Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 CrAccepted-AOC 142 A B 4 SHETE NAGAR LAXMI PETH SOLAPUR 413001 DIST SOLAPUR | SOLAPUR | SOLAPUR | MAHARASHTRA | 413001 | ₹6.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹7.3 Cr+₹78.6 L (12.0%)Rejected-Finance | ₹7.3 Cr+₹78.6 L (12.0%) | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹3.0 L
Closing Date
28 Apr 2023, 5:30 pmClosed
Superintending Engineer PMGSY Pune New Administrat
Superintending Engineer PMGSY Pune New Administrative Building, 3rd Floor Near Council Hall, Pune-1
ADB SOL (II) 14 Upgradation and Maintenance of road from A) Hanamgaon to Walsang Km 0/000 to 5/510 B) Wangi to Hanuman Nagar Km 0/000 to 4/700 Tal South Solapur Dist. Solapur
2023_MRRDA_893625_11
05/2023-24
Open Tender
Civil Works - Roads
Item Rate
547 days
Solapur
Please refer Tender documents.
9 documents required · 9 mandatory
₹17,700
Yes
₹3.0 L
Yes
2 Apr 2024
13 Apr 2023
2 May 2023
13 Apr 2023
28 Apr 2023
21 Apr 2023
13 Apr 2023 - 28 Apr 2023
Amount
Upgradation & Maintenance of road from Hanamgaon to Walsang Km 0/000 to 5/510 Tal - South Solapur Dist. Solapur
Bill No. 1 Site Clearance, Dismantling and Earth Works
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth up to 300 millimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 millimeter in thickness as per Technical Specification Clause 201.(A) In area of non-thorny jungle. as directed by Engineer in Charge.
Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 meter as per Technical Specification Clause 202. (B)Rubble Stone Masonry in Cement Mortar. as directed by Engineer in Charge.
Removing all types of Hume pipes and stacking within all lift and lead of 1000 meter including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. B) Above 600 millimeter to 900 millimeter dia Hume Pipe as directed by Engineer in Charge.
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubic meter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lift and lead as per Technical Specification Clause 302.3 as directed by Engineer in Charge.
Scarifying existing granular surface to a depth of 50 millimeter and disposal of scarified material with a lift up to 3 meter and leads up to 1000 meter as per Technical Specification Clause 301.4. as directed by Engineer in Charge.
Scarifying the existing bituminous road surface to a depth of 150 millimeter and disposal of scarified material with a lift up to 3 meter and lead up to 1000 m as per Technical Specification Clause 301.4. by Mechanical Means. as directed by Engineer in Charge.
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 as directed by Engineer in Charge.
Construction of embankment with approved material obtained from borrow pits with a lift up to 1.5 meter, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 (A) With lead up to 1000 m. as directed by Engineer in Charge.
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead up to 1000 meter as per Technical Specification Clause 303.1. as directed by Engineer in Charge.
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (II)For Grading II Material. as directed by Engineer in Charge.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel roller 80-100 kN static roller in stages to proper grade and camber, applying and brooming, Crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. (B)By Mechanical Means. as directed by Engineer in Charge.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/ binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. (B)By Mechanical Means. as directed by Engineer in Charge.
Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506. (A)50 millimeter thick Bitumen (S-65) 60/70- VG-30. as directed by Engineer in Charge.
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.225 kilogram per square meter on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. as directed by Engineer in Charge.
20millimeter thick Open-Graded Premix Carpet using waste plastic with Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 millimeter thickness composed of 13.2 millimeter to 5.6 millimeter aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat) By Mechanical Means (II) Bitumen (S-65) VG-30 using Waste Plastic as direct by engineer in charge
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 B)By Mechanical Means Type A (Liquid Seal Coat) Bitumen (S-65) VG-30. as directed by Engineer in Charge.
Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 millimeter, mixed in a concrete mixer of not less than 0.2 cubic meter capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, edges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501(excluding dowel bars and Polythene sheet). as directed by Engineer in Charge.
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50 meter , dressing of sides and bottom and backfilling in trenches with excavated suitable material. (I)Ordinary soil (ii) Up to 3 meter depth by mechanical means ( This item shall be used when total estimate quantity exceeds 100 cubic meter) as directed by Engineer in Charge.
Excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. as directed by Engineer in Charge. II. Ordinary rock (not requiring blasting) Up to 3 meter depth.
Excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. as directed by Engineer in Charge. III.Hard rock (requiring blasting) Up to 3 meter depth including 1.5 meter depth in hard rock.
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 (ii) Rubble filling (For Black cotton Soil).as directed by Engineer in Charge.
Providing and laying of boulder apron laid in wire crates with 4 millimeter dia GI wire conforming to Indian Standards:280 and Indian Standards:4826 in 100 millimeter x 100 millimeter mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kilogram each as per drawing and technical specifications Clause 1301. as directed by Engineer in Charge.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803,1202 & 1203 I) Plain cement concrete grade M 10 (i)Nominal mix 1:3:6. as directed by Engineer in Charge.
Providing and laying plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 For height up to 5 meter I) Plain cement concrete grade M 15 (i) Nominal mix (1:2.5:5). as directed by Engineer in Charge.
Providing weep holes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 millimeter dia Polyvinyl chloride pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 Polyvinyl Chloride pipe 100 millimeter dia. as directed by Engineer in Charge.
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 millimeter with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8. as directed by Engineer in Charge.
Providing and laying reinforced cement concrete pipe Non Pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (D) 600 millimeter dia. as directed by Engineer in Charge.
Providing and laying reinforced cement concrete pipe Non Pressure3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (B) 1000 millimeter dia. as directed by Engineer in Charge.
Supplying, fitting, and placing Thermo Mechanically Treated bar reinforcement SAIL/TATA/JINDAL/RINL/ELECTRATERM or equivalent in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202. as directed by Engineer in Charge.
Providing and laying cement concrete wearing course M 30 grade Excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3. as directed by Engineer in Charge.
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701. as directed by Engineer in Charge.
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved color to give an even shade as per drawings and Technical Specification Clause 1701 ii) English and Roman Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 160 millimeter height, i.e., 1600 centimeter. as directed by Engineer in Charge.
Providing and laying pitching on slope laid over prepared filter media as per drawing and technical specifications Clause 1302 I) Stone/Boulder as directed by Engineer in Charge.
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometer stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703 Ordinary Kilometer Stone (precast). as directed by Engineer in Charge.
Reinforced cement concrete M15 grade kilometer stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703 200 meter Stone (precast). as directed by Engineer in Charge.
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. as directed by Engineer in Charge.
Providing and fixing Semi reflective type typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500 x 1150 millimeter with 75 millimeter square or round steel tube for support fixed in a concrete block of 60 x 60 x 75 centimeter size. Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5 millimeter steel plate. All lettering and painting arrows border etc. will be painted with reflective engineering grade tape as per MORD specifications of required shade and color as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings. (Rate as per RD & WC Deptt. No. CMGSY-2007/CR/145/Yojana-9 dt. 4.4.2007) as directed by Engineer in Charge.
Providing and fixing Semi reflective type typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 millimeter thick, top and middle plate duly welded with MS flat iron 25millimeter x 5meter size on back on edges. The lower plate will be welded with MS angle iron frame of 25millimeter x 25millimeter x 5millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75millimeter x 75 millimeter of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450millimeter x 450millimeter x 600millimeter, 600millimeter below ground level. The top most diamond plate will be welded to middle plate by 47millimeter x 47millimeter of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with reflective engineering grade tape as per MORD specifications of required shade and color. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Note: Printing and lettering for blank spaces on the lower plate will be written as required and paid separately. as directed by Engineer in Charge.
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per Indian Road Congress:67 made of 1.5 millimeter thick MS Sheet duly stove white color in front and gray color on back with red reflective border of 65 millimeter width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and color supported and welded on 47millimeter x 47 millimeter x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 millimeter, 600 millimeter below ground level as per approved drawing Clause 1701.2.2 vi) 600 millimeter x 600 millimeter Square. as directed by Engineer in Charge.
Semi-Reflective Traffic signs Providing and erecting direction and place identifications of semi reflective sign boards as per Indian Road Congress:67 made of 2 millimeter thick M.S. Sheet duly stove enameled paint in white color in front and grey color on back with red reflective border of 70 millimeter width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and color. Supported and welded on 47 millimeter x 47millimeter of 12 SWG Square tube of 3050 millimeter height duly strengthened by 25 millimeter x 5 millimeter M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 millimeter x 450 millimeter x 600 millimeter, 600 millimeter below ground level as per approved drawing and Technical Specification Clause 1701. as directed by Engineer in Charge.
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per Indian Road Congress:67 made of 1.5 millimeter thick MS Sheet duly stove white color in front and gray color on back with red reflective border of 65 millimeter width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and color supported and welded on 47millimeter x 47 millimeter x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 millimeter, 600 millimeter below ground level as per approved drawing Clause 1701.2.2. ii) 600 millimeter equilateral triangle as directed by Engineer in Charge.
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per Indian Road Congress:67 made of 1.5 millimeter thick MS Sheet duly stove white color in front and gray color on back with red reflective border of 65 millimeter width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and color supported and welded on 47millimeter x 47 millimeter x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 millimeter, 600 millimeter below ground level as per approved drawing Clause 1701.2.2 v) 600 millimeter x 450 millimeter rectangular. as directed by Engineer in Charge.
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per Indian Road Congress:67 made of 1.5 millimeter thick MS Sheet duly stove white color in front and gray color on back with red reflective border of 65 millimeter width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and color supported and welded on 47millimeter x 47 millimeter x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 millimeter, 600 millimeter below ground level as per approved drawing Clause 1701.2.2 v) 600 millimeter Circular as directed by Engineer in Charge.
Providing and Laying of Rumble strips with Plastirib 2K,or equivalent 2 component cold plastic profiled material to give total width of 500mm and height of 10mm.Ramp provided to give width of 145mm,width of ribs to be 55mm laid at center to center distance of 35mm,with reflective glass beads @350gm/Square Meter. The finished surface to be levelled ,uniform and free from streaks and holes ,to be applied on the edge lines ,including surface cleaning and cost of all materials etc. complete.
Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS molded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kilogram tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Indian Road Congress No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 millimeter, 100 millimeter and 102 +/- 2 millimeter and with minimum reflective area of 13 Square centimeter on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 millimeter and height not less than 30+/- 2 millimeter) from the body is to be a minimum value of 500 Kilogram. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer. The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.as directed by Engineer in Charge.
Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 centimeter high above ground level, painted black and white in 15 centimeter wide strips, fitted with 80x100millimeter rectangular or 75millimeter dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to Indian Road Congress: 79 and the drawings as directed by Engineer in charge.
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 millimeter thick including reflectorizing glass beads @ 250 grams per square meter area, thickness of 2.5 millimeter is exclusive of surface applied glass beads as per Indian Road Congress:35 .The finished surface to be level, uniform and free from streaks and holes. Complete. as directed by Engineer in Charge.
Providing and Fixing of Retro Reflectorised 300 x 900 millimeter Hazard marked boards made out of aluminum sheet bonded with white retro reflective sheeting ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per Indian Road Congress:67-2012 Table No 8.3, supported with back support frame 25millimeter x 25millimeter x3millimeter , duly painted on back side with two coats of grey stove enamelpaint and supported on one no. mild steel angle iron post 75 millimeter x 75millimeter x 6 millimeter , 3.5 meter long firmly fixed to the ground by means ofproperly designed foundation with M25 grade cement concrete 45 cetimeterx 45 cetimeter x 60 cetimeter, 60 cetimeter below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cetimeter width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.
Upgradation & Maintenance of road from Wangi to Hanuman Nagar Km 0/000 to 4/700 Tal - South Solapur Dist. Solapur
Bill No. 1 Site Clearance, Dismantling and Earth Works
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth up to 300 millimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 millimeter in thickness as per Technical Specification Clause 201.(A) In area of non-thorny jungle. as directed by Engineer in Charge.
Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 meter as per Technical Specification Clause 202. (B)Rubble Stone Masonry in Cement Mortar. as directed by Engineer in Charge.
Removing all types of Hume pipes and stacking within all lift and lead of 1000 meter including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. B) Above 600 millimeter to 900 millimeter dia Hume Pipe as directed by Engineer in Charge.
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubic meter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lift and lead as per Technical Specification Clause 302.3 as directed by Engineer in Charge.
Scarifying existing granular surface to a depth of 50 millimeter and disposal of scarified material with a lift up to 3 meter and leads up to 1000 meter as per Technical Specification Clause 301.4. as directed by Engineer in Charge.
Scarifying the existing bituminous road surface to a depth of 150 millimeter and disposal of scarified material with a lift up to 3 meter and lead up to 1000 m as per Technical Specification Clause 301.4. by Mechanical Means. as directed by Engineer in Charge.
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 as directed by Engineer in Charge.
Construction of embankment with approved material obtained from borrow pits with a lift up to 1.5 meter, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 (A) With lead up to 1000 m. as directed by Engineer in Charge.
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead up to 1000 meter as per Technical Specification Clause 303.1. as directed by Engineer in Charge.
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (II)For Grading II Material. as directed by Engineer in Charge.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel roller 80-100 kN static roller in stages to proper grade and camber, applying and brooming, Crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. (B)By Mechanical Means. as directed by Engineer in Charge.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/ binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. (B)By Mechanical Means. as directed by Engineer in Charge.
Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506. (A)50 millimeter thick Bitumen (S-65) 60/70- VG-30. as directed by Engineer in Charge.
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.225 kilogram per square meter on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. as directed by Engineer in Charge.
20millimeter thick Open-Graded Premix Carpet using waste plastic with Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 millimeter thickness composed of 13.2 millimeter to 5.6 millimeter aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat) By Mechanical Means (II) Bitumen (S-65) VG-30 using Waste Plastic as direct by engineer in charge
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 B)By Mechanical Means Type A (Liquid Seal Coat) Bitumen (S-65) VG-30. as directed by Engineer in Charge.
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50 meter , dressing of sides and bottom and backfilling in trenches with excavated suitable material. (I)Ordinary soil (ii) Up to 3 meter depth by mechanical means ( This item shall be used when total estimate quantity exceeds 100 cubic meter) as directed by Engineer in Charge.
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 (ii) Rubble filling (For Black cotton Soil).as directed by Engineer in Charge.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803,1202 & 1203 I) Plain cement concrete grade M 10 (i)Nominal mix 1:3:6. as directed by Engineer in Charge.
Providing and laying plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 For height up to 5 meter I) Plain cement concrete grade M 15 (i) Nominal mix (1:2.5:5). as directed by Engineer in Charge.
Providing and laying reinforced cement concrete pipe Non Pressure 3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (D) 600 millimeter dia. as directed by Engineer in Charge.
Providing and laying reinforced cement concrete pipe Non Pressure 2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (D) 600 millimeter dia. as directed by Engineer in Charge.
Providing and laying reinforced cement concrete pipe Non Pressure 3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (B) 1000 millimeter dia. as directed by Engineer in Charge.
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701. as directed by Engineer in Charge.
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved color to give an even shade as per drawings and Technical Specification Clause 1701 ii) English and Roman Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 160 millimeter height, i.e., 1600 centimeter. as directed by Engineer in Charge.
Providing and laying pitching on slope laid over prepared filter media as per drawing and technical specifications Clause 1302 I) Stone/Boulder as directed by Engineer in Charge.
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometer stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703 Ordinary Kilometer Stone (precast). as directed by Engineer in Charge.
Reinforced cement concrete M15 grade kilometer stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703 200 meter Stone (precast). as directed by Engineer in Charge.
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. as directed by Engineer in Charge.
Providing and fixing Semi reflective type typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500 x 1150 millimeter with 75 millimeter square or round steel tube for support fixed in a concrete block of 60 x 60 x 75 centimeter size. Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5 millimeter steel plate. All lettering and painting arrows border etc. will be painted with reflective engineering grade tape as per MORD specifications of required shade and color as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings. (Rate as per RD & WC Deptt. No. CMGSY-2007/CR/145/Yojana-9 dt. 4.4.2007) as directed by Engineer in Charge.
Providing and fixing Semi reflective type typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 millimeter thick, top and middle plate duly welded with MS flat iron 25millimeter x 5meter size on back on edges. The lower plate will be welded with MS angle iron frame of 25millimeter x 25millimeter x 5millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75millimeter x 75 millimeter of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450millimeter x 450millimeter x 600millimeter, 600millimeter below ground level. The top most diamond plate will be welded to middle plate by 47millimeter x 47millimeter of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with reflective engineering grade tape as per MORD specifications of required shade and color. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Note: Printing and lettering for blank spaces on the lower plate will be written as required and paid separately. as directed by Engineer in Charge.
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per Indian Road Congress:67 made of 1.5 millimeter thick MS Sheet duly stove white color in front and gray color on back with red reflective border of 65 millimeter width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and color supported and welded on 47millimeter x 47 millimeter x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 millimeter, 600 millimeter below ground level as per approved drawing Clause 1701.2.2 vi) 600 millimeter x 600 millimeter Square. as directed by Engineer in Charge.
Semi-Reflective Traffic signs Providing and erecting direction and place identifications of semi reflective sign boards as per Indian Road Congress:67 made of 2 millimeter thick M.S. Sheet duly stove enameled paint in white color in front and grey color on back with red reflective border of 70 millimeter width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and color. Supported and welded on 47 millimeter x 47millimeter of 12 SWG Square tube of 3050 millimeter height duly strengthened by 25 millimeter x 5 millimeter M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 millimeter x 450 millimeter x 600 millimeter, 600 millimeter below ground level as per approved drawing and Technical Specification Clause 1701. as directed by Engineer in Charge.
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per Indian Road Congress:67 made of 1.5 millimeter thick MS Sheet duly stove white color in front and gray color on back with red reflective border of 65 millimeter width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and color supported and welded on 47millimeter x 47 millimeter x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 millimeter, 600 millimeter below ground level as per approved drawing Clause 1701.2.2. ii) 600 millimeter equilateral triangle as directed by Engineer in Charge.
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per Indian Road Congress:67 made of 1.5 millimeter thick MS Sheet duly stove white color in front and gray color on back with red reflective border of 65 millimeter width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and color supported and welded on 47millimeter x 47 millimeter x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 millimeter, 600 millimeter below ground level as per approved drawing Clause 1701.2.2 v) 600 millimeter x 450 millimeter rectangular. as directed by Engineer in Charge.
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per Indian Road Congress:67 made of 1.5 millimeter thick MS Sheet duly stove white color in front and gray color on back with red reflective border of 65 millimeter width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and color supported and welded on 47millimeter x 47 millimeter x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 millimeter, 600 millimeter below ground level as per approved drawing Clause 1701.2.2 v) 600 millimeter Circular as directed by Engineer in Charge.
Providing and Laying of Rumble strips with Plastirib 2K,or equivalent 2 component cold plastic profiled material to give total width of 500mm and height of 10mm.Ramp provided to give width of 145mm,width of ribs to be 55mm laid at center to center distance of 35mm,with reflective glass beads @350gm/Square Meter. The finished surface to be levelled ,uniform and free from streaks and holes ,to be applied on the edge lines ,including surface cleaning and cost of all materials etc. complete.
Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS molded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kilogram tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Indian Road Congress No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 millimeter, 100 millimeter and 102 +/- 2 millimeter and with minimum reflective area of 13 Square centimeter on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 millimeter and height not less than 30+/- 2 millimeter) from the body is to be a minimum value of 500 Kilogram. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer. The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.as directed by Engineer in Charge.
Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 centimeter high above ground level, painted black and white in 15 centimeter wide strips, fitted with 80x100millimeter rectangular or 75millimeter dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to Indian Road Congress: 79 and the drawings as directed by Engineer in charge.
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 millimeter thick including reflectorizing glass beads @ 250 grams per square meter area, thickness of 2.5 millimeter is exclusive of surface applied glass beads as per Indian Road Congress:35 .The finished surface to be level, uniform and free from streaks and holes. Complete. as directed by Engineer in Charge.
Providing and Fixing of Retro Reflectorised 300 x 900 millimeter Hazard marked boards made out of aluminum sheet bonded with white retro reflective sheeting ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per Indian Road Congress:67-2012 Table No 8.3, supported with back support frame 25millimeter x 25millimeter x3millimeter , duly painted on back side with two coats of grey stove enamelpaint and supported on one no. mild steel angle iron post 75 millimeter x 75millimeter x 6 millimeter , 3.5 meter long firmly fixed to the ground by means ofproperly designed foundation with M25 grade cement concrete 45 cetimeterx 45 cetimeter x 60 cetimeter, 60 cetimeter below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cetimeter width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.
DATTATRAY SANDIPAN MULE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .