| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC H NO 257 1ST FLOOR KAMALA NEHRU NAGAR BATHINDA PB | BATHINDA | BATHINDA | PUNJAB | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹47.0 L+₹1.5 L (3.19%)Rejected-Finance NA | L2 | Rejected-Finance Quoted other than lowest rate. | |
| 3 | L3₹47.2 L+₹1.7 L (3.65%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate. | |
| 4 | L4₹47.4 L+₹1.9 L (4.12%)Rejected-Finance | L4 | Rejected-Finance Quoted other than lowest rate. | |
| 5 | L5₹47.5 L+₹1.9 L (4.25%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L5 | Rejected-Finance Quoted other than lowest rate. |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
2 Nov 2023, 6:00 pmClosed
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA Pin-151004
SPECIAL REPAIR TO TOILET CUM BATHROOM OF OTM ACCN BLDG No. P-15 AND P-17 AND SPECIAL REPAIR TO BLDG No. T-606 UNDER AGE BR-V AND AGE E/M OF GE NORTH BATHINDA AT BATHINDA MIL STN
2023_MES_594740_4
8938/NIT-04/23-24
Open Tender
Civil Works
Item Rate
180 days
BATHINDA
Class D Category a(i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹1 L
Yes
28 Dec 2023
18 Oct 2023
4 Nov 2023
18 Oct 2023
2 Nov 2023
27 Oct 2023
18 Oct 2023 - 21 Oct 2023
Amount
SCHEDULE 'A' B/R Works
Taking down chowkhats or frames with shutters (without taking off shutters from the frames, wooden/PVC doors/steel ventilator) area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 100mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing 100mm long powder coated mild steel butt hinges medium weight cold rolled complete all as specified & directed by Engineer-in-charge.
Supply and fixing anodised aluminium handle cast type 100mm long complete all as specified & directed by Engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply and fixing factory made 125 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , including butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ.
Material and labour for PCC (1:3:6) type C-0, using 12.5 mm graded aggregated as in back filling of chowkhats and for hold fast complete all as specified and as directed by Engineer-in-Charge
Supply & fixing factory made plain framed panelled shutters (two panels as approved), 35mm thick of 2nd class hard wood with lock rail and panel inserts of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhat complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply & fixing factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated (two panels as approved) and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8 and fitted to chowkhats, menbers shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item of BOQ.
Supply & fixing galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples complete all as specified & directed by Engineer-in- charge.
Supply and fixing mild steel 300mm long rat tail rod pattern spring including roller and roller plate and fixing to wooden frame with screw complete all as specified and as directed by Engineer-in- charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing aluminium anodised sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engineer-in- charge.
Supply and fixing anodised aluminium handle cast type 150mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including taking out old rusted broken window any type and guard bars including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast and making good disturbed area of walls and cills to match the existing surfces by bricks / plastering works and painting work etc complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, without glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including taking out old rusted broken window any type including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast and making good disturbed area of walls and cills to match the existing surfces by bricks / plastering works and painting work etc complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, suitable steel handle, steel peg stay, fixing lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips, complete all as specified & directed by Engineer-in- charge.
Supply & fixing 3mm thick sheet glass ordinary quality in squares not exceeding 0.5sqm in each pane (for new door/window) and fixed in any type of doors/windows/ventilators with wooden bead/pin tacked/with oil putty etc. as required or as directed including cutting of glass as per site requirement complete all as specified & directed by Engineer-in- charge.
Supply & fixing, 3mm thick figured glass pin head type in squares not exceeding 0.5sqm in each pane for steel or wooden doors/wondows including fixing material complete all as specified and as directed by Engineer-in- charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Material and labour for Preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Demolition and Digging out sunken floor filling including taking out unserviceable WC and removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site, complete all as specified and as directed by Engineer-in- charge.
Supply only intergral water proofing compound, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for sunken treatment to sunken floor, cleaning the surface by wire brush, rendering to floor and sides with 10mm thick in cement mortar (1:4) including mixing of WPC in mortar @ 3% of cement content, finished even and smooth without using extra cement, after that material and labour providing for applying two coats of two components one part liquide two parts powder ready to use cementitious water proofing coating on properly prepared surface by brushing having elongation of > 50% for the applying water proofing treatment as per following on horizontal and verticle surfaces of sunken floor complete all as per manufacture instructions as directed by Engineer-in-charge. (i) Applying 1st coat of two components modified polymer coating. (ii) Provn of glasses fiber mess of 2mm x 2mm immediately on alone coating (iii) Applying 2nd coat of two components modified polymer coating after 72 hrs on horizontal and verticle surfaces. NOTE:-(i) Complete treatment to be carried out by authorised applicator of water proofing manufacture. (ii) WPC for mixing in CM shall be measured & paid separately as Supply only.
Material and labour for 30mm thick cement concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in floor, sunken floor etc, finished rough to receive tiles, including mixing of WPC in mortar, complete all as specified and as directed by the Engineer-in-Charge. (Note :- WPC shall be measured & paid separately as Supply only)
Material & Labour for PCC (1:7:12) type F2 using 40mm graded stone aggregate as loose filling of sunken floors complete all as specified and as directed by Engineer-in-charge.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm// 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in repair, 450 mm long PVC connection 15mm size with PTMT nuts, complete all as specified & directed by Engineer-in-charge.
Supply & fixing in repair, stop valve/angle valve cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing in repair, chromium plated shower rose 200mm x 200mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in repair, concealed stop cock cast copper alloy, chromium plated, fancy type, long shank and cup, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock shall be as given in SSR or in relevant IS.
Supply & fixing brass chromium plated tubular towel rail 20mm dia 'D' type, 600mm long between flanges fixed to plug , bracket with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair, soap dish MS chromium plated of with brass screw complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair, bib tap cast copper alloy, chromium plated with crutch or butterfly handle with capstan head, wall flange,fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore, complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 25mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 25mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing vitreous china wash hand basin oval type under counter, white colour, of size 595mm x 420mm x 200mm excluding taps, but including fancy type 32mm waste coupling and waste pipe, fixing/counter sunked in granite slab, complete all as specified and as directed by Engineer-in-Charge. Note :- Granite slab if required, shall be measured and paid separately under appropriate item of BOQ.
Supply & fixing in replacement vitreous china wash basin, white, flat back of size 550mm x 400mm, including 32mm chromium plated waste coupling and PVC waste pipe including bracket and cutting for and pinning in end of bracket or erecting, complete all as specified and as directed by Engineer-in-Charge. (Note :- Pillar tap if required in replacement, shall be measured & paid separately as under appropriate item of BOQ.)
Supply & fixing in replacement vitreous china urinal, half stall type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar, including taking down old urinal with fittings complete all as specified & directed by Engineer-in-charge.
Supply & fixing in replacement 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (interval of 1m) including nut bolt and PCC work, including dismantling/taking down old pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair, gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes, complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Supply & fixing in repair vitreous China squatting pan 'Orissa' pattern white of size 580mmx440mm with integral foot rests (excluding flushing cistern, flush pipe above floor and trap), including demolation of tile, PCC, taking out old WC, taking out lime concrete filling and after fixing new WC re filling lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, including fixing PVC flush pipe upto finished floor level, joints of flush pipe and trap make leakproof and testing before filling concrete and including all other connected work as required upto entire satisfaction of Engineer-in-charge complete all as specified and as directed by Engineer-in- charge. (NOTE : Tile work with screed shall be measured and paid separately under appropriate item of this schedule.
Supply & fixing in replacement vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
Dismantling cast iron drain pipes, jointed in cement mortar of any description any dia from wall and taking out from trenches including all fittings (bend, trap, cowl, branch piece etc) and removing from the site complete all as directed by Engr-in-Charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay including nut bolt and jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay including nut bolt and jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair, 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) without oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair, 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair, 100mm bore cast iron cowl complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair, 100mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch fitted with oval access door as specified & directed by Engineer-in- charge.
Supply and fixing in repair, 150mm x 150mm size salt glazed stone ware gully traps, square or round mouthed, type 'P' complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair, 75mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) without oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair, 75mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair, 75mm bore cast iron cowl complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair, 75mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch fitted with oval access door as specified & directed by Engineer-in- charge.
Supply and fixing in repair, Cast iron floor trap 75mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement pillar tap cast copper alloy with capstan head, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Dismantling brick/PCC terracing tiles single layer in roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge.
Demolition of mud in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part there of) including removing/cutting uprooting grass, vegetations and roots of small plants etc on roof floor and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for 15mm thick in cement mortar (1:3), mixing with WPC in mortar 3% of cement on existing surface of roof of concrete surface on roof slab after wire brushing and cleaning top surface and finished even and smooth without using extra cement, complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid separately)
Material and labour for cleaning of top surfaces of concrete roof slab, lime terracing, or surface of tiles with wire brush including flashing and junction of parapets etc., and surface painting with layer of blown grade bitumen of any penetration applied hot @ 1.7 Kg per Sqm and priming the surface @ 0.30 Kg per Sqm and laying 3mm thick APP based polymer membrane of weighing not less than 3.5 kg per Sqm reinforced with polyster non woven fabric (weight not less than 150 Gm per Sqm) laid on primed surfaces at by torch application with side overlap 75mm and end overlap 100mm and tucked into the chasesas a treatment for moderate condition, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for lime concrete terracing using brick aggregate and surkhi as specified in clause 11.11 and laying as specified in clause 11.27 of MES Sch Part-I (2009) minimum thickness at edge 40mm and increasing uniformly towards ridges to obtain a chain slope 1:40, the top shall be trowelled with the addition of jaggery solution and finished smooth complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40mm thick brick tiles laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with WPC @ 3% of cement content and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for 40mm thick brick tiles (old serviceable tiles obtained from demolition/dismantled item shall be reused) laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with WPC @ 3% of cement content and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for flush pointing to brick tiles laid flat in Cement mortar (1:3) including racking out joint & pointing to brick tiles, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for PCC (1:2:4) Type B0 using 12.5mm graded stone aggregate as in roof kerb (golla) or mud stops, coping, bends, benching, side of roof sheet & similar work etc rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of WPC in mortar @ 3% of cement content, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for rendering/plastering 5mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement including demolition of cement concrete (unreinforced, existing plinth floor, hard standing etc ) of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Demolition of cement concrete reinforced of any discription and in any position not otherwise specifically provided (like kitchen shelf, WHB counter shelf, slabs, beams, staircase, lintels, chajja, RCC OHT, RCC fins, roof projection, RCC parapets and similar suspended works), including cutting of steel as directed and prepare the surface to casting new shelf/slabs and removing rubbish materials from site and deposited as directed complete all as specified and as directed by Engineer-in-charge
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in chajjas, beams, staircases, landing, fins, facia and similar suspended works complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 6 mm to 8mm dia cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Form work to chullah hoods, chajjas, trough and similar items including edges rough finished flat surfaces complete all as specified & directed by Engineer-in- charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and including dismantling/taking down of existing unserviceable PVC water storage tanks of any description, complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as under appropriate item of BOQ.)
Supply and fixing ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 25mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Material and labour for preparing newly plastered or concrete surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from ceiling by scraping down with using steel patti wire/ brush / sand papering or by any other mean, remove / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc brooming all dust including applying white cement based putty where required for filling to depressions/nail holes/light cracks etc and to make surface even and smooth and also using sander machine (with provision of dust sucking) on uneven surface to make the surface even and smooth (before and after applying putty as per site situation) upto entire satisfaction of Engineer-in-charge, and after preparing the surface smooth applying two coats of white wash with using paint brush, complete all as specified and as directed by Engineer-in-Charge. NOTE : - Complete removal /scraping to old existing treatment as directed by Engineer-in-charge, each stage i.e after complete removal and before applying white wash as specified above, the surface shall be passed in writing by the Enigineer-in-charge in site order book.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other means, and preparing the surfaces smooth by applying white cement based putty to make the surface even and smooth by using sander machine (with provision of dust sucking) upto entire satisfaction of Engineer-in-charge, and after preparing the surfaces applying two coats of oil emulsion distemper (washable), as approved tint/colour by using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down and preparing the surfaces smooth and after that applying average 3mm thick layer (1.5mm thick each in two layer application) of white cement based putty (wall care putty, make Birla JK or equvilent as approved by Engineer-in-charge), after applying putty first and second coat sanding the surface as per requirement by using mechanical sander machine to make the surface even and smooth upto entire satisfaction of Engineer-in-charge and after prepare the surface smooth applying two coats of oil bound distemper (washable) as per approved tint/colour by using paint brush or roller brush complete all as specified and as directed by Engineer-in-Charge. NOTE : - Each stage i.e after complete removal and before applying OBD as specified above, the surface shall be passed in writing by the Enigineer-in-charge.
Material and labour for preparation of old plastered surfaces of internal walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/mechanized sanding etc., (preparatory to paint as directed) complete all as specified. (ii) Two coats of 100% acrylic emulsion paint of approved tint by using airless spray/ roller over and including a coat of acrylic internal primer.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of weather coat apex paint (External emulsion) as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down and preparing the surfaces smooth and after that applying two coats of weather coat apex paint (external emulsion) as per approved tint/colour by using airless spray or roller over and including a coat of acrylic external primer complete all as specified and as directed by Engineer-in-Charge.
Dismantling AC sheets (corrugated, semi corrugated etc.) as in roof coverings complete, all as specified & directed by Engineer-in-charge.
Dismantling timber scantling 40 Sq.cm and over in section, in any position (unframed work) complete, all as specified & directed by Engineer-in-charge.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick, any colour having tensile strength of 550 Mpa as in ridge (including cutting and bent to shape), roof covering, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Material and labour for mild steel work tubular poles/post including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to latest relevant IS grade St-240 complete all as specified & directed by Engineer-in- charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets fixed in any position with nails fixed with screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing anodised aluminium snap grid frame work of size of grid 605 x605mm for false ceiling including necessary notching and prepared holes, the snap grid shall consist of anodised aluminium main tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM, cross and Intermediate tee of size 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM. The main and cross tee shall be jointed at junction with steel screws or MS bolts, nuts and washers, the snap grid (main / cross tee sections) shall be supported at ends all along the wall with anodised aluminium angle of size 35mm x25mmx 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and duly suspended with 4mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 12mm thick gypsum board in grid fixed in false ceiling grid made of aluminium as per above specifications complete all as specified and as directed by Engineer-in-charge.
Material and labour providing precast cement concrete set in cement mortar 1:4 type B-1, 1:2:4 (20mm graded aggregate) in window or door cills, lintels bressumers, steps quoin blocks for use with masonary including necessary reinforcement etc., complete all as specified and as directed by Engineer-in-charge.
Material and labour for machine cut 20 to 25 mm thick, Kota stone slab (size of slab not less than 550x550mm) as in flooring, laid over and including 15 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish) and polishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for machine cut 20 to 25mm thick, Kota stone slab as in riser of steps, skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish ) and polishing by machine, including machine cutting to make it square or rectangular complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete including fabrication as directed, including hold fast, locking arrangement, sliding door bolt, stopper etc conforming to Fe-410-W (Gde E-250) quality A complete all as specified and as directed by Engineer-in- charge
Material and labour for brick work in half brick thick wall using burnt clay brick (sub class 'B' old size burnt clay brick) straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and directed by Engr-in-Charge
M&L for guniting short crating of RCC columns, beams, fins, facias and similar items as per manufacture instructions average thickness exc 25 mm but not exc 40mm complete all as specified and directed by Engr-in-Charge
M&L for guniting short crating of RCC columns, beams, fins, facias and similar items as per manufacture instructions average thickness not exc 25mm complete all as specified and directed by Engr-in-Charge
Roughening of old concrete floor by picking and prepare the surface to receive the screed for tilling/kota stone, sweeping cleaning and washing down with water to remove dust etc complete all as specified and directed by Engr-in-Charge
SCHEDULE 'A' INTERNAL ELECTRIFICATION WORKS
Taking down old unsv copper/aluminium point/submain wiring concealed / batten (light, fan, socket or power/submain) complete, including fixtures and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed by Engineer-in-charge.
Material and labour for point wiring for one light/fan/5 Amps independent socket point/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into an including new concealed PVC rigid/steel conduit 1.8mm wall thickness ISI marked terminated into CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified. Note : (a) wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clips all as directed by Engr-in-Charge.
All as per item No 124 here in before but for socket outlet 3/5 pin 5/6 Amp 250 Volts on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 124 here in before but for socket outlet 3/5 pin 5/6 Amp 250 Volts on independent board but not below the switch board, complete all as specified and as directed by Engineer-in-Charge.
All as per srl items No. 124 here-in-before but for 3/5 pin 15 Amp socket out let by using 2.5 sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent board including provn of 2.5 sqmm unshearhed, multi stranded copper conductor cable FR-LSH continues as earth wire connecting to earth dolly etc. complete all as specified and directed by Engineer-in-Charge.
All as per item No 124 here in before but control of flood light 70 W in 1 with cable 2.5 Sqmm multistranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sqmm PVC insulated copper conductor FRLSH cable continuos as earth wire connected to earth dolly, conductor etc., complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano, flush type single pole one way 5 Amp, 240 volts, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing switch piano flush button single pole one way 15 Amp, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Socket outlet 2 in 1, 5 Pin, 5/6A, flush type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing socket outlet 2 in 1, 5 pin, 15/16 Amp 240 volt multi purpose flush type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing stepped type (1-4), electronic Fan regulator (two module), 100 watt, 250 volts, fixed on laminated sheet suitable for ceiling fan, complete all as specified by Engineer-in-charge.
Supply and fixing ceiling rose, 3 phase / PVC / Polycarbonate isolated body two to three terminal series 20 x 50mm, 6 Amp three terminal, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of new generation energy saving wall mounted LED tube light batten fittings, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 20 Watt LED power factor > 0.95, 100 lumen/watt duly fitted on pvc sqaure block 5700 K (4' ft long) with LED rod 20 watt, 230 Volts 50 Hz, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of LED mirror light fiting 9/10 watt, 6000K, lineer & compact with decorative grey end caps, polycarbonate body and ribbrd opal diffuser complete fitting with lamp and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for replacement of Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length, complete all as specified and directed by Engineer-in-charge. Note : Wiring shall be done in proper colour coding.
Material and labour for replacement of Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length, complete all as specified and directed by Engineer-in-charge. Note : Wiring shall be done in proper colour coding.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB single pole and Neutral 40 Amp suitable for 230 volt, 10KA, 'C' curve, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB single pole and Neutral 63 Amp suitable for 230 volt, 10KA, 'C' curve, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB single pole 5-32 Amp suitable for 240 volt, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing (Concealed with wall) single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply including taking down old unserviceable enclosure complete all as specified and directed by Engineer-in-Charge.
Taking down old and rusted and unserviceable exhaust fan of size 450mm sweep from toilets and deposited to MES store, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of exhaust fan stainless steel body 450 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Exhaust fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and fixing in replacement wall mounted LED Batten T-8 Retro LED 18/20 watt (100 lumens per watt), appx 4 feet long, pre wired including LED tube light with in built driver, not less than 6000K, complete fitting and all other accessories fitting arrangements including electric connection including taking down old unserviceable light fittings any type at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement Sleek Pressure die cast aluminium housing, heat resistant glass, energy saving, IP65 protection, better optics for uniform distribution street/Roadway luminaire with high power LED 35 watt complete fitting with driver, LED strip and all other accessories etc, suitable for direct mounting on pipe bracket, fixing on wall with and including brackets made out of GI tubing lightwith suitable bent to shape at 120 degree angle at half metre from bottom (as per sample), fixing with MS clamp (02 Nos) and nut bolts, including before fixing applying two coats of aluminium paint on bracket and clamp over a coat of red oxide primer, including making electric connection with using twin core copper cable of suitable size including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement energy saving IP 66 flood light luminaire with high power COB LED light fitting 70 watt LED, 5000K complete fitting with LED and all other accessories and fitting arrangements including connecting electric connection, including taking down unserviceable old fitting any type complete all as specified and directed by Engineer-in-Charge. Note:- Cost of making arrangements for replacing the light fitting at hanger roof/wall or any other position directed by the Engr-in-Charge, deemed to be included in quoted rate.
Supply and fixing in repair air termination single pointed aluminum rod 12 mm dia and 300 mm long complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair test point of MS sheet with arrangement and including of terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm , drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess ro chases or burried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required Copper Strip 20x 3.15 mm, including taking down old unserviceable, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I), including taking down old earthing, complete all as specified and and as directed by Engineer-in-charge.
Taking out old unserviceable under ground LT XLPE / PVC cable of any size from trenches /wall / roof/ road/ pipe / pole / DB including taking out of brick layer of cable protection, complete all as specified and and as directed by Engineer-in-charge. Note:- Excavation and earth work shall be measured and paid for separately under appropriate item of BoQ.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, taking out old pipe and laying new pipe line, for taking out of LT under ground cable and laying of cables or pipes (where provided) for protection of cable or fixing poles and stays etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / hard standing / along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 Volts grade with aluminium conductor having cross sectional area 10 Sqmm 2 core, conforming to IS-7098 (Part-1-1998) complete all as specified and and as directed by Engineer-in-charge. Note:- Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately under appropriate item of BoQ.
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing/laying GI tubing, medium grade, 40 mm bore for protection of cable or earthing lead wire under hardstanding/fixed along poles/wall, laid in in trenches etc., complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with copper plate electrode of size 60cm x 60cm x 3.15mm thick electrode and 20mm x 3mm copper strip as earthing lead buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to copper earth strip 20mm x 3mm by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I), including taking down old earthing, complete all as specified and and as directed by Engineer-in-charge.
Supply and fixing in repair RCBs for earth leakage, overload and short circuit protection suitable for 230 volts, AC supply 63 Amps, double pole rupturing capacity not less than 30 mA, complete all as specified and as directed by Engineer-in-Charge.
M/s Vandana Builders
B D BATRA AND SONS
M/s DHEERAJ JAIN CONSTRUCTION COMPANY
Ajay Enterprises
M/s NIRMAN BUILDERS
M/S SAI BUILDERS
V K CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .