Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance MIG SECTOR 25A P D NAGAR UNNAO | UNNAO | UNNAO | UTTAR PRADESH | Admitted-Finance |
Tender Value
₹11.4 L
EMD Value
₹12,000
Closing Date
26 Nov 2020, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC Mathura
132 KV S/S Aurangabad Mathura
Work of Reviving, Overhauling upgradation of existing Mulsifyre system installed at 220 KV S/S Chhata under ETD Mathura
2020_UPTCL_525449_1
ET-50/ETC(M)/20-21
Open Tender
Electrical Works
Lump-sum
90 days
Under ETC Mathura
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
EE ETD Mathura
₹12,000
18 Dec 2020
27 Oct 2020
27 Nov 2020
27 Oct 2020
26 Nov 2020
27 Oct 2020
120 days
Overhauling of Fire-Fighthin pumps engine driven/motor driven work includes dismantling of pumps, complete pump checkup, checking throughness of shaft and sleeves to eliminate any bend ness inspection of bearing clearance seal assembly, trial run of 40 min. Will be after completion of work at rated head and flow with rated current, supply of all consumable or non-consumable items. All T&p , man and matereal shall be proveded by contractor at own cost.
Overhauling of fire-fighting pumps motordriven jockey pump work includes dismantling of pumps complete pump checkup, checking throughness of shaft and sleeves to eliminate any bend ness, inspection of bearing clearnace, seal assembly, trial run of 40 min. Will be after completion of work at rated head and flow with rated currnet , supply of all consumable or non-consumable items. All T&P, man and material shall be provided by contractor at own cost.
Complete Serviceing and overhauling of 105 HP Kiloshker make Diesel make including replacement of engine Oil/Oil filter/belts/hose pipes and attending of leakage by replacing worn out pipe associated work required to complete the job satisfactorily.
Complete overhauling of installed ELGI/Ingersoll rand make air compressor, complete oiling greasing, cleaning of filter and replacement of defected air pressure switch, pressure gauge etc
Complete overhauling/reparing of gate valves work includes dismantling, cleaning, greasing attending any leakage and other work required to complete work satisfactorily. All T&P, man and material shall be provided by contractor at own cost.
Repairing of existing NRV along with servicing of flapper and cleaing of strainer along with dismantling and reinstalling of NRV
Spray painting on different sizes gate valves of water hydrant and emulsifier system including pump house with two coat of synthetic enamel paints after red oxide primer after cleaning of surface with wire brush or emery paper. Size of gate valve are below:-
250 NB Gate valve
150 NB Gate valve
100 NB Gate valve
80 NB Gate valve
50 NB Gate valve
Air vessel tank
250NB Pipe P.O. red oxide
150 NB Pipe P.O. red oxide
100 NB Pipe P.O. red oxide
80 NB Pipe P.O. red oxide
65 NB Pipe P.O. red oxide
50 NB Pipe P.O. red oxide
Cleaning of Emulsifier water storage tank having algae/biological growth on its wall and floor having capacity of tank 634Cu. Meter. All T&P, man and material shall be provided by contractor at own cost.
Repairing, servicing and maintenance of exiting foot valve along with replacement/servicing of flapper and cleaning of strainers along with dismantling and re-installing of foot valve of various size as per the detail below
Servicing and overhauling along with servicing of diaphragm with re-installation, testing and commissioning of quick operating flood deluge valve of 150NB, 100NB as per maximum working pressure of 10Kg/cm2
Servicing and overhauling along with servicing of diaphragm with re-installation, testing and commissioning of quick operating flood deluge valve of 150NB, 100NB as per maximum working pressure of 10Kg/cm2
Supply and laying of different size of GI Pipe above ground jindal/Tata/Apollo make "B" (Medium) Class for fire detection/Water pipe line as per specification (IS Code-1239) Complete with elbow, Tee Socket, redocer painting with Pre cost of Epoxy/equivalent primer finishing with 2cost po Red enamle finish.
Supply with laying of RCC hume pipe as per IS:458NP 3 Class, 1000 mm below the ground level of size 300 mm as per specification.
Supply & Installation of MS Pipe supports made of C section angle of size 25 x25x 50 mm suitable for different size of pipes with plinth above ground level 300 mm and below ground level 200 mm with cement conrse sand and concrete/brimk ballast as per specification in ratio1:2:4
Miscellaneous works and items like attending leakage/blockages, alarm gong, brass globe valves, back pressure valve, priming water tank and other works not included above work but are necessary for completion of the work by running the Mulsifire system on all Transformers in Auto mode.
Supply Installation of Single headed 63 mm hydrant post complete with all accessories
P&H Engineering
Puja And Sanu Enterprises
M/S M G SECURITY SYSTEMS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .