sqmm.
iii)4 core 120 sqmm.
Supplying and fixing 25mm PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20/ 25/35 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 4x126 /0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make:- Finolex/RR Kabel/PolyCab/ Gloster/ Havells/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points/5A 3 pin flush type plug socket with Piano Key type switch (Make:- Anchor/ Havells) fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/ Perspex (wall matching color) top cover 3 mm thick and incl. 175mm x100mm x 65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish.
On Board
Average run 6mtr
S&D of Twin LED Tube light fitting along with 2 nos. MAS LED (PC body) Tube 1200mm delivering minimum 100 lumen/watt [Make:- Philips, Batten Cat No.- TMC100 2xTLED 13-20w WH & Tube light Cat No.- 18W 865 T8 I – 2100lm or Crompton, Batten Cat. No.- IGP162 LT8-16 2 x T8 & Tube light Cat No.- LTB-20-865-(2)]
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener.
Supply & Fixing 240 V,2 nos. 5A, & 2 nos. 16A plug socket with separate 2 nos. 5 A & 2 nos. 16A Piano key type switch (both Anchor make),1 no. indicator & 20A switch type SP MCB(Havells make) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making neccy.connections as required.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil.
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. Long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. Long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. Below the ground level as below: a) By TATA-Medium GI pipe.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments body to earth busbar incl. S&F galvanised (Hot Dip) following sizes MS flat(TATA/ JINDAL/ JSW) on wall/ floorwith GI saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc. 40 mm x 6 mm galvanised (Hot Dip) MS flat .
Fixing only existing 415V,315A, TPN on load front operated Changeover swit-ch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc.
Disconnection and dismentling the existing LT panel,Changeover switch,BBC, board,wiring incl. filling the existing duct with sand& bricks along with sand cement work incl. mending good the damages as per instruction of EIC.
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
Electromech Engineers Co-Operative Society Ltd. (BID ID -6832459)
Prava Enterprise (BID ID -6871559)
Cons Engineers Co-operative Society Ltd. (BID ID -6869263)
S. A. ENTERPRISE (BID ID -6858973)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .