| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC SCF 237 SWASTIK VIHAR NEAR TRINITY HOSPITAL ZIRAKPUR 140603 PUNJAB | S A S NAGAR | PUNJAB | 140603 | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.5 L+₹10,444 (0.84%)Rejected-AOC INSIDE KL PARK W NO 37 IN MOGA CITY | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical ARRORIAN STREET DISTT PATIALA | - | Rejected-Technical Non Responsive |
Tender Value
Refer Docs
EMD Value
₹26,500
Closing Date
30 Dec 2019, 5:00 pmClosed
Executive Engineer
Room No. 209, 1st Floor, Sub Divisional Complex Rajpura
PROVIDING AND INSTALLING NEW TUBEWELL 250X150 MM UPTO 200 MTR. DEPTH, GRAVEL PIT, PUMPING MACHINERY AND RISING MAIN ETC. AT WATER SUPPLY SCHEME VILLAGE FATEHPUR RAJPUTTAN, BLOCK SANOUR, DISTT. PATIALA
2019_WSS_42127_1
WSS Fatehpur Rajputan Block Sanour
National Competitive Bid
Civil Works - Water Works
Item Rate
60 days
WSS Division Rajpura
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
TIA
₹26,500
21 Jul 2020
19 Dec 2019
31 Dec 2019
19 Dec 2019
30 Dec 2019
19 Dec 2019
Amount
Drilling of 650mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. complete in all respect.
Drilling of 650mm dia bore with Reverse Rotatry Rig Upto 150 m depth BGL.
Drilling of 650 mm dia bore with Reverse Rotatry Rig Beyond 150 m depth up to 300 Mtr
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc. complete in all respects.
Supplying, lowering of MS pipe as per IS: 4270-2001 including MS Sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
250mmnominal diameter (weight 52.3 kg per metre) 8.0 mm thickness
150mm nominal diameter (weight 21.6 kg per metre) 5.4 mm thickness
Providing and fixing M.S. taper / reducer made out of 6 mm thick M.S. sheet complete in all respect.
Reducer 250mm x 150 mm
Supplying, fixing & lowering of stainless steel cage type wire wound screen as per IS: 8110-2000 or latest ISI Marked, duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore.
150mm internal diameter (slot size 0.50) 6.30 mm thick
Supplying, fixing and lowering of stainless steel sockets as per IS:8110-2000 or latest, ISI Marked duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respect.
150 mm internal diameter
Supplying and fixing of bail plug of M.S pipe complete with inverted U-hook attached to the bottom plug complete in all respect.
150mm internal diameter (weight 21.6 kg per metre) 5.4 mm thickness
Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S bar complete in all respect.
Supplying & fixing of well cap having thread to fix on housing pipe complete in all respect.
250mm internal diameter
Supplying and fixing mild steel clamps of 6" x ½ (150mm x 12mm ) mild steel flat 5 ft (1.52 mtr) long suitable to fit the housing pipe including the cost nuts & bolts of suitable size complete in all respects..
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S pipe duly welded with suitable grade welding electrode complete in all respect.
150mm internal diameter
Supplying at site Wooden Box of Suitable size with Lid & locking arrangement for preserving strata sample colleted from the bore.
Supplying at site, gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore. The Gravel should be free from, dust, dirt or the vegetable manner as per IS 4097/1967 with latest amendiments (to be paid as per actual lenght of pipe) including Carriage.
Development and Stablizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumble to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 550 cfm at 600 PSI
Development and Stablizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumble to the satisfaction of Engineer-in-charge.
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)
Testing of Water sample for heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.).
Construction of Gravel Pit outside the Pump Chamber. (0.90m Dia.) as per standard design & drawings of public health department.
Providing, Laying, fixing & jointing of P.V.C Pipes as per ISI- 4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete including excavation & back filling leveling complete in all respect as per specifications. PVC pipe 160mm o/d rising main (10Kgf/sqcm)
Provision for making connection with existing pipe line complete in all respects.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). (150mm i/d)
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.9 m. x 0.9 m.
i) Providing & Installing Testing & Commissioning of One No. Electrically driven Sub. Pumping set of approved make capable of delivering 389 Lpm against a head of 112 mtr (17.50 BHP) complete including 2 nos earthing as per specifications attached ii) PITC Electric control panel consisting of electric appliances such as automatic STAR Delta Push Button or oil immersed Starter, Main Switch. Volt Meter, Ampere Meter, ELCB, Shun Capacitor, Single Phase Preventer, Indicating Lamps, Kit-Kat etc.complete as per specifications attached. iii) PITC of 4mm2 size submersible cable complete as per specifications attached v) PITC of double flanged G.I column pipe of size 3", 75 mtr in approximately 3 to 4 mtr long peaces including specials, ISI marked (medium class) reputed make i.e jindal/Tata equvalent installing complete as per specifications.
Provision for Submersible Cable 4mm2 thick from existing Tubewell to proposed New Tubewell. (25x2 = 50 mtr.)
Providing & Installing 150 mm dia delivery main (from Tubewell to duck foot bend including cost of C.I D/F Pipes,, D/F Sluice Valves, D/F NRV & Specials as C.I. Bends , Tail Piece Tees etc. inside the Pump Chamber as per standard design complete in all respects.
Credit of old C.I delivery main 100mm i/d
Credit of old dismantled Sluice valve
Goyal Tubewell store
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .