Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹50.3 L
EMD Value
₹1.0 L
Closing Date
6 Nov 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Manager
CWC RO LUCKNOW
Electrical upgradation works in godowns no. 1 to 9, office block and ancillary buildings at CW, Gorakhpur
2026_CWC_296409_1
E NIT_CWC/RO-LKO/Engg./26-27/29T
Open Tender
Electrical Works
Percentage
75 days
CW Gorakhpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹1.0 L
7 Nov 2026
30 Oct 2026
7 Nov 2026
30 Oct 2026
6 Nov 2026
30 Oct 2026
90 days
Name of the Bidder
Bidder Address, (registered)
Bidder Organization ID /CIN in case of Company
Bidder Telephone number
Bidder E-mail address
Type of Bidder constituent (Organization)
Attested copy of documents in support of Bidder Organization Type
Current List of Directors/Partners: as applicable
Name of the person holding the power of attorney for this Bid
Designation
Contact details of person holding the power of attorney
Attested Copy of Power of Attorney to sign & submit the Tender (as per format given in EXHIBIT-III of Appendix-II)
Earnest Money Deposit (EMD) of Amount as mentioned in APPENDIX-1 (TIS) through NEFT/RTGS
PF Registration code number of Bidder
COPY of PF Registration number of Bidder
GST Registration code number of Bidder
COPY of GST Registration number of Bidder
PAN of the Bidder
COPY of PAN of Bidder
Whether Enlisted /Empaneled with CPWD/ MES/ Railway/ PWD/ CWC/any other PSU etc. if any,
Copy of Enlistment/Empanelment certificate Submitted or Not
Whether Bidder is executing or completed any work awarded by CENTRAL WAREHOUSING CORPORATION in Past Three FY Year (FY 2023-24, FY 2024-25 & FY 2025-26) and Current FY 2026-27.
Affidavit along with this PQ Performa (EXHIBIT-I) on NJS paper signed and submitted after filling necessary details.
Declaration of near relatives (EXHIBIT-IV) submitted.
Particular Technical Experience w.r.t. Similar Nature of Work:
Brief of Similar Nature Work Experience-1
Work order/ contract agreement ref number and date
Name of client issued the work order and completion certificate
Completion certificate -ref number and date
Total value of work completed (Rs.)
Stipulated date of completion
Actual date of completion
If LD is levied: Amount / period of delay for which Liquidity damage is levied by client (if any)
Copy of completion/experience certificate of work and Copy of Agreement/Workorder issued by Client is submitted as per format given in EXHIBIT-V or EXHIBIT-VI or EXHIBIT-VII as applicable
Brief of Similar Nature Work Experience-2
Work order/ contract agreement ref number and date
Name of client issued the work order and completion certificate
Completion certificate -ref number and date
Total value of work completed (Rs.)
Stipulated date of completion
Actual date of completion
If LD is levied: Amount / period of delay for which Liquidity damage is levied by client (if any)
Copy of completion/experience certificate of work and Copy of Agreement/Workorder issued by Client is submitted as per format given in EXHIBIT-V or EXHIBIT-VI or EXHIBIT-VII as applicable
Brief of Similar Nature Work Experience-3
Work order/ contract agreement ref number and date
Name of client issued the work order and completion certificate
Completion certificate -ref number and date
Total value of work completed (Rs.)
Stipulated date of completion
Actual date of completion
If LD is levied: Amount / period of delay for which Liquidity damage is levied by client (if any)
Copy of completion/experience certificate of work and Copy of Agreement/Workorder issued by Client is submitted as per format given in EXHIBIT-V or EXHIBIT-VI or EXHIBIT-VII as applicable
Annual Financial Turnover-Total Revenue (Income) (as per CA certificate and audited P&L Account)
FY 2022–23 (only when audited turnover for FY 2025-26 is not available)
The average of financial turnover for the last three financial years i.e. FY 2025-26, FY 2024-25 and FY 2023-24 Or FY 2022-23 (FY 2022-23 to be referred only when Audited turnover of FY 2025-26 is not available)
CWC/RO-LKO/Engg./26-27/29T
Electrical upgradation works in godowns no. 1 to 9, office block & ancillary buildings at CW, Gorakhpur
Sub-Schedule-I E&M DSR 2025
Total CWC estimated Cost for this schedule including Cost Index, labour cess & applicable GST (Rs.) ₹ 40,03,329.39
CWC/RO-LKO/Engg./26-27/29T
Electrical upgradation works in godowns no. 1 to 9, office block & ancillary buildings at CW, Gorakhpur
Sub-Schedule -II: E&M MR ITEMS
Total CWC estimated Cost for this schedule including Cost Index, labour cess & applicable GST (Rs.) ₹ 10,27,909.00
CWC/RO-LKO/Engg./26-27/29T
Electrical upgradation works in godowns no. 1 to 9, office block & ancillary buildings at CW, Gorakhpur
Breif of Schedules
SCH_I (E&M DSR 2025)
Sch_II (E&M MR)
Description
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3x1.5 sq. mm
4x1.5 sq. mm
5x1.5 sq. mm
6x1.5 sq. mm
3x2.5 sq. mm
6x2.5 sq. mm
3x4.0 sq. mm
6x4.0 sq. mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way, Doble door
8 way, Doble door
12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
4 way (4 + 12), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, "C" Curve, Miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Double Pole
Triple Pole and Neutral
Supplying and fixing following rating, four pole, three phase and neutral, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
100 A,30KA,FPMCCB
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP MCB , in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, tetsing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Meter
Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.=0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 50Watt
Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.=0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 100Watt
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 80mm dia
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1 mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3 mm MS Flat Clamp)
Supplying and making end termination with brass compression gland and aluminium lug for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV garde as required.
3½ X 35 sq. mm (32mm)
3½ X 70 sq. mm (38mm)
4 X 16 sq. mm (28mm)
3X 10 sq. mm (22mm)
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Brush Less Direct Current (BLDC) Fan with Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (a) 1200mm, service value = 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Description
Supply and fixing of 20 mm dia flexible corrugated metal/GI conduit as required
Supply, installation, testing and commissioning of LED well glass fixture with following wattage rating and as per technical specifications attached, including accessories for support on wall, bracket, truss, or suitable hanging arrangement upto 1 meters, and 1 meter FR PVC insulated copper conductor flexible cable of size 1.5 sq. mm, complete as per instructions of official-in-charge. . Make : Havells Jeta Iris/Crompton/ Bajaj/ Philips or eq. 70 watt
Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.(a) 3.5x70sqmm
Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.(a) 3.5x35sqmm
Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.(a) 4x16sqmm
Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.(a) 3x10sqmm
Supply, installation, testing and commissioning of cubical type LT outdoor feeder pillar, AC Supply system, fabricated in from CRCA Sheet steel of 2 mm thichness for frame work and covers, 3 mm thickness for gland plates including cleaning and finishing complete with 7 tank process for powder coating in approved shade, having bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, entire panel shall have a common GI earth bar of size 25mm x 5mm at the rear with 02 Nos. earth stud, solid connections from main bus bar to switch gears with reputed size of AL. bus bars and control wiring with 1.5 sq. mm PVC insulated copper conductor single core cable, cable alleys, cable gland plate, canopy and dust and vermin proof door in the front etc./ including providing following switch gears & bus bar -
Supplying of 230 mm sweep 230 volts exhaust/ ventilation fan. As required.Make : Havells, Model : Ventilair DSP 230mm Exhaust Fan or equivalent in Bajaj, crompton as per direction of EIC.
Supply & installation of 18/20 Watt 4 feet LED T8 Tube light (Poly carbonate make) as per required specification and as per instructions of official-in-charge.
Supplying, fixing and commissioning of IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source Gate light complete with all accessories and connection etc as reqd.Make: Havells, Model: RUBYMINIPT15WLED757PSYMTOPC or equivalent in Bajaj, Crompton as per direction of EIC.
Supply of PVC insulated/inner sheathed, Copper conductor,LT XLPE cable, 1.1 Kv grade, steel strip armoured as per IS 7098 (part-1)-1988 with up to date amendments, of following size as required (a) 3 core X 2.5 sqmm (Make: Polycab, havells, Grandley, KEI, RR cable.
Supply, Installation, Testing and Commissioning Wall Mounted Fan of 400mm sweep on wall with 1.5sqmm wire etc complete suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
400mm Sweep Wall Mounted Fan make Havells/Crompton/ Bajaj
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.20 MB
NIT29T.pdf
Tender Documents • 5.18 MB
TechBid29T.xls
Additional Documents • 0.05 MB
Pricebid29T.xls
Additional Documents • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .