Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 314 SADAR MEERUT CANTT TILAK PARK MEERUT MEERUT UTTAR PRADESH 250001 | MEERUT | UTTAR PRADESH | 250001 | Accepted-Technical Techno commercially responsive bidder |
| 2 | Accepted-Technical | Accepted-Technical Techno commercially responsive bidder |
| 3 | Accepted-Technical 6 SHASTRI MARKET JALANDHAR JALANDHAR PUNJAB 144001 | JALANDHAR | PUNJAB | 144001 | Accepted-Technical Techno commercially responsive bidder |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-As per calsue 13.2 of Tender Document only recognized startup as per DIPP are exempted from furnshing the bid security /EMD. Bidder has not submitted valid startup certificate to avail exemption for EMD. Therefore bid can not be considered. |
| 5 | Not Admitted-Fee/PreQual/Technical VILLAGE SHANNA KISHTWAR | KISHTWAR | JAMMU AND KASHMIR | 182132 | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
Tender Value
₹59.4 L
EMD Value
₹1.2 L
Closing Date
6 Mar 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM (Contract), Contract Complex, DPS, Kishtwar
DGM (Contract), Contract Complex, Dulhasti Power Station, Kishtwar (J and K) PIN-182206
Repair work of SFT gates no 1 and 2 with replacement of steel liners sill beams and rubber seals of gates at Dam of DPS Kishtwar
2026_NHPC_897181_1
NH/DPS/CONT/NIT-258/2025/E 160252 dated 05.02.2026
Open Tender
Civil Works
Works
90 days
Dul Dam-Dulhasti Power Station Kishtwar
Please refer tender document
2 documents required · 2 mandatory
₹1,180
NHPC Limited
₹1.2 L
Yes
11 Apr 2026
5 Feb 2026
10 Mar 2026
5 Feb 2026
6 Mar 2026
5 Feb 2026
5 Feb 2026 - 12 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dewatering/pumping out of water caused by spring, tidal, river seapage, broken water mains or drains and like. (Dewatering in SFT including all (motor, pump,starter, hose pipe,operator etc.) with material to be used like sand bag, polypropylene sheet, M.S. plate with welding, welding machine, alogwith all other necessary arrangements to be done for taking water out for proper working at site.) | 2,203.2 | KL | - | - |
| 2 | Dismantling steel work (linner , Sill beam etc approx 2900 mmX 1850mmX20X2 , 2900mm X 1206 mmX 25 mm) in built up sections in angles,tees,flats and channels including all plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. | 6,916.91 | kg | - | - |
| 3 | Chipping of old concrete for making correct grade and profile upto required depth using suitable equipment such as Jack Hammer Chipper including removal of unsound concrete surface as per technical specification and disposing the excavated material away from work site including all lead and lifts as per direction of Engineer In Charge | 1.46 | Cum | - | - |
| 4 | Surface preparation of old concrete by way of running wire brush and chiselling for laying of concrete as per technical specifications including all stages and scafolding etc complete finished item with all lead and lift | 31.3 | Sqm | - | - |
| 5 | Drilling of 32 mm dia holes for fixing of 25 mm dia Anchors and 500mm deep in chipped old concrete by way of suitable equipment as per Technical specification. | 178 | M | - | - |
| 6 | Providing and Fixing of 25 mm dia,0.50 m length of Chemical Anchor as per drawing,Specification and as per direction of Engineer-in-charge. | 89 | Nos. | - | - |
| 7 | Epoxy resin system of (SIKA/FOSROC/BASF/PIDILITE/MC/HENKEL) make filling in drilling holes (chemical Anchors) for anchoring as per technical specifications including the cost of all materials carriage, staging scaffholding and labour etc. complete finished item. | 22.61 | kg | - | - |
| 8 | Supply and apply an epoxy resin based bond coat in between old and new concrete/steel through Grout holes a coat of even and smooth (consumption of material may be more due to uneven surface/undulation)(SIKA/FOSROC/BASF/PIDILITE/ MC/HENKEL) as per technical specifications including cost of all materials, carriage and labour etc. complete finished item. | 28.42 | Sqm | - | - |
| 9 | Providing, fabrication & fixing of bottom steel liner of 2700 MM long(approx.) x 1200MM x 25MM thick Steel plate of grade E28.3 for SFT gates# 1&2 as per drawing and specifications complete and joining of the same with steel liner & joining of steel liner with new sill beam and as per drawing and specifications.
Providing & fixing of side steel liner of 2600 MM long(approx.) x 1850MM (approx.) x 20MM thick Steel plate ofgrade E28.3 for SFT gates# 1&2 as per drawing and specifications complete. and joining of the same with steel liner & joining of steel liner with new sill beam and as per drawing and specifications. | 8,535.64 | kg | - | - |
| 10 | Providing and laying high performance concrete M65/A20 as per technical specifications,proper compaction ,curing including the cost of all materials,carriage staging ,scafolding and labour etc.with all leads and lifts complete finished item.for SFT 01& 02 | 9.38 | Cum | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 9.60 MB
FinalTenderDocument.pdf
Tender Documents • 9.58 MB
BOQ_943048.xls
BOQ • 0.36 MB
Corrigendum1.pdf
PDF • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .