Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹34.7 L+₹2.1 L (6.52%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹36.3 L+₹3.7 L (11.5%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹37.5 L+₹5.0 L (15.3%)Rejected-Finance BARIYAWAN BARIYAWAN BARIYAWAN BARIYAWAN AMBEDKAR NAGAR UTTAR PRADESH 224210 | AMBEDKAR NAGAR | UTTAR PRADESH | 224210 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹39.2 L+₹6.7 L (20.5%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
30 Jan 2024, 6:00 pmClosed
GE (CENTRAL) DELHI CANTT-10
GE (CENTRAL) DELHI CANTT-10
REPAIR/ REPLACEMENT OF INTERLOCKING PAVER BLOCK, CHEQUERED TILES, PARKING SHED AND FENCING INCLUDING REPAIR/ REPLACEMENT OF INTERNAL WIRING, DB, MCB AND MISC E/M WORKS AT 1 WEC, EETSU, WEE WKSP, P-12, P-26 AND P-35 AT SANJAY VIHAR AND ADJOINING AREA
2024_MES_635440_1
GE/C-75/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹1 L
Yes
15 Feb 2024
2 Jan 2024
1 Feb 2024
2 Jan 2024
30 Jan 2024
16 Jan 2024
2 Jan 2024 - 16 Jan 2024
Amount
Demolition of brick work or stone masonry built in cement mortar in any position including segregating serviceable/unserviceable bricks/stones Complete all as specified and directed by Engineer-in-Charge.
M & L for brick work with Cement Mortar1:6 using sub class 'B' bricks,old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed.
Aee as per S.No. 2 here in before but except bricks
M&L for rendering 15 mm thick in CM 1:4 on any faces of concrete or brick surfaces finished even and smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over primer complete all as specifed as direted by Engr-in-charge.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc Complete all as specified and directed by Engineer-in-Charge.
M & L for cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in mass concrete Complete all as specified and directed by Engineer-in-Charge.
M&L for providing 40 mm thick cement concrete 1:2:4 type B1 (20 mm graded aggregate) as in hard standing laid in alternate bays Complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete interlocking paver block 60mm thick M-35 grade any shape and size with grey cement and pigment Complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling under floor or in foundations including watering and consolidation Complete all as specified and directed by Engineer-in-Charge.
M&L 15 mm thick screed bed or bedding layer for laying floor finishes of tiles CM 1:6 Complete all as specified and directed by Engineer-in-Charge.
S&F Chequered cement concrete PU coated colourtiles 300cm X 300cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigments Complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete type C-1 1:3:6 (20mm graded aggregate) as in copings Complete all as specified and directed by Engineer-in-Charge.
Dismantling/ demolition posts or struts embedded in soil or concrete etc (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground Complete all as specified and directed by Engineer-in-Charge.
Dismantling fencing wiremesh, any type Complete all as specified and directed by Engineer-in-Charge.
Excavation in post holes (or similar holes) n exc 0.5 cum getting out in any type of soil returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm and covering and removal of surplus soil n exc 50m and making good surface Complete all as specified and directed by Engineer-in-Charge.
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wiremesh etc) including all necessary drilling, bolting or riveting, etc including embeding in concrete and similar work conforming to Fe-290 Gde-E-165 Complete all as specified and directed by Engineer-in-Charge.
S&F high quality zinc coated GI Chain link fencing of required width in mesh size 50x50 mm made of GI wire dia not less than 3mm and fix with column with nut or bolts and strengtheing with 10mm TMT bars, conforing to standard grade steel complete all as specified and directed. NOTE:- (i) Payment of TMT bar shall be made in seperate items in this Schedule. (ii) The Engr-in-Charge along with rep of contractor shall verify the weight mesh and submit the copy along with photographic eveidence along with RAR and Purchase Voucher. (iii) The quoted rate shall be inclusive of Nut bolt required.
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Complete all as specified and directed by Engineer-in-Charge.
S&F 12mm mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut n exc 5cm long Complete all as specified and directed by Engineer-in-Charge.
S&F in repair galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straning and fixing to fencing post with staple or steel pins etc Complete all as specified and directed by Engineer-in-Charge.
Dismantling of wrought iron or mild steel work of any description Complete all as specified and directed by Engineer-in-Charge.
S & F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and framework for tank stagging and simillar items also fastening and fixing complete all as specified and directed by enginer-in -charge.
M&L for preparation of new or previously untreated steel surfaces over 10cm in width or girth and applying two coats of syanthetic anamel paint over one coat of red oxide Complete all as specified and directed by Engineer-in-Charge.
Dismentling plain or corrugated steel sheeting any gauge thickness including nainital or similar pattern roof covering Complete all as specified and directed by Engineer-in-Charge.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
Taking down care fully copper/aluminium point wiring from wooden batten (except) conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
Taking down old MCCB , TPN DBs , SPN DBs, & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed.
Taking down old submain wiring of any size, including coduit and make from the site complete all as specified.
Taking down old unsv light fitting of any size and make from the site and making good surface complete all as specified.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed / surface PVC conduits as suitable of site (Medium grade) of size not less than 20 mm dia incl proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, 3 mm thick hylem sheet cover for terminal boxes painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories for PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
All as per item No 32 above but one light/fan point controlled by one switch.
All as per item No 32 above but One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board.
All as per item No 32 above but One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
All as per item No 32 above but One bell point controlled by one bell push.
All as per item No 32 above but One light point controlled by two Nos two way switches
All as per item No. 32 above but point wiring with two single core 4.0 sqmm size cables and one 4.0 sqmm green colour cable as earth continuity conductor for one 6 pin 15 Amps socket out let on independent board.
M&L switch piano flush type 5 Amp SP one way ISI marked complete all as specified.
M&L switch piano flush type 5 Amp SP two way.
M&L switch piano flush type 15 Amp SP one way ISI marked complete all as specified.
M&L bell push,flush type,5 amp ISI marked complete all as specified.
M&L socket outlet 5 pin 5 Amp flush type ISI marked complete all as specified.
M&L socket outlet 2 in 1,3 pin 5/15 Amps ISI marked complete all as specified.
M&L ceiling rose 3 phase PVC polycorbonate,isolated body. complete all as specified.
S & F electronic fan regulator 5 step ISI marked connecting complete all as specified.
M&L bell electric (ding dong) 230 volt, SP all as specified and directed.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 4 Sqmm in and including new PVC conduit medium grade not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 2.5 Sqmm size stranded conductor as earthwire.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including new PVC conduit medium grade not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 4 Sqmm size stranded conductor as earthwire.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 900 lm system lumen output with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete.
Supply and fix 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete.
Supply and fix 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete.
S & F in replacement of decorative type wall mounted luminaire (comet) with under take poly carbonate material suitable for 1 x 14 watts LED bulb B-22 base complete all as specified and as directed.
Refixing of Ceiling fan / exhaust fan/ fresh air including taking down after necessary repairs/ replacement of unserviceable/ wornout part and testing the same as per entire satisfaction of Engr-in- Charge complete all as specified and directed. Note- Spare Parts shall be measured and paid separately under relevant item of supply only.
M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Teating of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
S&F in replacement capacitor of 2.5 MFD.
S&F in replacement gun metal bush of any size and make sutiable for ceiling fans 1200 mm compete all as specified and directed.
S&F in replacement ball bearing No. 6202./6203
S&F in replacement worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as directed.
S&F Ceiling fan blade suitable for 1200mm sweep of any make with suitable size as per site requirement complete all as specified and directed.
M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as directed.
S&F in replacement exhaust fan motor capacity 1/4 HP 230 volts suitable for 300 mm size exhaust fan complete all as directed.
Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as directed. Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only.
S&F in replacement only base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site as directed.
S&F in replacement of thermostat for 25/35/50 ltrs capacity of geysers complete all as directed.
S&F in replacement heating element of 2/1.5 KW triangular type with nut bolt washer complete all as directed.
M&L for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
M & L chromium plated copper connection pipe 60 Cm long with two brass adopters and connecting up complete all as directed.
Supply only inner still tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as directed.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
M&L MCB SPN 40 Amp "C " curve all as directed.
M&L MCB SP 6 to 32 Amp "C" curve all as directed.
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 10 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete.
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified.
Material & labour, jointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 35 Sqmm 4 core complete all as specified and directed.
Taking down LT XLPE cable any type and size all as specified and as directed.
Taking down crefully existing electric meter and refixing the same location location all as specified and as directed .
Schedule of Credit
GIAN ENGINEERS
M/S ANIL KUMAR
m/s VK construction company
a.k constructions
VED PRAKASH ARORA
POONAM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .