Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 303 MAHESH NANGIA 303 PRAGATI CHAMBERS RANJIT NAGAR COMMERCAIL COMPLEX RANJIT NAGAR COMMERCIAL COMPLEX | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹74 L
EMD Value
₹1.5 L
Closing Date
3 Jul 2023, 4:00 pmClosed
Executive Engineer TLMD-II, JKPTCL, Glad
Office of Executive Engineer TLMD-II, JKPTCL, Gladni Jammu
Replacement of old and worn out equipment such as isolators, current transformers and lightening arrestor etc in 220 KV yard at 710 MVA, 220/132/33 KV Grid station Gladni
2023_PDD_215347_1
TLMD-II/J/06 of 2023-24 Dated06-06-2023
Open Tender
Electrical Works
Turn-key
180 days
GLADNI JAMMU
AS PER NIT AND SBD
3 documents required · 3 mandatory
₹5,000
Executive Engineer TLMD-II, JKPTCL, Gladni Jammu
₹1.5 L
24 Jul 2023
9 Jun 2023
7 Jul 2023
10 Jun 2023
3 Jul 2023
11 Jun 2023
Amount
Design, Engineering. Manufacture,workshop testing, supply including packing and forwarded, transportation, delivery at site storage charges of;Main Equipment
Single phase, 50 c/s 245KV Current Transformers (2000-1600-1200/1-1-1-1-1 A or as per site specifications), 40KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA
Single Phase 50 c/s, outdoor metal oxide gapless type, 200KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
Single phase, 50 c/s 220KV Capacitor Voltage Transformers (220/√3) KV/(110/√3)V , One min power freq withstand 460KVrms
245kV, 50c/s , 1600 Amp, 40kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
245kV, 50c/s , 1600 Amp, 40kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self- supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns.
Cooling fans of 150 MVA ,220/132/33 KV Auto-transformer
Silica gel containers of varoius size/capacity along with fresh silica gel of 150 MVA,220/132 KV Auto transformer.
DISMANTLING OF EQUIPMENTS
Single phase, 50 c/s 245KV Current Transformers (2000-1600-1200/1-1-1-1-1 A or as per site specifications), 40KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA
Single Phase 50 c/s, outdoor metal oxide gapless type, 200KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
Single phase, 50 c/s 220KV Capacitor Voltage Transformers (220/√3) KV/(110/√3)V , One min power freq withstand 460KVrms
245kV, 50c/s , 1600 Amp, 40kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
245kV, 50c/s , 1600 Amp, 40kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self- supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns.
Replacement of old,unserviceable/non-working fans of 150 MVA ,220/132/33 KV Auto-transformer
Replacement of silica gel containers of varoius size/capacity along with fresh silica gel of 150 MVA,220/132 KV Auto transformer.
COUNTRY CONSTRUCTION
HITECH ERECTORS PVT. LTD.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .