Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC 131 NILMONI BHATTACHARJEE LANE KADAL BERHAMPORE MURSHIDABAD W B PIN 742102 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742102 | L1 | Accepted-AOC Quoted rate found Lowest (L1). | |
| 2 | L2₹15.4 L+₹39,880 (2.66%)Rejected-Finance 159B M G ROAD HARIDEVPUR KOLKATA WEST BENGAL 700082 UDYAM WB 10 0018308 | KOLKATA | WEST BENGAL | 700082 | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). | |
| 3 | L3₹17.2 L+₹2.2 L (14.9%)Rejected-Finance GROUND FLOOR 109 186 114 LAHIRI VILLA NEW BANSBARI MALDA WEST BENGAL 732102 | MALDA | MALDA | WEST BENGAL | 732102 | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). | |
| 4 | L4₹17.8 L+₹2.8 L (18.5%)Rejected-Finance 63 PILKHANA ROAD BERHAMPORE MURSHIDABAD 742101 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L4 | Rejected-Finance Quoted rate found 4th Lowest (L4). | |
| 5 | L5₹18.5 L+₹3.5 L (23.4%)Rejected-Finance PURATULI MALDA 732101 | MALDA | MALDA | WEST BENGAL | 732101 | L5 | Rejected-Finance Quoted rate found 5th Lowest (L5). |
Tender Value
Refer Docs
EMD Value
₹39,940
Closing Date
7 Jul 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, PWD, Malda Electrical Division
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Construction of 02 (Two) Nos Watch Tower at Muchia PHC and Nabadharampur - SITC of 4 Nos. High Mast Tower.
2020_WBPWD_286581_1
WBPWD/EE/MED/e-NIT-49/2019-20 (2nd Call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Malda
Please refer Tender documents.
6 documents required · 6 mandatory
₹39,940
18 Dec 2020
23 Jun 2020
9 Jul 2020
24 Jun 2020
7 Jul 2020
24 Jun 2020
120 days
Amount
Supply & Installation of hotdip galvanized flange mounted polygonal tapered type High Mast of 12.5 mtr normal menting height suitable for & speed of 50/m/s (180 m/brs) of segments defaults 2 nos finished section in length with 360mm bottom (A/F) and Top 150 mm (A/F) dia and 360mm circular box plate 445x25 PCD of bolts 461 size of µ-24 x1200 no of bolts & door openly 300x1400 inch which SWL CAP 750Kg 65m dia of steel rope with suspension system, power motor tool for electrical operation hard frame galvanized lantren carriage arrangement with high power 3Ph 2HP motor suitable for 8 nos Luminaries systematically & its control gear boxes & light fittings incl. neon tape aviation light, safety arrangement incl. heater assembly as per direction of EIC including Erection & commissioning of 12.5 mtr Highmast on C.C foundation with ratio of 1:2:4 as per design & casting housing of suitable RCC shallow foundation with foundation bolts manufacturing from special steel for highmast after assembling the Highmast. (Make- Bansal / Jindal / Bajaj).
Earthing with 65 mm dia GI pipe (TATA-Medium) x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Supply & fixing 415V 63A TPN Main Switch with HRC fuse on angle iron frame on wall incl. earthing attachment & painting as per GS.
Supply & drawing of 1.1 KV Grade 4 Core 16sq.mm. PVC/A Al cable partly recessed in wall & mending in U.G. trench with brick protection as per GS.
a) In under ground Trench as to GS
b) Recessed in wall as to GS
S & F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry for 4 core 16 sq.mm. PVC/A
Finishing the 4 core 16 sq.mm. PVC/A Al cable ends by soldering with Cable Socket & insulated tapes etc. incl. supply socket soldering materials, tapes etc & making connection
S & F of 172 W LED flood luminaries with pressure die cast Al housing & heat resistant touchend flat glass (IP 65) complete with EMITTER LED (Make-Philips - BVP410 LED 172 CW HE NB FG S3 XT).
Man in and adopting micro tunneling of 50 mm dia hole to facilitate cable entry without disturbing and damaging as per requirement and as per direction of EIC ( 3 ft below the ground level)
Supply and providing (50 mm dia) heavy gauge PVC pipe without any jointing through micro tunneling as permanent solution of longevity of tunnel as per direction of EIC for drawing of road crosing cable.
S & D outdoor type M.S. mini Pillar Box complete with car venture type base pedestal for holding the upper compartment of the Pillar Box. The overall dimension of the above Pillar Box 750 x 500 x 400mm. made from 4mm. thick M.S. sheet with single door for free opening. The above door fitted with side of the Pillar Box by single set hinge system arrangement with providing capsule hinge welded with the Pillar Box rigidly incl. providing door handle and providing vent at the top side of the Pillar Box incl. padlock system on the above Pillar Box for extra protection incl. S & F 7 (seven) lever (Godrej) padlock with duplicate key in front side. There should be provision inside the Pillar Box of 1 No. suitable size of Hylam sheet holding the electrical accessories with suitable size of angle iron frame fitted inside the middle portion of the above Pillar Box and S & F of following accessories.
a) 1 No. 415V 63A TPN SFU with HRC fuses (L&T with sheet steel enclosure) - 1 Set. b) 1 No. 550V 100A BBC (400 x 350 x 150) mm. with 4 nos. Copper bar on porcelain chair including providing following accessories at the top cover of BBC as per direction of EIC - 1 Set. c) S & F Pilot Lamp (R/Y/B). - 3 Nos. d) S & F Suitable size DIN rail for installation of different rated MCB, and S & F suitable rated connector for both phase and neutral on insulator chair and backelite sheet. e) S & F 450 V, 10KA, 40A, TP MCB 'C' curve -1No. Make-(L & T / Legrand / Siemens) f) S & F of suitable rated inter connecting Cu Wire from Busbar to MCB and MCB to Connector with socketing. g) S & F 40A power connector with suitable add on blocks with necessary coneection - 1 No. (Make: L & T / Legrand). h) S & F AC 50 HZ, 3Ph Digital time switch (Make: L & T / Legrand) - 1 No. i) S & F 230V, 10KA, 16A SP MCB 'C' curve Make - (L & T / Legrand / Siemens) - 10 Nos. j) By pass switch - 1 no. Including necessary paintings as per direction of EIC.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, equipments & accessories must conform to relevant IS /IEC specifications. The High Mast Tower & Light fittings to be supplied must be from the OEM/ authorized dealer duly certified by the OEM. (iii) Necessary manufacturer's warranty certificate for High Mast Tower & Light fittings will have to be submitted during delivery of the material. (iv) The High Mast Tower & Light fittings must be warranted not less than 12 months from the date of commissioning.
MONDAL ENTERPRISE
M/S EASTERN ENGINEERING
MITRA ELECTRONICS
ARGHYA BHATTACHARYA
KANJILAL and SONS
stage.html
html • 0.06 MB
technical_532145.pdf
PDF • 0.04 MB
techsummary_532145.pdf
PDF • 0.44 MB
finance_532145.pdf
PDF • 0.05 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_532145.pdf
PDF • 0.08 MB
AOC.pdf
PDF • 0.64 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .