Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC 1001 B BHAVESHWAR BLDG NO 03 BHAVESHWAR LANE GHATKOPAR EAST MUMBAI 400077 | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹12.5 L+₹1.4 L (12.6%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹16.7 L+₹5.5 L (49.6%)Rejected-AOC GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L3 | Rejected-AOC REJECTED |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
8 Nov 2021, 6:00 pmClosed
GARRISON ENGINEER NORTH MUMBAI
GARRISON ENGINEER NORTH MUMBAI - 400029
8945 SPECIAL REPAIRS TO LT UG CABLE,FEEDER BOX, LT PANEL, APFC PANEL AND ALLIED WORKS AT KALINA AND JUHU UNDER GE NORTH MUMBAI
2021_MES_480855_1
8945/E8
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER NORTH MUMBAI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER NORTH MUMBAI
₹29,000
Yes
25 Nov 2021
9 Oct 2021
10 Nov 2021
9 Oct 2021
8 Nov 2021
24 Oct 2021
10 Oct 2021 - 23 Oct 2021
Amount
Excavation in trenches, not exceeding 1.50 m wide and not exceeding 1.5 m in depth, for foundation, cable trenches etc, not exceeding 10 sqm on plan and getting out hard/dense soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layer not exceeding 25cm in soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
Supplying and spreading in trenches dry clean crushed stone sand for cable cushioning and gently punning down in layers complete all as specified and as directed by Engineer-in-Charge. Note : Thickness of sand cushioning shall be measured after punning and consolidating of dry clean crushed stone.
Supplying and laying unreinforced precast concrete cable covers, class LV type, flat of size 250mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge. Make : Mehtab Tiles, Indore/M/S Ultra Tiles/NITCO/Topaz Tiles/Navya Tiles, Jodhpur
Supply, lay, test and commissioning of LTUG, XLPE insulated, heavy duty, 1100V grade electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-Charge of following sizes:- Make: PARAGON/FINOLEX/PLAZA/POLYCAB/KALINGA/HAVALLS Note : Earthwork excavation sand cushioning cable cover GI protection pipe shall be measured and paid separately in their respective items
50 Sqm x 3.5 core
95 Sqm x 3.5 core
120 Sqm x 3.5 core
Material and labour for Earthing complete with Galvanized steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to and including galvanized earth strip 32 x 6mm, 7.5m long, by means of bolts, nuts, check nuts and washers made out of galvanized iron or steel with provision of charcoal & common salt packed up to minimum 300 mm all around the earth plate, and protected by 40 mm bore light grade galvanized iron pipe and connected to control board / panel / equipment complete all as shown in electrical plate No.3 of MES schedule Part I with PCC pit in PCC 1:2:4 type B1 using 20 mm graded stone aggregate, MS angle iron frame of size 50mm x 50mm x 5mm, cast iron cover with locking arrangements, GI pipe 20 mm bore medium grade and CI funnel with wire mesh for watering arrangement including necessary excavation and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge.
Supply and fix GI earth stip of size 32 x 6mm buried in ground, extension of existing earthing lead all as specified and as directed by Engineer-in-charge.
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-Charge.
Supply and fix galvanized iron pipe, medium grade, 50mm bore for cable protection on wall, trenches, road crossings etc. with suitable size of GI saddle, wherever necessary including taking down existing etc complete all as specified and as directed by Engineer-in-Charge. Make: TATA/SWASTIK/JINDAL/Bharat Steel tube/ZENITH/Indian Tube Company
Supply and fix galvanized iron pipe, medium grade, 80mm bore for cable protection on wall, trenches, road crossings etc. with suitable size of GI saddle, wherever necessary including taking down existing etc complete all as specified and as directed by Engineer-in-Charge. Make: TATA/SWASTIK/JINDAL/Bharat Steel tube/ZENITH/Indian Tube Company
Supply, installing, testing and commissioning of Automatic Power Factor Correction (APFC) panel indoor type factory made of 125 KVAR capacity ready to use design confirming to IS 5039 / IS 8623 and relevant IS / IEC Codes rated for short circuit rating of 35 KA, front openable and lockable by keys having louvers and air vent, gasket and totally vermin proof and suitable for 415/440 V, 3 phase 50 Hz, AC and housed in elegant enclosure fabricated from minimum 2.00 mm thick CRCA sheet and min 1.6 mm thick for partitions anti corrosive coating to improve power factor to 0.99 and finally powder coated in texture siemens grey RAL 7032 as complete all as specified and as directed by Engineer-in-Charge with comprising of following accessories including suitable size and length of copper conductor cable PVC insulated, from main panel to APFC panel for connections as approved :-
Material and Labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size all as spd and directed by Engineer- in- Charge.
Supply, installation, testing and commissioning suitable size of LT feeder piller box out door, double door, cubical and compartmentalized type, 415 volts, AC, 50Hz, factory fabricated, dust and vermin proof, made out of non corrosive 3mm thick CRCA sheet out side and 2 mm thick sheet inside, complete with and including mounted on angle iron frame of size 40mm x 40mm x 6mm and 50 cm long , four legs grouted in PCC (1:2:4) type B1 (Using 20mm graded stone aggregate), spray painted inside and outside powder coated of approved colour by Engr-in-Charge enclosed busbar chamber with Aluminium bus bar of suitable size mm for phase and neutral (04 Nos strip of suitable rating, capacity and Amps) mounted on PVC insulators, electric connection complete with from MCCB to main bus bar, cable glands, thimble complete with and including openable shutters butt hinged, locking arrangement, including PCC work, excavation & earth work complete comprising M&L for following item including taking down old rusted unserviceable feeder piller box with accessories after disconnecting complete all as specified and as directed by Engineer-in-Charge:-
Material and labour for painting the old Main LT panel board including scraping and removing the old painted surfaces and painting /matching the same colour paint including two coats of super enameled paint and without distrubing the existing electric system all as specified and directed by Engineer-in-Charge.
Supply and fix LED Indicating lamp of main supply indicating 'R', 'Y', 'B' (set of three) complete all as directed by by Engineer-in-Charge.
NANGIA AND CO
joshua construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .