Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.5 L+₹38,137 (9.17%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹4.5 L+₹38,458 (9.24%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹4.7 L+₹56,849 (13.7%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹5.0 L+₹81,023 (19.5%)Rejected-Finance CC III 28A JANTA BHAWAN ROAD SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
12 Nov 2022, 6:00 pmClosed
GE (AF) SIRSA
GE (AF) SIRSA
REPAIRS MAINT OF GYSERS AND SOLAR WATER HEATER WITH ALLIED WORKS AT AF STN SIRSA
2022_MES_557825_1
GE/SRA/T-42 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) SIRSA
As per NIT and Tender documents
3 documents required · 3 mandatory
₹500
GE (AF) SIRSA
₹18,000
Yes
7 Dec 2022
14 Oct 2022
14 Nov 2022
14 Oct 2022
12 Nov 2022
28 Oct 2022
14 Oct 2022 - 21 Oct 2022
Amount
REPAIRS TO GEYSERS
M&L Taking down/Lowering unserviceable Geyser 25/35/50 Litre capacity of any Make and type from any height by disconnecting all Water and Electric Connections, opening of Geyser for repairing/replacing of unserviceable Accessories, removing all rusted Nuts, Bolts, checking of Inner Tank to make Fully Leakeage Proof and Testing the same with Water Filling/Air Pressure, re-fixing/re-mounting the same in Original Position and providing necessary Water/Electric Connection and Testing on Completion to the entire satisfaction of Engineer-in-Charge, complete all as specified and as directed. NOTE :- (a) Quoted Unit Rate is deemed to be included for taking down unservice-able Geyser and re-fixing of Geyser of any capacity in Original Position after repaired.(b) Accessories required for serviceability of Geyser will be Measured & Paid under appropriate Items of SCHEDULE 'A' (BOQ/PRICE SCHEDULE) here-in-after as 'S&F in replacement'.
S&F in replacement Aparatus Plate (as approved) suitable for Geyser 25 to 50 Litre capacity , complete all as specified and as directed.
S&F in replacement Geyser Element cup/triangular/threaded type glass lining, 1.5 KW, ISI Mark (as approved) , complete all as specified and as directed.
S&F in replacement Geyser Element cup/triangular/threaded type glass lining, 2.0 KW, ISI Mark (as approved) , complete all as specified and as directed. MAKE : BAJAJ/ HAVELLS/V.Guard/As approved by Engr-in-charge
S&F in replacement Gasket Rubber Ring for Heater Plate of any size Geyser (as per site) , complete all as specified and as directed.
S&F in replacement Indicating Neon Lamp Red / Green, Round/Square in shape (as approved), suitable for Geyser 25 to 50 Litre , complete all as specified and as directed.
S&F in replacement Insulation Material Glass Wool complete (as approved) and filling in Geysers 25/50 Litre capacity , complete all as specified and as directed.
S&F in replacement Inner Steel Tank, ISI marked suitable for Electric Water Heater 25 Litre capacity of any Make and type with 16 Gauge of Steel Sheet , complete all as specified and as directed.
S&F in replacement Inner Steel Tank ISI marked suitable for Electric Water Heater 50 Litre capacity of any Make and type with 16 Gauge of Steel Sheet , complete all as specified and as directed.
S&F in replacement Outer Cover ISI Marked of Inner Tank suitable for Electric Water Heater 25 Litre capacity of any Make any type made up of Mild Steel Sheet Cover 1.6mm thick , complete all as specified and as directed.
S&F in replacement Outer Cover ISI marked of Inner Tank suitable for Electric Water Heater 50 Litre capacity of any Make any type made up of Mild Steel Sheet Cover 1.6mm thick , complete all as specified and as directed.
S&F in replacement PRV (Pressure Release Valve) suitable for Geyser 25 to 50 Litre capacity , complete all as specified and as directed.
S&F in replacement Safety Fusible Plug, ISI marked suitable for Geyser 25/50 Litre capacity , complete all as specified and directed.
S&F in replacement Syphon Assembly suitable for Geyser 25 Litre capacity of any Make and type including Rubber Gaskets with Nut, Bolts & Washers , complete all as specified and as directed.
S&F in replacement Syphon Assembly suitable for Geyser 50 Litre capacity of any Make and type including Rubber Gaskets with Nut, Bolts & Washers , complete all as specified and as directed.
S&F in replacement Thermostat 11 inch and cutout Temp Range 30-90 degree centigrade manual reset type, ISI Mark , complete all as specified and as directed.
M&L Repairing leakge of Copper/Steel Inner Tank of Geyser of any capacity by Gas Welding/ Brazing for Water Tightness and Testing under Pressure, complete all as specified and as directed.
M&L preparaing Old Painted Steel Surfaces of Geyser of any Make, size or capacity by apply Putty to make the surface smooth and even and applying one coat of Synthetic Enamel Paint White, complete all as specified and as directed.
S&F in replacement PVC Connection heavy duty15mm dia in size with PTMT Nuts of length 450mm ISI marked (as approved) , complete all as specified and as directed.
S&F in replacement Metal Clad Industrial Plug Top 16/20 Amp ISI marked (as approved) , complete all as specified and as directed.
S&F in replacement Metal Clad Industrial Socket 16/20 Amp, ISI marked (as approved) , complete all as specified and as directed.
S&F in replacement Plug Top 16 Amp, ISI marked (as approved) , complete all as specified and as directed.
S&F in replacement Sheet Metal Enclosure with Metallic Socket, Plug Top and MCB Single Pole 20 Amp with 2 Pin & Earth Plug and Socket ISI marked (as approved) , complete all as specified and as directed.
S&F in replacement PVC insulated, multi-stranded Copper Conductor Cable of size 2.5 Sqmm, 3 Core , complete all as specified and as directed.
S&F in replacement PVC insulated, multi-stranded Copper Conductor Cable of size 6 Sqmm, 3 Core , complete all as specified and as directed.
S&F in replacement of stainless steel, 304 grade, 18-24 inches long with outer tube, rust resistant, double ring sealing washer, EPDM inner tube, stainless steel joints complete all as specified by Engr-in-Charge
M&L for replacement of mild steel washer, nuts and bolts suitable for 25/50 ltr geyser complete all as specified and as directed by Engr-in-Charge
M&L for descaling of electric water geyser 25/50 litre by opening apparatus plate and pvc flexible pipe and descaling with nylon wire brush first with descaling chemical till all scales are removed and then with plain water complete all as specified and as directed by Engr-in-charge
REPAIRS TO SOLAR WATER HEATERS
M&L Taking down Dismantling Solar Water Heater Tank 500 LITRE PER DAY capacity by taking the Outer Cladding, Glass Wool and repairing Old Serviceable Inner Tank made out of Stainless Steel Sheet, re-fixing the same in Original Position with and including new Mild Steel Nut, Bolts and and Testing upto satisfactory performance, complete all as specified and as directed.
M&L Taking down Solar Water Heating System Collector Panel from its Position, removing the Top Glass of Solar Heat Collector and carry out welding/ brazing work to the Collector and arresting the leakages in the Collector, refixing Top Glass Back, Testing for proper satisfactory Function, complete all as specified and as directed.
M&L Serviceing Solar FP Collector by removing the Flange Plates, cleaning the Collectors internally by using Descalo Solution, removing the blockages in the Collectors and re-fixing the Flange Plates, Testing for proper satisfactory Function, complete all as specified and as directed.
M&L Cleaning, washing Solar Glass Panel of Solar Water Heating System and Painting to Mild Steel Stand of Solar Water Heating System and Mild Steel Staging of Cold and Hot Water Tank with Synethic Enamelled Paint (White Colour), complete all as specified and as directed.
M&L Solar Water Heater Tank 500 LITRE capacity, made out from Stainless Steel Sheet 16 Gauge, fixing with and including new Nut, Bolts as per existing, hoisted/fixing in Position, providing necessary Water & Electric Supply Connections, Testing (upto satisfactory performance) on Completion including lowering/taking down Solar Water Heater Tank of any description, complete all as specified and as directed.
M&L Taking down unserviceable Solar Flat Plate Collector by disconecting Flange Plates and Rubber Hose Pipes and replacing with new Flat Plate Collector of same size and Model, connecting Flange Plates and Rubber Hose, Testing for proper satisfactory Function, complete all as specified and as directed.
S&F in replacement Flexible Heat Resistance Rubber Pipe (from Inter Connect Plate Collector to Hot Water Tank) of size 25mm to 32mm dia with fixing Clamp, etc. , complete all as specified and as directed.
S&F in replacement Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore helical/cone/cup type complete all as specified and as directed.
S&F in replacement Heating Element for Solar Water Heating Plant of capacity 3.0 KW, ISI Marked , complete all as specified and as directed.
S&F in replacement Thermostat for Solar Water Heating Plant suitable for 3.0 KW to 5.0 KW , complete all as specified and as directed.
BHATIA ENTERPRISES
YOGINDER KUMAR GUPTA AND COMPANY
AMBIKA ENTERPRISES
M/s Satguru Traders
Singla Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .