Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC DSS 194 POCKET A SEC 14 125001 | HISAR | HARYANA | 125001 | ₹26.6 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical SCO 47 2ND FLOOR SECTOR 11 134109 | PANCHKULA | HARYANA | 134109 | - | - | Rejected-Technical Not Eligible |
Tender Value
₹26.6 L
EMD Value
₹53,173
Closing Date
19 Sept 2024, 5:00 pmClosed
PRAMESH Kumar
ED - Hisar
Providing Fire Fighting System in Uddham Singh Jain Civil Hospital in Charkhi Dadri (Pdg. Fire Alarm System only) RECALL
2024_HRY_401893_1
202486258AAC 1C80 4957 9A7E 898976A9A5F6666BAR
Open Tender
Electrical Works
Works
90 days
Charkhi Dadri
2 documents required · 2 mandatory
₹5,000
₹53,173
Yes
22 Nov 2024
11 Sept 2024
20 Sept 2024
11 Sept 2024
19 Sept 2024
11 Sept 2024
Amount
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
SITC of 3 Loop Panel expandable upto 6 Loops Micro processor based 2 wire fault tolerant loop,with inbuilt network port (each loop accessing 99 detectors and 99 modules ) fire alarm/detection control panel. The Panel shall have 10000 event log history . Panel shall be capable of having 1600 configurable zones .The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFFrespective control module when ever any alarm is triggered. The panel shall have 7 Inch Touch Screen unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have provision for 40 Zones with Individual LED Indicators expdable upto 200 Zones. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/UL/VDS The panel shall support detection logics like coincidence and verification detections for the false alarm management. The Panel shall adjust the sensitivity between day and night to maintain the better detection/reponse time.The panel shall have plug in connectors/terminals for the quicker installation/maintanance. The Panel shall be cpabale of programming through PC : Touch Screen of USB . as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. Makes: G.S.T / Siemens /Honeywell Moreley.(Rate are excluding of GST)
`SITC of Analog Addressable type Active Repeater Fire Alarm panel with 7 inch Touch Screen, having Controls For Reset, Mute, Accept , Silence alarms and Self Test Conforming to EN Stardard. Operating Voltage 18 to 32 Vdc and Operating Temperature is plus 5°C to plus 45°C with all labour and materials required to complete the job in all respect up to the entire satisfaction fo engineer-in-charge of work. ).Makes: G.S.T / Siemens /Honeywell Moreley.(Rate are excluding of GST)
SITC of addressable Photoelectric detector including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Makes: G.S.T / Siemens /Honeywell Moreley.. (Rate are excluding of GST)
Supply, installation, testing and commissioning of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Makes: G.S.T / Siemens /Honeywell Moreley. (Rate are excluding of GST)
Supply, installation, testing and commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Makes: G.S.T / Siemens /Honeywell Moreley. (rate are excluding of GST)
Supply, installation, testing and commissioning of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Makes: G.S.T / Siemens /Honeywell Moreley. (Rate are excluding of GST)
Supply, installation, testing and commissioning of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Makes: G.S.T / Siemens /Honeywell Moreley. (Rate are excluding of GST)
SITC of Intelligent Analog Addressable type Response Indicator with all labour and material required to complete the job in all respect Makes: G.S.T / Siemens /Honeywell Moreley. (Rate are excluding of GST)
Supply Installation, Testing and Commissioning of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener Managed Type including cost of labour and material required to complete the job in all respect.Make Omex/ Savmax . (Rate are excluding of GST)
Wiring for Fire Alarm system with the following sizes of FRLS insulated copper conductor Double core 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required. Make Finolex/Havel/Polycab. 2x1.5 sq mm (Rate are excluding of GST)
Supply of minimum 1000 Mtr. Range Siren generatorprovided at the roof of the building with separate power suppl, relay etc.. Make: National/Kheraj (Rate are excluding of GST)
Mechnical foam Type Fire Extinguisher 50 Leter capacity with OUTSIDE CYLINDER , CO2 CYLINDER 1 KG CAPACITY for Above AFFF foam compound for extinguisger , 3000 mls capacity combine . Make Safex / SAVEMAX / CEASEFIRE . (Rate are excluding of GST)
3 Meter Rubber pipe with EPDM Quality with squzeer grip nozzle for Jet length I.S.I Mark Make Safex / SAVEMAX / CEASEFIRE (Rate are excluding of GST)
Supply, installation, testing and commissioning of Class D amplifier 750 watts Frequency response: 60 Hz to 15 khz ( plus 1/3db), Inputs :XLR and phone jack , Input 1, Input 2-4, Impendence :20kO, Sensitivity : 1 V balanced , S/N ): )85 dB complete in all respect Make: JBL/ Honeywell/ Ahuja. (Rate are excluding of GST)
Supply, Installation, Testing and commissioning of Wall Mount/Ceiling Speaker with operation 15 Watts to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. Make: JBL / Honeywell/ Ahuja. (Rate are excluding of GST)
Supply, Installation, Testing and commissioning of Horn Loudspeaker made with ABS, watered dust protected to IP 65,Sound pressure level at 15W/1W - 115/103 dB (SPL), Effective frequency range 500 Hz to 5 kHz, Rated power 15W to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. Make: JBL / Honeywell/ Ahuja. (Rate are excluding of GST)
Supply of Speaker Cable in all respect . Make Finolex / Grandly / Plycab. (Rate are excluding of GST)
Supply of ABC Stored Preassure type Fire Extinguisher 6kg. Capacity (5 year warranty) bearing ISI Mark for fire fighting ABC class of fire extinguisher will be manufactured strictly as per BIS IS:683:2006 bearing ISI Mark EN3 615 approved powder(Make:Safex / Savemax/Ceasefire) (Rate are excluding of GST)
Supply of Co2 type Fire Extinguisher 4.5Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Squeeze Grip type valve with initial Charge as per IS: 15683:2006 specification, bearing ISI Mark (Make:Safex / Savemax/Ceasefire) (Rate are excluding of GST)
`SITC of 12 U rack with cable manager, fan tray, power distribution kit complete in all respect. Make: HCL/Cormack/Wallrack/Netrack (Rate are excluding of GST)
Supply Installation Testing and Commissioning of 1 KVA UPS Overvoltage cut-off device (OVCD),Support for Generator Compatible with Wide Input. Wide Input Voltage window (110 – 280Vac) for IndianEnvironmental Condition andfor Optimized BatteryPerformance. UPS would support SNMP Mnagaer and web browser On Line With 2 hour Backup MAKE APC/EINOVA/MICROTEK. (Rate are excluding of GST)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .