Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.0 LAccepted-AOC Y 49 Y BLOCK HAUZ KHAS SOUTH WEST DELHI NEW DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹90.2 L+₹19.3 L (27.2%)Rejected-Finance | L2 | Rejected-Finance Higher rates |
Tender Value
₹68 L
EMD Value
₹1.4 L
Closing Date
21 Apr 2021, 5:00 pmClosed
Executive Engineer
Estate Office, CCS HAU, Hisar
Extension of Estate Office Building at CCS HAU, Hisar (including PH and EI works)
2021_HRY_167894_1
3219
Open Tender
Civil Works
Works
180 days
CCS HAU
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,000
₹1.4 L
Yes
2 Jun 2021
7 Apr 2021
23 Apr 2021
8 Apr 2021
21 Apr 2021
8 Apr 2021
Amount
Civil work 1 to 130:- Earth work excavation in ordinary soil exclusive of compensation of earth- {HSR 6.2 (b)} (b) Earth-work undressed with a combined lead upto 15 metres including breaking of clods
Dressing of earthwork :- (i) New work or remodelling work {HSR 6.3(i)}
Earth work in excavation in foundations, trenches, etc .in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches ,stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres (HSR 6.6)
(a) Earth filling under floors with surplus soil, excavated from foundation and taken only from outside the building plinth, in 15 cm layers, including ramming watering and consolidating lead upto 30 metres {HSR 6.13 (a)}
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 m and lift upto 1.5 m (a) soft/loose soil {HSR 6.25(a)}
Dismantling brick work, tile masonry or tile lining and tile terracing {HSR 8.5(b) + Note} (b) in cement Ist storey
2nd storey
Dismantling concrete {HSR 8.6(e)+ Note} (e) reinforced cement concree with cleaning and straightening and cutting of bars if required. Ist storey
2nd storey
Removing door and windows (wood and steel) with chowkats by making recesses in walls when the wall is not to be dismantled doors. (HSR 8.18(a)} (a) door
Removing glazing fixed or openable (wood and steel) including chowkhat holdfasts and concrete blocks:- (a) Together with dismentling of walls {HSR 8.23 (a)}
Extra for smooth exposed concrete finish as desired which is not to be touched or plastered but is to be left as it comes out of the shuttering for sides and soffits of beams hunchings, girders, bressumers and lintels. {(HSR 9.7) (45% of labour rate)}
Extra for smooth exposed concrete finish as desired which is not to be touched or plastered but is to be left as it comes out of the shuttering for columns (square or rectangular or polygonal in plan) {HSR 9.9 (45% of labour rate)}
Extra for smooth exposed concrete finish as desired which is not to be touched or plastered but is to be left as it comes out of the shutting for corbel, parapets, fascias and other similar items.(45% labour rate of item No. 9.11)
Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth. (HSR 10.28)
Cement concrete 1:4:8 with stone aggregate 40 mm nominal size in foundation and plinth (HSR 10.39)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level (HSR 10.59 + Note) Ist storey
2nd Storey
Pre-cast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in kerbs and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work , placing and fixing in position, complete at the ground level or in first storey (HSR 10.77)
Pre-cast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in tiles and channels and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work, placing and fixing in position, complete at the ground level or in first storey (HSR 10.78)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respects (HSR 10.81+ Note) Ist storey
2nd storey
Cement concrete 1:2:4 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement , but including centring and shuttering, laid in position , complete in all respects. (HSR 10.82+ Note) Ist storey
2nd Storey
3rd storey
Cement concrete 1:2:4 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination more than 25 degree with RCC slab excluding steel reinforcement , but including centring and shuttering, laid in position , complete in all respects. (HSR 10.82+ Note) Ist storey
2nd Storey
3rd storey
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns,(square or rectangular) battens and lintels etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects. (HSR 10.86 + Note) Ist storey
2nd Storey
3rd storey
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in fascias parapets and other thin vertical sections, not covered by item nos. 10.82,10.86 to 10.88 not exceeding 10 cm thickness excluding steel reinforcement but including centring and shuttering , laid in position, complete in all respects (HSR 10.89+ Note) 1st storey
2nd storey
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects, (For work upto 1.5 metres below ground level) (HSR 10.90)
(a) Extra over item Nos. 10.79 to 10.94 , if 1:1.5:3 mix is used, instead of 1:2:4 {HSR 10.95 (a)}
Damp proof course 40 mm thick of cement concrete 1:2:4 using stone aggregate with 2 coats of bitumen 20/30 penetration at 1.65 kg per sqm laid hot and sanded. (HSR 10.114)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in pavements, roads, taxi-tracks and runways, laid to required slope and camber, including consolidation, finishing and tamping complete. (HSR 10.132)
First class brick work laid in cement sand mortar 1:6 in foundation and plinth (HSR 11.2)
First class brick work laid in cement sand mortar 1:4 in foundation and plinth (HSR 11.4)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level (HSR 11.7+ Note) Ist Storey
2nd Storey
3rd storey
11.43 cm thick brick wall laid in cement sand mortar 1:4 in superstructure {HSR 11.48(a)+ Note} Ist storey
2nd Storey
11.43 cm thick brick wall with every fourth course reinforced with hoop-iron laid in 1:4 cement stone dust (from crusher) mortar in superstructure. (HSR 11.51+ Note) Ist storey
2nd Storey
11.43 cm thick brick wall laid in cement stone dust (from crusher) mortar 1:4 in superstructure (HSR 11.53)
Providing 5.72 cm brick dalli facing with brick size 22.86 cm X 11.43 cm X 5.72 cm thick to be obtained after cutting of bricks laid in cement sand mortar 1:3 on RCC lintels, beams fascia etc. including centring and shuttering complete. (HSR 11.98 + Note) 3rd storey
Terracing consisting of tiles 22.86 cm X 11.43 cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and an other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13 + Note) Ist storey
2nd Storey
3rd storey
Providing and fixing cast iron rain water non pressure pipe, I.S.I. mark with ears with screw and wooden plugs fixed on wall face including filling joints with spun-yarn and cement mortar 1:2 excluding head and shoe, etc. {HSR 13.45(a)} (a) 100 mm dia pipe
Providing and fixing cast iron rain water non pressure pipe, I.S.I. mark with ears with screw and wooden plugs fixed on wall face including filling joints with spun-yarn and cement mortar 1:2 excluding head and shoe, etc. {HSR 13.45 (b)} (b) 150mm dia pipe
Extra over rate of item nos. 13.43 and 13.45(a) in case lead joints are used instead of cement joints {HSR 13.46(a)}
Extra over rate of item no. 13.45(b) in case lead joints are used instead of cement joints {HSR 13.46 (b)}
Providing and fixing C.I. plain bends in position with gutter, etc. {HSR 13.49(a)} (a) for 100 mm dia pipe
Providing and fixing C.I. plain bends in position with gutter, etc.{HSR 13.49 (b)} (b) 150 mm dia pipe
Top khurra 0.6 m X 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 (HSR 13.50)
Supplying and fixing in position G.I.pipe class 'B' spouts in chajjas and cantilevers. (13.55 (e) (e) 50 mm internal dia, G.I. pipe
Cement concrete 1:2:4 gola 10 cm X 10 cm quadrant along junction of roof with parapet wall finished smooth, where specially specified (HSR 13.64 )
Providing and fixing false ceiling with 12 mm thick Gypsum Board fixed on M.S. steel runners frame including cost of screws angles, cleats, rawel plugs with taping, filling with Gypsum compound and applying priming coat etc. complete in all respects (HSR 13.91)
Providing and fixing mineral fibre false ceilings tiles at all hieghts of size 595 x 595 mm of approved texture, design and pattern, the tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity K = 0.052 (-) 0.057 w/m k, Fire Performance as per (BS 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round gavanized iron section of 0.33 mm thick (galvanized @ 120 gsm) comprising of main T runners of 15 x 35 mm of length 3000 mm, cross T of size 600 x 600 mm suspended from celing using galvazied mild steel item (galvanizedd @ 80 gsm) 50 mm long 8 mm outerdiameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm, spaced at 1200 mm centre of centre along main 'T'. The suystem should rest on periphery walls/partitions with the heop of GI perimeter wall angle of wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all hieghts, The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-charge. with or without groves (HSR 13.92)
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling (HSR 14.1)
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping (HSR 14.4 + Note) (a) 2nd storey
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in flooring laid in any patterns as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles {HSR 14.89} Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS, RAK & SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in skirting / dado laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles {HSR 14.90} Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS, RAK & SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Providing and fixing ceramic tiles/ anti skid tiles of size 400 mm x 400 mm or above size of approved make in flooring, laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS, RAK & SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this. {HSR 14.91)
Providing and fixing 1st quality ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manufacturer) of approved make in all colour, shades except burgundy, bottle green, black of any size of approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement coarse sand mortar 1:3 and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete (HSR 14.92} (b) size of ceramic glazed tiles 300 mm x 450 mm
Providing edge moulding to 17-20 mm thick granite stone counters, vanities etc. including machine polished to edge to give high finish etc. complete as per design apprvoed by Engineer-In-Charge (Moulding) {HSR 14.98 (i)} (i) Single moulding
12 mm thick cement plaster 1:6 on walls (HSR 15.7+ Note) Ist storey
2nd Storey
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12) Ist storey
2nd Storey
3rd storey
Rough cast exterior cement plaster on walls with a mixture of sand sand gravel or crushed stone graded from 2.36mm to 12mm nominal size dashed over and including fresh plaster in 2 coats, first coat 10mm cement plaster 1:4 (1 cement, 4 sand) and finishing coat 10mm cement plaster 1:3 mixed with 10% finely ground hydrated lime by volume of cement including arises, chamfers and / or rounded angles not exceeding 80mm in girth. (HSR 15.18)
10 mm thick cement plaster 1:4 on underside of ceiling (HSR 15.52+ Note) Ist storey
2nd Storey
3rd storey
Cement pointing 1:2 deep variety on brick and tile work (HSR 15.60 + Note) 3rd storey
Striking joints in lime or cement on brick and tile walls {HSR 15.69(a)}
Cement pointing 1:2 flush on flat brick flooring (HSR 15.71 + Note) Ist storey
2nd Storey
3rd storey
Cement pointing on stone slab pavement with cement mortar 1:2 (HSR 15.73)
20 mm thick cement plaster damp proof course 1:3 with 2 coats of bitumen at 1.65 kg per sqm laid hot and sanded :- (HSR 15.77 (a) Vertical
20 mm thick cement plaster damp proof course 1:3 with 2 coats of bitumen at 1.65 kg per sqm laid hot and sanded :-{HSR 15.77 (b)+ Note} (b) Horizental Ist storey
2nd Storey
3rd storey
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead , linseed oil, varnish and chalk mitti including finishing the surface to required finish complete (HSR 16.1)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping, etc. (HSR 16.2)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 16.3)
Applying priming coat with metal primer on new steel or iron work including preparation of surface. (HSR 16.9)
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces (HSR 16.25)
Distempering with washable oil bound distemper (of approved manufacture) two coasts excluding priming coat on new work (HSR 16.57)
Providing two coats of exterior acrylic emulsion paint . {HSR 16.79 (b)} (b) 1st quality
Providing and applying two coats of white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc., complete (J.K/ Birla make). (HSR 16.81)
Commercial hard wood such as hollock, champ, chikrassy and chaplash ,etc.,(non coniferous timber other than teak conforming to I.S. specification No. 1003 kiln seasoned), (HSR 17.30 (a) + Note) a) 35 mm thick (12 mm thick BWR Grade-II ply wood panel) Note: Nothing shall be paid extra for additional vertical style (any size) if required by the Architect or by the Engineer-in-Charge)
Proving and fixing 35 mm thick glazed door and windows shutters of commercial hard wood such as hollock, champ, chikrassy and chaplash, etc. ( non-coniferous timber other than teak confirming to I.S. specifications No. 1003 kiln seasoned), with vertical styles and rails, as specified in the statement no.1 ( attached in the end of this chapter), with glass panes of 4 mm thickness , tongued and grooved including the cost of iron hinges , screws, chocks/cleats, stops , etc., complete fixed in position excluding the cost of tower bolt and handles but including the labour for fixing the same {HSR 17.30(a)+17.24(c)} (b) 35 mm thick ( 4 mm thick glass panes)
Providing and fixing commercial type block board, plain lining, but jointed, including wooden plugs (teak) placed at 45 cm to 60 cm centres, complete with necessary nails (frame work shall be payable extra)- (HSR 17.49) (a) 25 mm thick
Providing and fixing 12 mm thick and 150 mm wide pelmet of commercial ply wood without 25 mm dia teak wood curtain rod and brackegts including fixing with 25 mm x 3 mm M.S. flat, 10 cm long and plugs. (Teak) etc. complete. {HSR 17.63 (-) 17.89 (c)}
Providing and fixing 150 mm hasps and staples with necessary screws, etc., complete- (HSR 17.78(b) (b) aluminium
Supplying and fixing hydraulic door closer, I.S.I. mark, with necessary screws , etc., complete- {HSR 17.82 (c )} (c) I.S.I. designation No. III ( size of door 851 mm to 1000 mm)
Providing and fixing sliding bolt with nuts and screws, etc., complete. {HSR 17.83 (b) (ii)} (b) Aluminium (ii) size 250 mm X 16 mm
Providing and fixing 0.50 mm thick aluminium sheet, including cost of necessary screws, etc., complete (HSR 17.87)
Factory manufactured solid flush door shutters, with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops, etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)- (HSR 17.93(a)} (a) commercial veneering with vertical grains or cross bands and face veneer on both sides commercial facing with laminated core and lipped edges :- (i) 25 mm thick
(iii) 35mm thick
Wrought iron and mild steel (using angles, flats square bars. tees and channels) ladders, grills, gratting frames, window guards, iron door openable or fixed stair case or parapet or any other type of railing , gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position (HSR 18.12)
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC incluidng straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position, complete in all respect for all heights/depths/storeys/basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separtely for different diameters as actually used in work excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)
Supplying openable steel doors and windows, of standard steel sections, joints mitred and electrically flash welded including provision for arrangement of receiving handles, peg stay, catcher will also be welded with the frame and providing and fixing pressed steel projected hinges, iron lugs, glazing clips (excluding wooden shutters, glazing and fittings such as handles, peg stay and catcher etc.) and finished with one coat of ready mixed red lead non setting primer (HSR 18.24)
Fixing steel windows in walls with lugs, embedded in 15 cm x 11.43 cm X 7.5 cm cement concrete blocks, of 1:3:6 mix, excluding fixing of glass panes but including cost of cement concrete for lugs (HSR 18.29)
Supplying and fixing glass panes including special metal sash putty of approved make {HSR 18.30 (b)} (b) Glass panes 4 mm thick, exceeding 40 sq dm areas
Providing and fixing 15 mm to 18 mm thick Z-Black granite stone (polished) on worktop laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing C.I. grating over 100 mm dia rain water pipe, fixed in position, complete in all respects. (NS)
Providing and fixing C.I. grating over 150 mm dia rain water pipe, fixed in position, complete in all respects. (NS)
Earth filling under floors with dune sand (tiba sand), brought from outside (any lead), in 15 cm layer including laying, dressing, watering ramming, consolidating, excavation, carriage, loading, unloading and compensation, etc., complete (NS)
Earth filling under road/parking with dune sand ( tiba sand), brought from outside (any lead) in 25 cm layers including laying, dressing, watering, rolling with road roller to specifications/ consolidating, excavation, carriage, loading, unloading and compensation, etc., complete in all respects. (NS)
Providing, diluting and injecting chemical emulsion for pre-constructional anti-termite treatment and creating a continous chemical barrier under and all round the column pits, wall trenches, basement excavation, top surface of plinth filling junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits etc., complete as per PWD specifications (plinth area of the building at ground floor only shall be measured of payment (NS) (the material i.e. Chlorphriphos Emulsifiable concentrate 20% with 1% conentration shall be arranged by the contractor)
Providing and fixing 3’-0” high staircase railing consisting of 50 mm x 20 mm M.S tube (12 guage or any other guage) as hand rail and 20 mm x 20 mm M.S square pipe (12 guage or any other guage) as balusters including cutting, welding, grinding of joints, making holes in floor/step and filling the same with lead, priming coat and painting work etc. fixed in position, complete in all respects as per drawing and design or as directed by Engineer-in-Charge. (NS)
Providing and fixing 19 mm thick BWR grade-II block board (ISI mark) shutters for cabinet including cost of iron hinges, screws etc., fixed in position, complete in all respects as per drawing and design or as directed by Engineer-in-Charge. (NS)
Providing and fixing marble strips of size 14 mm to 17 mm and 125 mm wide in cement concrete pavement fixed in position, complete in all respects as per drawing and design or as directed by Engineer-in-Charge. (NS)
Providing and fixing factory manufactured cement concrete 1:2:4 kerb finished smooth and of size 1’-0” x 1’-0” x 0’-6” of required shape and design fixed at ground level along with road parking, complete in all respect as directed by the Engineer-in-Charge but excluding cost of cement pointing (NS)
Providing and fixing 45 mm wide solid and 30 mm wide jali Zebra type (PCL rainbow or any other equivalent make as approved by Engineer In charge) horizontal venetian blinds of required size and shape, fixed in position including rawl plugs and screws etc. complete in all respect. (NS)
Removing of old glass panes of any thickness on size from matel frame and shifting the same to store, complete. (NS)
Providing and fixing 25 mm dia stainless steel curtain rods weighing 0.560 kg/meter with brackets & side covers (balls) of vista make, clamps, plastic gutties/rawl plugs etc., complete in all respects. (NS)
Providing and fixing 54 mm thick double leaf wooden door (main door) consisting of the following:- Frame work:-Conisiting of commercial hard wood (champ wood) outer and middle members of size 114 mm x 32 mm, lock rail of size 150 mm x 33 mm and bottom rail of size 225 mm x 33 mm. Finished portion:- Consisting of 1/4" thick champ wood strips fixed on 4 mm thick BWR Grade-II plywood (ISI mark) on both sides/faces in V shape. Including brass polished handles, aluminium tower bolts, spirit polish, iron hinges, nails and screws etc. fixed in position, complete in all respect as per drawing and design or as directed by Engineer In-charge. (NS)
Providing and fixing PVC wall paneling consisting of 7mm thick cactus make hollow , PVC U-section beading of size 25mmx8mmx12mm and PVC angle nosing of size 25mm x 25mm x 1.5mm including cost of PVC gutties, screws, jointed with polyfix (instant glue), complete in all respect as per drawing or as directed by Engineer-in-Charge. (NS)
Providing and fixing 15 mm to 18 mm thick Sardar Ali granite stone (polished) in flooring including matching grains laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing 15 mm to 18 mm thick Sardar Ali granite stone (polished) in skirting including matching grains laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in flooring/skirting, laid in any pattern as specified over base of adhesive of reputed brands such as Pidilite, Laticrete, Ferrouscrete & Valendure as per IS specification 15477-2004 and jointed with white cement slury mixed with pigment to match the shade of tiles excluding cost of tiles. (Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS & RAK, SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this. (NS)
Public health work 131 to 193:- Excavation for pipe lines running under pressure in trenches and pits, in streets & lanes including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, cutting trees and bushes, etc., refilling consolidation and watering of refill. In 15 cm layers and restoration of unmetalled or unpaved surface to its original condition, including the cost of dewatering of rain water, diversion of traffic, night signals, fixing caution boards, crossing over trenches for access to the houses, watching fencing, etc., and disposal of surplus soil outside and inside the town, involving lead up to one K.M. in ordinary soil:-(HSR 6.9(a)} (a) without tembering and shorting upto 1.5 metres depth
Excavation of trenches in streets, lanes or in open areas for storm sewer, sewers running by gravity and manholes to full depths as shown in drawing including shoring, timbering of poling boards, frame system type, dressing to correct sections and dimension, according to templates and levels, dewatering, provision for diversion of traffic, cutting trees and bushes, etc., night signals, profiles, pegs, sight rails, boning rods, crossing over trenches, for access to the houses, watching, fencing, etc., fixing and maintenance of caution boards, refilling of trenches, watering of refill, in 15 cm layers, ramming and restoration of unmetalled or unpaved surface to original condition and removal of surplus soil, from site of work, up to a lead of 1 K.M. in ordinary soil {HSR 6.10(a)} (a) for depth of excavation not exceeding 3 metres below ground level
Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth.(HSR 10.28)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.41)
Cement conc. 1:2:4 with stone aggregate 20 mm nominal size for reinforced conc. Work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centering and shuttering, laid in position, complete in all respects. (HSR 10.82)
Extra over item Nos.10.79 to 10.94, if 1:1½:3 mix is used instead of 1:2:4. {HSR 10.95(a)}
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level (HSR 11.7)
12 mm thick cement plaster 1:5 (HSR 15.6)
Steel work, fixed independently without connecting plates, including cutting hoisting and fixing in position in:- {HSR 18.1 (a)} (a) R.S. Joist
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC incluidng straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position, complete in all respect for all heights/depths/storeys/basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separtely for different diameters as actually used in work excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)
Labour for laying, jointing, fixing and testing G.I./P.V.C./W.I. pipe lines and specials tees, bends, sockets elbows etc. inside building and testing etc. complete including cutting threading. {HSR 28.18(b) (i)} INCLUDING COST OF SPECIALS (i) 15 mm internal diameter of pipe line
(ii) 20 mm internal diameter of pipe line
(iii) 25 mm internal diameter of pipe line
Extra for fixing and jointing union couplings in G.I and W.I pipe lines. (HSR 28.21 (a) (a) 15 mm internal diameter
(b) 20 mm dia
(c) 25 mm dia
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. (HSR 28.24 (b) (b) 22.86 cm thickness wall
Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including repointing, replastering, replacing bitumen and colour or white washing where required. {HSR 28.26(b)} (b) 115 mm thickness of roof of floor
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I pipelines laid in the ground or inside buildings including cartage from divisional stores or nearest railway station to site of works. {HSR 28.29 (b)} (b) 20 mm internal diameter
(c) 25 mm internal diameter
Making connection with the existing G.I branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. (HSR 28.34)
Constructing brick masonry inspection chambers sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/C.C. topping. 50 mm thick with 455 mm x 455 mm/ 455 mm x 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (HSR 29.84 (c) (c) size 600 mm x 900 mm inside ( with 455 mm x 610 mm cover and frame single seal pattern 1 weighing 38 kg with C.C. topping)
Extra for over 0.30 meter depth of inspection chamber:- {HSR 29.85 (c)} (c) 600 mm x 900 mm
Providing slat glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with is: 651 and their lowering, cutting, jointing and testing as desired in HSR item No. 29.38, 29.39, 29.40, including the cost of jointing materials as well as carriage, loading, unlloding stacking, handing, re-handling etc. complete in all respects to the satisfaction of Engineer-In Charge. (HSR 29.95) 150 mm internal dia
Providing and fixing 40mm G.I waste pipe embedded in walls or lead waste pipe weighing 4.46 kg/ metre and 3.0 mm thick up to floor level as required by the Engineer-in-charge including cost of union and plumber joint. (HSR 30.62)
Providing and fixing in position 15 mm i/d C.P brass bib cocks of best quality ( as required by the Engineer-in-charge) {HSR 30.75(a)} (a) Bib cock lond body.
Cutting chase in brick walls in cement or in floor for embedding G.I. or H.C.I. pipe lines and making good the same to its original condition {HSR 30.95(a) (a)size 75 mm X 75 mm
Providing and fixing in position automatic brass ball valves in tanks. {HSR 30.110 (b) (iii)} (b) With plastic ball (iii) 25 mm internal diameter
Providing and fixing HDPE WATER STORAGE TANKS of sintex, diplas O.K. Supreme make with covers/ lids marked with IS: 12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow & scour provisions with suitable plug on scour pipe including cost of nipples, washers, flanges for connections in tanks complete in all respects to the satisfaction of Engineer-in- Charge. (HSR 30.119) 1000 Ltr. Capacity
Supply of PVC pipe 6 kg/cm² pressure of ISI marked of Prince / Supreme/Skipper make (as approved by the Engineer-in-Charge). (NS) a) 90 mm o/dia size
(b) 110 mm o/dia size
Supply and fixing of PVC floor traps (Heavy duty) of 90 mm o/dia outlet of Prince /Supreme/Skipper make, complete in all respect. (NS)
Supply and fixing of PVC gully traps (Heavy duty) of 100 mm dia size ( 4") with cover and frame of Prince/Supreme/skipper make complete in all respect. (NS)
Supply of CPVC pipes (Heavy duty) of Prince/Supreme/Finolex/Skipper/Astral make (as approved by the Engineer-In charge). (NS) (a) 15 mm i/dia (20 mm o/dia) size
(b) 20 mm i/dia (25 mm o/dia) size
(c) 25 mm i/dia (32 mm o/dia) size
Supply of CPVC Union Couplings with brass internals of Prince/Supreme/Skipper make . (NS) (a)15 mm dia
(b) 20 mm dia
(c) 25 mm dia
Supply of CPVC ball valves with brass internals of Prince/Supreme/Skipper make . (NS) (a) 20 mm dia
(b) 25 mm dia
Providing and fixing in position Fore Front wall hung bowl (WC) SKU Code No. K-72838 IN-O of Kohlar Make, complete in all respect. (NS)
Providing and fixing in position Karess Vassel Lavatory SKU Code No. K-2764-T-I-O of Kohlar Make, complete in all respect. (NS)
Providing and fixing in position Pure clean seat cover Fore front SKU Code No. K-96001 of Kohlar Make, complete in all respect. (NS)
Providing and fixing in position Aleo Basin Mixer SKU Code No. K-72275- IN 4ND-CP of Kohlar Make, complete in all respect. (NS)
Providing and fixing Angle Value (July) crome polished SKU Code No. K-80154 IN-4-CP of Kohlar Make, complete in all respect. (NS)
Providing and fixing in position Inline Stop Valve SKU Code No. 16089- IN-CP of Kohlar Make, complete in all respect. (NS)
Providing and fixing in position C.P. Grid drain complementary SKU Code No. K-45432- IN-CP of Kohlar Make, complete in all respect. (NS)
Providing and fixing C.P. Brass (straight) Inline Stop Valve (concealed stop cock) SKU Code No. K-37340- IN-9-CP of Kohlar Make, complete in all respect. (NS)
Providing and fixing Bottal Trap SKU Code No. K-75823- IN-CP of Kohlar Make, complete in all respect. (NS)
Providing and fixing in position Patio Touchless Urinal with sensor SKU Code No. K-16321- M-O of Kohlar Make, complete in all respect. (NS)
Providing and fixing in position IN-WALL-Tank Pneumatic, SKU Code No. K-77027-IN-P-NA of Kohlar Make, complete in all respect. (NS)
Providing and fixing in position CP Face Plate Pabble (for in wall tank) SKU Code No. K-54131-N-P-CP of Kohlar Make, complete in all respect. (NS)
Providing and fixing Brackets & Bolts SKU Code No. K-1224238-OM-12 of Kohlar Make, complete in all respect. (NS)
Providing and fixing Connector Assessory pack SKU Code No. K-1046327-S of Kohlar Make, complete in all respect. (NS)
Providing and fixing looking mirror 5.0 mm thikc of size 4'-0" x 2'-6" mounted on asbestos sheet ground fixed in position by means of 4 Nos. C.P. brass screws and washers on rubber washers and rawl plugs embeded in wall or CP brass clamps with CP brass screws etc. complete in all respect. Make:- Saint Gobin/MODI/ATUL (NS)
Providing and fixig Towel rail 600 mm long of Jaquar Make Model No. ACN-1111-SM, complete in all respect. (NS)
Providing and fixing coat & hat hooks of Jaquar Make, Model No. ACN-1161-N, complete in all respect. (NS)
Providing and fixing in postion Poper holder of Jaquare Make, Model No. ACN-1153-S, complete in all respect. (NS)
Providing and fixing CP brass Jali 4" dia size of best quality with anti cockroch look, complete in all respect. (NS)
Providing and fixing of PVC specials of Prince / Supreme/Skipper make as per detail given below:- (NS) (a) 100 mm i/dia (4" i/dia) size Pipes (i) Bend Plain
(ii) Cowl
Supply and fixing in position stainless steel sink made of 1 mm thick Salem stainless steel sheet along with fittings of Blue Star/ Jayna make or equivalent as per AISI 304 (18/8), complete in all respect. (NS) Bowl size = 560 mm x 405 mm x 178 mm Overall size = 610 mm x 460 mm x 178 mm
Electrical work 194 to 272:- S/E of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. (HSR 31.13) (ii) Size 40 mm x 40 mm x 6 mm
Supply and erection of 3 mm thick mile steel sheet duly welded on existing MS angle iron frame for fixing the main switch etc., as required, duily painted with three coats of approved paint including one coat of red oxide. (HSR 31.14)
Supply and erection of blanking sheet in existing distribution board (HSR 31.16)
MINIATURE CIRCUIT BREAKER AND ISOLATOR:(HSR 31.17) Supply and erection of miniature circuit breaker/isolator 240/415 V in the existing distribution board including making necessary connections (a) Miniature Circuit Breakers of 9 K.A. breaking capacity (ii)6-32 amp. SP MCB
(ii) 32 amp. TPN MCB
(ii) 63 amp. TPN MCB
PIPE LAYING: Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required :-(HSR 31.21) (xxx) S/E of PVC pipe of 6 Kg. pressure, laid 1 metre below ground level complete including digging refilling of the trenchy with jointing etc. (a) PVC pipe 120 mm dia.
(c) PVC pipe 65mm dia.
EARTHING (HSR 31.22) (i) Earthing with G.I. earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. as required
(ii) Extra for charcoal or coke and salt for pipe earth electrode.
(xii)Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15mm dia G.I. pipe from earth electrode as required.
(xvi) Pdg and fixing 4.00mm dia GI wire on surface or in recess for loop earthing as require
UNDERGROUND CABLES (HSR 31.25) S/E of underground cable 1 metre below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (xxxi) 150 sqmm 3.5 core cable (armoured)
UNDERGROUND CABLES Supply and erection of underground cable loose in existing pipe or trenches complete with necessary connections.(HSR 31.26) (xLI) 25 sqmm 4 core cable (armoured)
(xliii) 50 sqmm 4 core cable (armoured)
(xxxi) 150 sqmm 3.5 core cable (armoured)
S/E of suitable compression type brass cable glands for underground cable (HSR 31.28) (iii) 25 sqmm to 50 sqmm cable 3 to 3.5 core.
(v) 120 sqmm to 185 sqmm cable 3 to 3.5 core.
Miscellaneous (HSR 31.35) (i) Supply of M.S. Pipe (B-Class) for suspension rod of ceiling fan including threading if required. (a) 15mm dia
(ix)Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of Engineer-in-charge of the work. (e) 25 sqmm
(g) 50 sqmm
(k) 150 sqmm
S/E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size excluding cost and erection of pipe (HSR 31.40) (i) Size 1.5 sqmm(3/0.81mm)
(ii) Size 2.5 sqmm(3/1.05mm)
(iii) Size 4 sqmm(7/0.85mm)
(iv) Cable size 6 sqmm(7/1.05mm)
(v) Cable size 10 sqmm(7/1.35mm)
S/E of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. Recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer-in-charge of the work (HSR 31.41) (v) 4-way TPN (Horizontal) (8+12)
(vi) 8-way, TP&N (Horizontal) (8+24)
S/E of PVC conduit pipe ISI marked (Medium) recessed in wall/ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work (HSR 31.44) (ii) 25mm dia
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 31.56) 10 amp. 1 way switch
20 amp.switch
10 amp. Socket
16 amp. socket
Fan regulator
Blinkng plate
Pdg. and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. (HSR 31.57) 1 & 2 Modules
3 Module
4 Module
8 Module
6 Modules
12 Modules
Supply, installation testing and commissioning of wall/free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2mm thick CRCA sheet, required hardware 3mm thick Bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar Bakelite sheet 3mm thick for separately cable alley to BBC from switch chamber extended solid copper bars upto cable alleys shall provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring (copper) and fuse protection (Only outer area on all sides shall be measured) (HSR 31.63)
Suppluy and erection of module case circuit breaker single pole/4 pole on wall on existing prdestal including boundaing to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction oof the Engineer-in-charge of work (HSR 31.69) (iv) 4 pole MCCB 6amp. to 63 amp
(v) 4 pole MCCB 100 amp
S/E/T/C of multicore telephone conductor 0.5 mm complete in all respect. ( HSR 31.78 ) i ) 2 Pair Telephone
S/E/T/C of cat-6 cable in existing PVc conduit /PVc channel complete in all respect with all labour and material required to complete the job in all respect. (HSR 31.80)
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod and regulator etc. {NS} i) 1200mm sweep. Make: Usha, Orient, Crompton.
S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white color) for AC's including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. (NS) Make;- Schneider/Crabtree/Athena
Supply and erection of propeller type AC ventilating fan (exhaust fan) with necessary earthing arrangements of fan with shutter complete in all respects Size 300mm(12”) sweep Make: Orient, Usha, orient, Havells. (NS)
Supply & Erection of 300 mm Sweep wall mounting fan with pull cord control for speed and oscillation3 years comprehensive warranty period including the cost of all petty material required to complet the job upto entire satisfaction of Engineer-in-Charge (NS) Make:- Orient/Havelles/Bajaj
S/E of Internet jack RJ-45 Modular complete in all respect Make:-D-link/Amp/Molex
S/E of Telephone jack Modular complete in all respect Make:-Anchor/D-link/Amp/Molex
S/E of surface/wall mounted ≤20W integrated LED 4 feet fitting with Epoxy Powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20 watt LED should be ≥ 2000 or above in cool day light (5700K to 6500K), Power factor >0.95, CRI >80, Average life >50000 hours. Complete with mounting Brackets & accessories as required with connections(Industrial) Make: Philips, Havells, Wipro, Bajaj. (NS)
S/E of recessed type 42 Watt full window glare free opal diffuse LED Panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 4600 or above in cool day light (5600K to 6500K), Power factor >0.95, CRI (Ra) >80, LED lamp Make- Cree, Nichia, Philops Lumiled Osram, Edison, LED Lamp efficacy > 130/m/w, Average life > 50000 hours, complete with all accessories as required with connections(Industrial) Make: Philips, Havells or Wipro etc. (NS)
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-410-A/R-32 suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:-(i) Cooling coil row -3 Nos.(ii) Air flow (CMH) -1100-1450 cum/ hr.(iii) Sound level (H/M/L)- 41/38/34/25(silent mode)(iv) Louvers swing- 3D + 3D Auto etc. complete in all respectMAKE :- O General/Toshiba/Mitsubishi (Heavy Industries) (five star rating) Model as approved by the Engineer-in-Charge. (NS)
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge ofV-Guard make ISI marked complete in all respect. (N.S.)
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 15.88mm(5/8") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit. (NS)
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)
Supply Installation testing & commissioning of 24 Port POE Access Switch with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Switch should offer Wire-Speed and Non-Blocking Switching with 24 10/100/1000 RJ45 PoE/PoE+ Ethernet ports and additional 4 SFP+ (1G/10G ) fiber based ports, Minimum 2 port Populated with 10G MMF. Access switch should support minimum 16K MAC addresses and minimum 4K active VLANs. Access switch should support up to 8 hardware queues per port Access Switch should support full Layer 2 features like STP, RSTP, LACP, ACL, QoS, IGMP v1/v2 from day 1. Access Switch should support minimum 1K IPv4 routes.The Access Switch should support IPv6 management features like IPv6 ping, IPv6 trace route, IPv6 Telnet, IPv6 TACACS, IPv6 and IPv6 RADIUS.Access switch should support minimum 4K ACL rules ACL per Switch.Access switch should support SNMP v1/v2/v3, SSH, NTP and web managementAccess switch should have 1G of RAM and 2G of Flash Memory.MAKE : RUCKUS/CISCO/HP
Supply Installation testing & commissioning of 10GBASE-SR,SFPP MMF LC CONNECTOR with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : BROCADE/CISCO/HP
Supply Installation testing & commissioning of Category 6 Patch Cord 7feet, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/Molex/belden
Supply Installation testing & commissioning of 24Port loaded Straight Jack pannel, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/Molex/belden
Supply Installation testing & commissioning of Horizontal PVC Cable Manager - 1U , including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/R&M
Supply Installation testing & commissioning of 18U Wall Mount rack with front glass door lockable, Fans 90 Cfm 230 Vac, PDU Horizontal 5Amp with 6 Schokets, Cantilever Tray-1U, Horizontal PVC Cable Manager and Hardware front panel Mtg. including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/NETRACK/VPRO
CCTV:-Supply Installation testing & commissioning of 4MP IP Network Dome Camera with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Image Sensor : 1/3” 4 Megapixel Progressive scan CMOS sensor or better ,Effective Pixels : 2688(H)x1520(V)) or better , Electronic Shutter : Auto/Manual, 1/3(4)~1/100000s, Scanning System : Progressive , Mini. Illumination : 0.08Lux/F2.0(Color); 0Lux (IR on), S/N Ratio : More than 50dB , Min. IR LEDs Length ≥50m, Day/Night : Auto(ICR) / Color / B/W,Back Light Compensation : BLC / HLC / WDR(120DB) ,White Balance : Auto/Natural/Street Lamp/Outdoor/Manual ,Motion Detection : Off/On (4Zone, rectangle),Focal Length : 2.8mm,Angle of View : H: 104° ,V: 57° ,Video Compression : H.265+/ H.265 ,Resolution : 4MP (2688x1520)/3MP(2304x1296)/ 2MP(1920× 1080)/720P(1280× 720),Frame Rate (3 Stream) : Main stream (4MP (1 ~ 25/30fps)) & Sub stream : D1(1 ~ 25/30fps)& Third Stream : 720P (1 ~ 25/10fps),Digital Zoom : 16x,Bit Rate : H.265: 14 ~ 9984Kbps,Network Ethernet : RJ-45 (10/100Base-T) ,Protocol : HTTP; HTTPs; TCP; ARP; RTSP; RTP; UDP; SMTP; FTP; DHCP; DNS; DDNS; PPPOE; IPv4/v6; QoS; UPnP;NTP; Bonjour; 802.1x; Multicast; ICMP; IGMP; SNMP,SD Card : Min 128GB SD card support,Power Supply : DC12V, PoE (802.3af),Working Environment : -30°C~+60°C / Less than 95%RH (no condensation),Ingress Protection : IP67 ,Audio Interface : Built-in-Mic,Intelligence (IVS) : Tripwire, Intrusion, Object Abandoned/Missing ,Advanced Intelligent Functions : Face Detection MAKE : DAHUA/PANASONIC/HONEYWELL/HYUNDAI (NS)
Supply Installation testing & commissioning of outdor 4*4 box with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE : STRONGER/MOLEX/AMP) (NS)
Supply Installation testing & commissioning of 6TB surveillance hard disk with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE : WD-PURPLE/SEGATE (NS)
Supply Installation testing & commissioning of Video Management Recorder with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Main Processor : Intel Quad-core Processor or better, Operating System :Embedded LINUX,IP Camera Input : 32 Channel or More, Two-way Talk : 1 Channel Input, 1 Channel Output/RCA, Interface : ≥2 HDMI (up to 3840 x 2160 , Different Source), ≥1 VGA, Compression : H.265/H.264, Resolution : 12MP, 8MP, 6MP, 5MP, 4MP, 3MP, 1080P, 1.3MP, 720P etc., Bandwidth : >320Mbps,Record Mode : Manual, Schedule (Regular, MD (Motion Detection), Alarm, Analytics), Holiday, Stop, Video Detection : Motion Detection/ Video Loss and Tampering/ Multiple VCA Event, Alarm input : ≥16 Channel, Relay Output : ≥8 Channel, Search Mode : Time /Date, Alarm, MD / Smart Search, Backup Mode : USB Device/Network/eSATA Device, Network Interface : 4 RJ-45 Ports (10/100/1000Mbps), Ethernet Port : 4 Ethernet Ports Joint Working or 4 Independent 1000Mbps Ethernet Ports, Network Function : HTTP, HTTPs, TCP/IP, IPv4/IPv6, UPnP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE,DDNS, FTP, Alarm Server, IP Search etc., Optical Fiber Interface : ≥2 Giga Optical Fiber Interface, User Access : ≥128 users, Smart Phone : iPhone, iPad, Android, Interoperability : ONVIF 2.4, CGI Conformant, Internal HDD : 16 SATA III Ports, Up to 8 TB capacity for each HDD, HDD Mode : Single, Raid 0/1/5/6/10, Support Global HDD Hot-spare, eSATA : 1 eSATA Port, SAS : 1 Mini SAS Port, for Storage Expansion,Front Cover : Support Hot-swap, USB : 4 USB Ports (2 USB 2.0 , 2 USB 3.0 ), RS232 : 1 Port, for PC Communication and Keyboard, RS485 : 1 Port, for PTZ Control, Power Supply,Redudant Power supply : Support, Operating Conditions : -10°C ~ +55°C, Certifications : CE,UL,FCC (NS) MAKE : DAHUA/HYUNDAI/HONEYWELL
Supply Installation testing & commissioning of AP Management License with 3 years comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : RUCKUS/CISCO/ARUBA
Supplying, Installation,Testing & Commissioning of 43 " LED/LFD Full HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source Switching & Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play (DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, HDCP Support, Smart Scheduling, Smart F/W update, Built-In MagicInfo Premium-Swith Mounting Brackets as per Technical Specification complete in all respect. (NS)
S/I/T/C of UPS 10 KVA/9KW 3 Phase in / 1 Phase out with input nominal voltage 3*400VAC ( 3P+N), with 30 minute backup on full load, voltage Range 190-520VAC ( 3 Phase ) 2 50% load and 305-478VAC ( 3 Phase ) @ 100% load , frequency Range 46-54 Hz or 56-64 Hz , P.F >/= 0.99 @ 100% Load , Output voltage 208/220/230/240VAC , Ac Voltasge regulation ( Batt. Mode ) +/- 1% , current ration 3:1 max , Harmonic distortion < 2%THD ( LINEAR LOAD ) < 5% THD ( Non-Linear Load ) , Transfer Time AC mode to Battery mode is zero , Inverter to Bypass is Zero , Waveform ( Batt. Mode ) Pure Sinewave , Efficiency AC Mode : 91.5% , ECO Mode : 97.0% , Battery Bank sizing as 42 AH x 40 nos. X 1 String. Battery type should be Valve regulated lead-acid (VRLA) of make Exide/Panasonic/QUANTA/Rocket.Battery Mode : 87% , Battery charging current (max.) 10 Amp , Charging voltage 273VDC+-1% , LCD Panel for UPS Status , Load Level , Battery Level , Input/Output voltage , Discharge timer and Fault conditions , Alarm Battery Mode sounding every 4 seconds , Low battery sounding every second , overload sounding twice every second , fault continous sounding , domension 592*250*576mm , net weight 28Kgs , operating Humidity 0-95% RH @ 0-40C ( Non0condensing) Noise level Less than 58dB@ 1 Meter , Smart RS-232/USB , support windows 2000/2003/XP/Vista/2008 Windows 7/8 Linux and MAC Code LD10K3P1P Luminous Make , EATON , Microtek (NS)
Supply, erection of 0.51 mm jelly filled armored telephone cable laid one mtr. below ground level including the cost of digging, bricks, rawl & laying charges, complete in all respect with the entire satisfaction of Engineer-in-charge. (NS) (i) 50 Pair Make:- DELTON/ FINOLEX/ HAVELLES
Supply, erection of 0.51 mm jelly filled armored telephone cable laid one mtr. below ground level including the cost of digging, bricks, rawl & laying charges, complete in all respect with the entire satisfaction of Engineer-in-charge. (NS) (ii) 20 Pair Make:- DELTON/ FINOLEX/ HAVELLES20 Pair
Supply, erection of 0.51 mm jelly filled armored telephone cable loose in existing pipe/tranches including testing & commissing charges, complete in all respect with the entire satisfaction of Engineer-in-charge. (NS) (i) 50 Pair Make:- DELTON/ FINOLEX/ HAVELLES
Supply, erection of 0.51 mm jelly filled armored telephone cable loose in existing pipe/tranches including testing & commissing charges, complete in all respect with the entire satisfaction of Engineer-in-charge. (NS) (ii) 20 Pair Make:- DELTON/ FINOLEX/ HAVELLES
Supply, erection, laying and testing of D.P. including the cost of krones, base plate, 40mm dia G.I. pipe for incoming and outgoing cable and main box having locking arrangement. (NS) (i) 50 pair DP Make:- DELTON/ FINOLEX/ HAVELLES
Supply, erection, laying and testing of D.P. including the cost of krones, base plate, 40mm dia G.I. pipe for incoming and outgoing cable and main box having locking arrangement. (NS) (ii) 20 pair DP Make:- DELTON/ FINOLEX/ HAVELLES
Sham Lal Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .