Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | ₹1.1 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.1 Cr+₹1.3 L (1.14%)Rejected-AOC | ₹1.1 Cr+₹1.3 L (1.14%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹1.1 Cr+₹3.0 L (2.74%)Rejected-AOC 66 102 ARUN JYOTHI MULLASSERY CANAL ROAD ERNAKULAM KOCHI 682 011 | KOCHI | ERNAKULAM | KERALA | 682011 | ₹1.1 Cr+₹3.0 L (2.74%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹1.2 Cr+₹6.3 L (5.73%)Rejected-AOC | ₹1.2 Cr+₹6.3 L (5.73%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹1.2 Cr+₹8.2 L (7.42%)Rejected-AOC | ₹1.2 Cr+₹8.2 L (7.42%) | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
22 Nov 2021, 6:00 pmClosed
CWE (NAVY) CHENNAI
Commander Works Engineers Navy Military Engineer Services INS Adyar Old Building Fort St George Rajaji Salai Chennai 600 009
SPECIAL REPAIRS TO REPLACEMENT OF HT OVER HEAD LINE TO UNDERGROUND CABLE FROM MRS TO MES COMPLEX (BSO STORE YARD) AT INS KATTABOMMAN UNDER GE TIRUNELVELI
2021_MES_456850_2
CA NO CWE/NAVY/TVL/81370/E8 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
TIRUNELVELI
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE TIRUNELVELI
₹2.2 L
Yes
6 Jan 2022
25 Oct 2021
23 Nov 2021
25 Oct 2021
22 Nov 2021
8 Nov 2021
26 Oct 2021 - 3 Nov 2021
Amount
Supply, laying and testing HT UG cable 3 core, 150 Sqmm, 11000 volts grade, XLPE cables, insulated and , armoured, multistranded, electric power cables (Heavy duty) with aluminium conductor ,laid in trenches, ducts complete all as specified and directed. Note: Excavation ,earthwork, sand filing and brick protection shall be measured and paid for seperately.
Supply, fixing HT 11 KV out door type triple pole, mechanically operated mounted on insulator with operating mechanism worked from ground level for current rating of 400 Amps all as specified and as directed.
Supply and erecting Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55, 11 metres long, all as specified and as directed.
Supply and Fix Lighting arresters expulsion type complete with all fitting, transmission class, discharge capacity 65 kilo amp 11KV, complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination ,heat shrink type joint ,complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV (Earthed) grade cable for indoor termination ,heat shrink type joint ,complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint ,complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
Supply and fix in repair cable route indicator for HT/LT UG cable made out of CI plate of size 200mm dia X 6mm thick showing voltage, cable type and MS angle iron of size 1200mm length 50X6mm with GI nut, bolt and washer MS angle grouted in PCC block 1:3:6 type C1 using 20mm graded stone aggregate of size 500X600X400 mm including excavation and earth work and painting to steel surfaces with two coats synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
Taking down old unserviceable cross arms bracing support, clamps all as specified and directed by Engineer-in-Charge
Taking down old unserviceable insulators any type all as specified and directed by Engineer-in-Charge
Taking down old unserviceable ACSR conductor and anticlimbling device all as specified and directed by Engineer-in-Charge
M&L for earthing complete with copper plate electrode 60cm×60cm× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip 20x3mm as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.5 connected to earthing test point,including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wiremesh ,funnel,lugs and charcoal,salt etc all as applicable including taking down old unserviceable earthing complete for taking into credit complete all as specified and as directed by the Engineer-in-Chargecomplete all as specified and as directed by the Engineer-in-Charge Note:-(i) The rates quoted is inclusive of 20x3mm copper strip earth conductor upto a length of 7.5m from the earth pit.
M&L for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised steel earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point,including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wiremesh ,funnel,lugs and charcoal,salt etc all as applicable including taking down old unserviceable earthing complete for taking into credit complete all as specified and as directed by the Engineer-in-Chargecomplete all as specified and as directed by the Engineer-in-Charge Note:-(i) The rates quoted is inclusive of 32x6mm GI strip earth conductor upto a length of 7.5m from the earth pit.
Supply and lay GI pipe light grade of size 100mm dia on trenches/fix on poles/walls/road crossing for cable protection.
Material and labour Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and as directed
Material and labour for Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green complete all as specified and directed.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in hard/dense soil, complete all as specified
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard rock/rocky stone, area stone trenches, break with help of heavy duty stone breaking machine for laying of cable complete all specified and as directed by Engineer-in-charge
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed
Removing excavated material (Rock) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed
Supply and spread fine river sand in trenches for cable cushioning on top and bottom of cable complete all as specified and directed. ( Note: 1. Only punned thickness of river sand shall be measured. 2. Riddled earth may be used in case of non availability of river sand.)
Supplying and laying reinforced precast concrete cable cover, class but class HV, Type 1, flat, size 300mmx l80mm x 40mm with ISO certified. The test certificate shall be submit by the contractor before approval complete all as specified and as directed
Material and labour for PCC 1:4:8 type D2 with 40mm cement concrete in foundations, filling and mass concrete complete all as specified and as directed
Material and labour cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed
Material and Labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20X3mm copper strip, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6mm dia galvanised iron , complete all as specified and as directed by the Engineer-in-Charge.
PHEJAYS AGENCIES
National Electric Co
Kurian And Varghese
eurekaenterprises
S KUMARAN
M/s.Rejoy Constructions
power links
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .