Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Others-Due to Non Submission of EMD. |
Tender Value
Refer Docs
EMD Value
₹4.7 L
Closing Date
7 Jul 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Capital Division
Office of The Executive Engineer Capital Division A PWD AP Itanagar
Construction of RCC Bridge over Yopo River Nallah near Chandarnagar Power House connecting Ganga via F and G Sector Itanagar
2022_PWDAP_797_1
CD-A/W-3/6A/2022-23/e-T-04
Open Tender
Civil Works
Item Rate
365 days
Itanagar
Not more then 2 Works in Hand
2 documents required · 2 mandatory
₹1,000
EE CD-A PWD Itanagar
₹4.7 L
Yes
Itanagar
15 Jul 2022
1 Jul 2022
15 Jul 2022
1 Jul 2022
7 Jul 2022
1 Jul 2022
1 Jul 2022 - 4 Jul 2022
4 Jul 2022
90 days
Amount
Sh:- Site Development
Excavation in Hill Area in Soil by Mechanical Means. Excavation in soil in hilly area by mecnanical means including cutting and trimming of side slops and disposing of excavated earth with all lifts and lead upto 1000 Mtrs.
Excavation in Hill Area in Ordinary Rock by Mechanical Means -Excavation in hilly area in ordinary rock not requiring blasting by mechnical means including cutting and trimming of side slops and disposing of excavated earth with all lifts and lead upto 1000 Mtrs.
Sh:- RCC Composite Bridge
Dismantling of Structures (Dismantling of existing structures like culverts,bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres) (II) By Mechanical Means for items No. 202( b) & ( c) B) Prestressed / Reinforced cement concrete grade M-20 & above
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. (a) Ordinary soil 3 m to 6 m depth
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (b) Hard rock ( blasting prohibited ) Mechanical Means(without de-watering)
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M25/ Using Concrete Mixer
Plain/Reinforced Cement Concrete in super-structure complete as per Drawing and Technical Specifications. (a) RCC Grade M25/ Using Concrete Mixer
Plain/Reinforced Cement Concrete in super-structure complete as per Drawing and Technical Specifications. a) RCC Grade M30 Using Concrete Mixer
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) RCC Grade M25/ Using Concrete Mixer
Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches toHYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24
Providing, fitting and fixing mild steel railing complete as per drawing and Technical Specification
Drainage spouts complete as per drawing and technical specificatios
Supplying, fitting and placing HYSD bar reinforcement in Foundation complete as per drawing and Technical Specifications.
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications.
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and Technical Specifications.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (A) Granular material
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical Specifications
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.
Supply and fabrication of steel work at Fabricators workshop comprising of Main Girders, Cross Girders, Connecting plates, stringer, stiffening plates etc. from steel plates and structural steel of specified grades as per approved drawing including straightening, descaling, degreasing, cutting to size and shape, drilling, welding and grinding, supply of all MS/HTS shop or site bolts, nuts & washers, holding down bolts and nuts etc., trial assembling at workshop, one priming coat of shop paint with red lead paint conforming to IS-102 with all labour, material, cost of paints, consumables, stacking in protected condition etc. complete as per specification and as directed by the Engineer-in-Charge (Carriage cost from fabricator work shop to actual bridge site will be paid seperately). A) COMPOSITE BRIDGE (Case-I) Upto 40m single span or in Multiples
Taking delivery of fabricated steelwork from stacks at site as necessary, assembling and erection of fabricated steel structure to proper line , level and camber as per approved drawings complete in all respect including transportation and handling supply of all fasterners. Painting of all exposed surfaces of steelwork after erection with one coat of red lead confirming to IS-102 and two coats Alumunimium paint to IS-2339, grouting of anchor bolts in position, including all labour, consumables, materials, machinery, tools and tackles complete as per specification and as directed by the Engineer-in-Charge A) COMPOSITE BRIDGE (Case-I) Upto 40m single span or in Multiples
Bearing( Elastometric bearing assembly consisting of 7 internal layers of elastometer bonded to 6 Nos. internal reinforcing steel laminates by the process of vulcanisation.
Sh:- CC Drain
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)Ordinary Soil up to 3 m depth
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications PCC Grade M20
Sh:- RCC Retaining Wall
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)(upto 3 m depth)
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. a)RCC Grade M20/ Using Concrete Mixer
Plain/Reinforced Cement Concrete in sub-structure complete as per Drawing and Technical Specifications. a) RCC Grade M20/ Using Concrete Mixer
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications, In Footing and Main Wall
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (A) Granular material
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical Specifications
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.
M/S GODAK BIDA
stage.html
html • 0.02 MB
finance_900.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .