| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.1 L+₹63,380 (2.15%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹30.7 L+₹1.2 L (4.10%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹32.2 L+₹2.8 L (9.47%)Rejected-Finance 96 SHASTRI NAGAR SHASTRI NAGAR JAMMU JAMMU KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | L4 | Rejected-Finance L4 | |
| 5 | L5₹34.2 L+₹4.8 L (16.2%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
12 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Jaipur
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
SPECIAL REAPAIR AND REV WORK AT 32 ARMY DOG UNIT UNDER ZONE-II AREA AT JAIPUR MIL STN
2021_MES_483246_1
GE/J-39/2021-22
Open Tender
Civil Works
Item Rate
180 days
Jaipur
As per NIT
5 documents required · 5 mandatory
₹500
GE Jaipur
₹83,000
Yes
31 Dec 2021
23 Oct 2021
14 Nov 2021
23 Oct 2021
12 Nov 2021
6 Nov 2021
23 Oct 2021 - 5 Nov 2021
60 days
Amount
Taking down cement plaster on roof surfaces including roof treatemnt complete all as specified and directed by Engineer-in-Charge.
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight).
M&L for screed plaster 15 mm thick in CM 1:4 on roof surface complete and finished the surface even and smooth without using extra cement etc. complete all as specified and directed
M&L 25 mm thick cement concrete type B-0 (using 12.5mm size graded stone aggregates) average as in RCC roof surface to horizontal and vertical surfaces, finish the surfaces even and smooth using extra cement including necessary form work all as specified and directed.
Supplying and applying fibre reinforced UV resistant elastmeric liquid applied water proofing & heat reflective coating with acrylic polymers and polyster and the coating shall resist 7 bars of water pressure as per DIN 1048 standard , with elongation of 220% as per ASTM D412 & crack bridging of up to 1 mm & with high SRI Value conforming to ASNZ standard. The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes. complete in all respect as per the direction of Engr-In-Charge
S&F suspended false ceiling make Armstong ORCAL extra microperforation size of 600 x 600 x 15 mm Ceiling Tiles over suspension metal system (MICRO LOOK) designer grid (15 mm grid 8mm return) SILHOUETTE X L 15 MM (NOMINAL) of Armstorng make complete or equivalent brand of make including necessary hanging system arrangement which is required to be made from existing RCC roof / stone slab of building incl dismantling of existing ceiling complete all as specified and directed by Engineer-in-Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified & directed.
M&L for brick work with sub-class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone walls incl raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
S&F rendering 10mm thick on fair faces of concrete surfaces in cement mortar 1:3 finished even and smooth without using extra cement as on ceiling surface including chicken wire mess fixed with old rusted TMT bars etc as per directed by Engr-In-Charge
S&F for Rendering 15mm thick cement plaster on fair faces of brick or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and directed.
Dismantling floor, heart or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L rendering 10 mm thick on fair faces of brick work in CM (1:4) complete all as specified and directed.
M&L glazed tiles digital coloured ceramic tiles 300x450x7mm thick in vertical surfaces such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of distemper oil emulsion including chalk whiting complete all as specified and as directed.
M&L complete removal of existing treatment of old plastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted complete all as specified and as directed by Engineer-in-Charge.
M&L for 3mm thick wall care putty on walls complete all as specified and as directed.
M&L Complete removal of existing treatment of walls and applying two coat of cement base paint on walls over and including one coat of alkali resistant priming paint complete all as specified and as directed.
M&L for preparing new plastered ceiling surfaces and applying three coat of white wash complete all as specified and as directed.
M&L for preparing old plastered ceiling surfaces and applying one coat of white wash complete all as specified and as directed.
M&L for preparing new plastered surfaces of walls and applying two coat of cement based paint complete all as specified and as directed.
S&F powder coated any colour (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors/windows/ ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed.
S&F powder coated any colour (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, fixed / sliding type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing,locks, anodised alumnium snap beading, screws etc complete all as specified and as directed.
M&L for 4.0 mm thick sheet glass, ordinary quality and glazing with aluminium beads and rubber gaskit in square exc 0.5 sqm in each pane frosted on one side complete all as specified and directed.
S&F 15 micron coloured aluminium anodised grill design No DG-117,10 mm thick including F Sections complete all as specified and directed. Make :- M/s Deco grill / M/s Royal grill or Equivalent as approved by GE.
S&F aluminium (extruded section) body door closer hydraulically regulated designation No 3, universal type,suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg complete all as specified and directed.
S&F powder coated any colour (minimum thickness of powder coating 50 micron) anodised aluminium door shutter, aluminium section weighing 0.55 kg/m including necessary joining cleat, glazing clips, rubber neoprene packing, handle 2 Nos in doors, hinges, anodised aluminium snap beading etc complete all as specified and as directed.
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of operature 1.40mm and fixed with aluminium wire staples complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area exc 1.50 sqm and n.exc 4.00 sqm each complete all as specified and directed.
S&F 35 mm thick 2nd class hard wood plain,framed,panelled shutters(any number of panels),with panels of timber flat on both sides(feather edged), or of veneered particle board with commercial face venners fitted to chowkhats complete all as specified and directed.
S&F Framed work Fe 410-W(Gde-E- 250) quality-A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete
S&F factory made 35 mm thick, 2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified and directed.
M&L galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid dry and pointed in any mortar complete all as specified and directed.
M&L for 100 mm thickness PCC (1:4:8) type D-2 using 40mm using graded stone aggregate as in sub base of flooring complete all as specified and directed.
M&L machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, with grey cement and pigment laid over and including 25mm thick sand cushion complete all as specified and directed.
M&L pre-cast cement concrete block masonry with solid blocks, exc 10 cm in width and setting in cement mortar (1:4) type B-1 1:2:4 (20 mm graded aggregade) complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Dismantling of asbestos cement (corrugated, semicorrugated etc.) sheets in roof coverings
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed.
M&L for MS rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe 410 (W) (Gde E-250)
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified.
M&L for preparation of new steel & iron surfaces & applying two coats of synthetic enamel paint over 10 cm width or girth etc complete all as specified and directed.
M&L Cement Concrete type C2 1:3:6 (40mm Graded aggregate )in walls or retaining walls,any thickness, size or shape including pilasters, buttresses columns, pillars boundary pillars and posts (including caps and bases), complete all as specified and directed.
Surface dressing n exc 15cm deep in anu type of soil complete all as specified and directed.
M&L Hardcore (broken bricks of boulder) of guage n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L Cement concrete 1:4:8 Type D2 (using 40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade,with grey cement and no pigment complete all as specified and directed.
M&L for providing precast cement concrete 1:3:6 block masonary with solid blocks, exc 10cm in width and setting in cement mortar 1:4 complete all as specified and as directed.
Taking down carefully surface aluminum or copper point wiring from exisitng PVC concealed conduit for (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
M&L for point wiring with 1100 volts grade PVC insulated unsheathed FRLS multistranded copper conductor cable 1.5 single core Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into PVC casing caping of suitable size ISI marked ivory colour with all conduit fittings / fixing accessories and modular PVC box of same make of switch and sockets white in colour mounting cover plates with frame for mounting modular switches, scokets, fan regulators etc as required for one light point controlled by one switch.
All as per item No. 54 here-in-before but one fan point controlled by one switch.
All as per item No. 54 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 54 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
M&L for point wiring with 1100 volts grade PVC insulated unsheated FRLS multistranded copper conductor cable 2.5 Sqmm (Phase-Red, Neutral-Black) single core and earth continuity conductor 2.5 Sqmm (Green) PVC insulated unsheathed multistranded, copper conductor, single core, FRLS drawn into and including PVC casing-capping not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenolic laminated white sheet cover for mounting switches, sockets for one 16 amp socket outlet point controlled by one switch on independent board.
S&F angle holder, insulated polycarbonate body with back plate complete.
Supplying and fixing modular switch one way 6 amp 1 module all as per Legrand Mylinc cat ref no. 675501 or equivalent as approved by GE.
Supplying and fixing modular switch one way 16 amp 1 module all as per Legrand Mylinc cat ref no. 675511 or equivalent as approved by GE.
Supplying and fixing modular socket 6/16 - 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675555 or equivalent as approved by GE.
Supplying and fixing modular socket 6 amp 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675550 or equivalent as approved by GE.
S&F ceiling rose 3 plates polycarbonate body complete.
Supplying and fixing modular hum free electronic step fan regulator, 100 watt 2 module all as per Legrand cat ref no. 675530 or equivalent as approved by GE.
Boxes junctions, plastic, round, four terminals
Supplying and fixing in repair LED batten (1.2 m) made of CRCA sheet housing with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 19 watt (including driver) having colour temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make - Philips cat ref no. ENDURALED BATTEN "BN 108C LED 20S PSU CDL WH" or Bajaj cat ref no. BLTRU 20W WH VIVA or equivalent in other specified make as approved.
Supplying and fixing in repairs LED batten 9 watt, 900 lumens operating voltage 160 to 360 volts, colour temperature 6500K including connection all as per Philips Astra Line 9-Watt LED Batten or equivalent as approved as approved by GE.
Supplying and fixing in repairs LED bulkhead fitting 9 watt IP 66 & IK 09 with polycarbonate body duly prewired connection with 0.75 sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable all as per Philips cat ref no. WT202W LED6S CW PSU S2 PC or equivalent as approved by GE.
Supply, laying, testing and commissioning 1100 volts grade XLPE insulated & PVC sheathed steel tape / wire armoured, underground stranded aluminium conductor cable laid in trenches/ on pole/ through pipe/ fixed on wall of nominal cross sectional area 70 Sqmm 3.5 core complete.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in soft / loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point.
S&F Steel tubes 80 mm bore ISI marked light grade galvanised with all fittings fixed to walls / poles / laid in road crossing etc as required.
M & L for filling clean and dry sand cushioning for cable including punning in trenches complete.
Supply and laying old size bricks, common burnt clay building bricks sub class 'B' designation 75 laid in trenches over sand for cable protection complete.
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 80 mm & inner pipe dia 50 mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth strip 32 x 6 mm, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 8 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 1.0 ohm complete. ( Note - GI strip size 32x6 mm upto 7.5 m included in the item).
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 12 ways. Make - Legrand cat ref no 507611 or equivalent as approved by GE.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with TPN 415 volts, 4 ways. Make - Legrand cat ref no 507670 or equivalent as approved by GE.
S&F MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete. Make - Legrand cat ref no 408587 to 408595 or equivalent as approved by GE.
S&F MCBs of 'C' series SPN 40 to 60 Amp, 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete. Make - Legrand cat ref no 408631 to 408636 or equivalent as approved by GE.
S&F MCBs of 'C' series TPN 100 Amp, 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete. Make - Legrand cat ref no 408704 or equivalent as approved by GE.
M&L for submain wiring with two runs of single core PVC insulated and unsheathed, multistranded FRLS copper conductor of size 4.00 sqmm, LT cable, 1100 volts grade and one run of 4 sqmm single core, multistrand copper conductor (green) as earth continuity conductor drawn into 20 mm dia concealed conduit complete all as specified and directed.
M&L for submain wiring with two runs of single core PVC insulated and unsheathed, multistranded FRLS copper conductor of size 6.00 sqmm, LT cable, 1100 volts grade and one run of 6 sqmm single core, multistrand copper conductor (green) as earth continuity conductor drawn into 25 mm dia concealed conduit complete all as specified and directed.
M&L for of bus bar chamber pedestal type of size 150 cm x 80 cm x 50 cm out door dust & vermin proof front opening made out of 2.0mm thick MS sheet duly painted and consisting with aluminium bus bar 3 phase and neutral 4 Nos 400 Amp fixed on insulators and one MCCB TPN 200 Amp, 25 KA rupturing capacity and one onload change over four pole 100 amp switch including necessary fixed in PCC 1:3:6 using 20 mm graded stone aggregate including danger plate etc complete.
Supply and fix exhaust fan of size 300 mm sweep totally enclosed highly efficient heavy duty motor with pressure dia cast aluminium rotor mounted on two ball bearing and rigid frame with rubber mounting for scilent operation by making suitable arrangement of frame on shed and connect cable from ceiling rose to exhaust fan or as approved by Engineer in charge.
Schedule of Credit
NARAYAN SINGH NARENDRA SINGH AND COMPANY
M/S JALANDRA CONSTRUCTIONS
M/S Mohan Lal Gupta
UNIVERSAL INFRAPROJECT PVT LTD
MSR INFRATECH
Smita Constructions
M/S Anil Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .