Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹29.4 L+₹6.0 L (25.8%)Rejected-Finance PB NO 809 ABERDEEN BAZAR PO ATLANTA POINT NEAR POLICE WIRELESS PORT BLAIR 744104 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744104 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹31.4 L+₹8.0 L (34.3%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹31.8 L+₹8.4 L (36.1%)Rejected-Finance 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L4 | Rejected-Finance Being other than lowest | |
| 5 | Rejected-Technical 10 11 PANDRI GOVIND NAGAR RAIPUR CHATTISHGARH 492001 | RAIPUR | CHHATTISGARH | 492001 | - | Rejected-Technical Not enlisted in requisite category |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
10 Sept 2022, 6:00 pmClosed
GE(I)866 EWS CARNICOBAR
GE(I)866 EWS CARNICOBAR C/O 99APO 913866
REPAIR / MAINTENANCE OF PUMPS AND WATER SUPPLY DISTRIBUTION LINES AT AF STN CARNICOBAR
2022_MES_546414_1
8609/E8
Open Tender
Civil Works
Item Rate
330 days
Area under GE(I)866 EWS CARNICOBAR
As per Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE(I)866EWS
₹56,000
Yes
7 Nov 2022
20 Aug 2022
15 Sept 2022
20 Aug 2022
10 Sept 2022
3 Sept 2022
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5mtr depth and getting it out in soft / loose soil including forming bottom surface to required level for laying of GI pipe lines complete all as specified and as directed .
Returning, filling in excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 15cm complete all as specified and as directed .
Removing surplus soil to a distance not exc 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed .
M & L for GI steel water tubing, medium grade, of following size with all necessary fittings( socket, bends, elbows, tees, short pieces, connector, caps, plugs & union, fixing clips etc) laid in trenches/ fixed to walls/ on floors including taking down of existing unserviceable pipes complete all as specified and directed by . Make : Tata / Jindal / Surya / Bansal
150 mm dia
100 mm bore
80mm dia
50mm dia
40mm dia
25mm dia
20mm dia
M&L for replacement of existing broken/ damaged PVC water tanks with PVC rotational moulded polyethylene water storage tanks double layer (cylindrical vertical with closed top) hoisted and fixed in position, connecting up pipes, securing access covers etc all as specified in SSR Pt-I and as directed by Engr in charge of following Capacity :- Make- Syntax / Rotex or equivalent
Capacity 2000 Ltr
Capacity 1000 Ltr
Capacity 500 Ltr
Supply and fix in repairs of Gun-metal, globe or gate valves, of following size with iron wheel head, screwed both ends for iron pipe and fixed including taking down of old worn out valve complete all as specified and as directed .
50 mm dia
40mm dia
25mm dia
20mm dia
15mm dia
Supply & fix in replacement of existing unsv ball type brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed with new socket if reqd at site. Complete all as specified & directed by Engr in Charge.
25mm dia
20mm dia
15mm dia
M&L for CI fittings such as bends (any type, radius and angle) tapers and type,(straight,bend,increaseing,decreasing or double socket etc) Tee pieces single branch 'Y' junctions, double branch, cross (all sockets/ flanged or socket and spigot/flanged) collars, caps and plugs etc including cutting of pipes at site for insertion of fitting complete as reqd at site up to 150mm bore .
M&L for Lead wool joint for making the leak proof joint , including necessary excavation, taking out water, and returning filling the excavated material after jointing matching to existing specification complete to the following size pipe line all as specified & directed by Engr in charge as under:-
80mm dia
100 mm dia
150mm dia
M&L for Run lead joint including taking out existing leakage run lead joint for making the leak proof joint , including necessary excavation, taking out water, and returning filling the excavated material after jointing, making good to the disturbed surface matching to existing specification complete to the following size pipe line all as specified & directed by Engr in charge as under:-
80mm dia
100 mm dia
150mm dia
M&L for UPVC pipe of pressure rating 10 Kg./cm square with all fittings such as elbow, bends, union, tee, reducing tee, adaptor, sockets plugs hose clips etc fixed complete to wall, ceiling or in trench etc of following dia:-
15 mm dia
20mm dia
25mm dia
32mm dia
40mm dia
50mm dia
Supply and fix in repairs of sluice valve class PN 1.6 with SS spindle, with operating wheel, rubber gasket & nut bolts with washer, including taking out existing UNSV valve any type and making good to the disturbed surface matching to existing specification etc complete all as specified & directed by Engr in Charge of following size:-
150mm dia
100mm dia
80mm dia
supply & fixing in replacement of PN 1.6 rated butterfly valves of integral moulded design, companion flanges, nuts, bolts, gaskets etc. with cast iron body, seat of black nitrile rubber, nylon coated S.G. iron disc, PTFE coated SS (AISI 410) shaft etc. as required, conforming to BS: 5155, MSS SP 67 & API 609, designed to fit without gaskets between mating flanges, suitable for flow in either direction and seal in both directions of following Dia as under:-
150mm dia
100mm dia
80mm dia
Material and labour for Plain cement concrete in foundations or pipe support or any other work type B2 (1:2:4) with 40 mm graded aggregate including any formwork if any required complete all as specified and as directed .
Supply and laying 3 layer PPR-R (Polypropylene random copolymer ) pipes of following outer dia SDR 7.4 (PN-16) UV stabilized antimicrobial union welded having thermal stability for hot and cold water including all PP-R plain & brass threaded polypropylene all type of fittings reqd at site and fixing including testing complete laid in trenches, in floor, on wall all as specified and directed by Engr-in-Charge .
50mm outer dia pipe
63 MM outer dia pipe
32 MM outer dia pipe
20 mm outer dia pipe
M & L for making connection of PPR distribution branch with PPR main size 16 to 40 mm by providing and fixing TEE incl cutting and making fusion joint complete all as required at side and directed by Engr in Charge.
M & L for making connection of PPR distribution branch with PPR main size 50 to 75 mm by providing and fixing TEE incl cutting and making fusion joint complete all as required at side and directed by Engr in Charge.
M & L for replacement of unsv PPR gate valve ( brass insert) as per site requirement of size 32 mm
M & L for replacement of unsv PPR gate valve ( brass insert) as per site requirement of size 63 mm
Material and Labour for Quarterly collecting water sample from Pump house & RO plant in carnicobar stn, packing it safely in sterilized bottles as required quantity and send it to approved Govt laboratory (TWAD - Tamil Nādu water and drainage board test lab or other approved labs) for testing of potable water/raw water as per IS 10500 with following parameters colour, odour, turbidity, conductivity, TDS, PH, alkalinity, hardness, calcium, magnesium, iron, manganese, ammonia, nitrate, nitrite, chloride, fluoride, sulphite, phosphate, silica, free chlorine, standard plate count ,total coliform , streptococcuc and special element tests complete all as specified and as directed. Note: Water sample of Well No-1,& 2 Ro No1 & 2 Total 04 Nos Sample to be collected at a time for testing & same shall be measured as one Job
M&L for replacement of fully automatic star delta DOL starter in sheet steel enclosure type MN 16 FASD with single phase protection feature suitable for motor 15 HP/11 KW, rating AC 3 duty, 415V,50 Hz 3 Ph having relay range 13-22A. Make- L&T Cat No SS94362 or equivalent in C&S / Legrand / Bharat
M&L for replacement of fully automatic star delta DOL starter in sheet steel enclosure type MU2FASD with single phase protection feature suitable for motor 30 HP/22.5 KW, rating AC 3 duty, 415V,50 Hz 3 Ph having relay range 20-33A. Make- L&T Cat No SS95892 or equivalent in C&S / Legrand/ Bharat
M&L for replacement of unsv sluice valve spindle & Gutka/guide nut of spindle of 80 to 200mm dia by opening the stuffing box of sluice valve and fixing with new SS spindle & gutka for operation of sluice valve including cleaning the internal surface of the valve for proper closing, fixing new gland packing, rubber gasket, worn out nut bolts & washer etc complete all as reqd at site & and directed by Engr in Charge.
M&L for carefully Cleaning of RCC over head water reservoir of capacity 75000 gallons at above 18 metre height staging after draining out the water from the tank including cleaning the complete inner surface of the tank, removal of silt, sludge, dirt deposited by scrapping with nylon brush, removing vegetation if any, washing internal surfaces including ceiling with clean water mixed with bleaching powder twice, and applying two coats of cement base paint to internal surface, scrapping out the rusted surface of ladder and apply two coat of synthetic enamel paint over one coat of red oxide paint , writing cleaning date/due date for cleaning with white enamel paint on black colour surface complete all as specified and as directed.
All as Sl item No 24.00 above, but 10,000 Gallons ( Height of reservoir more than 9.5 Mtr ) capacity complete all as specified and as directed.
Cleaning of RCC SWT'S reservoir 5000-10000 gallons of capacity after draining out the water from the tanks including removal of silt /sludge deposited in the tank with nylon brush and removing vegetation if any, washing the inner surface with bleaching powder including white washing the tank from inside and outer open surface above GL , including writing the cleaning date/due date for cleaning with white enamel paint on black colour surface complete all as directed.
M&L for carefully Cleaning of RCC / PVC overhead service tanks of bldgs. up to 500 to 1000 Ltr capacity, after draining out the water from the tank including removal of scale and dirt deposited in the tank with nylon brush and removing vegetation if any, washing the inner surfaces with bleaching powder, including writing date of cleaning and due date on the tanks with white synthetic enamel paint over a coat of black painted surface(Size 40 cm x50 cm) complete all as specified and as directed. Note: A proper register for cleaning of tank with date shall be maintained and same shall be submitted while claiming RAR / FB duly signed by Engineer-in-Charge and Contractor.
Description all as per item No 27.00 above, but above 2000 Ltr and up to 5000 Ltr capacity
M&L for rectification leakage in existing GI / CI water supply pipe in line 20 to 150mm dia in any position by excavation, taking out the water from excavated trench, rectifying the leakage in pipe line by inserting short piece of pipe, on site threading to pipe, replacement of socket, tee, bend, union etc as reqd at site as without taking out the pipe line, after rectification of leakage returning, filling and making disturbed surface matching to existing specification complete all as specified and as directed .
M&L for replacement of GI elbow 20 mm dia
M&L for replacement of GI tee 20 mm dia
M&L for replacement of GI union 20 mm dia
M&L for replacement of GI nipple 20 mm dia 50 mm long
M&L for replacement of GI elbow 25 mm dia any type
M&L for replacement of GI tee 25 mm dia equal or un equal
M&L for replacement of GI union 25 mm dia
M&L for replacement of GI nipple 25 mm dia 50 mm long
M&L for replacement of GI elbow 40 mm dia any type (equal or un equal)
M&L for replacement of GI tee 40 mm dia equal or un equal
M&L for replacement of GI union 40 mm dia
M&L for replacement of GI nipple 40 mm dia 50 mm long
M&L for replacement of GI elbow 50 mm dia equal or unequal
M&L for replacement of GI tee 50 mm dia equal or unequal
M&L for replacement of GI union 50 mm dia
M&L for replacement of GI nipple 50 mm dia 50 mm long
M&L for replacement of unsv GI bend 120 degree 50mm dia
M&L for carefully taking out the burnt electric induction motor/Monoblock pump set of following capacity, by dismantling from foundation, disconnecting incoming/outgoing elect cables etc, transportation to workshop (Port Blair) & back, opening the motor removing the burning winding with insulation, cleaning the inner surface , Applying new mica sheet for insulation & rewinding the motor with super enamel copper wire as per existing gauge & turn to maintain the existing speed of the motor, varnishing, heating etc, replacement of both end bearings as per existing size and refixing to its original position duly painted with best quality enamelled paint, testing complete all as specified & directed by Engr in Charge of following capacity:-
0.5 to 2 HP single phase induction motor
3HP to 5 HP Three phase induction motor
7.5 HP Three phase induction motor
15 HP Three phase induction motor
30 HP Three phase induction motor
M&L for taking down of centrifugal pump assembly of capacity 30HP from common base frame and transportation to workshop (Port Blair) for carry out the repair & back, opening of pump assembly , necessary lath work on shaft, , replacement of unsv parts, end bearing, bushing, worn out nut bolts, washer & gasket, PVC pipes etc of Pump set as reqd at site and making the pump set serviceable , refixing the pump set to its original position after successfully repair including painting with super enamel best quality paint complete all as specified & directed by Engr in Charge
Supply and fix 100 mm dia foot valve cast iron flanged as per IS 4038 standard internals leather/rubber washer including necessary gasket and taking down unserviceable foot valve all as directed
Supply and fix 200 mm dia foot valve cast iron flanged as per IS 4038 standard internals leather/rubber washer including necessary gasket and taking down unserviceable foot valve all as directed
M&L for replacement of Rubber Star Coupling as per existing size of 30 HP Pump set, including making proper alignment of Motor & pump set complete all as specified and as directed .
M&L for servicing of Elect Panel board including cleaning the panel checking all wires, contactors, MCB, MCCBs, starter, relay, tightening the loose connections, replacement of burnt wires, thimbles/lugs, connectors, LED indicators etc complete all as directed by Engr in Charge Major parts like MCCB, Contactors, relays shall be measured in respective items taken as supply only:- Make:- L&T or equivalent in C&S / Legrand
Power Contactor MNX 18
Power Contactor MNX 25
Power Contactor MNX 32
Power Contactor MNX 40
Add on Auxiliary contact block (MNX A-2 /MNX A-1/TA1-DN22)
Electronic Timers 110/240/360/415Volts 50 Hz for (3-10/ 9-30/36-120 Sec)
Contactors coil MNX/ML/MCX as per existing model & type
Thermal Over Load Relay (Auto/Manual reset) suitable for contractors (Relay range 2.5-t to 9-13 Amps )
Thermal Over Load Relay (Auto/Manual reset) suitable for contractors (Relay range 23-32 to 30-40 Amps )
MCB SP 6 to 32Amp C series 10 kA breaking capacity
MCB TPN 32 to 63A C series 10 kA breaking capacity
HRC Fuse Din type fuse link having 80/100 KA breaking capacity
M & L for replacement of monoset pump model no mini force II Booster pump of Crompton single phase 0.5 hp having suction delivery 25 x25 mm, head range 6 to 24 mtr, Discharge -2000 to 400 Lph ,2780 Rpm with pressure switch.
M&L for replacement of unsv open well submersible monoblock pump set of 1.5 HP suitable for working on single phase 230V, 50 HZ AC supply having SS body , IP 68,
M& L for cleaning, scraping, removing out old rusty paint of Pump house installed machinery, its connected pipe lines, control valves and electric panel by wire brush, emery paper, cleaning agents & Spray painting two coat of super enamelled paint over one coat of red oxide paint complete as per existing colour and marking complete all as reqd at site & directed by Engr-in Charge.
Replacement of unserviceable PVC weather proof cable and replacement with new PVC weather proof copper cable for size 3 core 4 sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
Replacement of unserviceable PVC weather proof cable and replacement with new PVC weather proof copper cable for size 3 core 2.5 sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
Supply only calcium Hypochlorite/ granule having 65 % residual chlorine for disinfection of water complete all as specified and as directed . Make - Declibac, RMCO, M/s Grasim Industries Ltd
Chandra Construction Enterprises
M/s Karbhagam Sales Agency
Ravi Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .