| 1 | L1₹9.7 CrAccepted-AOC PLOT NO 178 A MLA COLONY ROAD NO 12 BANJARA HILLS HYDERABAD 500 034 | HYDERABAD | TELANGANA | 500034 | ₹9.7 Cr Quoted ₹9.8 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹10.1 Cr+₹34.6 L (3.54%)Rejected-Finance NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | ₹10.1 Cr+₹34.6 L (3.54%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹10.4 Cr+₹65.6 L (6.71%)Rejected-Finance | ₹10.4 Cr+₹65.6 L (6.71%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹10.6 Cr+₹80.7 L (8.25%)Rejected-Finance | ₹10.6 Cr+₹80.7 L (8.25%) | L4 | Rejected-Finance Not lowest |
| 5 | L5₹10.9 Cr+₹1.1 Cr (11.6%)Rejected-Finance SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | ₹10.9 Cr+₹1.1 Cr (11.6%) | L5 | Rejected-Finance Not lowest |
Tender Value
₹10.7 Cr
EMD Value
₹8.6 L
Closing Date
14 Oct 2024, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD OPP JUBILEE BUS STATION PICKET SECUNDERABAD - 500003
PROVISION OF NEW BUILDING AND ADDITION ALTERATION FOR EXISTING BUILDINGS AS PART OF IF PROJECT AT AERONAUTICAL MATERIALS TESTING LABORATORY AMTL UNDER GE I RND KANCHANBAGH HYDERABAD
2024_MES_670057_1
84013
Open Tender
Civil Works
Lump-sum
450 days
Kanchanbagh Hyderabad
Class S
Category a (i)
8 documents required · 8 mandatory
₹3,000
GARRISON ENGINEER I RND KANCHANBAGH HYDERABAD
₹8.6 L
Yes
19 Nov 2024
2 Sept 2024
21 Oct 2024
2 Sept 2024
14 Oct 2024
30 Sept 2024
Amount
Schedule 'A' Part-I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl item Nos. 1.01 & 1.02) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of permanent new building No. 1 with RCC framed structure with RCC M-30 design mix and fly ash brick masonry super structure with RCC roof complete all as specified and shown on drawings.
Lumpsum price worked out by the contractor for Construction of permanent new building No. 2 with RCC framed structure with RCC M-30 design mix and fly ash brick masonry super structure with RCC roof complete all as specified and shown on drawings.
Lump sum price worked out by the Contractor for “SITE DEVELOPMENT WORKS" as listed in Schedule ‘A’ Part - II representing _______ % ______________ percent Above / Below the lump sum price of `2,26,610.00 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “ADDITION / ALTERATION FOR EXISTING BUILDINGS” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of `1,63,72,854.90 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of ₹43,480.90 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION (NEW AND EXISTING BLDG)” as listed in Schedule ‘A’ Part - V representing __________ % ____________ percent Above / Below the lump sum price of ₹34,65,562.00 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for “AREA DRAINAGE (NEW AND EXISTING DRAINS)” as listed in Schedule ‘A’ Part - VI representing __________ % ____________ percent Above / Below the lump sum price of ₹24,42,997.75 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - VII representing _______ % ________________ percent Above / Below the lump sum price of `4,16,979.95 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “COMPOUND WALL AND GATE” as listed in Schedule ‘A’ Part - VIII representing _________ % __________________ percent Above / Below the lump sum price of `6,95,485.61 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “ROAD / PATH (NEW PATH) / PAVEMENT AND RENEWAL / RESURFACING OF EXISTING ROAD” as listed in Schedule ‘A’ Part - IX representing ______ % _________________ percent Above / Below the lump sum price of ₹19,98,223.09 inserted by the MES in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - X representing ______ % _________________ percent Above / Below the lump sum price of ₹3,17,253.50 inserted by the MES in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - XI representing _______ % _______________ percent Above / Below the lump sum price of `80,15,024.96 inserted by the MES in Schedule ‘A’ Part - XI
Lump sum price worked out by the Contractor for “TELEPHONE & LAN” as listed in Schedule ‘A’ Part - XII representing _______ % _______________ percent Above / Below the lump sum price of `74,710.00 inserted by the MES in Schedule ‘A’ Part - XII
Lump sum price worked out by the Contractor for “LIGHTENING PROTECTION AND DG SET (EARHING)” as listed in Schedule ‘A’ Part - XIII representing _________ % _________________ percent Above / Below the lump sum price of `2,55,420.00 inserted by the MES in Schedule ‘A’ Part - XIII
Lump sum price worked out by the Contractor for “SUMMER APPLIANCES” as listed in Schedule ‘A’ Part - XIV representing _______ % _______________ percent Above / Below the lump sum price of `22,116.00 inserted by the MES in Schedule ‘A’ Part - XIV
Schedule 'A' Part-XV This Schedule is not prepriced by MES and the rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 16.00 to 143.
ADDITION / ALTERATION FOR EXISTING BUILDINGS Supply and fixing 10mm thick toughned glass as in hinged doors, partitions, automatic doors and similar work including cuttings to shape willing holes required including necessary emblems and designs engraved etc, complete all as specified and directed.
Supply and fixing PVC (SWR) pipes double socketed of 75 mm dia in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
Supply and fixing PVC (SWR) pipes double socketed of 110 mm dia in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
Supply and fixing PVC (SWR) bends 75mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) bends 110mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) branch piece, single 'Y' equal of unequal 75mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) branch piece, single 'Y' equal of unequal 110mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) floor trap plain with gratings including jointing with solvent cement 75mm dia outlet complete all as specified and directed.
Material and labour for Forming 12mm thick expansion joints filled with pre formed bituminous filler and top 30 mm primed and sealed with ceiling compound grade 'A' thickness of concrete slab 250 mm complete all as specified and directed.
Supply and fixing venetian blinds vertical type of 100mm wide straps with all fittings to be matched with existing pattern and taking down old venetian blinds complete all as specified and as directed.
Material and labour for epoxy flooring system (4 mm thick) the systems consist of necessary surface preparation such as cleaning dust free followed by supply and application of cipoxy-11 / equivalent (100 microns) with help of notch trowel, applying one coat of screed (cipoxy-17 primer + FQ sand / equivalent with help of hand driller and applying over the primer coat at an avg thickness of 1.8mm after getting dried grind the surface with paper grinding wheel, applying one coat of sealer of cipoxy-11 (11 mircons) / equivalent to remove dust from the screed if any and applying epoxy finish top coat floor top 1000 (1mm) as top coat with glossy and smooth finish as per instructions of Engineer-in-Charge.
Material and labour for mechanical cleaning of surface to make it free from any bituminous residue / dirt, oil and grease etc all as directed by the GE (I) / Engineer-in-Charge. (b) M&L for cracks treatment by cutting open cracks and cleaning it from dirt, loose materials etc and filling with polyurethane based sealant with and including application of PU based primer all as directed by GE / Engineer-in-Charge. (c) M&L for applying water based polyurethane modified dispersion (single component cold applied, non toxic, VOC compound) in 03 coats including 01 coat of primer of same material after dilution of water at 50% or specific primer matching same material as per manufacturer specification and as directed by GE (I) / Engineer-in-Charge.
Properties of poly urethane based chemical shall confirm to following Technical Parameters: - (i) Highly elastic. (ii) UV resistance. (iii) Adhesion to concrete > 1N/Sqmm. (iv) Tensile strength not less than 2.0N/Sqmm for free film. (v) Elongation - not less than 300% (vi) Solid content by weight - not less than 60%. (vii) Air/water permeability BSEN 12390 at 5 bar-72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0mm. (viii) Accelerated weathering (ASTM 453): Pass 1000 hours. (ix) Reaction to fire - non inflammable.
Notes: - (i) To be applied by the Rep of manufacturers authorized applicator only. Contractor has to provide manufacturer’s test certificate for the above mentioned Technical parameters and purchase Vrs. (ii) Removal of existing treatment to be paid separately. (iii) Roof top to be ensured to avoid water ponding. (iv) For accessible terrace and inaccessible terrace, 300mm height of vertical surface / parapet wall to be treated with same specification of slab. Make: Bostic, Berger, Fosroc, Sika, Asian or any other make approved by E-in-C’s Branch for PU based water proofing treatment.
Cleaning of loose scales and corrosion deposits from exposed reinforcement with steel wire brush or any other mechanical means of exposed steel after removing loose / damaged concrete complete all as specified and directed.
Material and labour for applying one coat of anti corrosive agent NITOZINC primer on exposed steel surfaces (new & old) making sure the surfaces are properly coated complete all as specified and directed.
Material and labour for Epoxy resin concrete bonding agent NITOBOND EP on old exposed concrete surface for bonding new cementitious materials to existing cementitious surface complete all as specified and directed.
Material and labour for pressure grouting 25mm thick including any temporary shuttering to edges with cement mortar 1:2 complete all as specified and directed.
Material and labour for pressure grouting 40mm thick including any temporary shuttering to edges with cement mortar 1:2 complete all as specified and directed.
Supply and applying specialized acrylic elastomeric caulking compound treatment to cracks of walls at all heights and levels as per instruction of Engineer-in-Charge.
Supply and fixing PVC ply, 18mm thick for use in kitchen cabinet, cabinet shutters and front of drawers duly fixed with solvent adhesive, shaped to receive glass / steel baskets fixed in position with and including provision of all necessary fixing arrangemens i.e., anchoring to walls with anchoring bolts of suitable length / screws as applicable, complete all as specified and directed.
Material and labour for Sand filling below and sites of foundation as cushioning including polythene film complete all as specified and directed.
INTERNAL ELECTRIFICATION Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulators sockets etc, to be measured separately) removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc, complete all as specified and directed.
Material and labour for point wiring with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit with modular switch, modular plate suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc, as required controlled by one switch complete all as specified and directed.
Supply & fixing wall mounted LED 20 watts, batten type fitting for surface and pendant application, 230 voltas with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver with connector block etc complete with all accessories internally pre wired and necessary mounting arrangements with PVC block and connection from ceiling rose to fitting complete including dismantling the existing unserviceable fitting complete all as specified and directed.
Supply & fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply & fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply & fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply & fixing LED street light 35/36 W IP 65 suitable for fixing on the building wall complete with GI bracket and making electrical connections as required complete all as specified and directed.
Supply & fixing exhaust fan, steel body AC single phase, 230V of size 300m sweep with blades and frame and louvers complete all as specified and directed.
Supply & fixing exhaust fan, steel body AC single phase 230V of size 380m sweep with blades and frame and louvers complete all as specified and directed.
Supply & fixing Air circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed.
Supply & fixing VTPN MCCB DB 8 way, 415V, 50Hz, AC, sheet metal enclosure, double door, IP 43 protection suitable for MCCB 4 pole upto capacity 100 Amps as incomer and SP/TP MCB's as outgoings comprising of 200 Amps busbar rating, neutral bar, duly powder coated painting and fixed flush in wall and making good the disturbed surfaces to match with existing surface and making electrical connections using suitable sizes of copper thimbles / lugs including taking down old unserviceable item complete all as specified and directed.
Supply & fixing VTPN MCCB DB 8 way, 415V, 50Hz, AC, sheet metal enclosure, double door, IP 43 protection suitable for MCCB 4 pole upto capacity 100 Amps as incomer and SP/TP MCB's as outgoings comprising of 200 Amps busbar rating, neutral bar, duly powder coated painting and fixed flush in wall and making good the disturbed surfaces to match with existing surface and making electrical connections using suitable sizes of copper thimbles / lugs complete all as specified and directed.
S&F, VTPN MCCB DB 4 way, 415V, 50Hz, AC, sheet metal enclosure, double door, IP 43 protection suitable for MCCB 4 pole upto capacity 100 Amps as incomer and SP/TP MCB's as outgoings comprising of 200 Amps busbar rating, neutral bar, duly powder coated painting and fixed flush in wall and making good the disturbed surfaces to match with existing surface and making electrical connections using suitable sizes of copper thimbles / lugs including taking down old unserviceable item complete all as specified and directed.
S&F, VTPN MCCB DB 4 way, 415V, 50Hz, AC, sheet metal enclosure, double door, IP 43 protection suitable for MCCB 4 pole upto capacity 100 Amps as incomer and SP/TP MCB's as outgoings comprising of 200 Amps busbar rating, neutral bar, duly powder coated painting and fixed flush in wall and making good the disturbed surfaces to match with existing surface and making electrical connections using suitable sizes of copper thimbles / lugs complete all as specified and directed.
Supply & fixing MCB TPN 40 to 100 A, 415 V 'C' curve in the existing MCB DB complete with connections, testing and commissioning etc, of 63A capacity complete all as specified and directed.
Supply & fixing sheet metal MCCB enclosure TPN double door type AC 415 V with MCCB 63 to 100 Amps, 4 Pole, 10 KA as incomer flush to wall including taking dwon old one complet and making good of distructed surface including taking down old one complete all as specified and directed.
Supply & fixing sheet metal MCCB enclosure TPN double door type AC 415 V with MCCB 63 to 100 Amps, 4 Pole, 10 KA as incomer flush to wall including taking dwon old one complet and making good of distructed surface complete all as specified and directed.
Supply & fixing MCCB 4 pole, 100 A, 16 KA, 415 V fixed type suitable for fixing in VTPN MCCB DB complete with electric connections as required complete all as specified and directed.
Supply & fixing MCCB 4 pole, 125 A, 16 KA, 415 V fixed type suitable for fixing in VTPN MCCB DB complete with electric connections as required complete all as specified and directed.
SEWAGE DOSPOSAL Construction of RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design mix in wall, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole opening with cover connection etc, complete with effective depth 1.5 mtr and overall depth 3 meter for 50 users complete all as specified and directed.
Construction of Soakage well excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25/SFRC cover, interconnection pipes RCC/DWC complete filled with brick bats of size 1.80 mtr dia and 3.0 Mtr depth complete all as specified and directed.
COMPOUND WALL AND GATE Supply and fixing, stainless steel 3D letters using 304 SS grade of height not exceeding 30cm with necessary stud fixing in wall, SS mate, glossy, titatanium coated steel mirror finish complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply, erecting, testing & commissioning of transformer 1000 KVA capacity outdoor type, step down 11/0.433 KV, HT with 3 phase and LT with 3 phase, 4 wire system, 50 Hz, double wound copper with ON load tap changer with tapping range +10% to -10% in taps 1.25%, energy efficient level II, confirming to IS 1180 (Part-I 2014 amendment No. 04), oil immersed naturally cooled, standards IS-2026. Specification for distrubution transformers IEC 76 IS-1180. The windings of the transformers shall be connected Delta on the primary side and Y (Star) on the secondary side. The vector group shall be Dyn. II. The temperature rise over ambient shall not exceed the limits top oil temperature rise measured by thermometer : 35 °C, winding temperature rise measured by thermometer 40 °C.
(a) Mounting : Floor mounted (b) Type of cooling : ONAN (c) Load losses at 50% and 100% I) The following standard fittings shall be provided: (a) Rating and terminal marking plates non detachable - 02 Nos. (b) Earthing terminals with lugs - 02 Nos.
(c) Oil level gauge indicating three positions of oil marked as follows: Minimum 5 Deg.C, 30 Deg.C, Maximum 98 Deg.C (d) Lifting lugs - 04 Nos. (e) Silicagel breathing device of weather proof design - 01 No. (500 gms. capacity) (f) Drain pipe of adequate size at the corner from bottom of the tank to the top cover where it is duly bent - 01 No. (g) Oil filling hole having 1-1/4 thread (with cover) on the transformer body / conservator - 01 No.
(h) Bimetallic terminal connectors on the HV/LV bushings as per drawing enclosed - 07 Nos. (j) Thermometer pocket - 01 No. (k) Platform mounting channel - 02 Nos. (l) HT/LT bushings - 03 Nos. on HT & 04 Nos. on LT, (LT & HT bushings shall be provided with 3 brass nuts & 2 brass washers). (m) Explosion vent - 01 No. (n) Off-circuit tapping switch with locking arrangement - 01 No. (o) Rollers : 04 Nos. of sufficient size. (p) Cable termination box both HV & LV side. (q) Separate Neutral Terminal. (r) Raditors. (s) painting : PU light Gray. (t) 02 years guarantee embossed plate welded below name plate. (u) Transformer foundation and civil works as per manufacturers recommendation. The rate is deemed to be included in the unit quoted rate.
II) Transformers shall be subjected to routine tests at the manufacturer’s works. (i) Measurement of winding resistance [IS 2026 (Part-I)]. (ii) Measurement of voltage ratio and check of voltage vector relation ship [IS 2026 (Part-I)]. (iii) Measurement of Impedance voltage / short circuit impendence and load loss [IS 2026 (Part-I)]. (iv) Measurement of No Load loss and current [IS 2026 (Part-I)]. (v) Measurement of Insulation resistance [IS 2026 (Part-I)]. (vi) Induced of over voltage with stand test [IS 2026 (Part-3)]. (vii) Separate source voltage withstand test [IS 2026 (Part-3)]. (viii) Impulse voltage test: [IS-2026 (Part-III)]. (ix) Temperature rise tests [IS 2026 (Part-II)]. (x) Short Circuit test [IS 2026 (Part-I)].
Supply, install, testing & commissioning of indoor type 11 KV HT Vacuum Circuit Breaker 800 Amps, 26.3kA for 3 sec STC panel comprising of VCBs incommer - 01 No and VCBs outgoing - 01 No complete alongwith metering, protection system Vacuum Circuit Breakers, draw out type single phase motor charged spring closing mechanism (230V AC), dust and vermin proof, fully interlocked, vertical isolation, indoor truck type with trip-free mechanism with mechanical ON/OFF indicators, earthing terminals, automatic safety shutters, insulated 3 pole copper busbar of adequate size, CT, PT, Numerical Relays, Metering, Indication, power and control wiring, interconnections, earthing truck, Power pack (suitable for 15-30 minute backup) conforming to IS/IEC 62271-200 & IS/IEC 62271-100 with latest amendments comprising of the following accessories complete all as specified and directed.
Note: (i) Vacuum interrupter bottle, Vacuum Circuit breaker, Main Numerical Relay & HT Panel shall be of reputed make of VCB, VIB, numerical relay in whose name type test reports will be submitted. (ii) Vacuum circuit breaker and HT panel shall be of same make only. (iii) HT Panels to be manufactured, tested, dispatched from OEM factory in whose name type test reports shall be furnished. Panels manufactured by system integrators / franchise partners of OEM are not acceptable. (iv) Switchgear panel shall be type tested for internal arc AFLR 26.3kA for 1 sec for all 3 HT compartments i.e., Busbar, CB and cable compartments. Individual type test reports with results clearly mentioned shall be furnished alongwith make approval. (v) Panel construction shall be made up of Aluzinc material for higher strength and also to avoid effects of corrosion / rusting. CRCA sheet can be used for front doors and end cover only.
(vi) Vacuum Circuit breaker shall comply to Electrical Endurance-E2 class, Mechanical Operations - M2 class, Capacitive Switching duty - C2 class in conformance to IEC 62271-100. (vii) Provision shall be made for extentendable of bus bar section in the proposed VCB to meet any future requirements of respective substation, so that future VCBs can be added as a outgoing VCBs only and if any accessories required (common to switchboard) shall be supplied without any extra cost to the department. Make: ABB (Leangear ZN1) / Schneider (PIX) / Siemens (NX Air) / Lauritz & Knudsen formely (L&T).
Incommer VCBs: 11 KV, 800 A, 26.3 kA/3sec. Vacuum Circuit Breakers shall be horizontal electrical drawout type, metal clad floor mounting panel and of manually and motor operated spring charge; position limit switches with minimum 6 NO + 6NC breaker auxiliary contacts. Current transformer cast resin type 11 KV, CT ratio: 200-100/5/5A Core 1: Class 1.0 with 10 VA burden for metering, Core 2: Class 5P10 with 10VA burden for protection - 03 Nos and Potential transformer cast resin type 11kV/√3/110V/√3/110V/√3 Core 1: Class 1.0, Core 2: Class 3P, 50VA burden and HT fuse at the primary and MCB at the secondary of the PT - 03 Nos.
Note: Provision be made for extentendable of bus bar section in the proposed VCB to meet the any future requirements of respective substation so that future VCB can be added as a outgoing VCB only with the 4 line up panel as per IE rules. Additional accessories (common to switchboard) shall be supplied.
Supply, install, testing & commissioning of indoor type 11 KV HT Vacuum Circuit Breaker 630 Amps / 800 Amps, 26.3kA for 3 sec STC panel comprising of VCBs incommer - 01 No and VCBs outgoing - 02 Nos complete alongwith metering, protection system Vacuum Circuit Breakers, draw out type single phase motor charged spring closing mechanism (230V AC), dust and vermin proof, fully interlocked, vertical isolation, indoor truck type with trip-free mechanism with mechanical ON/OFF indicators, earthing terminals, automatic safety shutters, insulated 3 pole copper busbar of adequate size, CT, PT, Numerical Relays, Metering, Indication, power and control wiring, interconnections, earthing truck, Power pack (suitable for 15-30 minute backup) conforming to IS/IEC 62271-200 & IS/IEC 62271-100 with latest amendments comprising of the following accessories complete all as specified and directed.
Note: (i) Vacuum interrupter bottle, Vacuum Circuit breaker, Main Numerical Relay & HT Panel shall be of reputed make of VCB, VIB, numerical relay in whose name type test reports will be submitted. (ii) Vacuum circuit breaker and HT panel shall be of same make only. (iii) HT Panels to be manufactured, tested, dispatched from OEM factory in whose name type test reports shall be furnished. Panels manufactured by system integrators / franchise partners of OEM are not acceptable. (iv) Switchgear panel shall be type tested for internal arc AFLR 26.3kA for 1 sec for all 3 HT compartments i.e., Busbar, CB and cable compartments. Individual Type test reports with results clearly mentioned shall be furnished along with make approval. (v) Panel construction shall be made up of Aluzinc material for higher strength and also to avoid effects of corrosion / rusting. CRCA sheet can be used for front doors and end cover only.
(vi) Vacuum Circuit breaker shall comply to Electrical Endurance-E2 class, Mechanical Operations - M2 class, Capacitive Switching duty - C2 class in conformance to IEC 62271-100. (vii) Provision shall be made for extentendable of bus bar section in the proposed VCB to meet any future requirements of respective substation, so that future VCBs can be added as a outgoing VCBs only and if any accessories required (common to switchboard) shall be supplied without any extra cost to the department. Make: ABB (Leangear ZN1) / Schneider (PIX) / Siemens (NX Air) / Lauritz & Knudsen formely (L&T).
Incommer VCBs: 11 KV, 630 Amps/800 Amps 01 No incommer & 02 Nos. outgoing 11 KV 800 Amps, 26.3 kA/3sec. Vacuum Circuit Breakers shall be horizontal drawout type, metal clad floor mounting panel and of manually and motor operated spring charge; position limit switches with minimum 6 NO + 6NC breaker auxiliary contacts. Current Transformer cast resin type 11 KV, CT ratio: 200-100/5/5A Core 1: Class 1.0 with 10 VA burden for metering, Core 2: Class 5P10 with 10VA burden for protection - 03 Nos and Potential transformer cast resin type 11kV/√3/110V/√3/110V/√3 Core1: Class 1.0, Core 2: Class 3P, 50VA burden and HT fuse at the primary and MCB at the secondary of the PT - 03 Nos. Outgoings VCBs: 11 kV, 630 Amps/800 Amps, 26.3 kA/3sec VCB Panel, horizontal drawout type vacuum circuit breaker metal clad floor mounting panel complete with manually and motor operated spring charge; position limit switches with minimum 6 NO + 6NC breaker auxiliary contacts, Current transformer Cast resin type 11 KV, CT ratio: 100-50/5/5A core1: Class 1.0 with 7.5VA burden for metering, Core 2: Class 5P10 with 7.5VA burden for protection - 03 Nos.
Digital Multifunction meter with RS485 communication Cl 1.0. Numerical Relay (50, 51, 50N, 51N, 95) with IEC 61850 - 01 No. Master Trip Relay - 01 No. Auxiliary Transformer Fault Relay (63X, 49X) -03 Nos. TNC Switch - 01 No. Local / Remote Switch - 01 No. Anti-pumping relay - 01 No. 01 No Busbar earthing truck - 630/800 Amps non fault making type.
01 No Cable earthing truck - 630/800 Amps non fault making type. 02 Nos Rack in rackout handle. Note: Provision be made for extentendable of bus bar section in the proposed VCB to meet the any future requirements of respective substation so that future VCB can be added as a outgoing VCB only with the 4 line up panel as per IE rules. Additional accessories (common to switchboard) shall be supplied.
Supply, laying & testing HT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 120 sq mm complete all as specified and directed.
Supply, laying & testing HT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 150 sq mm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 150 sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm complete all as specified and directed.
Supply, laying, testing & commissioning in trenches / ducts, fixed on walls / panels of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100, volts grade, cross-sectional area of size 2 core x 10 Sqmm complete complete all as specified and directed.
Supply, laying, testing & commissioning in trenches / ducts, fixed on walls / panels of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100, volts grade, cross-sectional area of size 4 core x 16 Sqmm complete complete all as specified and directed.
Supply, laying, testing & commissioning in trenches / ducts, fixed on walls / panels of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100, volts grade, cross-sectional area of size 4 core x 25 Sqmm complete complete all as specified and directed.
Supply, laying, testing & commissioning in trenches / ducts, fixed on walls / panels of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100, volts grade, cross-sectional area of size 3.5 core x 35 Sqmm complete complete all as specified and directed.
Supply, laying, testing & commissioning in trenches / ducts, fixed on walls / panels of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100, volts grade, cross-sectional area of size 3.5 core x 50 Sqmm complete complete all as specified and directed.
Supply, laying, testing & commissioning in trenches / ducts, fixed on walls / panels of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100, volts grade, cross-sectional area of size 3.5 core x 70 Sqmm complete complete all as specified and directed.
Supply, laying, testing & commissioning in trenches / ducts, fixed on walls / panels of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100, volts grade, cross-sectional area of size 3.5 core x 95 Sqmm complete complete all as specified and directed.
Supply, laying, testing & commissioning in trenches / ducts, fixed on walls / panels of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100, volts grade, cross-sectional area of size 3.5 core x 240 Sqmm complete complete all as specified and directed.
Supply, laying, testing & commissioning in trenches / ducts, fixed on walls / panels of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100, volts grade, cross-sectional area of size 3.5 core x 630 Sqmm complete complete all as specified and directed.
(a) ACB draw out type 2000 A, 65 KA - 01 No (Incoming). (b) MCCB, 3P, 200 Amps, 36 KA - 01 No for 1A (O/G). (c) MCCB, 3P, 630 Amps, 50 KA - 01 No. (d) MCCB, 3P, 400 Amps, 36 KA - 01 No. (e) MCCB, 3P, 300 Amps, 25 KA - 01 No. (f) MCCB, 3P, 200 Amps, 25 KA - 01 No. (g) MCCB, 3P, 100 Amps, 25 KA - 01 No. (h) MCCB, 3P, 63 Amps, 16KA - 01 No. Note: All MCCB should be thermal magnetic release type and adjustable over load min 70-100%.
(a) ACB draw out type 2000 A, 65 KA - 01 No (Incoming). (b) ACB draw out type 1000A, 65 KA - 01 No for 1C (O/G). (c) ACB draw out type 1600 A, 65 KA - 01 No for 1B (O/G). (d) MCCB, 3P, 630 Amps 50 KA - 01 for AC. (e) MCCB 3P, 400 Amps 36 KA - 01 for APFC panel. (f) MCCB, 3P, 200 Amps 36 KA - 01 No. (g) MCCB, 3P, 160 Amp 36 KA - 01 No. (h) MCCB, 3P, 100 Amps, 25 KA - 01 No. (j) MCCB, 3P, 63 Amps, 16 KA - 02 Nos. (k) MCCB, 3P, 32 Amps, 16 KA - 01 No. (l) MCCB, 3P, 16 Amps, 10 KA - 01 No. Note: All MCCB should be thermal magnetic release type and adjustable over load min 70-100%.
(a) ACB draw out type 1600 A, 65 KA - 01 No (Incoming). (b) MCCB, 3P, 400 Amps, 36 KA - 01 No for AC. (c) MCCB, 3P, 200 Amps, 25 KA - 01 No. (d) MCCB, 3P, 125 Amps, 25 KA - 01 No. (e) MCCB, 3P, 63 Amps, 16 KA - 02 Nos. (f) MCCB, 3P, 32 Amps, 16 KA - 02 Nos. (g) MCCB, 3P, 16 Amps, 10 KA - 02 Nos. Note: All MCCB should be thermal magnetic release type and adjustable over load min 70-100%.
Supply, install, testing & commissioning of 16A, 415V TPN industrial type socket outlet with four pole and earth, metal enclosed plug top alongwith 16 A 'C' curve TPN MCB in sheet metal enclosure on surface or in recess with chain metal cover for the socket out let and complete with connection all as specified and directed.
Supply, install, testing & commissioning of 63A, 415V TPN industrial type socket outlet with four pole and earth, metal enclosed plug top alongwith 63 A 'C' curve TPN MCB in sheet metal enclosure on surface or in recess with chain metal cover for the socket outlet and complete with connection all as specified and directed.
Supply and fixing MCCB 630A, 50KA, 415V TPN, 50 HZ including sheet metal enclosure on surface or in recess complete with connection complete all as specified and directed.
Supply and fixing MCCB 315A, 50KA, 415V TPN, 50 Hz including sheet metal enclosure on surface or in recess complete with connection complete all as specified and directed.
Supply and fixing MCCB 400A, 35KA, 415V TPN, 50 Hz including sheet metal enclosure on surface or in recess complete with connection complete all as specified and directed.
Supply and fixing MCCB 200A, 35KA, 415V TPN, 50 Hz including sheet metal enclosure on surface or in recess complete with connection complete all as specified and directed.
S&F, MCCB 63A, 25KA, 415V TPN, 50 Hz including sheet metal enclosure on surface or in recess complete with connection complete all as specified and directed.
Supply and fixing MCCB 125A, 35KA, 415V TPN, 50 Hz including sheet metal enclosure on surface or in recess complete with connection complete all as specified and directed.
Supply and fixing MCCB 100A, 25KA, 415V TPN, 50 Hz including sheet metal enclosure on surface or in recess complete with connection complete all as specified and directed.
Supply and fixing MCCB 32A, 16KA, 415V TPN, 50 Hz including sheet metal enclosure on surface or in recess complete with connection complete all as specified and directed.
Supply and fixing MCCB 16A, 10KA, 415V TPN, 50 Hz including sheet metal enclosure on surface or in recess complete with connection complete all as specified and directed. Note for Sl item Nos. 81 to 89: All MCCB should be thermal magnetic release type and adjustable over load min 70-100%.
Supplying, errecting & fixing steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screw as specified type 410 SP-55 (9 mtr long) and providing 03 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of ploes in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" wide, complete all as specified and directed.
Supply and fixing LED street light fitting 70 Watts made up of pressure die cast aluminium housing with high power LEDs and polycarbonate cover as diffuser with IP 65 protection including fixing arrangement on wall by using GI bracket made out of GI pipe of suitable size and with neccessary GI clamps, nuts, bolts and GI flat iron clamp 40 x 6mm and making cable connection by providing 3 core copper conductor cable and removing old unserviceable fitting complete all as specified and directed.
Supply and laying of High Voltage insulating mats rubber mat Class B of 1 MTR x 2 MTR and 2.5mm thickness, confirming to new specification IS : 15652:2006 complete all as specified and directed.
Supply and laying of low Voltage insulating mats rubber mat Class B of 1 MTR x 2 MTR and 2 mm thickness, confirming to new specification IS : 15652:2006 complete all as specified and directed.
Supply and erection of Bolard garden lights 12 W warmwhite 230 volts 50 Hz including GI pipe complete all as specied and directed by Engineer-in-Charge.
Excavation by TRENCHLESS TECHNOLOGY: Boring of hole under earth, road, pavement, hard standing or any location as per site requirements by using ultra sounding technique and necessary machine in and including pulling of GI pipe of dia (not less than 150 mm) suitable for LT cable of size 400/3.5 core complete as per site from tapping source panel to end connections panel and testing in all respects all as specified and directed by Deptt. Note: (i) The LT cable and GI pipe shall be measured and paid separately as supply only under relevent of this schedule. (ii) The quoted firm is responsible for making good damaged electric cables or any type of cables / items in the enroute of boring, earth work wherever applicable and the cost for the same is included in the quoted rate and no extra amount shall be paid by the Deptt in this regards.
Supply and fixing cable route indicator fabricated from 40 x 40 x 6mm angle iron 450mm long, rivetted or welded with 100mm dia CI or MS round disc duly engraved HT cable in letters including grouted in ground with PCC 1:4:8 type D2 complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft / loose soil for foundation of poles, structures, stay rods, laying of underground cable etc and removing excavated earth up to to 50 mtr complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak size 300mm x 180mm x 40mm complete all as specified and directed.
Supply and spreading of dry river sand in trenches / transformer yard / two pole structure yard for cable protection complete all as directed by Engineer-in-Charge. Note: Punned thickness only shall be measured for payment purpose.
Supply and lay, GI pipe light grade 100 mm for cable protection complete all as specified and directed.
Supply, installation, testing & commissioning of LT Panel Board shall be from OEM authorised / franchise certified IEC 61439 approved total type tested of Automatic Power Factor Correction (APFC) capacitor panel having aggregate capacity 600 KVAR in 12 stage with micro processor based control, factory made indoor type, platform mounted suitable for 440 volts 3 phase 4 wire, 50 Hz AC supply system, having all duly insulated copper bus bars, dust and vermin proof, IP 54 class protection and made of 2 mm CRCA MS sheet and 40 x 40 x 6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej (Navtal) lock with 2 keys, intemal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 sqmm complete all as specified and directed and comprising of followings: -
Incoming: (i) ACB 4 pole 1000 Amps, 50 KA, 415V. Outgoing: (i) Power factor corrector relay 6 stage Microprocessor based, modular type, intelligent APFC relay capable of having self adjustment to any capacitor value suitable to maintain power factor between 0.85 to 0.95 with digital indication of power factor, preset parameters and having in built capability of indication and elimination of defective capacitor steps - 01 No.
(ii) Power Capacitor MPP-H type of under mentioned capacity: - (a) 100 KVAR - 02 Nos. (b) 50 KVAR - 06 Nos. (c) 25 KVAR - 04 Nos. (iii) Power contactor TP 40 Amps - 01 No. (iv) Power contactor TP 30 Amps - 01 No.
Note: The equipment offered shall be complete in all respects. Any material and components not specifically stated in this specification but which is necessary for trouble free operation of the equipment and accessories specified in this specification shall be deemed to be included unless specifically excluded. The equipment shall conform in all respects to high standards of engineering design and workmanship and shall be capable of performing in continuous operation.
Material and labour for PCC 1:2:4 type B1 using 20mm graded stone aggregates as in coping including use of form work (straight or curved), weathering, slightly rounded or chamgerged angles and throating, as directed complete all as specified and directed.
Supply and fixing Junction box with cover and outlets including aluminium bus bars four Nos with suitable holes for taping, GI Strap, washers, nut and bolts and all as directed by Engineer-in-Charge.
Supply and fixing PVC insulated 3 core round flexible copper cable 1100 V grade of size 2.5 sq mm complete all as specified and directed.
Supply and fixing in repairs automatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure suitable for upto 5KW load single phase comprising of 25 Amps SP MCB, 25A power contactor and 230V digital timer switch for controlling street lights, including angle iron base and stand for fixing the panel with suitable PCC foundation as per site requirement complete all as specified and directed. Note: Rate quoted shall be inclusive of necessary excavation & earth work and PCC foundation.
Supply and fixing Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for LT, 20 x 15cm size complete all as specified and directed.
Supply and fixingDanger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT, 25 x 20cm size complete all as specified and directed.
Material and Labour 4mm dia galvanised steel wire 100 x 100mm mesh (chain link fencing area not less than 100 Sqm) made up matress fixed to any type of standard rails straining bolts etc including excavation post holes every 2.20 mtr and size 400 x 400 x 400mm and fixed within and including provision of cement concrete 1:3:6 type C2, M&L for mild steel work such as angle iron in posts and gate (50 x 50 x 6mm 'L' angle) and 40 x 5mm flat & post hieight is 2.00mtr above GL and gate size is 1.5m x 1.5m with hinges and locking arrangement including cutting tops to shape, drilled holes for post, notching for wire etc flat iron fillets (for securing chain link fencing) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165, including applying two coats of synthetic enamel paint over a coat of red oxide primer and including mild steel bolt machine made with hexagonal heads at one end and screwed at other end to be fitted with washers and one nut exc 5 but not exc 10cm and dia of shank is 11 to 15mm complete all as specified and directed.
Note: The necessary drawing for the gate and fencing post details has to be approved by the GE (I).
TELEPHONE & LAN Supply and fixing LAN Socket as required complete all as specified and directed.
LIGHTENING PROTECTION AND DG SET (EARTHING) Supply and fixing single pointed air termination aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
Supply and fixing aluminium strip 25mm x 3mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed.
Supply and fixing Test point terminal block made of gun metal or phosphours bronze of size 75 x 75 x 25mm drilled and screwed including 03 Nos 8mm dia 25mm long hexognal head screws complete all as specified and directed.
SUMMER APPLIANCES Supply, installation, commissioning of water cooler partially stainless steel, electric driven single phase inbuilt RO having approx storage and nominal cooling capacity of 40/80 Litres per hour complete all as specified and directed.
Supply and fixing refrigerator, electric driven (single phase) capacity more than 300 Litres BEE 5 star rated complete all as specified and directed.
Supply and fixing Voltage stabilizer of capacity 5 KVA for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second complete all as specified and directed.
UPS Supply, install, testing & commissioning on-Line UPS 200 KVA, 3 phase input and 3 phase output with 45 mins backup with builtin isolation transformer complete with 200 AH batteries, battery terminals, battery sand and inter link cables and making all connections compete with switchgear complete all as specified and directed.
Supply, test, install & commissioning on-Line UPS 200 KVA, 3 phase input and 3 phase output with 25 mins backup with builtin isolation transformer complete with 200 AH batteries, battery terminals, battery sand and inter link cables and making all connections compete with switchgear complete all as specified and directed.
AIR CONDITIONING Supply and installation and testing of TOP DISCHARGE Variable Refrigerant Flow system with single DC Inverter Compressor with Invertor condenser fan motor, built in panel box with hinges for proper service has to be supplied with R-410a Refrigerant, compatibility with centralised control with black box function, plate type heat exchanger with pumpdown / pumpout function including control panel complete all as specified and directed.
Supply, installation, testing and commissioning of Variable Refrigerant Flow connected 4-Way Cassette with drain pump & Hi wall mount type Indoor units with cordless remote with the following nominal capacity.
1.5 TR - 4 - Way Cassette
2.01 TR - 4 - Way Cassette
2.8 TR - 4 - Way Cassette
3.2 TR - 4 - Way Cassette
3.9 TR - 4 - Way Cassette
REFRIGERENT NET JOINTS
Supply & laying of VRF 18/19 Gauge copper piping with Nitrile rubber insulation of 19 mm / 13 mm thick insulation for suction / liquid lines. The supports for the copper piping shall be carried @ 1.5 mts equal distance and proper clamping has to be carried out for the following size of copper piping: -
Supply & laying of shielded communication cable of 1.0 swmmx3 core between indoors and outdoors and the same to be provided in PVC conduit and proper terminations to be done at all inddor units complete all as specified and as directed.
Supply and laying 25mm dia CPVC Drain piping using water quality pipe with suitable fittings complete all as specified and as directed.
Installation, testing & commissionig of Cassette indoor units with proper Rod / Wall supports to avoid any kind of vibration complete all as specified and directed.
Supply and instaliing Pressure testing, Vaccum and Gas Charging complete all as specified and directed.
Supply and laying of 2.5 sqmm x 3 core copper flexible cable drawn through 25 mm PVC conduit complete all as specified and directed.
Supply and fixing of 8 way DBs with incoming MCB of 63 Amps and outgoing 6 Amps (connecting 3 indoor cassatte unit one MCB) for INDOOR UNITS complete all as specified and directed.
Supply and installation of out door type panel for ground floor and first floor with incomming of 250 Amps 4 pole MCCB and out going of MCCB of 63 Amps 4 pole of - 06 Nos (including 01 No spare) with independant AMPS METER FOR EACH OUT GOING (72HP) complete all as specified and directed.
Supply and installation of out door type panel for ground floor and first floor with incomming of 160 Amps 4 pole MCCB and outgoing of MCCB of 63 Amps 4 pole of - 04 Nos (including 01 No spare) with independant AMPS METER FOR EACH OUT GOING (36HP) complete all as specified and directed.
Supply and installation of out door type panel for ground floor and first floor with incomming of 100 Amps 4 pole MCCB and out going of MCCB of 63 Amps 4 pole of - 03 Nos (including 01 No spare) with independant AMPS METER FOR EACH OUT GOING (36HP) complete all as specified and directed.
Supply and laying of aluminum armoured cable 35 sqmm x 3.5 core for out door units panel to DB complete all as specified and directed.
Supply and laying of aluminum armoured cable 16 sqmm x 3.5 core for out door panel to DB complete all as specified and directed.
Supply and laying of 8 SWG copper wire for earthing from outdoor panel to outdoor units and DBs complete all as specified and directed.
Material and Labour for earthing complete with CRPI tested maintenance free chemical tripod earthing using 20mm copper bonded 3m long rod (03 Nos) using X-Zel Part-I & Part-II 20 KG each and Z-Earth 40 KG including interconnection with earth lead burried directly in ground (earth pit not less than 4.0m deep below normal ground level) with top edge of the electrode 1.5m below normal ground level connected to copper earth strip 25 x 3mm (upto 7.5m in length from the earth electrode) by means of bolts and nuts check nuts and washers of galvanised iron or steel all as specified including necessary excavation and earthwork in any type of soil strata, PCC (1:3:6) type C1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 8mm dia TMT bars @ 150mm c/c both ways etc complete and connected to earthing test point complete including testing on completion all as specified and directed.
Supply & laying of GI strip 32 x 6mm complete all as specified and directed.
Supply & install, hi wall split units indoor / outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with 5 Star rating and EER 3.2 of capacity complete all as specified and directed.
Supply and fixing Voltage stabilizer of capacity 5 KVA for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second complete all as specified and directed.
Taking down carefully existing split air conditioner unit 1.5/2 TR from any location without damaging and refixing the same in any location as directed duly servicing and making electrical connections etc, complete all as specified and directed.
Taking down carefully existing package type AC plant of capacity 10 TR complete with all acessories from any location without damaging and refixing the same in any location as directed duly servicing and making electrical connections etc, complete all as specified and directed.
Supply & Fix, Auto change over switch 240 V, 50Hz suitable for split AC's in Server Room 1 & 2, complete all as specified and directed.
ROLLING SHUTTER (MOTORIZATION) Supply, erect, testing & commissioning of motorization including motor & mechanisation eqpt for existing mechanical rolling shutter (any size upto 1MT weight) in one single unit with 1 Ton lifting capacity by replacing the rolling spring assembly with new cylindrical type rolling assembly and chain crank in absence of power complete with ball bearing and springs etc minimum cost of maintenance with single phase push button starter with all connection copper wiring complete, limit switches, control wiring with copper conductor including necessary dismantling / refixing of shutter, addition / alteration civil works complete and including provision of manual operation in case of power failure all as specified and directed.
Supply, erect, testing & commissioning of motorization including motor & mechanisation eqpt for existing mechanical rolling shutter (any size upto 0.5T weight) in one single unit with 0.6 Ton lifting capacity by replacing the rolling spring assembly with new cylindrical type rolling assembly and chain crank in absence of power complete with ball bearing and springs etc minimum cost of maintenance with single phase push button starter with all connection copper wiring complete, limit switches, control wiring with copper conductor including necessary dismantling / refixing of shutter, addition / alteration civil works complete and including provision of manual operation in case of power failure all as specified and directed.
DG SET Supply, installation, testing & commissioning of silent Diesel Engine driven, generating set 415 volts, 250 KVA / 200 KW 3 phase 0.8 power factor 50Hz, 1500 RPM, Liquid Cooled, With all complete all connected acessories in all respects for commissioning of the DG set, with CPCBIV approved and latest MOEF guide line Accoustic enclosure IP 23, self excited self regulated brushless AC generator installed including accoustic enclosure suitable for ambient condition at Hyderabad including AMF panel and confirming to condition under IS 4722/1460, BS 5514/2613/5000 ISO 8526/3046 with the following: -
Alternator - Standard design alternator, Power rating 250/200 KW, 3 Phase 4 wire, 415 Volts, 50 HZ, Power factor 0.8 (lagging) Current 348 Amps, net output at site after considering derating for per site conditions at 0.8 (lagging) power factor, 1500 RPM, Cooling Liquid cooled, Aspiration Turbo charged, air cooled self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class 'H' and voltage regulation of +1% at rated voltage from no load to full load, A1 the alternator shall be conforming to BS 2613/5000 and shall be in position to generate supply with frequency regulation with in +1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS-2613/5000/IS-4722.
Diesel Engine: Minimum 268 BHP capacity, multi stroke, 06 Cylinder, TurboCharged Diesel Engine suitable for 250 KVA coupled with alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder, multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessoires shall be as under: - Insulation class - 'H', Temperature rise class - 'H', Excitation - Self excited Regulation performance - The voltage is kept constant with + 1%, manual voltage adjustment with in + 5%, Frequency Regulation + 1% suitable size & suitable number of runs of UG copper cable (Control cable) from Alternator to AMF & RAW Power to AMF Panel is deemed to be include is quoted rate.
(i) Flywheel with housing (ii) Cooling System: Mounted radiator with fan and belts (iii) Cooling Water Pump: Centrifugal type belt driven (iv) Exhaust System: The minimum hight of the stack to be provided 3.5mtr more to adjacent building. (v) Starting System: Electric Self Starter with maintenance free batteries including battery charging alternative belt driven.
(vi) Batteries: 24 Volts DC electrical batteries of suitable AH rating, complete connected with copper cable PVC sheathed conductor multistranded leads of suitbale length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified and directed. (vii) Fuel tank of adequate capacity: As per OEM norms and specifications designed for above capacity of DG Set. (i) Turbo charger, pulse tuned exhaust manifold. (ii) Cooling System: Mounted radiator with fan and belts & guard, corrosion inhibitor coolent etc. (iii) Silencer: Residential type.
(iv) Exhaust System: Exhaust system complete with flexible stainless steel piping of suitable dia 3.5 mtrs above the adacent bldg as per OEM standard with necessary supports and proper insulation complete for safe exhaust without transforming vibration to the wall of the enclosure and proper insulation complete for safe exhaust without transforming vibration to the wall of the enclosure. (v) Starting System: Electric Self Starter with maintenance free batteries including battery charging alternative belt driven. (vi) Fuel injection system with fuel injectors, filters, houses, fuel injection solenoid switch and nozzels. (vii) Fuel tank of adequate capacity: As per OEM norms and specifications designed for above capacity of DG Set. (viii) Lub oil pump, filter and coller. (ix) Intake system: Air intake manifold with dry type air filters.
(x) Engine and alternator shall be mounted on common base frame with AVM pads. (xi) Mounted micro processor based control panel having standard features and display engine and electrical parameters. (xii) The engine supplied with first filling of oil of required quantity as recommended by OEM. (xiii) All deliverible shall be confirmed the norms established by CPCB. AMF Panel: Auto Main Failure (AMF) Panel out door type OEM make made out 3.15mm CRCA sheet weather proof powder coated conforming to IS 8623 & IP-54 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 wire AC 50 HZ having aluminum bus bar of capacity required to carry current at 110% load of 250 KVA DG Set with three phase and half neutral colour coded pre-wired with copper flexible cable. AMF panel shall house adequate capacity contactors for smooth transfer of load between mains and DG set. Panel shall be operated with three modes of operation. 1. Auto, 2. Manual, 3. Test.
Contactor of suitable capacity 3 pole with required Nos. as per OEM, TP contactor for netural for both supplies Suitable capacity of MCCB, 4 Pole for both supplies. CTs 150/5A for both the supplies. Push buttons. Indication Lamps. 2 over load + earth leakage relay Multi functional digital meter for KWH, KVA, KW, Amps, Volts, frequency, power factor etc. SMPS Battery charge 12V, with trickle and boost charging. ON/OFF Switch. Automatic / Manual Switch, Hooter, Voltage sensing relay. Six window anunciator for fault indications. Acoustic Enclosure: Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet metal will provide easy access for maintenance, repairs and operation. The enclosure is custom to suit conditions with the following features: -
(i) Custom built product for various equipments, with ensure the optimum performance without duration. (ii) 16SWG (1.6mm) thick CRCA sheet to be used for enclosure panel to ensure longer life against weathing action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absoption. Acoustic layers are supported by perforated sheets. (iii) Sheet metal component of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action. (iv) Special paint treatment with pure polyster powder / epoxy to be provided for better weather resistance. (v) Well designed ventilation system to be provided to put out the heat from the chamber efficiently. (vi) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used.
(vii) The DG set should be provided with the external emergency stop push button and fire alarm. (viii) A see through transparent window infront of engine panel to be provided for monitoring the parameters. (ix) Working space is to be provided around the equipment for easy maintenance / repairs.
(x) Necessary cut out provision for entry and exist of fuel lines cable to be incorported in the enclosure as per the requirement. (xi) See through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation. (xii) Ducting if required, bellows, mechanical hardware like locks, hinge, fasters etc to be provided. (xiii) Deliverables 75DB @ 1 meter at 75% load under free field conditions. The temp inside the enclosure will be with in limit and as per manufacturers recommendations above ambient temp. (xiv) The enclsoure should be provided with bulk head light fitting for inside illumination. exhaust pipe along with proper aluminium cladding shall be laid to a height of above the roof level. The rates for the same are to be included in the quoted rates. (xv) The batteries should be placed inside the enclosure inside the DG Set on a suitable insulated platform.
(xvi) Fuel gauge to be provided with the neck of fuel tank. (xvii) Tools as per manufacturers with the box. (xviii) Invents of suitable company be manufacture. (xix) The acoustic enclosure parts shall be of powder coated after pre treatment process. (e) Civil Work: All civil works including RCC / PCC platform 1:3:6 type C2 and related to foundations including of panel and equipments including of panel and equipments including making good and existing structure of disturbed during installation and commissioning of Gen Set, the depth of the foundation shall be minimum 300mm with anti vibration pads or as recommended by the manufacturer. The foundation drawing for DG set shall got be approved by Engineer-in-Charge before laying of foundation. The contractor has to obtain approval for RCC / PCC foundation for the DG set with the manufactures, rates shall be quoted accordingly with written certificate from the manufacturers for the same.
(a) The Emission limits of DG sets upto 800KW / 1000 KVA shall be incorporated as per the latest CPCB norms as published by the Gazette of India New Delhi dated 03 Nov 2022 vide S No. 716 Extraordinary Part-II Section 3 - Sub Section (i) and emission limits shall come into force from 01 Jul 2023. (b) The emission limits shall be tested through one of the five CPCB approved / recognized labs as mentioned below: - (i) Automatic Research Association of India, Pune (Maharashtra).
(ii) International Centre for Automative Technology, Manesar (Haryana). (iii) Indian Oil Corporation, Research and Development Centre, Faridabad (Haryana). (iv) Indian Institute of Petroleum, Dehradun (Uttarakhand). (v) Vehicle Research Development Establishment, Ahmednagar (Maharashtra). (c) The cost of incorporation of Emission Standards and testing is included in rate quoted by the contractor. (d) DG set manufactured prior to 01 Jul 2023 shall not be allowed / acceptable.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 300 sqmm complete all as specified and directed.
M/S GDR CONSTRUCTIONS (BID ID -3128831)
R. Wadhumal and Sons (BID ID -3129461)
INDGUARD ENGINEERS (BID ID -3130710)
vijay infraprojects pvt ltd (BID ID -3138999)
Shree Construction Co. (BID ID -3127744)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
151419655.pdf
Tender Document • 0.57 MB
151419656.html
Tender Document • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .