Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC | ₹28.4 L Quoted ₹29.0 L | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹29.8 L+₹83,080 (2.86%)Rejected-Finance | ₹29.8 L+₹83,080 (2.86%) | L2 | Rejected-Finance Being other than Lowest Tenderer |
| 3 | L3₹30.9 L+₹1.9 L (6.61%)Rejected-Finance | ₹30.9 L+₹1.9 L (6.61%) | L3 | Rejected-Finance Being other than Lowest Tenderer |
| 4 | L4₹31.7 L+₹2.7 L (9.27%)Rejected-Finance | ₹31.7 L+₹2.7 L (9.27%) | L4 | Rejected-Finance Being other than Lowest Tenderer |
| 5 | L5₹32.3 L+₹3.3 L (11.5%)Rejected-Finance SHOP NO 02 GROUND FLOOR SAMUDRIKA CHS PLOT NO 183 URAN RAIGAD MAHARASHTRA 400 702 | RAIGAD | MAHARASHTRA | 400702 | ₹32.3 L+₹3.3 L (11.5%) | L5 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
10 Apr 2024, 6:55 pmClosed
MAJOR ANIL KUMAR S GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8979 REPAIR REWINDING OF CEILING FAN EXHAUST FANS AND CERTAIN EM WORKS ETC AT INS TRATA GODFREY CLINIC NOORBHOY BLDG INS ANGRE AND CONNECTED AREA UNDER GE NW KUNJALI
2024_MES_648090_1
8979/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹98,000
Yes
15 May 2025
28 Mar 2024
12 Apr 2024
1 Apr 2024
10 Apr 2024
3 Apr 2024
28 Mar 2024 - 1 Apr 2024
Amount
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, removing material to store for keeping in safe custody and making good to disturbed surfaces complete all as specified and as directed.
S & F in repair of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A all as specified and directed .
S&F in repair of double door type SPN DB 12 Way ,240V with 100A copper busbar each phase , with metalic double door type IP-43 IK 09 protection suitable for housing MCB's all as specified and directed by EIC. Make: Legrand cat No 507612 or equivalent make in list of manufactures. Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type SPN DB 08 Way ,240V with 100A copper busbar each phase , with metalic double door type IP-43 IK 09 protection suitable for housing MCB's all as specified and directed by EIC. Make: Legrand cat No 507611 or equivalent make in list of manufactures. Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type SPN DB 04 Way ,240V with 100A copper busbar each phase , with metalic double door type IP-43 IK 09 protection suitable for housing MCB's all as specified and directed by EIC. Make: Legrand cat No 507611 equivalent make in list of manufactures. Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type vertical type TPN DB 6 Way ,240V with 200A busbar , with metalic double door type IP 43 IK 09 protection suitable for housing MCCB's all as specified and directed by EIC.Make: Legrand cat No 507782 or equivalent make in list of manufactures. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type vertical type TPN DB 8 Way ,240V with 200A busbar , with metalic double door type IP 43 IK 09 protection suitable for housing MCCB's all as specified and directed by EIC.Make: Legrand cat No 507782 or equivalent make in list of manufactures. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type vertical type TPN DB 12 Way ,240V with 200A busbar , with metalic double door type IP 43 IK 09 protection suitable for housing MCCB's all as specified and directed by EIC.Make: Legrand cat No 507783 equivalent make in list of manufactures. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S & F MCCB FP 125 Amps,16KA, complete all as specified and directed. Make : Legrand cat No 420016 equivalent make in list of manufactures.
S & F MCB SP 6-32 Amps,10KA, 'C' series 240V complete all as specified and directed.
S & F MCB SPN 63 Amps,10KA 'C' series 240V complete all as specified and directed.
S & F MCB TP 40 Amps,10KA complete all as specified and directed.
S&F MCCB 415 volts, 3 pole of cap 200 Amps, 25 KA ICS= 100% ICU with fixed thermal magnetic setting including spreader terminal of suitable size and making connections complete all as specified & directed. Make : Legrand Cat No 420208 or equivalent make in list of manufactures.
S&F MCCB 415 volts, 250Amp 4 pole 36 KA ICS= 100% ICU with fixed thermal magnetic setting including spreader terminal of suitable size and making connections complete all as specified & directed. Make : Legrand Cat No 420239 or equivalent make in list of manufactures.
S&F MCCB 415 volts, 400Amp 4 pole 36 KA ICS= 100% ICU with fixed thermal magnetic setting including spreader terminal of suitable size and making connections complete all as specified & directed. Make : Legrand Cat No 422002 or equivalent make in list of manufactures.
S&F MCCB 415 volts, 63Amp 4 pole 16 KA ICS= 100% ICU with fixed thermal magnetic setting including spreader terminal of suitable size and making connections complete all as specified & directed. Make : Legrand Cat No 420003 or equivalent make in list of manufactures.
taking down and M&L for sub-main wiring with 2 runs of 2.5 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing and caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 2.5 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 2 runs of 2.5 Sqmm copper conductor and one run of PVC casing caping shall be measured as one unit.
Taking down & M&L for sub-main wiring with 2 runs of 4.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 2 runs of 4 Sqmm copper conductor and one run of PVC casing caping shall be measured as one unit.
Taking down and M&L for sub-main wiring with 2 runs of 6.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC capping casing not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 6.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 2 runs of 6 Sqmm copper conductor and one run of PVC casing caping shall be measured as one unit.
Taking down and M&L for sub-main wiring with 4 runs of 10.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade Caping casing not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 10.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/Gloster/Plaza (c) Make of PVC casing capping :- Precision/ pesto plast / National/Plaza
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100volts, drawn through and including non metalic rigid PVC casing and caping not less than 25mm with all accessories fixed on wall//ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of PVC Modular box with cover plate fixed on wall for fixing the switches, switch sockets,sockets, regulators etc complete all as specified for:- NOTE: a) Colour coding shall be followed as given below:- i) Phase - Red/Yellow/Blue ii) Neutral - Black iii) Earth - Green b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit. (c) Make of wire :- Havells/ Finolex/ Plaza/Gloster/Polycab. (d) Make of PVC casing capping :- Precision/ pesto plast / National/Plaza (i) One light point controlled by one 5A switch
One Fan point controlled by one 5A switch complete all as specified & directed.
One 5A flush type switch socket point on same board complete all as specified & directed.
One 5A flush type switch socket point on independent board complete all as specified & directed.
M&L for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module complete necessary electric connection for each workstation point comprising of 02 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately.
M&L for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 2.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module complete for One 5 pin, 15A switch socket combination on the independent board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately.
S & F ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified and directed .
S & F modular switch 1 way 6A,1 module all as specified and directed .
S & F modular switch 1 way 16A,1 module all as specified and directed .
S & F modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed.
S & F modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed .
S&F for modular fan step regulator, 100W - 2 modular all as specified and directed .
M&L point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly including pvc moulded box/hylem sheet ISI marked fixed on wall for fixing the switches, switch, socket all as specified.Notes: NOTE: a) Colour coding shall be followed as given below:- i) Phase - Red/Yellow/Blue ii) Neutral - Black iii) Earth - Green b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit. (c) Make of wire :- Havells/ Finolex/ Plaza/Gloster/Polycab. (d) Make of PVC casing capping :- Precision/ pesto plast / National/Plaza (a) One light point controlled by one 5A switch
All as per item No. 33 above but for One Bell point control by one 5A bell push switch complete all as specified & directed.
All as per item No. 33 above but for One Fan/ExhaustFan point controlled by one 5A switch complete all as specified & directed.
All as per item No. 33 above but for One 5A switch socket combination on the same board complete all as specified & directed.
All as per item No. 33 above but for One 5A switch socket point on independent board complete all as specified & directed.
M&L for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etc fixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including PVC moulded box/ hylem sheet ISI marked fixed on wall complete comprising of 02 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red/yellow/Blue (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately
M&L point wiring complete with 2.5Sq. mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC moulded box/ hylem sheet ISI marked fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 2.5Sq. mm as earth continuity conductor connected to common earth dolly for 15 amp swich socket on independant board complete all as specified. Note: (a) Colour coding shall be folowed as (i) Phase- Red/yellow/Blue (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately
S & F switch piano flush type single pole one way ,5/6 Amps complete all as specified & directed.
S & F Bell push, 5/6 Amps, 240 volts SP complete all as specified & directed.
Supply and fix switch sockets combination 5 pin 5 Amps flush type 240 Volts AC complete all as specified & directed.
Supply and fix switch socket combination multi purpose 3 pin 15 Amps controlled by one switch flush type 240 Volts AC complete all as specified & directed.
S & F fan regulator electronic step type socket size and making all necessary connections complete all as specified & directed.
S & F bell, DINGDONG, 240 volts, SP complete all as specified & directed.
S & F Ceiling rose, PVC/polycarbonate insulated body type, 3 teRunning Metreinal, 240 volts, 5 Amps complete all as specified & directed.
S & F lamp holder PVC/polycarbonate insulated body type complete all as specified & directed.
S & F in replacement of LED driver suitable for 36/40W recess mounting fitting complete all as directed.
Disconnecting & taking down, strip opening, cleaning all parts and packing of Exhust fan of any make and size & greasing ball bearing with specified quilty grease and painting complete all as specified & directed.
M&L for hanging Exhust fan in position & re-comissioning the same including making new electric flexible wire connection complete all as specified & directed.
Disconnecting & taking down, strip opening, cleaning all parts and packing of ceiling fan of any make and size & greasing ball bearing with specified quilty grease and painting complete all as specified & directed.
M&L for hanging ceiling fan in position & re-comissioning the same including making electric connection complete all as specified & directed.
Supply and fixing in repair walll/surface mounted 10W LED batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed. Make : C&S cat No LTTB2F10WLEDW BATTEN or equivalent make in list of manufactures
Supply and fix shade light of desire make and shape with LED light and shaded glass for proper luminaries and lighting all as specified and directed
Disconnecting and takig out old gyeser and Supply and fix gyeser of capacity 15 ltrs suitable for high pressure upto 8 bar 2 kw wattage at the existing position with hot and cold pvc flexible pipe complete all as specified & directed.
Supply and fix LED COB Downlight of 12 W capacity lumen efficiency is 100 Lm/W in CDL varient special design for heat sink complete all as specified & directed.
Supply and fixing in repair walll/surface mounted 20W LED batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : C&S cat No LTTB4F20WLEDEW BATTEN or equivalent make in list of manufactures
Supply and fixing in repair new generation recessed mounted ultra slim panel LED 2X2 Luminaire 36 watt and CRCA powder coated body and high translucent diffuser provides high quality ecomonic energy saving lighting to modern offices. Suitable for 600 x 600 mm modular/POP/Gypsum ceiling. Make : C&S Cat No: LTCRSLM36WATT2x2 or equivalent make in list of manufactures
Supply and fixing in repair new generation recessed mounting Aluminium housing downlight ultra slim round Luminaire 15/18 watt and high translucent diffuser provides high quality ecomonic energy saving lighting all as specified and directed by EIC. Suitable for modular/POP/Gypsum ceiling. Make : C&S Cat No: LTCRSLM15HPLEDRND or equivalent make in list of manufactures
Removing the existing window Air conditioner 1.5/2TR complete including all accessories and closing opening of wall with brick workin cement mortor 1:4, plastering , white washing / destempering to match with surroundings and Shifting of window type Air conditioner including accessories, making suitable size opening in existing wall suitable fixing air conditioner, fixing of wooden frane made out of not lessthan 50x75mm hard wood runners painting, fininshing in cement mortor in 1:4 white wasing / distempering to match with surroundings. at suitable location all as specified & directed by EIC.
M&L for shifting of Split AC unit from existing postion & refixing the new position/location in cluding additional accerssories as required, testing & commisssioning complete all as specified and directed .
Supply and fixing copper tubings of appropriate dia offor suction line & for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing thugh pipe and making good distrubed surface completely complete all as specified and directed .
S&F in repairs of 0.71mm thick aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter including suitable size of revits/nut bolts complete bending, shaping, drilling, cutting notching and all as specified and directed.
Material and Labour for Earthing complete with MS plate electrode of size 600 X 600 X 6 mm buried directly and preferably vertically in ground (earth pit not less than 2.25 mtrs deep below ground level ) with top edge of the plate not less than 1.5 Mtrs below ground level, connected to earth strip 25x4 mm galvanized MS strip by means of check nuts, bolts, washers etc all as shown in electrical plate No. 5 of SSR Part-I, connected to Earthing test point including earth work, 1:3:6 C1 PCC chamber, 1:2:4 B1 PCC cover with 8 mm dia steel bars at 100 mm C/C suitable size of GI pipe for earth lead protection and watering, water funnel etc. complete all as specified and directed.
M&L for 25x4mm GI earth continuity conductor or main earthing lead fixed to wall or buried in ground or drawn in conduit/ pipe or fixed to transformer/panel body complete all as specified and directed .
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed .
Taking down defective cable and Supply and Laying 4 core 16 Sqmm testing and commissioning PVC insulated PVC sheathed armoured electric cable with aluminium conductor laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the following sizes complete all as specified and directed ..
Taking down defective cable Supply and Laying 4 core 10 Sqmm testing and commissioning PVC insulated PVC sheathed armoured electric cable with aluminium conductor laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the following sizes complete all as specified and directed .
shubham construction
Laxmi Sales
NOEL ENGINEERS
BRICKS ON CLOUD INFRA
Genius Construction Co.
SHRI SAI ENTERPRISES
Rama Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .