Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹21.6 L+₹10,196.80 (0.47%)Rejected-Finance | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹22.0 L+₹44,216.10 (2.05%)Rejected-Finance NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹22.0 L+₹44,860.70 (2.08%)Rejected-Finance | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | L5₹22.0 L+₹51,447.90 (2.39%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
REPAIRS / REPLACEMENT / MAINT OF 11 KV HT OVERHEAD AND UNDERGROUND ELECTRIC SUPPLY NETWORK AND CONNECTED WORKS AT KALIMPONG UNDER GE 867 EWS
2023_MES_605290_1
CWE/136-WE/13 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kalimpong
Class E, Category b(ii)
9 documents required · 9 mandatory
₹500
GE 867 EWS
₹40,000
22 Jul 2023
23 Jun 2023
17 Jul 2023
23 Jun 2023
15 Jul 2023
8 Jul 2023
23 Jun 2023 - 30 Jun 2023
Amount
Excavation in trenches/ foundation in soft / loose soil not exc 1.5 m wide and n exc 1.5 m in depth for for laying of under ground cable/ stay assembly /pole foundation or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and exc 1.5m depth and n exc. 3.0m depth for for laying of under ground cable/ stay assembly /pole foundation or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
Returning filling in soft / loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
Supplying, install and errect in true vertical position steel tubular swaged welded pole complete with cast iron/MS base plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW M.S. tubing conforming to IS-2713 part-II type 410 SP-55 (11.0 metre long) HT including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, complete all as specified and directed.
M&L for plain cement concrete (1:3:6), type C2 (using 40 mm graded stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for plain cement concrete (1:3:6), type C-1 (using 20 mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts, coping, filling in pressed steel chowkat or similar work including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Supply and laying. jointing, testing and commissioning HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm, 3 core, complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm, complete all as specified and directed.
Material and labour for sand for cushioning to underground cable screened un-washed river sand and punning for cushioning to cable, complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m or removing from site of work, complete all as specified and directed.
Material and labour for cross arms, bracings, supports clamps, stay clamps etc fabricated from structural steel sections including nuts, bolts, washers welding bending cold or hot drilling holes for bolts any size of shape and including hooks and clamps for aerial bunch cable as indicated and directed and inclusive of two coats of aluminium painting over a coat of red oxide primer, complete all as specified and directed.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed.
M&L for scrubbing out old paint, rust etc and making smooth and even surface then painting of four pole structure by one coat of aluminium paint including steel structure 11 meter long steel tubular pole and mild steel work i.e. cross arms, bracing, clamps, with painting yellow and black strip 30 cm wide up to 1.5 m height from the copping level etc., complete all as specified and directed. Note: Contractor or his authorised representative should take necessary shutdown before painting work and should be present at sited during the work.
M&L for scrubbing out old paint, rust etc and making smooth and even surface then painting of two pole structure by one coat of aluminium paint including steel structure 11 meter long steel tubular pole and mild steel work i.e. cross arms, bracing, clamps, with painting yellow and black strip 30 cm wide up to 1.5 m height from the copping level etc., complete all as specified and directed. Note: Contractor or his authorised representative should take necessary shutdown before painting work and should be present at sited during the work.
M&L for scrubbing out old paint, rust etc and making smooth and even surface then painting of 11 meter long steel tubular pole with cross arms, painting yellow and black strip 30 cm wide up to 1.5 Mtrs height from the copping level etc. by one coat of aluminium paint, complete all as specified and directed. Note: Contractor or his authorised representative should take necessary shutdown before painting work and should be present at sited during the work.
M&L for General Servicing & Testing and calibration of 11 KV Indoor Vacuum Circuit Breaker (Cleaning, oiling, greasing, IR Value check, Electrical and mechanical operation check & adjustment, primary injection of CTs to check the TMS of relay and time coordination) including checking auxiliary supply and control voltage, physical checking of breakers, epoxy housing, carryout physical verification of any wear and tear in breaker and rectified it, checking fixed and moving contracts, spring charging motor, control circuit & tighten the connections and close or trip coil, clean the breaker compartment through lubricate the breaker, apply grease/ petroleum jelly on required part, complete all as specified and directed.
Material and labour for fault finding and repair/ replacement of defective control wiring of tripping circuit, closing circuit, potential transformers, ampere meter, voltmeter,current transformers, thermostate & heating element circuits of indoor type 11 KV VCB using with 2.5 sqmm copper flexible PVC insulated wire and suitable size of copper lugs and thimbles and connector, complete all as specified and directed.
Supply, installation, testing and commissioning of CT 11 KV epoxy type ratio 200-100/5 Amps, accuracy Class-I single pole (Three core type) fixing on existing 11 KV panel including necessary connections, any modification required, addition/alteration required for fixing CT in existing 11 KV panel, complete all as specified and directed.
Supply, installation, testing and commissioning of CT 11 KV epoxy type ratio 50-25/5 Amps, accuracy Class-I single pole (Three core type) fixing on existing 11 KV panel including necessary connections, any modification required, addition/alteration required for fixing CT in existing 11 KV panel, complete all as specified and directed.
Material and labour for replacement of indoor type potential transformer of 11KV 3 Phase, input voltage 11 KV, out put voltage -110 volts, complete as per existing specification / make and as directed.
M&L for closing coils suitalbe for 11 KV VCB of indoor type, complete as per existing specification / make and as directed.
M&L for triping coil suitalbe for 11 KV VCB of indoor type, complete as per existing specification / make and as directed.
Supply and fix of limit switch suitable for 11 KV VCB, complete as per existing specification / make and as directed.
M&L for Rarchet gear assembly sutable for spring charging mechanism of 11 KV VCB, complete as per existing specification / make and as directed.
Suplly, fix, testing and commissioning of step down rectifier panel AC 230 volt in to DC 110 V output for controlling external input voltage for relays in 11 KV VCB, complete all as specified and directed.
Material and labour for painting of 11 KV VCB with super enameled paint after scapping the existing paint, complete all as specified and directed. Note: Contractor or his authorised representative should take necessary shutdown before painting work and should be present at sited during the work.
Cleaning of area of Sub stn, 11 KV yards, rransformer yard, four / two poles structures including cutting of shrubs, bushes etc., all as directed at site whenever required at site.
M&L for painting of chain link fencing and cover fencing of transformer (where required) any mesh, size and type by means of two coat of aluminium paint including line wires, MS flat angle and barbed wire by means of two coat of bituminous paint of sub stn, complete all as specified and directed. Note: Contractor or his authorised representative should take necessary shutdown before painting work and should be present at sited during the work.
M&L for air break, gang operated with 09 Nos insulators outdoor type, triple pole mechanically operated, suitable for vertcal installation intalltion , single break, provided with locking arrangement consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe heavy grade for operating from 1.2 m above GL confirming to IS -1318 of1972 rated voltage 11 KV & for current rating 400 Amp, complete all as specified and directed.
M&L in replacement for drop-out fuse unit, expulsion type for out door air break gang operated switch, single pole mounted on and including insulators and jumpers for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washers etc., systhetic bounded fuse tube with line cap suitable for current carrying capacity above 50 Amp upto 100 Amp, complete all as specified and directed.
Material and labour for repairing of damaged / unserviceable gang operate devices of 11 KV such as male & female contacts, flexible jumpers, MS jumper carrier and back connector plate incl cleaning and greasing of complete contacts of GOD unit, DO fuse unit and reluging of aluminium conductors connected to top & bottom contacts of GOD and DO units including welding and threading of operating rod mechanism making serviceable, complete all as specified and directed. Note: Rates for Welding machine, threading arrangements, grease, jumper, nut bolts tightening and binding wire, aluminium conductor wire deemed to be included in quoted rates.
M&L for repairs to leaking transformers at site up to 400 KVA by opening the top cover, draning the transformer oil to the level just below the bushing, replacing the all four bushing with connecting rod, replacing the oil gaskets of bushings on HT & LT side, replacing the top oil gasket, reassebling, testing etc., complete all as specified and directed.
M&L for transportation, loading and unloading of transformer capacity 25 to 400 KVA from MES power house to any other location in Kalimpong mil station not more than 5 KM distance and returning back unserviceable transformer to MES power house, complete all as specified and directed.
M&L for disconnecting the electric connection from over head line with care and removing the faulty step down transformer from two / four pole structure/platform and opening for inspection of Engr-in-Charge, fault finding and minor repairing/ servicing of transformer and repair/ replacement of worn out spares as directed at site and cleaning the transformer body thoroughly with cotton and sand paper and reassembling, refilling of transformer oil, installation the same on its existing position connecting and testing complete 11/0.433 KV transformer of 25 to400 KVA capacity, complete all as specified and directed. Nots: 1. The material required for replacement of faulty parts will be measured and paid separately under relevant item(s). 2. The cost for fault checking/ fault finding, servicing and minor repairing including minor parts is deemed to be included in quoted rate. 3. New transformer oil topping up after repair will be measured and paid separately against relevant item(s). 4. New items such as HT/LT bush insulators, HT/LT bush rod of brass, rubber gasket will be measured under respective item(s).
Material and labour for loading of the transformer capacity 25 to 400 KVA and transportation upto Factory (Siliguri) for repairing, after repair return back to existing lcation, complete all as specified and directed. Note: Transportaion charges deemed to be included in quoted rate.
Material and labour for dismantling of the transformer after opening the external metal cover and lifting the core and winding assembly complete survey and preparation of survey report, all as specified and directed.
Material and labour of new copper wire for HV (11 KV) coils, complete all as specified and directed.
M&L for rewinding charges of the above HV (11 KV) copper coils including coil forma charges, complete all as specified and directed.
M&L for re-insulation charges of the existing LV (433) volt copper strip wire with supply of high quality insulation paper after through cleaning of existing insulation and washing it through CTC, complete all as specified and directed.
M&L for rewinding charges of the above LV (433 volts) copper coils including coil forma charges, complete all as specified and directed.
Supply of insulating material like; Glass tube, Bakelite Tube, glass tape, pre-compress board, crape paper, press phan paper cotton tape, varnish etc., complete all as specified and directed.
M&L for re-assembling of both HV & LV coils after core binding and reconnection of coils and drying the assembly through heating and testing, complete all as specified and directed.
M&L for box up the above transformer after cleaning of tank and refitting of Bushing and testing, complete all as specified and directed.
Supply only of new transformer oil for topping up, all as specified and directed. Make: Power Oil / Castrol / HP / Savita Oil
Checking of old transformer oil and filtration (di electric stregth) after centrifuging of oil with filtration machine. The machine continuously will run round the clock till obtaining the result of oil upto 50 KV die electric strength in 2.5 mm gap, complete all as specified and directed. Notes: (a) The filtration of transformer oil of various transformers is to be carried out at different sub stations of Kalimpong mil area and Contractor should check the feasibility how to filter the oil of transformer before coating rate and if any additional pipe or material is required to reach the transformer, cost for the same is deemed to be included. (b) The report before filtration and after filtration to be submitted by contractor in the approved format. (c) Oil for topping up will be measured and paid seperately under respective item(s).
Supply only for replacement of HT 11 KV bush insulator suitable for distribution transformer of upto 200 KVA, complete all as specified and directed.
Supply only for replacement of HT 11 KV bush insulator suitable for distribution transformer 250 KVA to 400 KVA, complete all as specified and directed.
Supply only for HT bush rod made out of brass with nut bolt and washer suitable for distribution transformer any type of upto 200 KVA, complete all as specified and directed.
Supply only for HT bush rod made out of brass with nut bolt and washer suitable for distribution transformer any type of 250 KVA to 400 KVA, complete all as specified and directed.
Supply only for LT bush rod made out of brass with nut bolt, rubber packing and washer suitable for distribution transformer Up to 200 KVA, complete all as specified and directed.
Supply only for LT bush rod made out of brass with nut bolt, rubber packing and washer suitable for distribution transformer 250 KVA to 400 KVA, complete all as specified and directed.
Supply only for replacement of rubber/ cork sheet gasket set complete suitable for transformer of any type of Up to 200 KVA, complete all as specified and directed.
Supply only for replacement of rubber/ cork sheet gasket set complete suitable for transformer of any type of 250 KVA to 400 KVA, complete all as specified and directed.
M & L for breather container of suitable for 11 KV, 250 KVA to 400 KVA distribution transformer capacity, complete all as specified and directed.
M & L for breather container of suitable for 11 KV, 50 KVA to 200 KVA distribution transformer capacity, complete all as specified and directed.
M&L for replacement of old silica gel for breather with new one of suitable capacity for trasformer 63 KVA to 400 KVA, complete all as specified and directed.
M&L for replacement of HT 11 KV off load tap changer with new one with necessary fittings of suitable capacity for trasformer 63 KVA to 200 KVA, complete all as specified and directed.
M&L for cleaning of old painting surfaces by cleaning agents including removing dirt, dust, oil, grease etc of transformer capacity 75 KVA to 400 KVA at different sub station and providing two coats of synthetic enameled spray paint including writing SM/ MES /Machine Numbers and date of painting, complete all as specified and directed.
Material and labour in replacement of HT insulationg mat as per IS: 15562 - 2006 comprising of Class C, 20mm thick, di-electric strenght -65 KV, dimension (1mtrs X 2 mtr) blue in colour, complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 m below the ground level with top edge of earth plate not less than 1.65 m below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 m and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC (1:3:6), type C1 (using 20 mm graded crushed stone aggregate) in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion, complete all as specified and directed.
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
SANJAY KAUSHIK
Janata Enterprises
KAMLESH ENTERPRISE
S K ENTERPRISES
SANJAY SAW MILL
MS MAYA PRAKASH GOEL AND SONS
MS ORIENT ENGINEERING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .