Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹10.9 L+₹30,720 (2.90%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L2 | Rejected-Finance Awarded being 2nd Lowest Bidder | |
| 3 | L3₹11.2 L+₹66,238 (6.26%)Rejected-Finance | L3 | Rejected-Finance Awarded being 3rd Lowest Bidder | |
| 4 | L4₹11.7 L+₹1.2 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Awarded being 4th Lowest Bidder | |
| 5 | L5₹12.6 L+₹2.1 L (19.4%)Rejected-Finance | L5 | Rejected-Finance Awarded being 5th Lowest Bidder |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
17 Feb 2023, 6:00 pmClosed
Vinod Kumar AE (Civil) AGE BR II Offg GE(S)Bathind
GE(S)Bathinda Bathinda Mil Stn
GE(S) BTD TOKEN NO 65 OF 2022-23 REPAIR TO CEILING FANS EXHAUST FANS WALL MOUNTING FANS AND PEDESTAL FANS AND OTHER CONNECTED EM WORKS IN ZONE B (MD ACCOMMODATION AND OTM ACCOMMODATION AREA) UNDER AGE EM IV UNDER GE(S) BATHINDA AT BATHINDA MIL STN
2023_MES_576211_1
GE(S)/BTD/TOKEN NO 65 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE(S)Bathinda
Class E
Category b(i)
11 documents required · 11 mandatory
₹500
GE(S)Bathinda
₹44,000
Yes
2 Mar 2023
20 Jan 2023
20 Feb 2023
20 Jan 2023
17 Feb 2023
3 Feb 2023
Amount
M&L for collecting unserviceable ceiling fans 1200 mm sweep 230V, AC single phase from store yard of AGE E/M, dismantling the ceiling fan and taking out complete burnt winding from fan motor and rewinding the same with super enamelled copper winding wire of exisiting gauge & size including thoroughly cleaning all the components of fan, oiling varnishing,Greasing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core twisted copper cable approximate one metre long for each fan , machine screws etc, depositing the repaired fan to store yard complete all as specified and as directed.
All as per item No 1 here-in-before but ceiling fan of size 1400 mm sweep of any make & type/model.
All as per item No 1 here-in-before but exhaust fan of size 450mm sweep of any make & type/model.
All as per item No 1 here-in-before but exhaust fan of size 380mm sweep of any make & type/model.
All as per item No 1 here in before but wall mounting fan of any sweep/make. & type/model.
All as per item No 1 here in before but for Air Circulator, Pedestal fan of size 600mm sweep complete. & type/model.
Note for item No 1 to 6 :- Rewinding shall be carried out in the AGE E&M store yard and necessary rent shall be deducted from contractor payment.
S & F in replacement fan motor for exhaust fan of size 300mm/230mm sweep of any make. & type/model.
S & F in replacement fan motor for existing PVC body ventilation fan 200/225/250mm size
Supply and fixing in replacement dry type capacitor 3.15 mfd suitable for any type and any make fan complete all as specified and as directed.
Supply and fixing in replacement dry type capacitor 4 mfd suitable for any type and any make fan complete all as specified and as directed.
Taking out the defected ball bearing of ceiling fans / Exhaust fans/ air circular fans / pedestal fans and supply and fix new ball bearing suitable for existing housing of 6201& 6202 including necessary machine work complete all as specified and directed.
All as per item No 12 here in before but of No 6203 complete all as specified and as directed.
Taking out the worn out Gun Metal Bush and supply and fixing new gun metal bush of suitable size for any sweep and make of celing fan /exhaust fan / table fan / air circulator / cabin fan complete all as specified and directed.
Supply and fixing louver shutter for 300mm size exhaust fan including taking down old unsv complete all as specified and directed.
Supply and fixing stepped type electronic fan regulator, (socket type) flush type 230/240 volt & connecting up complete on existing laminated sheet cover complete all as specified and directed.
Supply and fixing stepped type electronic fan regulator, (switch type) flush type 230/240 volt & connecting up complete on existing laminated sheet cover complete all as specified and directed.
Supply and fixing stepped type modular electronic fan regulator, (02 module) 230/240 volt & connecting up complete all as specified and directed.
Taking out the worn out / defective blades of ceilng fan of 1200 mm sweep and supply and fixing new blades with screws and spring wasers complete all as specified and directed.
All as per item No 19 here in before but ceiling fan of size 1400 mm sweep.
Labour only for Attending complaints of ceiling fan/exhaust fan/wall fan,at various location including ckecking for safety by taking down & checking of rubber bush, by nut, bolt and locking pin of ceiling hook,fan down rod, canopy, U clamp etc for safty to avoid fall down the ceiling fan and rectify the same by replacing with new spare/components complete all as specified and directed.
Note for item No. 21 :- (i) Spares required against checking/attending complaint shalll be measured and paid seperately here in after as supply only. (ii) The contractor or his representative will attnd the office of the Engr-in-Charge daily( Working Day ) at 9.30 AM to collect the complaint slip and will provided sufficient number machine for repair /rewinding of fans and cost of the same will be given in respective sch item.The complaint will be completed/done with in 24 hrs fromthe the date of issue of complaint slip, failing which a panel recovery of Rs 50/- per complaint per day will be recovered form contractor .
Supply only new hanging rod 600 mm long for any make and any type of ceiling fan complete having two Nos holes complete all as specified and directed.
Supply only 'U' clamp with rubber reel, nut, bolt and split pin of superior quality for ceiling fans complete all as specified and directed.
Supply only canopy set suitable for any make / size ceiling fan complete all as specified and as directed.
M & L for painting of ceiling fan any make of size 1200/1400 mm with one coat of white synthetic enamel paint with spray gun including preparing surface and making surface of body, down rod and blade even and smooth etc incl writing SM/MES No where diretcted after painting all as specified and directed.
Supply and fixing in replacement fan hook of size 15 mm dia MS bars, fixed to RCC roof or perlin for hanging of ceiling fan complete all as specified and directed.
Taking down old unsv point wiring and M&L for point wiring in existing conduting one ceiling fan/light/ 5 Amp ind controlled by one switch with 1.5 sqmm (nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FR-LSH controlled by one switch,including PVC insulated unsheathed 1.5 sqmm copper conductor cable FR-LSH connected to common earth dolly complete all as specified and directed.
(a) All as per srl item No. 28 above One light point / fan point controlled by one, one way switch 5 Amp complete all as specified and directed.
(b) All as per srl item No. 28 above One 3 pin socket outlet 5 amp independent complete all as specified and directed.
(c) All as per srl item No. 28 above but for one 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq mm size complete all as specified and directed.
(d) All as per srl item No. 28 above but for call bell point complete all as specified and directed.
(e) All as per srl item No. 28 above but for one 3 pin socket outlet 15 amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in contineous earth wire complete all as specified and directed.
(e) All as per srl item No. 28 above but for one light controlled by two two way switch complete all as specified and directed.
Taking down old unsv point wiring and M&L for point wiring for one ceiling fan/light/ 5 Amp ind controlled by one switch with 1.5 sqmm (nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FR-LSH in and including concealed PVC conduit 20 mm dia medium duty ISI marked, flush to surface for one fan point/light/ 5 amp ind controlled by one switch,including PVC insulated unsheathed 1.5 sqmm copper conductor cable FR-LSH connected to common earth dolly complete including cutting, chasing the surface and then making good to disturbed surfaces with cement mortar and painting the suraface to match with surrounding complete all as specified and directed.
(a) One light point controlled by one, one way switch 5 Amp complete all as specified and directed.
(b) One 3 pin socket outlet 5 amp independent complete all as specified and directed.
(c) One 3 pin socket outlet 5 amp on the same board with other switches, with cables 1.5 sq mm size complete all as specified and directed.
(d) One bell point controlled by one bell push complete all as specified and directed.
(e) All as per srl item No. 35 above but for one 3 pin socket outlet 15 amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in contineous earth wire complete all as specified and directed.
Supply and fixing switch piano flush type ,6 Amp one way 240V AC (ISI Marked) including taking down old complete all as specified and directed.
Supply and fixing switch piano flush type single pole, two way 5 Amp including taking down old complete all as specified and directed.
Supply and fixing switch piano flush type ,16 Amp one way 240V AC (ISI Marked) including taking down old complete all as specified and directed.
Supply and fixing bell push 5/6 Amps 230 V AC including taking down old complete all as specified and directed.
Supply and fixing socket outlet 3 pin, 5A, 240 V AC flush type including taking down old complete all as specified and directed. Note:- Switch and socket will be of same brand.
Supply and fixing socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type including taking down old complete all as specified and directed. Note:- Switch and socket will be of same brand.
Supply and fixing call bell ding dong type AC 230 V including taking down old complete all as specified and directed.
Supply and fixing stepped type electronic fan regulator including taking down old complete all as specified and directed.
Supply and fixing in repacement complete for ceiling rose surface backelite three terminal 240 volt complete all as specified and directed.
Supply and fixing in repacement Lamp holder PVC/polycarbonate type with back plate complete all as specified and directed.
S&F wall mounted extruded Aluminium / polycarbonate LED batten fixture T8(G13 holder) 1.2 m, including one LED retrofit tube 20(±10%) watt, 1.2 m T8 6500K,efficacy not less than 90 lumen/watt, extruded Aluminium / polycarbonate, PC diffusor and inbuilt driver complete including making connection complete all as specified and directed.
S&F in repair wall mounted LED batten fitting 10 (±10%) watt, 6500K, 0.6m, efficacy not less than 90 lumen/watt , extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete includign making connection complete all as specified and directed.
S&F in replacement sub main two single core PVC copper conductor insheathed wire multi stranded 6 sqmm in existing PVC conduit pipe and including 6.0 sqmm copper conductor single core wire connected by common earth complete all as specified and directed. Note:- Three lengths of 6 Sqmm cable will be measured as one length.
Note:- Net contract sum shall be calculated after deduction of Sch of credit.
SWARN SINGH AND CO.
L H ENTERPRISES
M/S SODHI ASSOCIATES
M/s Kataria Construction Company
NASIB ENGINEERS AND CONSTRUCTION
SIGMA ENGINEERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .