Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 CrAccepted-AOC HOUSE NO 59 ZOO NARENGI ROAD GEETANAGAR GUWAHATI 781021 ASSAM | KAMRUP METRO | ASSAM | 781021 | ₹9.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹9.4 Cr+₹14.1 L (1.53%)Rejected-AOC BARPETA | BARPETA | ASSAM | 781301 | ₹9.4 Cr+₹14.1 L (1.53%) | L2 | Rejected-AOC L2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹18.4 L
Closing Date
17 Feb 2021, 2:00 pmClosed
Chief Engineer PWD (Roads), Assam, Ghy-3
O/o the C.E. PWD (Roads), Assam, Ghy-3
River front development of (1) Gariajan River (2) Sumdiri River and (3) Khokkorijan River at North Lakhimpur under CIDF for the year 2019-20
2021_PWD_21030_1
CE/Commn/UDD/38/20-21/2_CIDF
Open Tender
Civil Works – Roads
Item Rate
270 days
Lakhimpur
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,000
Yes
Empowered Officer, Assam State Road Board
₹18.4 L
Yes
2 Aug 2021
6 Feb 2021
17 Feb 2021
6 Feb 2021
17 Feb 2021
6 Feb 2021
6 Feb 2021 - 17 Feb 2021
Amount
GARIAJAN RIVER Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. A) Upto a depth of 2 mts. below the existing Ground Level a)In ordinary Soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
P.C.C WORKS Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level. (a) Using 38mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (i) Using 38mm thick plank
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) B) In super structure from plinth level up to 1st floor level. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. M25 grade concrete
Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding, providing face stone, through stone and centering including racking of joints, curing and supplying and all carriage of stone as directed including payment of forest royalty and sales tax and carriage. (a) Random Rubble Masonry
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side a) In cement mortar 1:3
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
CEMENT PAINT & PRIMER b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
PLASTER OF PARIS & WALL PUTTY Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed.
EXTERIOR PAINTS / COATINGS Finishing wall with two coat s of acrylic emulsion exterior paint of approved brand of required shade thinning by adding water as per the specification of manufacture after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department. Asian paint/ Berger paint/ ICI paint / J& N paint / Nerolac
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. .
STEEL RAILING Providing and fixing Stainless Steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of Stainless Steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered) Total Railing 2.5 kg /Rm
Providing and fixing M.S. Tube hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer complete as specified and directed by department. Total Railing 35 kg /Rm
Construction of Sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts & leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2 (including compensation of earth ). (Including cost of testing of materials at site and laboratory as directed by the deptt.) a) from Government land
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD.
TREE PLANTING Supplying and planting of ornamental trees (1'-0" height sapling) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . SHADE TREE (A) Neem / Mahaneem / Beef wood / Bakul / Acacia / Siris / Devils tree / Kadam / Palash / Pink Cassia / peepal / Silver oak / Simalu / Ajar
Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
Surface dressing of ground including removing vegitation and/ or undulation of ground not exceeding 150mm deep and disposal of rubbish outside the periphery and lift up to 1800mm in all kinds of soil.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
TREE PLANTING Supplying and planting of ornamental trees (1'-0" height sapling) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . SHADE TREE B) KAnchan/NAhar/Arjun
KHOKKORIJAN RIVER (Market Place) EARTH WORK Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2 mts. below the existing Ground Level (a)In ordinary Soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
P.C.C WORKS Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
REINFORCED CEMENT CONCRETE WORKS Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) i)Using Mixer Machine A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture, plasticiser b)M20 grade concrete or Prop. 1:1.5:3
REINFORCED CEMENT CONCRETE WORKS Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) i)Using Mixer Machine B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. (N) Without using admixture, plasticiser b)M20 grade concrete or Prop. 1:1.5:3
TIMBER SHUTTERING (FORMWORK) Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. b)Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level. b)Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, pillars, posts and struts a) Square, Rectangular, polygon in plan or any shape like Tee/L etc. having plane vertical face. b)Using 25mm thick plank
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. a)For depth not exceeding 1.0M.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. a) Floors etc. upto 200mm in thickness.
BRICK WORK: Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. II) In superstructure above plinth level up to 1st floor level. B) In proportion 1:4.(1 cement:4 sand)
Kota-stone slab flooring of 18 mm thick over 20mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (2) 600mm x 900mm and above
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/ Jindal steel/Shyam steel/RINL ii) Super Ductile (SD) TMT reinforcement bars
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. On fair side a) In cement mortar 1:3
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed.
CEMENT PAINT & PRIMER a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.c) Asian paint/ Berger paint/ ICI paint
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. b) Using other ISI marked approved brand tube
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (ii) 0.45 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (ii) 0.45 mm thick
GYPBOARD CEILING Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. (ii) Using 6 mm thick FC Board
Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
TREE PLANTING Supplying and planting of ornamental trees (1'-0" height sapling) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . SHADE TREE B) KAnchan/NAhar/Arjun
KHOKKORIJAN RIVER (Market Place) (ELECTRIFICATION) Wiring to a Light/Fan/Call Bell point with 2X1.5 sq.mm. PVC Insulated single core unsheathed industrial (Multistrand) cable F.R. conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade upto 1100 V olts ( Finolex/ RR Kabel or equivalent make as approved by the Deptt) in surface/recessed conduit wiring system with 20 mm dia 2 mm thick/heavy rigid IS : 9537 Part III conduit ( Berlia/AKG/Precision/ Presto Plast/ Polycab/MW or equivalent make as approved by the Deptt.) including 6 Amps flush Type Switch/bell push ( Anchor Penta/ Gold Medal / Kolor kany.kom /Havels or equivalent make as approved by the Deptt.) GI/MS switch board (ISI marked) with Phenolic laminated sheet cover ceiling rose ( Anchor penta / Gold medal / Kolor kany.kom / Havels or equivalent make as approved by the Deptt. Etc.complete. medium point upto 6mtr length
Wiring to a Light/Fan/Call Bell point with 2X1.5 sq.mm. PVC Insulated single core unsheathed industrial (Multistrand) cable F.R. conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade upto 1100 V olts ( Finolex/ RR Kabel or equivalent make as approved by the Deptt) in surface/recessed conduit wiring system with 20 mm dia 2 mm thick/heavy rigid IS : 9537 Part III conduit ( Berlia/AKG/Precision/ Presto Plast/ Polycab/MW or equivalent make as approved by the Deptt.) including 6 Amps flush Type Switch/bell push ( Anchor Penta/ Gold Medal / Kolor kany.kom /Havels or equivalent make as approved by the Deptt.) GI/MS switch board (ISI marked) with Phenolic laminated sheet cover ceiling rose ( Anchor penta / Gold medal / Kolor kany.kom / Havels or equivalent make as approved by the Deptt. Etc.complete. long point upto 10 mtr length
Wiring to a 5 pin 6 A plug point with 1.5 sq.mm. PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS 694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100V (Finolex/ RR Kabel or equivalent make as approved by the deptt.) in surface /recessed 2 mm thick/heavy rigid ISI marked IS : 9537 PART III rigid PVC conduit (( Berlia/AKG /Precision/ Presto Plast/ Polycab/MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 A flush type plug socket and 6 A F/T switch (Anchor penta/ Gold Medal/Kolor kany.kom/Havels or equivalent make as approved by the deptt.), GI/MS switch board (ISI marked with phenolic laminated sheet cover including earth continuity with 1.5 sq.mm. cable to third point of the plug socket etc. as required complete, when placed elsewhere. Medium point up to 6 Mtr. Length
Wiring for 5/6 pin 16 A plug with 4 sq.mm. PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS 694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100V (Finolex/ RR Kabel or equivalent make as approved by the deptt.)in surface/ recessed conduit wiring system including 5/6 pin 16 A socket outlet (Anchor penta/ Gold Medal/Kolor kany.kom/Havels or equivalent make as approved by the deptt.) and 16 A flush type switch (Anchor penta/Gold Medal/Kolor kany.kom/ Havels or equivalent make as approved by the deptt.) GI/MS switch board (ISI mark with Phenolic laminated sheet cover earth continuity with 2.5 sq. mm. cable to the third pin of the socket as required complete with 20 mm dia 2 mm thick heavy rigid ISI marked IS : 9537 Part III rigid PVC conduit (Berelia/AKG/ Precission /Presto Plast /Polycab/MW or equivalent make as approved by the Deptt.) Extra long point up to 15 meter length
Wiring for circuit wiring with PVC insulated Single core unsheated industrial (Multistrand) cable FR conforming to IS 694:1990 with flexible bright annealed electrolytic copper conductor for voltage up to 1100 V (Finolex/RR kabel or equivalent make as approved by the deptt) in surface/recessed PVC conduit (Berlia/AKG/precission/Presto Plast/Polycab /MW or equivalent make as approved by the deptt) wiring system with 3 X 1.5 sq.mm. P.V.C. insulated cable in 20 mm. dia rigid conduit
Wiring for drawing Sub-Main Line with PVC Insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS 694:1990 with flexible bright annealed electrolytic copper conductor for voltage up to 1100 V (Finolex/RR kabel or equivalent make as approved by the deptt) in surface/ recessed PVC 20 mm dia 2 mm thick heavy ISI marked IS 9537 Part III rigid PVC conduit (Berlia/AKG/precission/Presto Plast/Polycab /MW or equivalent make as approved by the deptt) wiring system. With 4 X 4 sq.mm. + earth continuity with 2X2.5 sq.mm.cable in 25 mm dia 2 mm thick/heavy rigid PVC IS : 9593 part III conduit.
With 4 X 6 sq. mm + earth continuity with 2 X 4 sq. mm cable in 32mm. Dia. 2mm thick/ heavy rigid PVC IS: 9537 Part-III conduit
Supplying including fitting and fixing of following Metal boxes for MODEL RANGE LEGRAND(ARTEOR), ANCHOR(AVE), MK(BLENZE), SCHNEIDER(ZENSELO), CRABTREE(MURANO) in surface/recessed system complete as per direction of department. 1-2 module type metal
Supplying including fitting and fixing of following Metal boxes for MODEL RANGE LEGRAND(ARTEOR), ANCHOR(AVE), MK(BLENZE), SCHNEIDER(ZENSELO), CRABTREE(MURANO) in surface/recessed system complete as per direction of department. 1-2 module type metal 8 module type metal
Supplying including fitting and fixing of following Metal boxes for MODEL RANGE LEGRAND(ARTEOR), ANCHOR(AVE), MK(BLENZE), SCHNEIDER(ZENSELO), CRABTREE(MURANO) in surface/recessed system complete as per direction of department. 1-2 module type metal 12 module type metal
Supplying including fitting and fixing of following MODEL RANGE LEGRAND(ARTEOR), ANCHOR(AVE), MK(BLENZE), SCHNEIDER(ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department 2 module
Supplying including fitting and fixing of following MODEL RANGE LEGRAND(ARTEOR), ANCHOR(AVE), MK(BLENZE), SCHNEIDER(ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department 8 module
Supplying including fitting and fixing of following MODEL RANGE LEGRAND(ARTEOR), ANCHOR(AVE), MK(BLENZE), SCHNEIDER(ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department 12 module
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof double door(IP-43) surface mounting vertical TPN MCB DB incorporated with bas- bar 125A, neutral link, earth bar and din rail etc fitted on wall with grouting nuts and bolts as required complete with making necessary connection as approved, specified and directed by the deptt. (Richa, Bentec, Adhunic/ equivalent make) 8 way TPN (8+24) double door
Premium Model 1400 mm sweep (ORIENT /PSPO make)/Premium model 1400 mm sweep SS-390 Deco(havels make)
Supplying including fitting and fixing of following A.C. exhaust fan in the existing hole on the wall of following sweeps with making necessary connections as approved by the Deptt. As required complete and as directed by the department. Power Flow 225mm sweep(ORIENT make)
Supplying including fitting and fixing of following A.C. wall fan in the existing hole on the wall of following sweeps with making necessary connections as approved by the deptt as required complete and as directed by the department ORIENT or equivalent USHA make Supplying fitting fixing of ceiling fan regulator including connections etc complete as required
KHOKKORIJAN RIVER (RCC Drain) Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Upto a depth of 2 mts. below the existing Ground Level In ordinary Soil
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE WORKS Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Using Mixer Machine In substructure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. Without using admixture, plasticiser c) M25 grade concrete
TIMBER SHUTTERING (FORMWORK) Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level. Using 25mm thick plank
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. Brick on flat soling.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) From Primary Producer: TATA/SAIL/ Jindal steel/Shyam steel/RINL Super Ductile (SD) TMT reinforcement bars
CEMENT PLASTERING 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. On fair side In cement mortar 1:3
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Khokkorijan Road RCC DRAIN COVER Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Using Mixer Machine In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. Without using admixture, c) M25 grade concrete
TIMBER SHUTTERING (FORMWORK) Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level. Using 25mm thick plank
STEEL WORK Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) From Primary Producer: TATA/SAIL/ Jindal steel/Shyam steel/RINL Super Ductile (SD) TMT reinforcement bars
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. on fair side In cement mortar 1:3
Sunmidiri River Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Upto a depth of 2 mts. below the existing Ground Level In ordinary Soil
P.C.C WORKS Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level. (a) Using 38mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (i) Using 38mm thick plank
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) B) In super structure from plinth level up to 1st floor level. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. M25 grade concrete
Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding, providing face stone, through stone and centering including racking of joints, curing and supplying and all carriage of stone as directed including payment of forest royalty and sales tax and carriage. (a) Random Rubble Masonry
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. .
Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
Surface dressing of ground including removing vegitation and/ or undulation of ground not exceeding 150mm deep and disposal of rubbish outside the periphery and lift up to 1800mm in all kinds of soil.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
TREE PLANTING Supplying and planting of ornamental trees (1'-0" height sapling) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . SHADE TREE
M/s Macrocosm Builders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .