Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L1 | Accepted-AOC Accepted lowest rate quoted | |
| 2 | L2₹15.9 L+₹23,505 (1.50%)Rejected-Finance | L2 | Rejected-Finance Rejected due to highest bid | |
| 3 | L3₹16.1 L+₹43,230 (2.76%)Rejected-Finance H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L3 | Rejected-Finance Rejected due to highest bid | |
| 4 | L4₹17.3 L+₹1.6 L (10.4%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L4 | Rejected-Finance Rejected due to highest bid | |
| 5 | L5₹17.6 L+₹2.0 L (12.6%)Rejected-Finance | L5 | Rejected-Finance Rejected due to highest bid |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Gurgaon
GE (AF) Gurgaon
REPAIR AND MAINT OF INTERNAL ELECTRIC SUPPLY SYSTEM WITH FANS GEYSER AND ALLIED WORKS AT AF STN ARJANGARH UNDER GE AF GURGAON
2023_MES_601524_1
GE/GUR-/NIT-04/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹60,000
18 Jul 2023
6 Jun 2023
6 Jul 2023
6 Jun 2023
4 Jul 2023
20 Jun 2023
Amount
Taking down ceiling fan of any make 1200/1400 mm sweep from site for repairing after dismantling its blades complete all as specified and as directed.
Taking down Exhaust fans/wall mounting fans of any make and any size from site for repairing after dismantling its legs and blades complete all as specified and as directed.
M&L for Repairing of ceiling fan of any make, 1200 mm/1400 mm sweep dismantling its parts cleaning properly, rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing replacing petti items such as split pins, assembling and testing after fixing of fan blades, refixing at site and connecting complete all as specified and as directed.
M&L for Repairing of Exhaust fan of any make 300/250 mm sweep dismantling its parts cleaning properly rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing replacing petti items such as split pins, cleaning of fan body and its blade by cleaning agent assembling and testing after fixing of fan blades, refixing at site and connecting complete all as specified and as directed.
M&L for Repairing of Exhaust fan of any make 380 mm sweep dismantling its parts cleaning properly rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing replacing petti items such as split pins, cleaning of fan body and its blade by cleaning agent assembling and testing after fixing of fan blades, refixing at site and connecting complete all as specified and as directed.
M&L for Repairing of exhaust fan of any make 450 mm sweep dismantling its parts, cleaning properly, rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing, replacing petti items such as split pins, cleaning of fan body and its blade by cleaning agent assembling and testing after fixing of fan blades refixing at site and connecting complete all as specified and as directed.
M&L for Overhauling of ceiling fan any size and make, dismantling parts, properly cleaning/removing old existing grease oil and removing old paint from blades and body including down rods complete. Applying new oil grease, varnishing of winding, cleaning dust, rust and applying one coat white enamel paint over a coat of steel primer, assembling and refixing at site complete all as specified and as directed.
M&L for Overhauling of Exhaust fans any size and make, dismantling parts properly cleaning/removing old existing grease oil and removing old paint from blades. Applying new oil grease, varnishing of winding, cleaning dust, rust & applying one coat grey enamel paint, assembling and refixing at site complete all as specified and as directed. Note for item 3 to 7 :- (a) Worn out/damaged parts such as canopy, rubber bush, capacitors, and Gun metal bushes, ball bearing shall be measured and paid separately as supply only under relevant items of Sch 'A'. (b) The rate quoted is deemed to be included for labour.
M&L for Repairing of cabin/padestal/wall mounted fan of any make 380 to 400 mm sweep dismantling its parts, cleaning properly, rewinding with super enameled copper wire suitable gauge, varnishing, oiling and greasing, replacing petti items such as split pins, cleaning of fan body and its balde by cleaning agent painting the blades, body and base with one coat existing colour systhetic enamel paint over a coat of steel primer and assembling, testing after fixing of fan blade refixing at site and connecting complete all as specified and as directed.
Supply only ceiling fan canopy suitable for 15 mm dia rod with fixing nuts and bolts complete all as specified and as directed.
Supply only gun metal bush suitable for 1200mm/1400 mm sweep ceiling fan of any make complete all as specified and as directed..
Supply only gun metal bush for exhaust fan of any size/make/sweep complete all as specified and as directed.
Supply only ball bearing of size 6201complete all as specified and as directed. (Make : NBC/SKF/TATA)
Supply only ball bearing of size 6202 complete all as specified and as directed. (Make : NBC/SKF/TATA)
Supply only ball bearing of size 6203 complete all as specified and as directed. (Make : NBC/SKF/TATA)
Supply only ball bearing of size 6204 complete all as specified and as directed. (Make : NBC/SKF/TATA)
Supply only capacitor 3.15 mfd complete all as specified and as directed. (Make : Asian/Epcos/Usha)
15. Supply only capacitor 4 mfd complete all as specified and as directed.. (Make : Asian/Epcos/Usha)
Supply and fix in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd.
Supply and fix exhaust fan shaft suitable for 250/300/380/450 mm sweep complete all as specified and as directed.
M&L for preparing surfaces by removing/cleaning dust & depositeld materials and applying one coat of white enamelled paint to fan blades, body and down rod of ceiling fans at existing position without removing from site complete all as specified and as directed.
Supply and fix in repairs ceiling fan clamps of heavy duty as per sample including nut, bolts, spring washers, cross pin and rubber reel etc complete all as specified and as directed.
Supply and fixing fan blade of 1200 /1400 mm sweep to match with the existing fan complete all as specified and directed by Engr-in-charge.
Supply and fix MS seamless steel tube down rod for hanging the fan including cutting the false ceiling and making good the false ceiling after fixing of fan down rod complete all as specified and directed.
Supply and fix exhaust fan louvers/shutter metallic suitable for 300/250 mm sweep complete all as specified and directed.
Supply and fix exhaust fan louvers/shutter metallic suitable for 380 mm sweep complete all as specified and directed.
Supply and fix exhaust fan louvers/shutter metallic suitable for 450 mm sweep complete all as specified and directed.
Supply and fix in replacement ceiling fan 1200 mm sweep complete with down rod canopy and blades of size 1200 mm sweep,Energy efficient, 5 star rated make Havells. / crompton / Bajaj ( Old fans will be deposited to MES authorities)
Supply and fix in replacement Exhaust fan 300 mm sweep complete with brackets frame and blades, metalic body heavy duty with louvers suitable for 240V 50 Hz supply , make Havells. / crompton / Bajaj ( Old fans will be deposited to MES authorities)
Supply and fix in replacement Exhaust fan 380 mm sweep complete with brackets frame and blades, metalic body heavy duty with louvers suitable for 240V 50 Hz supply , make Havells. / crompton / Bajaj ( Old fans will be deposited to MES authorities)
Supply and fix in replacement Exhaust fan 450 mm sweep complete with brackets frame and blades, metalic body heavy duty with louvers suitable for 240V 50 Hz supply , make Havells. / crompton / Bajaj ( Old fans will be deposited to MES authorities)
Supply and fix ventilating exhaust fan single phase, plastic body 200 mm sweep, complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastener as approved by Engr-in-charge complete all as specified and directed.
M & L for opening the bus bar and rear/front panel of LT Panel board (01 Nos incoming and upto 15 Nos outgoing), disconnecting the cables from the busbars, replacement of suitable size of aluminium lugs of various size (25 sq mm to 300 sq mm) through hydraulic crimping method, replacement of burnt out nuts/bolts, replacement of cable glands, replacement of internal wiring, replacement of partially burnt out bus bar (if required) taking down carefully the copper/aluminium bus bar as required at site, scrapping the bus bar by emery paper for removing the silt/carbon, replacement of PVC insulation tape (RYB) and assembling the bus bar, LT Panel board complete for testing complete all as specified and directed.
All as per item No. 33 above but of (01 No incoming and upto 8 Nos outgoing).
All as per item No. 33 above but of (01 Nos incoming and upto 06 Nos outgoing).
All as per item No. 33 above but of (01 Nos incoming and upto 04 Nos outgoing).
M & L for scrapping the old painted surfaces and spray painting of HT/LT panel board of size upto 6 m x 2.5m x 1 m with two coats of synthetic enamelled paint of approved colour complete with all fittings etc all as specified and directed by Engineer-in-charge. (Note rate quoted by the contractor deemed to be included the writing of outgoing and incoming feeder etc).
All as per item No. 37 above but of size 3 m x 2 m x 1 m
All as per item No. 37 above but of size 2 m x 2 m x 0.75 m
S&F in replacement of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser including all accessaries all as specified and directed. Make:- Crompton/Bajaj/Wipro
S&F in replacement of enviroment friendly indoor decorative 10 Watt LED mirror light polycarbonate Batten with opal diffuser including all accessaries all as specified and directed. Make : Crompton/Bajaj/Wipro.
S&F in replacement metal flush box 3 module all as specified and directed.
S&F in replacement metal flush box 6 module all as specified and directed.
S&F in replacement metal flush box 8 module all as specified and directed.
S&F in replacement metal flush box 12 module all as specified and directed.
S&F in replacement for white cover plate with frame, 1/2 module all as specified and directed.
S&F in replacement for white cover plate with frame, 3 module all as specified and directed.
S&F in replacement for white cover plate with frame, 6 module all as specified and directed.
S&F in replacement for white cover plate with frame, 8 module all as specified and directed.
S&F in replacement for white cover plate with frame, 12 module all as specified and directed.
S&F in replacement enviroment friendly recess/pendent mounting LED flat panel 2'x2' fabricated CRCA sheet steel housing cool white with high efficient LEDs & glare free opal diffuser (34 W) PF>0.95 driver life >25000 Hours, operating range 140v to 280 V including all accessaries all as specified and as directed. Wipro/Crompton/Bajaj
Supply and fixing in replacement microprocessor based three phase electronic tamper proof energy meter of rating 10 to 40 Amps, AC 415 Volts, 50 Hz covered with toughened glass cover with optical comunication port confirming to IS 13779 complete all as specified and as directed. (Old meter to be taken on charge by MES).
Supply and fixing in replacement microprocessor based single phase electronic tamper proof energy meter of rating 10 to 60 Amps, AC 240 Volts, 50 Hz covered with toughened glass cover with optical comunication port confirming to IS 13779 complete all as specified and as directed. (Old meter to be taken on charge by MES).
S&F in repair fluorescent tube light fitting flameproof type FLP - WP of T5 1 X 28 watt including integral reflector made of alluminium alloy LM6 with electronic ballast , bipin holders , connector block etc and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor with suitable size including 28 watt rod and all necessary fixing accessories complete all as specified and as directed.
S&F in repair switch flame proof rotary type with terminal box in LM6 , 16 amps SINGLE POLE 250 volts and all necessary fixing accessories complete all as specified and as directed.
Supply and fixing in repair LED post top 40/45 watts complete with suitable size of GI pipe suitable size of required length duly grouted in existing locations including , PVC copper wire 1.5 sq mm 3 core of required lenght (upto 3 mtrs) complete all as specified and as directed. Cat No. LLD0001542 of make : HALONIX or Cat No. LPTO-40-CDL-M of Make Crompton or equivalent in Bajaj.
Supply and fixing in repair LED bollard fitting 10w complete with suitable size of nuts/bolts for fixing arrangement and provision of suitable size PCC foundation for fixing of bollard fitting etc complete all as specified and as direction by Engr-in-charge. Cat No. LBLSN-10-CDL of Make : Crompton or equivalent in Bajaj or Havells.
M&L for supply and fix in repair heavy duty Contractor for three phase capacitors including necessary connections complete all as specified and as directed for the following capacity
(a) 3 pole power contactor type MNX-110.
(b) 3 pole power contactor type MNX-70.
(c) 3 pole power contactor type MNX-32.
(d) 3 pole power contactor type MNX-18.
Supply and install capacitor metalized poly propylene ultra heavy duty (LTXL) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15%. Make Shall be : EPCOS/L&T/Havells/Siemens
(a)25 KVAr
(b)20 KVAr
(c)10 KVAr
(d) 5 KVAr
S & F in repair sub main wiring for circuit of size 6 sq mm 2 runs (FRLS) alongwith earth wire of 4 sq mm single run of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in existing PVC conduit complete all as specified and directed by Engr-in-Charge.
S & F in repair sub main wiring for circuit of size 4 sq mm 2 runs (FRLS) alongwith earth wire of 2.5 sq mm single run of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in existing PVC conduit complete all as specified and directed by Engr-in-Charge.
S&F in replacement of single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 10-32 complete all as specified and as directed.
Fabricate, Supply, install, testing and commissioning of CPRI approved outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 2 mm thick CRCA sheet (Make -Tata/ sail) ( load bearing members 2 mm thick and non load bearing members such as doors partitions etc of thick ness 1.6 mm thick ), with gland plates at bottom with suitable Brass chromium plated glands, with cadmium plated high tensile nut and bolts washers, suitable barrel copper lugs for cable terminations complete, with locking arrangements complete ,sheets bend, folded, cut with CNC machine for the accuracy of diamensions +/-0.5%, duly powder coated with siemens grey colour after chemical trteatment, with suitable ventilation fan at the top ,including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars MCCB's with suitable size copper bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following. (FOR HQ)
(a) Bus bar Aluminum - 250 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves. .
(b) MCCB four pole 440 V, 125-160 Amp,36 KA , adjustable thermal and magnetic release - 01 No, L&T Cat No : CM9210800M1OG or equivalent out of makes specified in list of makes.
(c) MCCB four pole, 43-63 Amps 36 KA, with thermal and magnetic setting - 01 No L&T Cat No : DZ1F0063DXC1A or equivalent out of makes specified in list of makes.
(d) MCB TPN, 63 Amps, 10 KA, 'C' Series-03 Nos
(e) MCB SPN 40 Amps 'C' series-04 Nos
(h) ON/OFF LED indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 1Set of three
Fabricate, Supply, install, testing and commissioning in repair of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following Make of MCCB's shall be L&T/Legrand/Havells
(a) Bus bar Aluminium - 400 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves.
(b) MCCB 250 Amps 4 pole 36 KA, with adjustable thermal magnetic range as in coming - 01 No.
(c) MCCB 63 Amps 3 pole 16 KA with adjustable thermal setting as out going- 06 Nos.
(e) MCB SP 63 Amps, 10 KA, 'B' Series- 12 Nos
(f) Digital multifuctional meter (Make : L&T), 4410 Series, Cat No. WL441010OOOO
(g) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 01 Set
Supply, fixing and testing under voltage relay 415 Volts suitable AMF panel of DG set of any type any capacity complete all as specified and as directed.
Supply, fixing and testing on delay timer, 230 Volts, AC suitable AMF panel of DG set of any type any capacity complete all as specified and as directed.
Supply, fixing and testing engine starting relay 12V/24V, DC Supply suitable AMF panel of DG set of any type any capacity complete all as specified and as directed.
Supply, fixing and testing analog clock timer suitable fixing in AMF panel of DG set of any type any capacity complete all as specified and as directed.
Supply, fixing and testing battery charger 12 Volts suitable for fixing in AMF panel of DG set of any type any capacity complete all as specified and as directed.
Supply, fixing and testing battery charger 24 Volts suitable for fixing in AMF panel of DG set of any type any capacity complete all as specified and as directed.
Supply, fixing and testing Automatic voltage regulator for DG set of any capaicty and any make to match with the existing AC Input 415 Volts AC and DC output 100 V DC complete all as specified and as directed.
Supply and fixing solonoid magnetic switch suitable for 100 KVA DG set complete with wiring complete all as specified and as directed.
Supply and fixing tamper proof three phase electronic CT meter 10 to 60 Amps complete with suitable size of CT 100/5 Amps and to be housed in weather proof PVC box of suitable size complete with connection and all as specified and as directed. (Old meter to be taken on charge by MES).
M&L for rewinding of self startor with super enamelled copper wire of suitable guage of DG set of capacity 125 KVA complete all as specified and as directed.
M&L for rewinding of self startor with super enamelled copper wire of suitable guage of DG set of capacity 100 KVA complete all as specified and as directed.
M&L for rewinding of self startor with super enamelled copper wire of suitable guage of DG set of capacity 20 KVA complete all as specified and as directed.
Supply and fixing street light brackets made out of GI tubing light grade, 40 mm bore 1200 mm long bent to sahpe at 120 degree, fixed on pole by providing MS clamp made up to flat iron 50 x 6 mm including nuts and washer of suitable size, fixed in repairs complete all as specified and as directed.
S & F pole box for street light dust and vermin proof make Sintex model GSJB 3020 complete with aluminum bus bar 04 nos. of capacity 200 amps on epoxy insulators incl one MCB SP C series 06 amps 10 KA capacity for Security light connection including suitable clamps & suitable size brass chrome plated glands-02 nos at bottom for cable entry and exit complete all as specified and as directed.
Supply and fix in replacement double door TPN DBs 4 way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site required complete all as specified and as directed .
S & F in replacement with MCB TPN 32 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed .
S & F in replacement with MCB TPN 50 to 63 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed .
Supply and fixing in repair TPN DB's 8 way vertical type 415 V, double door suitable for housing of 125 Amps MCCB as main incoming complete all as specified and as directed.
All as per item No. 82 above but of 4 way and suitable for housing of 100 A/63 A MCCB as main incoming complete all as specified and as directed.
S & F MCCB 125 Amps capacity, 4 pole, 25 KA, fixed thermal and magnetic release complete with extended terminals to be fixed in 8 way TPN DB complete all as specified and as directed.
All as per item No.84 above but capacity 63 Amps, fixed thermal and magnetic release, 3 Pole, 25 KA suitable to be fixed in 4 way TPN DB complete all as specified and as directed.
Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
M&L for earthing complete withGI plate electrodes 600x600x6.3mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below ground level connected to GI strip 25x 4 mm as earthing lead fixed by means of nut bolt washer of brass as shown in electrical plate No.3 of SSR Pt-I 2009 including necessary excavation and earth work in any strata, GI pipe 20mm dia light grade for watering , and 40 mm light grade as protrection to earth wire upto 7.5 mtr ,charcoal & salt etc and PCC chamber in PCC 1:3:6 type C1 covered with 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS bar @ 75mm C/C both ways cover, funnel & wire mesh including making of test point complete all as specified and as directed including testing.
M&L for earthing complete withGI plate electrodes 600x600x6.3mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below ground level connected to G I wire 4 mm dia as earthing lead fixed by means of nut bolt washer of brass as shown in electrical plate No.3 of SSR Pt-I 2009 including necessary excavation and earth work in any strata, GI pipe 20mm dia light grade for watering , and 15 mm light grade as protrection to earth wire upto 7.5 mtr ,charcoal & salt etc and PCC chamber in PCC 1:3:6 type C1 covered with 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS bar @ 75mm C/C both ways cover, funnel & wire mesh including making of test point all as specified testing on complete.
M & L for replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-
One light / fan point controlled by one way switch
One 5 Amp socket outlet on independent board.
One 5 Amp socket outlet on same board.
One bell/buzzer point controlled by one bell push
One light point controlled by two 2-way switch
All as per above item No-89 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
M&L for replacement of point wiring in casing caping/PVC conduit (not less 20 mm) on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including PVC conduit , with mild steel terminal boxes (not less than 1.6 mm thick ) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :-
One light / fan point controlled by one way switch
One 5 Amp socket outlet on independent board.
One 5 Amp socket outlet on same board.
One bell/buzzer point controlled by one bell push
One light point controlled by two 2-way switch
All as per above item No 91 here in befor but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
M & L for replacement of point wiring in existing conduit (PVC/Steel) surface / concealed including existing MS Terminal boxes with 1.5 sqmm FRLS PVC insulated multi stranded copper conductor cable single core 1100 volts grade and one run of 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire and laminated sheet cover 3 mm thick on terminal box duly fixed including taking out old u/s wire of any type and size complete all as specified and as directed for the followings :-
One light / fan point controlled by one way switch
One 5 Amp socket outlet on independent board.
One 5 Amp socket outlet on same board.
One bell/buzzer point controlled by one bell push
All as per above item No 93 but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant ( FRLS ) cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
S&F in replacement switch piano type 5 amp one way ISI Marked complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement switch piano type15 Amps one way ISI Marked complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement socket outlet 3 pin 5 Amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement socket outlet 2-in-1, 3 pin 5 amp and 15 amps complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement switch 6 amps modular type one one way complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement switch 16 amps modular type one one way complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement electronic fan regulator Step type complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement bell push flush type 5 amp one way ISI Marked complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement modular type bell push 6 amp one module ISI Marked complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement Bell, DING DONG AC 230 Volts single pole type complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement of Lamp holder bakalite type with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed by Engineer-in-Charge.
S & F plasic body air fan / ventilator with louver 250mm sweep and grouting with nut , bolts & Fastenar on the wall and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and as directed by Engr-In - Charge. (Old fan to be taken on charge by MES).
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 4 core complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 110 above but Size 25 Sqmm X 4 core
All as per item No. 110 above but Size 95 Sqmm X 3.5 core
All as per item No. 110 above but Size 240 Sqmm X3.5 core
All as per item No. 110 above but size 10 sq mm 2 core
Supply and fix ON load four pole changeover switch with front handle operated of 4 pole 415 volt 50 Hz 400 amps in open execution to be fixed in existing panel with suitable size nut/bolts and complete all as directed.
M&L in repair/replacement for LT line PVC Spacers complete all as specified and as directed by Engineer-in-Charge for the following sizes :-
(a) Spacer for two wire
(b) Spacer for three wire
(c) Spacer for four wire
(d) Spacer for five wire
Supply & Fixing in repair including making connection testing and commissioning of new MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and as directed by Engineer-in-Charge. Note: The make of MCCB shall be L &T , GE , Havells, Strandard, crompton, C & S or any other make as per the make in the existing plannel board or exactly suitable to the existing frame size. In case only one particular make is procuring by the bidder necceasry alteration required to fix the same at no extra cost shall be done by the bidder .
All as per item No 117 above but MCCB TP 400 Amps, 415 Volts, 36 KA, 50 Hz complete with extended terminals and PVC spreader complete all as specified and directed.
All as per item No 117 above but MCCB TP 125 Amps, 415 Volts, 36 KA, 50 Hz complete with extended terminals and PVC spreader complete all as specified and as directed by Engineer-in-Charge.
All as per itemNo 117 above but MCCB TP 250 Amps, 415 Volts, 36 KA, 50 Hz complete with extended terminals and PVC spreader complete all as specified and as directed by Engineer-in-Charge.
Fabricate, Supply, install, testing and commissioning in repair of Feeder pillar box (Out door type) of size 50 cm x 50 cm x 25 cm (L x H X B) suitable for 440 Volt, 3 phase & Neutral , 50Hz supply, floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet with gland plates at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including with suitable size aluminium bus bars 200 Amps 04 Nos in its full width (35 cm length) to be fixed on suitable size of insulators. The bus bar having 06 Nos of holes including provision of suitable size of nuts and botls of all four bus bars, the feeder pillar box shall be floor mouted with provision of four nos of legs made out out 50 x 50 x 5 mm MS angle not less than 40 cm and shall be grouted under PCC 1:2:4 complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing RGB flood light 50 watts IP 65 with colour changing remote complete all as specified and asdirected. Make : Glitz or its equivalent out of makes specified in list of makes.
Supply and fixing HRC fuses (DIN type) 160 Amps single pole complete all as specified and as directed.
Supply and fixing metal clad plug and socket AC plug 20 Amps 2 Pole + E, 230 Volts AC complete all as specified and as directed.
Supply and fixing AC female socket 20 A, 2 Pole + E, 230 volts AC complete all as specified and as directed.
Supply and fixing 6 A 3 Pin plug 230 Volts AC complete all as specified and as directed.
Supply and fixing 16 A 3 Pin Plug 230 Volts AC complete all as specified and as directed.
Supply and replacement of maintanance free unserviceable battery 12 V, 150 AH with initial charging and testing complete all as specified and as directed. Make: Amaron/Exide/Microtek.
Excavation of soft/loose soil in trenches not exc 1.5 meter wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in any type of soil and getting out complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and as directed by Engineer-in-Charge.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and as directed by Engineer-in-Charge. (Punned thickness shall be paid).
M & L for Old size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and as directed by Engineer-in-Charge.
M&L for Disconnecting and taking down of Geysers (water heater) of capacity 25/ 50 Ltrs horizontal/vertical of any make/model from existing position and dismantling of parts i.e.bottom plate, Top cover, water assembly thernmostat, heating elements, inner tank ,glass wool,Pressure release, inlet and outlet valves etc.complete and reassembling and refixing in same position after descaling desludging and cleaning with suitable cleaning agent and materials and washing with fresh water and repair and replacment of defective/unserviceable components complete all as specified and as directed by Engineer-in-Charge. Note: The rate quoted shall include the minors repairs and replacment of minor parts i.e. screw nuts, bolts washers and patch work etc .However the major components incoperated herein after shall be paid under respective items.
S&F in repair of required qty thermowool/PUF insulation as existing for Geysers of 50 Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
S&F in repair of required qty thermowool/PUF insulation as existing for Geysers of 25 Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
S&F in repair of water GEYSER ( syphon) assembly with rubber gaskit suitable for 50 Ltrs Geysers all as per exisiting shape and size complete all as specified and as directed
S&F in repair of water GEYSER ( syphon) assembly with rubber gaskit suitable for 25 Ltrs Geysers all as per exisiting shape and size complete all as specified and as directed
S&F in replacement of inner stainless steel container not less than 0.7 mm thick for 50 Ltrs Geysers complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of inner stainless steel container not less than 0.7 mm thick for 25 Ltrs Geysers complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of outer cover duly spray painted as per existing to geyser of 50 Ltr capacity complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of outer cover duly spray painted as per existing to geyser of 25 Ltr capacity complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of indicators red/green colour as per existing size and type complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of heating element triangle/cup type of 2 KW, 240 V , 50 HZ, suitable size and shape with Washer as per existing duly ISI marked to geysers of any make and of capacity 25/50 Litres complete all as specified and as directed by Engineer-in-Charge. .Make;Daspass/Venus/Pearl/CG/Bajaj/Theeta
All as per item No 144.00 here-in-before, but horizontal type.
All as per item No 144.00 here-in-before, but with round plate 6 holes.
S&F in replacement of PVC connection suitable for use in hot water / cold water with brass connector duly threaded internally on both ends of size 18”(45 cm) long complete all as specified and as directed by Engineer-in-Charge.
All as per item No 147.00 here-in-before, but 60cm long.
S&F in replacement of thermostat any type and model suitable to the existing one range 0 to 100 C temperature for geysers of any make horizontal / vertical of capacity 25 Ltr to 50 Ltrs complete all as specified and as directed by Engineer-in-Charge. Make: siemens/ Tonsons control/ Belima.
S&F in replacement of capillary thermostat any type and model suitable to the existing one range 0 to 100 C temperature for geysers of any make horizontal / vertical of capacity 25 Ltr to 50 Ltrs complete all as specified and as directed by Engineer-in-Charge. Make: siemens/ Tonsons control/ Belima.
M&L in replacement of pressure release valve any type as existing suitable for geysers any make horizontal / vertical of capacity 25 to 50 Ltrs complete all as specified and as directed by Engineer-in-Charge.
M&L for Painting to Geyser 25 ltr any make horizonal /vertical with two coat of synthetic enamel white paint with spray gun or with brush after proprerly cleaning the surfaces complete all as specified and as directed by Engineer-in-Charge.
All as per item No 152.00 here-in-before, capacity 50 ltrs.
M &L for Grouting of bolts by making holes in wall of size upto 15 mmx100mm and fixing of Geyser of capacity 25 to 50 Ltrs on wall with nuts and washers complete all as specified and as directed by Engineer-in-Charge.
S&F in repair single pole and neutral enclosure with a two pin earth plug and socket with one single pole MCB of capacity 15/20 Amps complete all as specified and as directed by Engineer-in-Charge.
M&L in repair conection lead 2.5 mtr length 3 core PVC insulated and sheathed multi stranded copper conductor of 2.5 Sqmm 1100 Volt grade complete all as specified and as directed by Engineer-in-Charge.
S & F in repair GI tubing medium grade with all fitting confirming and duly I S I marked, fixed on wall / ceilings or laid in floor of 20 mm bore including GI fittings complete all as specified and as directed by Engineer-in-Charge.
All as per item No 157.00 here-in-before, 15 mm bore pipe.
S & F in repair stop valve cast copper alloy screwed down , high presure with crutch or butterfly handle screwed both ends for iron pipe , 20 mm Bore fancy type chromium plated complete all as specified and as directed by Engineer-in-Charge.
All as per item No 159.00 here-in-before, 15 mm bore pipe.
S&F in repair of MCB single pole 6 to 32 Amps 240 V,10KA, complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement of solar water heater complete with tank, panel, heat pipe, reflector, frame & support of size (Flat type) 212cm x 108 cm x 8 mm for solar water heater of 100 Ltrs capacity complete incuding taking out existing complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement repair solar glass of solar panel of size (Flat type) 212cm x 108 cm x 8 mm for solar water heater of 100 Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
M & L for replacement of round type steel water tank with outer cover as per existing gauge and model of solar water heater of 100 Ltrs capacity including necessary insulation of cold/ Hot water tanks, pipe line and making necessary connection complete all as specified and as directed by Engineer-in-Charge.
M & L for worn out insulation of hot water GI pipe of dia 15 mm of solar water heater system complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Heating Element 3.0 KW, 240V, 50Hz ISI mark suitable for dual power solar water heater 100Ltrs capacity, complete all as specified and as directed. Make;Venus/Pearl /CG/Bajaj/Theeta
S&F in repair of metal clad 20 Amps 2 pin and earth plug with socket, 240 V, complete all as specified and as directed by Engineer-in-Charge.
B S ENGINEERS AND ASSOCIATES
Ish Engineers and Contractors
M/S Rohit Enterprises
D P ENTERPRISES
M/S PARKASH ENTERPRISES
laxmi enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .