Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L1 | Accepted-AOC lowest bid qouted | |
| 2 | L2₹40.6 L+₹3.8 L (10.2%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted | |
| 3 | L3₹41.5 L+₹4.7 L (12.8%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
18 May 2022, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
SPECIAL REPAIR TO GUEST ROOMS AT OFFICERS MESS AT AFSSR UNDER GE (AF) GURGAON
2022_MES_519026_1
CA NO GE/GUR-/NIT-02/2022-23
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹86,000
15 Jun 2022
20 Apr 2022
20 May 2022
20 Apr 2022
18 May 2022
4 May 2022
Amount
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitions etc complete all as specified and as directed
Demolition reinforced cement concrete in roofs, floors (other than ground floors), beams staircases, landing, chajjas, Shelves and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified.
Dismantling Floor, Paver Tiles, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), including removal of rubbish outside MoD land, complete all as specified and as directed.
Dismantling of Bricks laid dry (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer), complete all as specified and as directed.
Demolition of Mud Phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) disposing the rubbish to a distance exceeding 250 Mtr but not exceeding 500 Mtr away to low lying areas complete all as specified and directed.
M&L for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified and as directed.
M&L for Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed of size 6mm with Coarse Sand and Cement in the ratio 1:1:1 shall be applied and finish Even, complete all as specified and as directed.
M&L for preparing newly Rough Cast plastered surfaces of Walls and applying Two Coats of acrylic Weather Coat Exterior Paint with approved Tint over a coat of Primer (as per Manufacturer's instructions), complete all as specified and as directed.
M&L for Rendering (External) 15mm thick in Cement Mortar 1:4 on Brick Walls or on Concrete Surfaces, mixing WPC as per manufacturers instructions, Plastered Surfaces finished Fair and Even, complete all as specified and as directed. NOTE: WPC shall be Measured and Paid under appropriate Item. Area includes in this items upto 4 stories of building.
M&L for rendering 15 mm thick on brick work or concrete surfaces on walls in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces on ceiling/ struts in patches in CM 1:3. finishing even and smooth without using extra cement complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in copings, roof padding, staging of water tank, benching etc and similar nature of works mixed with water liquid proofing admixture as per manufacturer's instruction including finishing even and smooth using extra cement and rounded or chamfered on edges and necessary foamwork complete all as specified and directed by Engineer-in-Charge. Note :- (i) WPC shall be measured and paid separately. (ii) Rates include to carried out the work on roof slabof building & nothing extra shall be admissible on this account).
Supply only integral water proofing compound complete all as specified and as directed.
M&L for three coats of white wash on New plaster surface of ceiling including prepration of surface complete all as specified and as directed.
M&L for 2mm thick birla white putty and making the surface smooth etc complete all as specified and as directed.
M&L for preparing Old plastered surface of walls and applying two coat of oil emulsion distemper white or any tint etc complete all as specified and as directed.
M&L for preparation of New surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces including preparing old Decorated/Treated Plastered surfaces of Walls by Complete Removal of existing Treatment and by applying 2mm thick plaster of paris Wall Putty, cutting/ rubbing to obtained a Smooth Surface complete all as specified and as directed.
M & L for Finishing walls with textured interior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sq complete all as specified and as directed.
Taking down Chowkats or frames from the opening of size not exceeding 1.5 sqm each with shutters ( without taking off shutters from the frames) complete all as specified and as directed.
Taking down Chowkats or frames from the opening of size exceeding 1.5 Sqmtr but not exceeding 4 Sqmtr each with shutters ( without taking off shutters from the frames) complete all as specified and as directed.
Taking down Shutters of any description of size exceeding 1 sqm and not exceeding 2 sqm each complete all as specified and as directed.
S & F in repair Providing and fixing factory made UPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.Area not exceeding 2.00 sqm each. ((Note: The unit rate quoted by contractor includes cost of glass and all other connected accessories. Net opening will be measured for payment purpose.)
S & F in repair Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be include in the quoted lum sum). → Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S & F in repair Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be included in the lumpsum quoted by the contractor.
S&F 30mm thick flush shutter solid core construction with block board core and ply wood face panels, commercial type on both sides complete all as specified and as directed.
M&L for Polish Glazed Vitirified Ceramic Tiles 10mm thick (Square/Rectangular), Light shade Polished, area of each Tile exc. 0.42 Square Metre but not exc 1.0 Sqm as in Floors, etc. set and jointed in Neat Cement Slurry and pointed in White or Coloured Cement to match the Tiles, laid over and including 15mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate.
M&L for Polish Glazed Vitirified Ceramic Tiles 10mm thick (Square/Rectangular), Light shade, Polished, area of each Tile not exc. 0.36 Square Metre in Floors, etc. set and jointed in Neat Cement Slurry and pointed in White or Coloured Cement to match the Tiles, laid over and including 15mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate.
M&L for Polish Glazed Vitirified Ceramic Tiles 10mm thick (Square/ Rectangular) Light shade, Polished, area of each Tile not exc. 0.36 Square Metre in Vertical Surface i.e. Dado, Skirting,etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick rendering in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Mortar shall deem to be include in the Quoted Unit Rate.
M&L for Coloured Glazed Ceramic Tiles 300x450x7mm thick in Vertical Surface i.e. Dado, Skirting,etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick rendering in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Rendering Cement Mortar shall deem to be include in the Quoted Unit Rate.
M&L for Coloured Glazed Ceramic Tiles 300x900x10mm thick in Vertical Surface i.e. Dado, Skirting, etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick rendering in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Rendering Cement Mortar shall deem to be include in the Quoted Unit Rate.
M&L for non-skid tiles ceramic coloured tiles 7 to 8 mm thick of size 400mmx400 mm as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles including 15 mm thick screed bedding layers in CM (1:4) complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate.
M&L for 75 mm thick cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate in sub base complete all as specified and as directed.
M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in floor finishing complete all as specified and as directed.
M & L for broken brick bats as in foundation for Loose filling with aggregates of gauge 40 to 80mm complete all as specified and as directed.
M&L for granite (Black) stone slab 15-18mm thick machine cut and machine polised, in skirting, Kitchen platform /dado, in floor etc laid over cement screed jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding the edges half round and polishing including pinning in brick/concrete wall to hold & support the vertical surfaces to granite work including drilling to wall & including screed bed 15 mm thick in cement mortar 1:4 complete all as specified and as directed by Engineer-In- Charge.
M&L for RCC Pre-cast Cement Concrete 1:2:4 (12.5mm graded stone aggregate) as in Louvres and Jallies, 25mm thick (measured solid) with all mouldings including Reinforcement with 4.0mm dia Mild Steel Bars/ Wire and setting in Cement Morter 1:4 complete all as specified and as directed. NOTE : Cost of Mild Steel Bars/Wire as Reinforcement will deem to be included in the Quoted Unit Rate.
M&L for mild steel TMT bars 10 mm dia and over, cut to length and bent to shape required and binding with mild steel wire dia not less than 0.9 mm (annealed) complete all as specified complete all as specified and as directed.
M&L for reinforced Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in roofs, chajjas,Shelves, beams, lintels complete all as specified and directed.
M & L for Formwork to soffits of floor or roof beam, beam haunching, girders, lintels, cantilivers, shelvesincluding supports, overhang, etc. also splays between floor and beams, for rough finished surface of concrete etc. complete all as specified and directed.
Dismantling Structural Steel or Mild Steel Work of any description including Framed Truss, etc., complete all as specified and as directed.
Dismantling damaged/unserviceable Galvalume, Fibre Glass Reinforced Translucent Corrugated Sheeting,AC and Fiber Sheeting of any gauge and thickness, complete all as specified and as directed.
M&L for Steel Work in Tubular Trusses including Special shaped Washer etc. complete using ERW or Induction Butt Welded Tubes, confirming to IS-1161-1979 Grade-240, complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L for Fibre Glass Reinforced Translucent Corrugated Sheeting 2.0mm thick with 20 Cm Side Lap and 15 Cm End Lap, fixed with Coach Screw and Washer in Roof, Walls, etc., complete all as specified and as directed.
S&F Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC colour sheet inclusive of solvent cement and fixing at site including 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification complete all as specified and as directed.
S&F in repair Stainless Steel Curtain Rod 25mm dia/bore (as approved) including fixing stainless steel Bracket(shaped as approved) not less than 80mm long to wall with Screws/ secured with stainless steel side doom(as approved) fitted/tightened on Curtain Rod at both ends with screw including taking down old curtain rod of any description, complete all as specified and as directed.
S&F One Piece Euorpen Water Closet Concealed of size 790x360x650mm Snow White, Soft Close Seat Cover having Twin Flush Fittings and Making Good to Floor/ distrubed Surfaces and fixed-in-repairs, complete all as specified and as directed. MAKE : JAQUAR SLS-WHT-6851S (WC), or eqivalent in CERA/ HINDUSTAN SANITARYWARE/ PARRYWARE (as approved by GE) out of list of makes
S&F Vitreous China White Wash Down Water Closet Pan (Pedestal Pattern) with Trap and Fixing Bolts and Making Good to Floor/ distrubed surfaces and fixed-in-repairs, complete all as specified and as directed. MAKE : HINDUSTAN SANITARYWARE 21027/ JAQUAR CNS-WHT553SN/ PARRYWARE C-0252(S) or eqivalent in CERA (as approved by GE) out of list of makes
S&F in repair PVC Flushing Cistern 10 Litre capacity White, Low Level, Valveless, Syphonic Action type with Inlet, Ball Valve, Float and Handle, a pair of Cast Iron Brackets Erecting Stand duly painted including cutting and pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and fixed-in-repairs, complete all as specified and as directed.CAT PART NO CONCEALO 508179 of HINDWARE or equivalent as approved out of list of makesincluding, complete in all respect as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back) with Brass Chromium Plated Waste Fitting 32mm bore (dia) and PVC Waste Pipe 32mm bore (dia) including a Pair of Cast Iron Brackets Brackets Erecting Stand duly painted including cutting and pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and fixed-in-repairs, complete all as specified and as directed. CAT PART NO 10052 of HINDWARE or equivalent as approved out of list of makes.
S&F in repair Bib Tap 15mm bore (dia), Cast Copper alloy, Fancy type Chromium Plated with Crutch or Butterfly Handle, screwed down, screwed for Iron Pipe or for Brass Ferrule and Chromium Plated Wall Flange complete all as specified and as directed by Engineer-in-Charg. Cat Part No PRS-CHR 043 of Make : JAQUAR, or equivalent as approved by GEout of list of makes.
S&F Pillar Tap 15mm bore (dia), Cast Copper Alloy with Capstan Heads, Chromium Plated, screwed down high pressure, with Long screwed Shanks and Fly-nuts, screwed for Iron Pipe and fixing-in-repairs, complete all as specified and as directed. MAKE : JAQUAR CON-021KN / MARC MOR-1010 or equivalent in GEM (as approved by GE) out of list of makes.
S & F in repair central hole basin mixer chromium plated fancy type cast copper alloy with auto closing system Cat Part NO CON-CHR-169KNB of Make : JAQUAR or equivalent as approved out of list of makes screwed for iron pipe or for brass ferrule and fixed to 15mm bore pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stop Cock/ Angle Valve 15mm bore (dia), Cast Copper Alloy, Fancy type, Chromium Plated with long Shank and Cup (Concealed type), screwed down, high pressure and fixing-in-repairs, complete all as specified and as directed. with Cat Part No COT-CHR 23053 of Make : JAQUAR, or equivalent out of list of makes complete all as specified and directed by Engineer-in-Charge.
S & F Glass corner self chromium plated fancy type cast copper alloy with Cat Part No ACN-CHR-1173 of Make : JAQUAR, or equivalent as approved out of list of makes complete all as specified and directed by Engineer-in-Charge.
S & F double arm wall mounted mirror with Cat Part No ACN-CHR-1193N of Make : JAQUAR, or equivalent as approved out of list of makes complete all as specified and directed by Engineer-in-Charge.
S & F double coat hook with Cat Part No AQN-CHR-7761 of Make : JAQUAR, or equivalent as approved out of list of makes complete all as specified and directed by Engineer-in-Charge.
S & F glass self 600mm long with Cat Part No ACN-CHR-1171N of Make : JAQUAR, or equivalent as approved out of list of makes complete all as specified and directed by Engineer-in-Charge.
S & F paper holder with Cat Part No AHS-CHR-1553 of Make : JAQUAR, or equivalent as approved out of list of makes complete all as specified and directed by Engineer-in-Charge.
S & F soap dispenser with Cat Part No AKP-CHR-35735P1 of Make : JAQUAR, or equivalent as approved out of list of makes complete all as specified and directed by Engineer-in-Charge.
S & F soap dish holder with Cat Part No AQN-CHR-7731 of Make : JAQUAR, or equivalent as approved out of list of makes complete all as specified and directed by Engineer-in-Charge.
S & F towel rack with Cat Part No AHS-CHR-1581H of Make : JAQUAR, or equivalent as approved out of list of makes complete all as specified and directed by Engineer-in-Charge.
S & F towel ring with Cat Part No AQN-CHR-7721 of Make : JAQUAR, or equivalent as approved out of list of makes complete all as specified and directed by Engineer-in-Charge.
S & F towel rail 600mm long with Cat Part No AKP-CHR-35711PS of Make : JAQUAR, or equivalent as approved out of list of makes complete all as specified and directed by Engineer-in-Charge.
S & F alive maze over head shower with shower arms of Cat Part No OHS-CHR-85859M of Make : JAQUAR, or equivalent as approved out of list of makes complete all as specified and directed by Engineer-in-Charge.
S&F Wall Mixer 15mm bore (dia), Chromium Plated, Telephonic type with Flanges including Telephonic Shower Tube 1.50 Metre long with Hook and fixing-in-repairs, complete all as specified and as directed. Cat Part No KUP-CHR-35115P of Make : JAQUAR, or equivalent out of list of makes.
S&F Stop Cock 15mm bore (dia), Cast Copper Alloy, Fancy type, Chromium Plated with long Shank and Cup (Concealed type), screwed down, high pressure and fixing-in-repairs, complete all as specified and as directed. Cat Part No ALD-CHR-089CQT of Make : JAQUAR, or equivalent as approved out of list of makes, complete all as specified and directed by Engineer-in-Charge.
S&F PVC Connection Pipe 15mm size and 45 Cm in length with Adopter Nuts of PVC and fixed-in-repairs, complete all as specified and as directed. MAKE : PRAYAG CAT No. 324 / POLYTUFF or equivalent out of list of makes.
S&F Health Faucet with Wall Hook, Chromium Plated having 1.00 Metre long with PVC Hose Pipe and fixed in repairs, complete all as specified and as directed. MAKE : JAQUAR ALD-CHR-585 or equivalent in GEM/ MARC (as approved by GE) out of list of makes.
S&F in repair SS grating 100mm dia with or wihout waste hole of brass chromium plated fixed on floor/nahani trap with coment mortrar complete all as specified and as directed.
M&L for exterior grade, coloured glossy finish rubber pressed, cement concrete designer chequered tiles of size 40cm x 40cm x 25mm thick ( as approved by GE) set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc laid over including 15 mm thick cement screed bed in CM 1:6 . complete all as specifed and as directed.
M&L for exterior grade, coloured glossy finish ceramic designer endura tiles of size 30cm x 30cm x 8-10mm thick (as approved by GE) set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc laid over and including 15 mm thick screed bed in cm 1:6 complete all as specifed and as directed.
M&L for PCC (1:2:4) type B1, (using 20mm graded crushed stone aggregate) as in cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specifed and as directed.
M&L for preparation of new surface of any description and applying two coats of synthetic enamelled paint over a coat of red oxide primer on steel surface over 10cm width or girth complete all as specifed.
M&Lfor preparing old Treated/Painted Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed.
Taking up or down galvanised steel water tubing 15mm bore fixed to walls or laid under floors or in any other position along with required connections including cleaning for re-fixing or renewal from site etc complete all as specified and directed by Engineer-in-Charge.
Taking up or down galvanised steel water tubing 20mm bore fixed to walls or laid under floors or in any other position along with required connections including cleaning for re-fixing or renewal from site etc complete all as specified and directed by Engineer-in-Charge.
M & L for 15mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls concealed and or laid under floors etc complete all as specified and directed by Engineer-in-Charge.
M & L for 20mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls concealed and or laid under floors etc complete all as specified and directed by Engineer-in-Charge.
M&L for 15 mm thick plaster in CM (1:4) mixed with water proofing compound on roof slabs finished even and smooth without using extra cement after cleaning of roof surfaces with wire brushes complete all as specified and directed by Engr-in-Charge. Notes : WPC shall be measured and paid seperately.
M & L for applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm including cleaning surface complete as all specified and as directed.
M&L for water proofing treatment with polymeric water proofing membrane as under :- Supply and laying five layer prefabricated Atactic polypropylene Polymer (APP) modified membrane of 3mm thick membrane (Weight not less than 3 Kg/Sqm) reinforced with 160gsm polyster non woven fabric with two coat of water proofing paint with alumnium finish on top including overlapping as per manufacturers instruction. Note : APP membrane shall be laid on primed surface by Torch application method after allowing 24 hrs for Primer to dry. On Accesible roof where Brick tile is laid APP membrane shall not be painted.
M & L for Hydraulically pressed PCC tile plain of size 200x200x19/20mm machine made laid over & including cement mortar screed 15mm thick in CM 1:6 mixed with water proofing compound and jointed pointed in CM 1:3 mixed with 5% crude oil by weight of cement complete all as specified and directed by Engr-in-Charge.
M&L for Designing providing and fixing 3mm thick Aluminium Composite Panel Cladding over RCC/Brick surfaces either segmental/straight in plan wherever specified with extruded aluminium U sections, angle, cleats, weather silicon sealants, backer rods of required size stainless steel screws, rivets, brackets, drilling and fixing the cladding to either masonry or reinforced cement concrete including repairing of wall with plaster CM 1:4 where required to fix aluminium setion as the case may be manufacturer's specifications, complete the work in all respect including all necessary accessories. At all soffits aluminium cladding shall be bend 90 degree and joints at corner or edges will not be acceptable. On horizontal surface, the size of sheet should be maximum available of size complete all as per manufacturer's specifications and as directed.
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 Coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per sqm, top layer 15mm cement plaster WITH SILVER COLOUR CEMENT 1:1/2 : 2 ( 1 Silver Cement : 1/2 coarse sand : 2 Marble stone chipping 10mm nominal size) inpanels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the marble stone chippings complete all as specified the groove shall be 15mm wide and 15mm deep in the top layer of washed stone girt plaster as per approved pattern using wooden battens, nailed to the under layer including removal to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specification and direction of the Engineer-in-Charge. Note:- Area includes in this items upto 2 stories of building, necessary scaffolding and arrengments are deemed to be included in the lum sum rates.
M&L for applying designer Plaster of Paris (POP) false ceiling consisting of frame work made with 50 mm square MS tube of 18 Gauge thickness as main runner at 600 mm c/c both ways suspended/supported with MS flats 25x4 mm from existing RCC slab including providing and fixing expanded metal of size 5.25mmx1.25 mm thickness welded to main runner and applying POP (Plaster of Paris) to the expanded metal of thickness not less than 10 mm finished smooth to line and level and applying two coats of plastic emulsion paint design as approved by Engr-in-Charge with necessary support scaffolding etc as required and including applying a coat of red oxide zinc chromate primer over the MS frame work and also including dismantling of old existing false ceiling of any type complete all as specified and directed by Engr-in-Charge.
S&F Jet Spray with Connection Pipe 15mm bore (dia), Brass Chromium Plated and suitable for Wash Down Water Closet Pan (Pedestal Pattern) and fixed-in-repairs, complete all as specified and as directed. MAKE : GEM/ JAQUAR/ MARC (as approved by GE) out of list of makes.
Dismantling damaged/unserviceable GI Snap Grid Ceiling Frame Work with Ceiling Boards of any description, complete all as specified and as directed.
S&F GI Powder coated GI Snap Grid Frame Work of size 605x605mm as in False Ceiling with supported hanging of Mild Steel Rod of 'J' Bolt, complete all as specified and as directed.
M&L for 12 mm thick perforated particle board/ tiles for insulation and accoustic purposes, 60x60 cm in size,fixed with nails or with staple in ceiling/ timber frame complete all as specified.
Excavation in trenches, not exceeding 1.5 M wide, and not exceeding 1.5 M in depth for foundation etc and getting out in soft/loose soil complete all as specified and as directed.
Returning & filling of the excavated earth including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils. complete all as specified and directed.
Removing Excavated soils n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point. complete all as specified and directed.
S&F Aluminium Barrel Tower Bolt 150mm long (weight not less than 210 Gram), extruded section, complete all as specified and as directed.
S&F Aluminium alloy, anodized, Sliding Door Bolt 200mm long with Hasp Staple (Bolt type) and Fixing Clips of Sheet cast or extruded section and fixing Bolts and Sliding Bolts of extruded section and fixing, complete all as specified and as directed.
S&F Stainless Steel Butt Hinge of size 100mm (weight not less than 80 Gram), complete all as specified and as directed.
S&F Extruded Aluminium alloy Handle 150mm long (weight not less than 120 Gram), Fabricated type, anodised, complete all as specified and as directed.
S&F Door Closer Aluminium (Die Cast) Body, hydraulically regulated, Designation No. 3, Universal type, suitable for Door Shutters of 851mm to 1000mm in width and of weight between 61.00 to 80.00 Kilogram and fixed-in-repairs, complete all as specified and as directed.
S&F Sheet Glass 5.0mm thick, Tinted (as approved by GE) fixing to Aluminium door / Window including replacement of Rubber Packing and refixing Aluminium Beading, complete all as specified and as directed. NOTE : Cost of Rubber Packing shall deem to be include in the Quoted Unit Rate.
S&F rotational moulded polythene, triple layers, water storage tank 500 Ltr capacity, closed top, cylindrical, hoisted and fixed in position incl S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed incl Dismantling water tanks Exc 250 Ltr & not exceeding 500Ltr complete all as specified and directed by Engr-in-Charge.
S&F rotational moulded polythene, triple layers, water storage tank 1000 Ltr capacity, closed top, cylindrical, hoisted and fixed in position incl S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed incl Dismantling water tanks complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc all as specified as directed.
Taking down unserviceable main switches MCB DB’s incl MCB SP/SPN/TPN of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and asdirected.
Taking down carefully sub main wiring complete with conductor, cast conductor and PVC casing and coping and make good to the disturbed surfaces complete all as specified and asdirected.
M&L for point wiring complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed FRLS Grade cable 1100 volts grade confirming to IS: 694 for phase and neutral drawn in and including medium duty concealed PVC conduit confirming to ISI marked not less than 20mm including single core stranded copper conductor 1.5 Sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for the following :-
One light point controlled by one switch with cables 1.5 Sqmm size all as specified and directed.
One fan point/Exhaust fan controlled by one switch with cables 1.5 Sqmm size all as specified and directed.
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size all as specified and directed.
One 5 pin socket oulet 6 amps on same board including single core stranded copper conductor 1.5 sqmm PVC insulated and unsheathed cable drawn in same conduit as earth wire to the common earth and connecting to earth dolly all as specified.
One 3 pin socket outlet, 6 Amps, independent, with cables 1.5 sqmm of size all as specified and directed.
One 3/6 pin socket outlet, 16 Amps on independent boards with cables 2.5 Sqmm size complete all as specified and as directed.
S&F in repairs swicth 6 Amp, SP, 1 Way, 1 module cat part No 573400 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F in repairs Bell Push 6 Amp, SP, 1 Way, 1 module cat part No 573413 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F in repairs socket shuttered 6 Amp, 2/3 pin, universal Indian, 2 module cat part No 573470 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F in repairs socket 6/16 Amp,3 Pin Indian, 2 module cat part No 573471 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F swicth 20 Amp, SP, 1 Way, 1 module cat part No 573410 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F light dimmer 60 to 400 watt 2 Module Cat Part No 573462 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F in repairs flush mounting box 3 module cat Part No 689008 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F in repairs flush mounting box 8 Module Cat Part No 689042 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F in repairs flush mounting box 12 Module Cat Part No 689011 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F in repairs flush mounting box 1/2 Module Cat Part No 689007 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F in repairs white plate inner and outer 2 Module Cat Part No 575899 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F in repairs white plate inner and outer 3 Module Cat Part No 575960 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F in repairs white plate inner and outer 8 Module Cat Part No 575995 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F in repairs white plate inner and outer 12 Module Cat Part No 575997 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
S&F fan regulators 100 watt 1 Module Cat Part No 573416 Make: Legrand or equivallent model in L&T or out of makes specified in list of makes.
Supply and fix in repairs ceiling roses, 3 terminal PVC/Polycarbonate, isolated body all as specified and directed at site.
Supply and fixing in repairs calling bell ding dong, AC 230 volts, single pole complete all as specified and directed at site.
Supply and fix in replacement of 20 watt (4ft long) decorative box type fitting with blue coloured end caps for LED tube etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to terminal block and testing complete all as specified and directed at site.
Supply and fix in replacement of 12 watt 2 ft decorative box type fitting with coloured end caps for LED tube etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to terminal block and testing complete all as specified and directed at site.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed.
S&F water heater (Geyser) 25 ltr capacity vertical type Ivory in colour Cat Part No: GHWAMGSI/3025, rated power 2 KW. Make: Havells or out of makes specified in list of makes.
S&F Ventil air DB Neo 300mm sweep, 70 watt, 1400 RPM, air delivery 1785 m³/n double ball bearing, heavy duty motor with protective steel bird guard robust construction. Make : Havells or out of makes specified in list of makes.
Supply and fix in replacement MCB, DB , SPN 8 way suitable for single phase 240 volts with 200 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCB's single/double pole complete all as specified and directed at site.
Supply and fixing in replacement of MCB signle pole 5-32 Amps 230 volts 'C' series complete all as specified and as directed.
Supply and fixing in replacement of MCB single pole and neutral 40 /63 Amps 230 volts 'C' series complete all as specified and as directed at site.
Supply & fix in replacement of SPN enclosure with two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified and directed by Engineer-in-Charge. Make:- Model No 607841 of Make Legrand or equivalent in Siemens/Hagger/L&T.
M&L for point wiring complete with stranded copper conductor 4 Sqmm size (Nominal area) PVC insulated unsheathed FRLS cable 1100 volts grade confirming to IS: 694 drawn in and including medium grade concealed PVC conduit confirming to ISI marked not less than 25mm dia including single core stranded copper conductor 2.5 Sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for an independent board. (for geysers & A.C point)
S&F submain wiring with unsheathed multi-stranded FRLS Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
S&F vertical type load line distribution board, double door, 4 way AC, 3 phase 415 volts, TPN bus bar 200 Amps rating and earth bus and din rail including 01 No. MCCB 3 pole 415 volts, 50 Hz, 100Amps 10 KA breaking capacity as incomer complete all as specified and as directed.
S&F MCCB 4 pole 415 volts, 50 Hz, 100Amps 16 KA breaking capacity as incomer complete all as specified and as directed.
Supply, laying and testing in replacement of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 50 Sq mm. complete all as specified and as directed.
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
M&L for sub class ‘B’ bricks old size laid flat dry in trenches over cable, across the direction of cable complete all as specified & directed.
S&F recessed mounted beautiful soft light LED down light with PDC aluminum body decorative downlight UFO round 20 watt 6500K cat Part No LD00125007. Make: - Polycab or equivalent model in Bajaj/ Havells
SHAKSHI ENTERPRISES
P R Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .