Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹43 LAccepted-AOC NEW NO 5A OLD NO 80 53RD STREET ASHOK NAGAR CHENNAI TAMIL NADU 600083 | CHENNAI | TAMIL NADU | 600083 | 1 | Accepted-AOC Technically complied and quoted value was with in the allotted budget. | |
| 2 | Not Admitted-Fee/PreQual/Technical CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | - | Not Admitted-Fee/PreQual/Technical Others-Bidder not enclosed current AMC. Also not shown experience for the completion of lab animal house for value of not less than 40 Lakhs & one lab animal house with negative pressure for necropsy room.Letter of consent,tender doc not attested by Notary. | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others- Bidder not enclosed the experience, user, solvency certificates current AMC order, details of AC specified in this tender, report for clean room validation, Proof of incorporation, letter of consent, drawing, attested by notary public | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Bidder not enclosed the experience, user, solvency certificates current AMC order, details of AC specified in this tender,report for clean room validation, Proof of incorporation,letter of consent,drawing, attested by notary public tender doc sign. |
Tender Value
₹43 L
EMD Value
₹43,000
Closing Date
21 Jun 2022, 12:30 pmClosed
DEAN, VCRI, ORATHANADU, THANJAVUR
VETERINARY COLLEGE AND RESEARCH INSTITUTE, ORATHANADU, THANJAVUR-614625
As per BOQ
2022_TNVAS_234997_1
65_TANII_VPT_VCRI_OND
Open Tender
Electrical Works
Turn-key
180 days
VCRI, ORATHANADU
REFER AS PER THE TENDER SCHEDULE
7 documents required · 7 mandatory
₹0
₹43,000
14 Sept 2022
6 Jun 2022
22 Jun 2022
6 Jun 2022
21 Jun 2022
6 Jun 2022
Amount
Air handling unit system Double skin Air Handling Unit fabricated from outer skin with 0.63 mm thick pre-coated G.I sheet & plain 0.63 mm thick inner G.I sheet with 40+/-3 mm thick injected PUF insulation with Aluminium extruded frame work having Thermal break profile complete with the following sections:Mixing Chamber, Pre-filter section, Cooling coil section with 6 rows deep cooling coil, 3 micron MicroVee filter section & Carbon Activated Filter Section, Fan section with backward curve Belt Driven with Motor, one standby motor shall be supplied as standby MAKE: Chennai Airtech /AM CleanAir /Luftek Eq.AHU /5800 CFM / 125 mm S.PwG (AC capacity: 16.5TR)
Treated Fresh Air Unit made of double skin fabricated with 0.63 mm thick pre-coated G.I sheet & plain 0.63 mm thick inner GI sheet with 40+/-3 mm thick PUF insulated panel with Aluminium extruded frame work having Thermal break profile complete with8 row deep cooling coil connected to condensing unit, using copper piping and accessories to make the system fully functional with provision for Fresh Air intake provisions, Volume Control Dampers, C channel support from wall / floor Capacity: 2000CFM / 50mm SP wG (AC Capacity: 8TR)
Exhaust AHU: Single Skin AHU made with Nitrile foam insulated PPGI skin of >1mm thick with aluminium structural frames for rigidity complete with HEPA filter Capacity:1600CFM
Ventilation system comprising of Fresh Air and Exhaust system complete with Centrifugal Blowers for supply and exhaust air, 20 micron & 5 micron filters, Starter/ switches for the Blowers etc. for Washing Room, Sterilization Room, Common Store Room. Capacity: 3500cfm
AIR CONDITIONING AIR COOLED CONDENSING UNITS Air cooled condensing unit comprising of Scroll single compressor and air cooled condenser (Refrigerant R 410A or R407C)) Make: Voltas / Blue Star 8.5 TR (AHU) Fixed speed
8 TR (Inverter) (AHU& TFA)
Split ACs for Non-Sterile Rooms ( Incharge Room & Office Room) 1 Ton, 3 star, Inverter AC
Split ACs for Service Corridor 1.5TR, 3 star, Inverter AC
FILTRATION Make: AAF / IMPEC/Aerosol/Swades Prefilters: for particles in the range of 10 microns@ >90% – non-woven fabric, cleanable media with aluminium support mesh; to match AHU & TFA capacity
Fine Filter: for particles in the range of 3 microns @ >90% – non-woven fabric, cleanable media with aluminium support mesh; to match AHU capacity
HEPA filters(High Efficiency Particulate Air) High flow model, to filter 0.3µ and larger particles at >99.97% efficiency installed in the AHU; total capacity >5800cfm
Exhaust HEPA Filter(High Efficiency Particulate Air) High flow model, to filter 0.3µ and larger particles at >99.97% efficiency installed in the Exhaust AHU; total capacity >1600cfm
Activated Carbon Filter to remove odour from the rooms, Size 610 x 610 x 292mm, Capacity: 2000cfm – installed in the AHU
AIR DISTRIBUTION Supply and fixing of G.I. sheet ducts complete with all fitting, accessories, vanes, take offs, canvas connections transformation. The rate shall include suspension and supporting arrangement. (MAKE: JINDAL / TATA) 24 G ( 0.63 mm Thick )
22 G ( 0.80 mm Thick )
INSULATION (MAKE:A-Flex/K-Flex)Supply air duct Nitrile foam insulation with one side aluminium foil faced 13mm
Aluminium cladding for external ducting exposed to direct sun and rain
Dampers & Diffusers Volume Control Dampers GI (20G) with manual operation handle, gradation for opening
Fire Dampers with fusible link with limit switch to switch Off the AHU
Aluminium powder coated Diffuser with GI collar damper
Return Air Risers in the corner of room with PPGI sheet, aluminium Grille & GI collar damper
Clean Room Monitoring Devices Differential Pressure Gauges with Digital display and alarm for pressure deviation including installation in an SS enclosure +60 to -60 Pa (Make: Aerosense/ Dwyer)
Differential Pressure Gauge installed in an SS enclosure (0-60Pa) (Make:Aerosense/ Dwyer)
Temperature & RH display units (Make: Honeywell/Subzero /equivalent)
TESTING,COMMISSIONING & VALIDATION including DQ / IQ / OQ / PQ documentation a .Air Balancing test b. Pressure balancing test c .Temperature & RH test d. Filter integrity test e. Particle count test f. Documentation charges
Electrical Work for HVAC System Supply, installation, testing and commissioning of Control Panel for AHU, TFA Unit & Condensing Units and Exhaust AHU & Ventilation units complete with Contactors, Overload Relays, Single Phasing Preventer, MCB, Isolators etc as required for the above systems
Electrical Strip Heater with contactor 3 KW including Humidistat, Thermostat & wiring
12 hours light / dark automatic control lighting system for animal holding room including wiring
Clean Room Interior work Modular, EPS (TF grade) insulated Clean Room Ceiling Panels (50mm thick) with both sides PPGI (0.5mm) including cutouts, flashing and supports as required
Clean Room Emergency Exit Doors: Metallic powder coated flush doors with View Panels, SS hinges, SS handles, Door closer, drop seal, panic bar etc. Size: 1.0 X 2.1m
3D internal coving at coving corner joints
Clean Room Equipment Air shower Enclosure (Single person) GI powder coated construction complete with Prefilter, HEPA filters, Blowers, Nozzles, Metallic Clean Room Doors, Interlocking of doors, PCB control circuit with blower timer, Emergency stop, Auto/Manual mode, status indicators etc. Inner Size: 1000 X 900 X 1850mm, Outer size: 1700 X 1000 X 2350mm Airflow through each nozzle: 4000 + 5% fpm
Static Passbox GI powder coatedwith SS304base, electro-magnetic interlocked doors, UV light etcMake: Mark Air Size: 24” X 24” X 24”
Tower Module:for Class 10000 upgrade in two critical rooms Capacity 800 CFM –TowerHEPA Filter Size: 48” X 24” X 3” Size: 27 W X 12 D X 7.9” H
Smoke Detector & Alarm system complete with conventional smoke detectors (24Nos), 4 zone conventional Control Panel, wiring (150m) Manual call point (2Nos),Flashing cum sounder (2Nos), Response Indicator (8Nos)
Garment Storage Cabinet:to store upto 5 overcoats Inner size: 16” X 16” X 48” ht, Outer size: 18” X 18” X 60” ht complete with HEPA filter, Prefilter, Blower, UV lamp, LED lamp, Aluminium Glass door, GI powder coated construction (Optional)
Cross over Bench: Fully SS304 construction with shoe rack beneath the bench Approx Size: 7’ X 1’ X 1¼ (to suit Change Room width) (Optional)
Wall coating for Animal Rooms(critical) with anti-fungal PU based non-VOC paint after putty (Primer + 2 coat finish) -Color– white (Optional)
Wall coating for non-critical rooms with Commercial Emulsion paint (Primer, Putty + 2 coats finish paint) – Color of your choice from shade card (Optional)
CCTV complete with 8 Channel, HD DVR, 1 SATA HDD, 12V DC & Indoor, 2MP HD Dome Camera (6 Nos.) with power supply, DAHUA Make; 1TB Surveillance Hard Disk, 24” LED Samsung Monitor 3+1 cable with conduit (up to 150RM) 18 Cameras (Optional)
Biometric entry system (Optional)
Coving R50 extruded aluminium covings for the entirewall to ceiling joints (Optional)
Additional extended warranty with validation for HVAC system and clean roon equipments (passbox , air shower etc. ) -one more year after the standrad warranty period of 12 months from commissioning and hand over
Annual Maintenance Contract per year
Comprehensive Annual Maintenance Contract per year
Bidder Name
Mark Air-Particulate control systems
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .