Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹2.0 LAccepted-Finance 58 KAILASHPURAM GOVINDPURAM GAZIABAD | GHAZIABAD | UTTAR PRADESH | I | Accepted-Finance Accept | |
| 2 | II₹2.0 LRejected-Finance BH 16 MANSAROVER COLONY LINE PAR MORADABAD UTTAR PRADESH 244001 | MORADABAD | UTTAR PRADESH | 244001 | II | Rejected-Finance Reject | |
| 3 | III₹2.0 LRejected-Finance 19 A DURGA BARI SADAR BAZAR MEERUT MEERUT MEERUT UTTAR PRADESH 250001 | MEERUT | UTTAR PRADESH | 250001 | III | Rejected-Finance Reject |
Tender Value
Refer Docs
EMD Value
₹4,000
Closing Date
3 Apr 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
132 KV S/S Bharua Sumerpur
Work
2024_UPTCL_920222_1
TS-84/ETD(H)/2023-24
Open Tender
Electrical Works
Lump-sum
45 days
132 KV S/S Bharua Sumerpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
Executive Engineer
₹4,000
Yes
6 Apr 2024
23 Mar 2024
4 Apr 2024
23 Mar 2024
3 Apr 2024
23 Mar 2024
Amount
Details of Work.
Major overhauling and repairing work of following 132 KV SF-6 Gas and air compressor type Circuit Breaker at 132 KV Substation Bharua Sumerpur under ETD Hamirpur :-
132 KV SF-6 Gas and Air Compressor type, 120 - SFM - 32 A Circuit Breaker (CGL Make) of 132 KV Transfer Bus Coupler bay (Mfg. Year - 1986) at 132 KV Substation Bharua Sumerpur under ETD Hamirpur. By doing following works in circuit breaker :- (i)- Cleaning of porcelain of drive insulator from outside of each pole. (ii)-Checking & adjustement of snatch gap, travel of drive insulator rod & tie rod of each pole. (iii)- Opening of opening & closing coil assembly, D-rusting & greasing of all these parts, checking of charging ratchet. Replacement of all O-Rings of Gas pipe assemby of mechanism, checking of motor limit Switch, auxiliary contactors, power contaclors. (iv)- Oiling & greasing of crank gears by opening of lock circlip etc. (v)- Retightening of all these connections, satisfactory operation from local as well remote. (vi)-Dismantling of pneumatic system of mechanism assembly and dismantling of control valve assembly, main spring, cleaning, lubrication and replacement of control valve sheet, cap. seal assembly, O ring P- 80, cap. seal assembly, roller C&D and re - fitting the same. (vii)- Checking operation of circuit breaker from remote and local. (viii)- Checking electrical connection in the marshalling box and tightening all electrical connections and replacing compressor belt with proper size. (ix)- Complete dismantling of compressor from breaker structure and dismantling of all its parts and drain out all used oil from the compressor, replace all piston rings, piston head, gaskets, flat finger plate, air filter and seal (if required) and re - fitting the same with all proper adjustment. (x)- Fill special compressor oil upto specified value and check manually its proper function and remount the compressor into breaker cubicle and fitting with the motor with proper alignment and replacing compressor belt with proper size. After major overhauling and repairing work of above gas circuit breaker, following tests are to be carried out :- (i)-Opening & closing time of breaker of each pole. (ii)- Carrying out Contact Resistance Measurement (CRM test) of each pole. (iii)- Checking of megger values of breaker poles. (iv) - Checking triping of breaker at 70% DC voltage. (v) - Checking the CLOSE/OPEN operation of breaker from REMOTE & LOCAL. (vi)- Prepare and submit the site ovehauling report of each breaker.
Major Overhauling work of following 33 KV VCBs at 132 KV S/S Bharua Sumerpur under ETD hamirpur. (i) 33 KV Hamirpur (ii) 33 KV Maudaha (iii) 33 KV Para-Raipura (iv) 33 KV Biwar (v) 33 KV Laghudal By doing following work in each circuit breaker:- (i) (i) Cleaning of porcelein of drive insulator and porcelain of vacuum intruptor from inside and outsiude of each pole. (ii) Checking & adjustment of snatch gap, travel of drive insulator rod & tie rod of each pole. (iii) Opening, repairing of mechanism by welding, drilling, matching & filling of material as per requirement and proper fitting of it in breaker inside. (iv) Oiling & greasing of crank gears by opening of lock circlip etc. (v) Replacement of worn out parts such as bush, rings, lock pins and latch etc. (vi) Checking & Adjustment of oil daspot of breaker for its damping action. After major overhauling and repairing of above circuit breakers, following tests are to be carried out:- (i) Opening & Closing time of breaker of each pole. (ii) (ii) Checking of Megger values of each breaker poles. (iii) Checking of tripping of breaker at 70% DC Voltage. (iv) Checking the CLOSE/OPEN operation of breaker from REMOTE & LOCAL (v) Prepare and submit the site overhauling report of above circuit breakers at 132 KV S/S Bharua Sumerpur
Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra
TIRUPATI ELECTRICALS
Technocrat Electrical
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .