Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹21.0 L+₹3.6 L (20.5%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹21.2 L+₹3.7 L (21.4%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹21.2 L+₹3.8 L (21.6%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹21.3 L+₹3.9 L (22.2%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Rejected |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
26 Feb 2024, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
REPAIR MAINTENANCE OF LED FITTINGS AND FIXTURES INCLUDING RE WIRING AND REPLACEMENT OF OLD UNSV DBS OF VIP OMQ ACCN AND CERTAIN EM NATURE ALLIED WORKS AT OMQ QTRS OF SPE AREA UNDER GE AF SUBROTO PARK
2023_MES_598247_2
GE/SP/ TOKEN-38/2023-24
Open Tender
Civil Works
Item Rate
180 days
Subroto Park Delhi Cantt
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) Subroto Park
₹1 L
Yes
27 Jun 2024
8 Feb 2024
28 Feb 2024
8 Feb 2024
26 Feb 2024
21 Feb 2024
Amount
Taking down carefully copper/aluminium point wiring( light ,fan, socket or power) complete, fitting such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5sq mm PVC insulated S /C unsheathed 1100 v grade IS -694 stranded copper conductor FRLS cable drawing including and into PVC conduit not less than 20 mm dia in wall PVC concealed Conduit including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire connected to main earth dolly for one light point controlled by one switch complete all as specified and directed by Engineer in Charge.
All as per srl item 2 above but for one C/ fan/Exhaust fan point controlled by one switch regulator.
All as per item No 2 above but for one 3 pin 5 amps socket outlet on indipendent board with other switchs.
All as per item No 2 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 2 above but for one light point controlled by two way switches.
All as per item No 2 above but for Call bell controled by one push button in indipendent board .
All as per item No 2 above but with 2.5 Sq mm cable for Independent one 3 pin 15 Amps socket outlet In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
M&L for point wiring for one light fitting / one fan point controled by one switch with 1.5 Sq mm PVC insulated copper conductor cable drawing in and including PVC Casing/capping with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly with 3mm thick plastic laminated sheet cover complete for one light/fan point controlled by one switch complete all as specified and directed by Engineer in Charge.
All as per srl item 9 above but for one fan point controlled by one switch through regulator.
All as per srl item 9 above but for one 5 pin 5 amps socket outlet on the independent board.
All as per item No 9 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 9 above but for Call bell point.
All as per item No 9 above but with 2.5 Sqmm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
M&L for point wiring with 1.5sqmm PVC insulated unsheathed multi stranded copper conductor cable drawing in existing steel/PVC conduit with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly excluding 3mm sheet metal box and hylam sheet complete for one light/fan point controlled by one switch complete all as specified and directed by Engineer in Charge.
All as per srl item 15 above but for one fan point controlled by one switch through regulator.
All as per srl item 15 above but for one 5 pin 5 amps socket outlet on the independent board.
All as per item No 15 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 15 above but for one light point controlled by two way switches.
All as per item No 15 above but for Call bell point.
All as per item No 15 above but with 2.5 Sq mm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
S&F in replacement switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed at site.
S&F in replacement switch piano, flush type single pole, two way, 5 Amps, 240 volts all as specified and directed at site.
S&F in replacement switch piano, flush type single pole, one way, 15 Amps, 240 volts all as specified and directed at site.
S&F in replacement socket outlet 5 pin 5 Amps all as specified and directed at site.
S&F in replacement socket 16 Amps, 2 in 1, flush type all as specified and directed at site.
Supply and fixing in replacement ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site.
Supply & fix in replacement bell push, flush type, 5 Amps, 240 volts all as specified and directed at site.
Supply only in replacement Electric calling Bell Ding Ding Type suitable for 230 volts.
Supply only Fan Regulator step type 120 watt, 240 volt complete .
Supply and fixing in replacement PVC gang box suitable for one switch 5 Amps complete with screw and necessary arrangement complete all as specified and directed by Engineer in Charge.
All as per srl item 31 above but for one 5 amps switch socket outlet.
All as per srl item 31 above but for one 15 amps switch socket outlet.
S&F in repair of sub main wiring with 2 single core 04 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in and incl rigid non metallic PVC conduit 25 mm dia incl 4.0 Sq mm PVC insulated single core copper conductor cable for continuous earth wire.
All as per Item No 34 but with 2 single core 06 Sq mm incl 6 Sq mm PVC insulated single core copper conductor cable for continuous earth wire.
M & L for rigid non metalic PVC medium grade conduit including junction boxes, tee, bends, elbows, reducers bell mouth tube ends,fixing accessories such as couplers, lock Nuts, saddle pipe hook etc for 25 mm dia.ISI Marked.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 230 volt MCB 20 amps.
Dismantling of unserviceable light fitting of any type and wattage from the buildings after disconnecting the electric supply and keeping in safe custidy for giving credit to the contractor all as specified and directed by engr-in-charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing decorative LED wall light Nickel fitting premium opal glass for reduced glare designed for use with energy saving light bulbs suitable for 9/11 watt LED with 100 lumen/watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to terminal block, and testing complete all as specified and directed by the Engineer-In- Charge. Note :- Rates of LED bulb are deemed to be included in quoted rate
Supply and fixing ultra slim surface decorative 12 watt with 100 lumen/watt, 6000 K ,230 volt, LED ceiling fitting, complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer-In- Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, fixed on two PVC round blocks and testing complete all as specified and directed by the Engineer-In- Charge.
Supply and fixing wall mounted LED bulk head fittings, 10 watt, warm white,, 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer-In- Charge.
S&F ultra modern design architectural design 34 watt 2x2 recess LED, 6000 K luminaire having glare free symmetrical illumination Complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of exhaust fan heady duty metal body 300 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of exhaust/ventilating fan heady duty metal body type 230 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of exhaust/ventilating fan heavy duty plastic body 250 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of wall mounting fan heady duty 300 mm sweep including necessary fixing arrangement for proper fixing on wall as per site requirement complete all as specified and as directed by Engineer-in-Charge. Model No- Swing Penta Wall Fan.
Cutting of existing surface/wall for making hole suitable for fixing of exaust fan of required size including 04 Nos hold fastner and making good the disturbed surface all as specified and as directed by Engineer-in-Charge.
Taking down old unsv MCB DB of any size.
Supply and fixing in replacement load line vertical distribution board 'A, frame made out of CRCA 2mm thick mild steel sheet,double door, surface mounting TPN 8 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 125 Amps =01 No MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 125 Amps =01 No MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type Cat Part No - DHDPSHODRW08 complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type Cat Part No - DHDPSHODRW08 complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCCB four Pole 125 Amps, 415 volt thermal release bearing cap 16 KA suitable for the MCB DB above comlete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, 240 volts, 6 to 40 amps C Curve capacity.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, and neutral, 240 volts, 40 amps C Curve capacity.
S&F MCB TP 63 Amps 10 KA, 440 volt 50 Hz all as specified ans directed by engineer in- charge.
S&F MCB TP 100 Amps 10 KA 440 volt 50 Hz all as specified ans directed by engineer in- charge.
S&F in replacement LED Tube rod 20 watt complete all as specified.
S&F LED Bulb 9 watt retrofit type 2700K (Yellow/white colour) complete all as specified.
S&F in replacement of fan capacitor with copper wire plastic body 2.5 mfd.
S&F in replacement of fan capacitor with copper wire plastic body 3.15 mfd.
Taking down the old white hylium sheet from the existing flash metal box and replacing new supper quality white hylium sheet of size 8" x 10" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 65 above but of size 5" x 5" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 65 above but of size 8" x 5" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 65 above but of size 9" x 13" complete all as specified and as directed by Engineer-in-Charge.
S&F Non Retrofit CFL 11 watt two pin 2700K (Yellow colour) complete all as specified
Supply & fix in replacement Batten Holder PVC white suitable for retrofit type CFL/LED Lamp cxomplete allas specified and as directed.
Supply & fix in replacement of Casing capping double lock type supper quality size 20 mm width ISI marked with fixing accessories complete all as specified and directed by Engineer in Charge.
Supply & fix in replacement of brass screw 3/18, long threaded suitable for fixing switch boards. ( 100 Nos in one packet)
Supply & fix in replacement of brass screw 9/11, long threaded suitable for fixing switch boards. ( 100 Nos in one packet)
Supply & fix in replacement of stainless steel screw 1/2" long. ( 200 Nos in one packet)
Supply & fix in replacement of stainless steel screw 1" long.( 200 Nos in one packet)
Supply and fix in replacement of flexible wire twin core 23/.076 complete all as specified and as directed by Engr-in- Charge.
Supply and fix in replacement of twin core aluminium flexible wire conductor of size 10 sq mm 2 core complete all as specified and as directed by Engr-in- Charge.
S&F in replacement of ceiling fan heady duty 1200 mm sweep including necessary fixing arrangement for proper fixing as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully ceiling fans of any size for repair/service/rewinding/greasing and refixing in its original position after necessary repair/rewinding/servicing/greasing etc including connecting up with flexible twin core cable 23/0.0076 from ceiling rose or connector to fan complete and to ensure that ceiling fan should be fix in position in all respect all as directed by Engineer in Charge.
M& L for minor repair/service and greasing of bearings, cleaning of dust on ceiling fans with blades and canopys and reconnecting the electrical conections and with regulators complete all as specified and as directed by Engineer-in-Charge. Note: All required Materials are deemed to be included in the unit rate quoted.
M & L for repair to Ceiling fan of of any size by replacing unserviceable ball bearing of suitable size including neccessary greasing complete all as specified and directed by Engineer-in-Charge.
M&L for Rewinding of ceiling fan of sweep 1200mm/1400 mm sweep of any make and model with super enameled copper winding wire of same size as per old winding wire and confirming to relevent IS including replacement of insulation material, varnishing, greasing and lubricating, ball baring, GM bushes and replacement of suitable capacity of condenser and testing complete all as specified and directed by Engineer in Charge.
M/S LADPURIA ENTERPRISES
OMVIN ENTERPRISES LLP
M/S MG GROUP
J.P. Enterprises
Commercial Traders
Vijeta Solutions
M/S ANIL KUMAR
BB Engineer and Contractor
M P TYAGI ENGINEERS AND CONTRACTORS
Mahesh Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .