Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 10 505 RADHA KUTI ALLEN GANJ KANPUR NAGAR 208001 UTTAR PRADESH | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹50.8 L
EMD Value
₹51,000
Closing Date
16 Sept 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER, EDC, BANDA
Chilla Road, Indira Nagar, Banda
Deposit Works
2022_DVVNL_722945_1
EDCBNDA-22/2022-23
Open Tender
Electrical Works
Turn-key
60 days
BANDA
As per PQR
2 documents required · 2 mandatory
₹3,540
DVVNL
₹51,000
O/O SE, EDC, BANDA
3 Oct 2022
1 Sept 2022
16 Sept 2022
1 Sept 2022
16 Sept 2022
1 Sept 2022
13 Sept 2022
The work of ERECTION OF 11 KV HT LINES on 8.5/11 Mtr. PCC/STP Poles with ACSR Weasel/PVC/XLPE Conductors for giving connections to 14 No. Centres (Pump House) of "JAL JIVAN MISHAN" under NAMAMI GANGE PROJECT of KHATAN (02) & AMALIKAUR(12) PAYJAL YOJNAS at various places/villages as VILL- BARUA KALINGER-IBPS0-30, PONGRI-IBPS-33, NIBHAUR CWR-1, PATWAN CWR-2, GUJENI CWR-3, BABERU DEHAT CWR-4, RAGAULI CWR-5, ALIHA CWR-6, BADOKHAR KHURD CWR-7, PADUI CWR-8, AMLIKAUR CWR-9, SONRAHI CWR-10, PALRA SAHURPUR CWR-11, KARAHIYA CWR-12, (NARAINI/BABERU/TINDWARI/ BADOKHARKHURD) etc. under FULL DEPOSIT SCHEME Year 2022-23 under EDD, BANDA/ATARRA & EUDD BANDA (Turn-key). During the erection of lines has to be done including cartage. Various type petty materials, which are not mentioned in scope of work, but actual required has to be arranged by contractor at his own cost. No extra payment will be made to such petty requirement.
STP 11 Mtr. Long
P.C.C Pole 8.5 Mtr. Long
Stone Pad
11 KV V-type X-arms 65x65x6 mm.
Cross arms holding clamp with N/B for PCC
Cross arms holding clamp with N/B for STP
F-bracket with N/B
11 KV Pin Insulator with Pin
11 KV Disc Insulator with Fitting
Clamp fos channel with N/B
ACSR weasel conductor
MS Top channel 125x65x2240mm.
MS dropper channel 75x75x6x2028mm.
MS Angle 75x75x6x2028mm (T/F Base)
T-off Channel 125x65x1300mm.
Earthing complete (Ms Earthing road of 20x2500 mm & 6 SWG earthing wire etc.)
Stay complete (GI Stay rad 20x1800mm wire 7/8 SWG 5 Kg. claimp, bolt, Nutt , washer etc.)
Danger Board with claimp
PVC cable 3.5x400 Sq. mm
11 KV TPMO Set
11 KV Fuse set
G.I. Wire 07/10 SWG
G.I. Barbed Wire
Binding wire 6 SWG
Gaurding angle for 11 KV line
Gaurding angle Clamp with N/B
Claimp with N/B of suitable size
Number plate
XLPE Cable 11 KV 3x70 Sq.mm.
XLPE Cable 11 KV 3x120 Sq.mm.
11 KV Cable jointing Kit I/D 3x70 Sq. mm
11 KV Cable jointing Kit O/D 3x70 Sq. mm
11 KV Cable jointing Kit I/D 3x120 Sq. mm
11 KV Cable jointing Kit O/D 3x120 Sq. mm
Earthing of Indoor equiepment
G.I. Pipe 6" Dia
Alluminium Tape
11 KV CT/PT Pole Mounted Unit 30/5A
11 KV CT/PT Pole Mounted Unit 10/5A
Alluminium Paint
Red Oxide Paint
Copper L Piece 50x225x10 mm
Copper L Piece 62x225x12 mm
4 Core LT MCB with Box
Alluminium Leg Long Barel Off Size
Plinth and FRP Fencing as per specification/drawing/norms.
Concreating of Pole
Concreating of Stay
shiva engineering AND suppliers
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .