Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.7 LAccepted-Finance B 52 NIRALA NAGAR LUCKNOW | LUCKNOW | UTTAR PRADESH | ₹50.7 L | L1 | Accepted-Finance ok |
| 2 | Not Admitted-Finance | - | - | Not Admitted-Finance Not qualified for AOC |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical SAGARI CHHICHHORI AZAMGARH U P | AZAMGARH | UTTAR PRADESH | 223221 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | DESCON INFRASTRUCTURES PRIVATE LIMITED |
|---|---|---|---|---|
| 1.00Details of items | ||||
| 1.01 | 6M SPAN CANTILEVER STRUCTURE WITH ONE VERTICAL POST:
Supply & Erection of One No builtup cantilever structure 7.22 mtr Hight and 6.00 mtr span comprising of one vertical post of 7.22 Mtr. High made up of 300mm pipe & horizantal structure post of 6 Mtr. High made up of 300mm pipe member welded with (600mm X600 mmX20 mm) MS round plate at top and MS plate (600 X 600 X 20mm) at bottom of vertical pipe . Both 300mm pipe Flanged joints with 300mm pipe 610 mm Albow Type height as per Approved Design, Drawing with one coat of steel primer and two coats of synthetic enamel paint Also vertical pole should have the strip of AFP (Alluminium Flexible Sheeting) 0.3x 0.9 M Pasted and 2 Nos. FMM (Flexible Median Marker) fixing with Epoxy to provide median safety during night time or severe weather at the top of foundation after complete construction of RCC fondation of size 0.600 x 0.600 and 1.80 Mtr. deep for built up structure including earthwork in excavation, 150mm thick lean concrete in 1:3:6 cement, coarse sand and 40mm guage stone ballast, RCC with 1:1.5.:3 cement, coarse sand and 20mm stone grit including supply & courting of 32 mm Dia foundation bolts (600mm long) as per provision of structure including coast of reinforcement and shuttering as per direction of Engineerin- Charge, signage facia for both side of structure must be considered which comprises of ACP sheeting pasted with TYPE XI retro reflective sheeting as per IRC 67 : 2022. The signage shall include lettering and signs/ legends as Applicable. Back support frame shall be of 35x35x5mm MS angle. Add 2 per cent of cost of angle iron towards cost of drilling holes, nuts, bolts etc.The contractor need to submit calcoast test report for specular gloss & fungus resistance test as per IRC 67:2022 for clearance of final bill.All boards must be printed via OEM approved Digital printer self owned bu converter with MTS warranty of OEM as per the IRC 67-2022.. The reflective sheeting signage facia shall be covered with ultra voilet overlaminate transparant film 10 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from government test lab report of 3 year outdoor weathering test conducted in India condition test lab for the product offered shall be submitted by the contractor. All Boards must be manufactured via. digital Printing process as per IRC 67:2022, & bidder must submit outdoor weathring test report of digital printed board as per IRC along with bid. | 1 | Nos | 5,80,000 ₹5,80,000 Lowest |
| 1.02 | 12 TO 16.00 M SPAN OVER HEAD STRUCTURE WITH TWO VERTICAL POST: Supply and Erection of One No builtup overhead structure 12 to 16 m span comprising of two vertical post of 7.22 mtr. height made up of 350mm Vertical Pipe Post and horizontal Truss structure post of 250 mm N.B. medium class M.S. Pipe post as member. The post will be welded with (600x 600x10mm) M.S. round plate at top and (900x900x20mm) M.S. plate at bottom for of vertical pipe . Both 300 mm pipe are connected to truss by 610mm Albow Pipe as per approved Design. Drawing with one coat of steel primer and Two coats of synthetic enamel paint Also vertical pole should have the strip of AFP (Alluminium Flexible Sheeting) 0.3x 0.9 M Pasted and 2 Nos. FMM (Flexible Median Marker) fixing with Epoxy to provide median safety during night time or severe weather at the top of foundation after complete construction of RCC fondation of size 0.900 x 0.900 mm and 1800 MM. deep for built up overhead structure including earthwork in excavation, 100 mm thick lean concrete inl:1:2 cement, coarse sand and 20mm guage stone ballast, RCC with 1:1.5:3 cement, coarse sand and 20mm stone grit including supply & courting of 32 mm Dia foundation bolts (750 mm long) as per provision of structure including cost of reinforcement and shuttering as per direction of Engineer-in-Charge , signage facia for both side of structure must be considered which comprises of ACP sheeting pasted with TYPE XI retro reflective sheeting as per IRC 67 : 2022. The signage shall include lettering and signs/ legends as Applicable. Back support frame shall be of 35x35x5mm MS angle. Add 2 per cent of cost of angle iron towards cost of drilling holes, nuts, bolts etc.The contractor need to submit calcoast test report for specular gloss & fungus resistance test as per IRC 67:2022 for clearance of final bill.All boards must be printed via OEM approved Digital printer self owned bu converter with MTS warranty of OEM as per the IRC 67-2022.. The reflective sheeting signage facia shall be covered with ultra voilet overlaminate transparant film 10 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from government test lab report of 3 year outdoor weathering test conducted in India condition test lab for the product offered shall be submitted by the contractor. All Boards must be manufactured via. digital Printing process as per IRC 67:2022, & bidder must submit outdoor weathring test report of digital printed board as per IRC along with bid. | 1 | Nos | 14,95,500 ₹14,95,500 Lowest |
| 1.03 | 15 TO 25.00 M SPAN OVER HEAD STRUCTURE WITH THREE VERTICAL POST: Supply, fixing & erection of One No builtup Overhead Structure of 15.00M to 25.00M span comprising of three vertical posts 300 OD-7.50M height [One vertical post is made by combining the Two pipe 300 OD as per approved drawing}.The post will be welded with (600x 600x20mm) M.S. round plate at top and (600x1800x20mm) M.S. plate at bottom of vertical pipe.The Truss supported by the Vertical pipes will be made by combining the Two pipes of 300 dia. by 114 od 0.90m pipes and truss will be connected by the Vertical posts by 610 mm Albow .Also vertical pole should have the strip of AFP (Alluminium Flexible Sheeting) 0.3x 0.9 M Pasted on each vertical post and 2 Nos. FMM (Flexible Median Marker) fixing with Epoxy to provide median safety during night time or severe weather at the top of each foundation. This work includes design and construction the RCC foundation of size 0.800 x 2.0m and 2.10 Mtr. deep for built up structure including earthwork in excavation, 150mm thick lean concrete in 1:3:6 cement, coarse sand and 40mm guage stone ballast, RCC with 1:1.5.:3 cement, coarse sand and 20mm stone grit including supply & courting of 32 mm Dia foundation bolts (1000mm long) as per provision of structure including coast of reinforcement and shuttering as per direction of Engineerin- Charge, signage facia for both side of structure must be considered which comprises of ACP sheeting pasted with TYPE XI retro reflective sheeting as per IRC 67 : 2022. The signage shall include lettering and signs/ legends as Applicable. Back support frame shall be of 35x35x5mm MS angle. Add 2 per cent of cost of angle iron towards cost of drilling holes, nuts, bolts etc.The contractor need to submit calcoast test report for specular gloss & fungus resistance test as per IRC 67:2022 for clearance of final bill.All boards must be printed via OEM approved Digital printer self owned bu converter with MTS warranty of OEM as per the IRC 67-2022.. The reflective sheeting signage facia shall be covered with ultra voilet overlaminate transparant film 10 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from government test lab report of 3 year outdoor weathering test conducted in India condition test lab for the product offered shall be submitted by the contractor. All Boards must be manufactured via. digital Printing process as per IRC 67:2022, & bidder must submit outdoor weathring test report of digital printed board as per IRC along with bid. | 1 | Nos | 29,95,500 ₹29,95,500 Lowest |
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
28 Jul 2025, 5:00 pmClosed
DIRECTOR INFORMATION
16 PARK ROAD HAZRATGANJ LUCKNOW
Supply and fixing of Ratro structure on the Boundry of Uttar Pradesh connecting to boundry other states
2025_DIPR_1056977_1
633/DIPR/2025
Open Tender
Miscellaneous Works
Item Rate
ALL U P
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
DIRECTOR INFORMATION
₹5 L
Yes
14 Aug 2025
15 Jul 2025
29 Jul 2025
15 Jul 2025
28 Jul 2025
15 Jul 2025
Details of items
6M SPAN CANTILEVER STRUCTURE WITH ONE VERTICAL POST: Supply & Erection of One No builtup cantilever structure 7.22 mtr Hight and 6.00 mtr span comprising of one vertical post of 7.22 Mtr. High made up of 300mm pipe & horizantal structure post of 6 Mtr. High made up of 300mm pipe member welded with (600mm X600 mmX20 mm) MS round plate at top and MS plate (600 X 600 X 20mm) at bottom of vertical pipe . Both 300mm pipe Flanged joints with 300mm pipe 610 mm Albow Type height as per Approved Design, Drawing with one coat of steel primer and two coats of synthetic enamel paint Also vertical pole should have the strip of AFP (Alluminium Flexible Sheeting) 0.3x 0.9 M Pasted and 2 Nos. FMM (Flexible Median Marker) fixing with Epoxy to provide median safety during night time or severe weather at the top of foundation after complete construction of RCC fondation of size 0.600 x 0.600 and 1.80 Mtr. deep for built up structure including earthwork in excavation, 150mm thick lean concrete in 1:3:6 cement, coarse sand and 40mm guage stone ballast, RCC with 1:1.5.:3 cement, coarse sand and 20mm stone grit including supply & courting of 32 mm Dia foundation bolts (600mm long) as per provision of structure including coast of reinforcement and shuttering as per direction of Engineerin- Charge, signage facia for both side of structure must be considered which comprises of ACP sheeting pasted with TYPE XI retro reflective sheeting as per IRC 67 : 2022. The signage shall include lettering and signs/ legends as Applicable. Back support frame shall be of 35x35x5mm MS angle. Add 2 per cent of cost of angle iron towards cost of drilling holes, nuts, bolts etc.The contractor need to submit calcoast test report for specular gloss & fungus resistance test as per IRC 67:2022 for clearance of final bill.All boards must be printed via OEM approved Digital printer self owned bu converter with MTS warranty of OEM as per the IRC 67-2022.. The reflective sheeting signage facia shall be covered with ultra voilet overlaminate transparant film 10 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from government test lab report of 3 year outdoor weathering test conducted in India condition test lab for the product offered shall be submitted by the contractor. All Boards must be manufactured via. digital Printing process as per IRC 67:2022, & bidder must submit outdoor weathring test report of digital printed board as per IRC along with bid.
12 TO 16.00 M SPAN OVER HEAD STRUCTURE WITH TWO VERTICAL POST: Supply and Erection of One No builtup overhead structure 12 to 16 m span comprising of two vertical post of 7.22 mtr. height made up of 350mm Vertical Pipe Post and horizontal Truss structure post of 250 mm N.B. medium class M.S. Pipe post as member. The post will be welded with (600x 600x10mm) M.S. round plate at top and (900x900x20mm) M.S. plate at bottom for of vertical pipe . Both 300 mm pipe are connected to truss by 610mm Albow Pipe as per approved Design. Drawing with one coat of steel primer and Two coats of synthetic enamel paint Also vertical pole should have the strip of AFP (Alluminium Flexible Sheeting) 0.3x 0.9 M Pasted and 2 Nos. FMM (Flexible Median Marker) fixing with Epoxy to provide median safety during night time or severe weather at the top of foundation after complete construction of RCC fondation of size 0.900 x 0.900 mm and 1800 MM. deep for built up overhead structure including earthwork in excavation, 100 mm thick lean concrete inl:1:2 cement, coarse sand and 20mm guage stone ballast, RCC with 1:1.5:3 cement, coarse sand and 20mm stone grit including supply & courting of 32 mm Dia foundation bolts (750 mm long) as per provision of structure including cost of reinforcement and shuttering as per direction of Engineer-in-Charge , signage facia for both side of structure must be considered which comprises of ACP sheeting pasted with TYPE XI retro reflective sheeting as per IRC 67 : 2022. The signage shall include lettering and signs/ legends as Applicable. Back support frame shall be of 35x35x5mm MS angle. Add 2 per cent of cost of angle iron towards cost of drilling holes, nuts, bolts etc.The contractor need to submit calcoast test report for specular gloss & fungus resistance test as per IRC 67:2022 for clearance of final bill.All boards must be printed via OEM approved Digital printer self owned bu converter with MTS warranty of OEM as per the IRC 67-2022.. The reflective sheeting signage facia shall be covered with ultra voilet overlaminate transparant film 10 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from government test lab report of 3 year outdoor weathering test conducted in India condition test lab for the product offered shall be submitted by the contractor. All Boards must be manufactured via. digital Printing process as per IRC 67:2022, & bidder must submit outdoor weathring test report of digital printed board as per IRC along with bid.
15 TO 25.00 M SPAN OVER HEAD STRUCTURE WITH THREE VERTICAL POST: Supply, fixing & erection of One No builtup Overhead Structure of 15.00M to 25.00M span comprising of three vertical posts 300 OD-7.50M height [One vertical post is made by combining the Two pipe 300 OD as per approved drawing}.The post will be welded with (600x 600x20mm) M.S. round plate at top and (600x1800x20mm) M.S. plate at bottom of vertical pipe.The Truss supported by the Vertical pipes will be made by combining the Two pipes of 300 dia. by 114 od 0.90m pipes and truss will be connected by the Vertical posts by 610 mm Albow .Also vertical pole should have the strip of AFP (Alluminium Flexible Sheeting) 0.3x 0.9 M Pasted on each vertical post and 2 Nos. FMM (Flexible Median Marker) fixing with Epoxy to provide median safety during night time or severe weather at the top of each foundation. This work includes design and construction the RCC foundation of size 0.800 x 2.0m and 2.10 Mtr. deep for built up structure including earthwork in excavation, 150mm thick lean concrete in 1:3:6 cement, coarse sand and 40mm guage stone ballast, RCC with 1:1.5.:3 cement, coarse sand and 20mm stone grit including supply & courting of 32 mm Dia foundation bolts (1000mm long) as per provision of structure including coast of reinforcement and shuttering as per direction of Engineerin- Charge, signage facia for both side of structure must be considered which comprises of ACP sheeting pasted with TYPE XI retro reflective sheeting as per IRC 67 : 2022. The signage shall include lettering and signs/ legends as Applicable. Back support frame shall be of 35x35x5mm MS angle. Add 2 per cent of cost of angle iron towards cost of drilling holes, nuts, bolts etc.The contractor need to submit calcoast test report for specular gloss & fungus resistance test as per IRC 67:2022 for clearance of final bill.All boards must be printed via OEM approved Digital printer self owned bu converter with MTS warranty of OEM as per the IRC 67-2022.. The reflective sheeting signage facia shall be covered with ultra voilet overlaminate transparant film 10 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from government test lab report of 3 year outdoor weathering test conducted in India condition test lab for the product offered shall be submitted by the contractor. All Boards must be manufactured via. digital Printing process as per IRC 67:2022, & bidder must submit outdoor weathring test report of digital printed board as per IRC along with bid.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .