Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.6 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹33.6 L+₹6.3 L (23.1%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹40.6 L+₹13.3 L (48.6%)Rejected-Finance | L-3 | Rejected-Finance L-3 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
21 Jun 2023, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR TO ROLLING SHUTTERS, GATES, ROOF TRUSS, FLOORING, PLASTERING AND CERTAIN E/M WORKS AT AF STN FARIDABAD IN AOR OF GE (AF) FARIDABAD (2ND CALL)
2023_MES_593798_2
GE (FBD)/AF-13/2023-2024
Open Tender
Civil Works
Item Rate
180 days
Faridabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹96,000
Yes
4 Aug 2023
7 Jun 2023
23 Jun 2023
7 Jun 2023
21 Jun 2023
7 Jun 2023
Amount
Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and directed by Engineer-in-Charge.
Rendering, 15 mm thick, in cement mortar 1:6, over brick or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound conforming to IS-2645-1975 complete all as specified and directed by Engineer-in-Charge.
Rendering,15 mm thick, in cement mortar 1:4 over brick or concrete surfaces, finished fair and even without using extra cement, mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge. Note:-Integral water proofing compound shall be measured and paid separately
M & L 10mm thick rendering in ceilings in CM(1:3) finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for preparing New plastered surfaces and applying two coats of distemper oil emulsion on wall surfaces including chalk whitening preparatory to distempering complete all as specified and directed by Engineer-in-Charge.
M & L preparation of new plastered surfaces on walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M & L preparation of new plastered surfaces on ceilings & M & L for applying three coats ofd white wash complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing) and disposal of debris complete all as specified and directed by Engineer-in-Charge.
Providing plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregates, 25mm thick, as in floor/sub base and finishing concrete surface fair and even to receive top floor finishes complete all as specified and directed by Engineer-in-Charge.
Providing screed bed or bedding layer, 15 mm thick, in cement mortar 1:6 for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
Rendering, 10 mm thick, in cement mortar 1:4, on wall surafaces, as backing coat to tiles complete all as specified and directed by Engineer-in-Charge.
Glazed ceramic tiles, 300/350 x 450 x 7mm thick, glossy finish, conforming to Group B-III of IS-13712, first quality, of approved colour, laid on vertical surfaces such as skirting or dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
Non skid ceramic coloured plain tiles,300 x 300 x 7mm thick, conforming to Group B-IIA of IS-13712, first quality, laid in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M&L for coloured Non Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M&L for light shade vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M&L for light shade vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exc 0.42 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
M&L for Granite 20 mm thick (of any type ) (table runned and polished ) in floors steps , jamns, pillars,window-cills,cooking plateforms and vertical surfaces bedded and jointed with grey cement slurry and pointing in white ciment (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
M&L rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing 75mm thick PCC (1:3:6) type C1 using 40 mm graded aggregate as Plinth protection / Path finished/ backyard floor /parking floor the surface even & smooth with out using extra cement complete all as specified and directed by Engineer-in-Charge.
Cleaning &removal all scales & dirt etc, from tanks & from mouths of circulating pipe etc exc 500 but n.exc 1000 ltrs capacity complete all as specified and directed by Engineer-in-Charge.
Cleaning &removal all scales & dirt etc, from tanks & from mouths of circulating pipe etc exc 250 but n.exc 500 ltrs capacity complete all as specified and directed by Engineer-in-Charge.
Vitreous china squatting pan of orissa pattern, size 580 x 440 mm, white, with 'P' or 'S' trap, with integral foot rest, including demolition and removal of existing old pan complete all as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous china wash down water closet, pedestal pattern (EWC), white, with 'P' or 'S' trap, with PVC water closet seat, black or white, closed pattern, with flat bottom and cover and mild steel chromium plated or aluminised hinging device including taking down and removal of existing old water closet with scat cover complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel/PVC tubing and connections,15/20 mm bore, and making good the surfaces complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stainless steel Harrison curtain rails, 19/20mm dia, including stainless steel brackets and fixing brackets, stops, rollers etc including taking down old one complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge.
S & F in repair Stainless steel plate rack (bartan stand) made with 4-5 mm dia stainless steel rods of minimum 750mmx250mmx750mm size complete all as specified and directed by Engineer-in-Charge.
M&L for welding repair works at small patches like hinges, door closer, window repair, steel door/gate fittings like hinge, bolts, bars etc complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement, 75mm diameter of outlet, complete all as specified and directed by Engineer-in-Charge.
M&L for PVC (SWR) pipes, 75 mm bore, single socketed, in any length, with rubber ring joints, fixed to wall complete all as specified and directed by Engineer-in-Charge.
M&L for PVC (SWR) pipes, 100/110 mm bore, single socketed, in any length, with rubber ring joints, fixed to wall complete all as specified and directed by Engineer-in-Charge.
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F in repair and providing PVDF aluminum comosite panels with fire resistent mineral filled core material shall consist of following :- (i) Aluminum sheet making a total panel thickness of 6 mm with outer surface finished with PVDF based coating 0.25mm, inner surface finished with a thin coat of polyster paint. The cleaness of aluminum cover sheet shall be 0.50mm inner core shall be of LDPE. (ii) Aluminum framing of section 25mm x 50mm x1.50mm thick. (iii) Aluminum grid shall not be exceed 1.0 Sqm each the aluminum grid not more than 1 m c/c shall be fixed with MS angle 30x30x5 mm projected 150mm from surface of wall. (iv) Colour shall be approved of GE. (v) Joint shall be sealed with help of masking Tapes complete all as specified and directed by Engineer-in-Charge. Note : Canopy , borders, projections etc will be measured in sqm for payment purpose.
M&L for cut outs/metal sign board as per site requirement of size n.ex 3.00 Sqm each PVDF aluminum composite panels with fire resistent mineral filled core material printed with vinay/OR print with 3M retro reflective tapes on ACP sheet fixed on the ACP Sheet with the help of high bond double side laps of 3 M Grey VHB taps 2mm thick complete all as specified and directed. Note : - Colour and type of dogs choice shall complete all as specified and directed by Engineer-in-Charge.
M&L for 3d stainless steel LED lighted letters OR print with 3M retro refelective tapes on ACP Shjeet above 12 inch complete all as specified and directed by Engineer-in-Charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete ground floor and paving nexc 15cm thick (below or above ground level ) complete all as specified and directed by Engineer-in-Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concretebut excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
S&F 1.25mm thick Steel rolling shutters, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type incl taking down rolling shutters complete all as specified and directed by Engineer-in-Charge.
S&F Safety lever locks mild steel with 4 levers incl ball bearing for rolling shutters complete all as specified and directed by Engineer-in-Charge.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engineer-in-Charge.
Welding in repairs n. exc 2.5cm in length and thickness of metal to be welded exc 6mm but not exceeding 9mm complete all as specified and directed by Engineer-in-Charge.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
M&L for repairs to steel gate/Wicket gate of sliding door bolt, hinges, pintel, locking arrangment, spike, V groove/Flat edge heavy duty gate roller, roller rails etc including gressing, welding /reveting to bring the steel gate /wicket gate in service condtions etc complete all as specified and directed by Engineer-in-Charge.
S & F for mild steel framed work as in grill, guard bars etc with ends of bars/FI shoulders and or riveted or forged in to spikes, framed guard bar and similar works confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
Taking down existing steel rolling shutters size not exceeding 2.50m x 3.00m with all connecting items and repair/replace the lath of steel rolling shutters and locking arrangements, greasing, tightening of helical wire spring including welding wherever required, oiling, etc. complete to make in serviceable condition and applying two coat of synthetic enamel paint including preparation of old painted surfaces and refixing in the same opening complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Lath of steel rolling shutters, lock plate with locking arrangement and bow handles shall be measured and paid for separately. (ii) Spring shall be included in the rate of item (iii) Supply only unserviceable items shall be measured and paid separately under respective items.
All as per serial item No. 53 above but size 3.50m x 4.50m complete all as specified and directed by Engineer-in-Charge.
Supply only lath of rolling shutter (thickness of lath 1.25 mm) complete all as specified and directed by Engineer-in-Charge.
Supply only prefabricated lock plate length not less than 2.20m and not more than 4.00m and width not less than 0.15m and not more than 0.20m of riveted construction made out of mild steel sheet 3.15mm thick, reinforced with mild steel angle 35 x 35 x 5mm size at bottom and locking arrangement with two bow handles and flat iron 25 x 3mm to fix the lath and lock plate complete all as specified & directed by Engineer-in-Charge.
Taking down carefully the existing serviceable steel door made out of MS angle iron frame with steel sheeting and refixing the same door on same location after carrying out the other repair work under the relevant items of this Schedule 'A' complete all as specified and directed by Engineer-in-Charge.
S & F for rolled sections as in main and cross beams, hip and jack rafters,truss, purlins where connected to common rafters and running rails, cleat or other connecting plates cutting, welding including Nut Bolts, Fe 410-W(Gde -E-250) quality A complete all as specified and directed by Engineer-in-Charge.
S&F mild steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St-240 complete all as specified and directed by Engineer-in-Charge.
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., incl welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI vased corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI vased Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in sub base complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning for laying of inter locking tiles (paving blocks) complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm tickness , M-35 grade, set, jointed and pointed in neat cement slurry in floors with grey cement & pigments all as directed by Engineer-in-Charge.
M&L Chequered cement concrete tiles20cmx20cmx25mm thick, set jointed and pointe in neat cement slurry with grey cement and pigment over and including 15mm thick screed bed in CM 1:6. complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in side of path / benching / coved fillets etc rounded or chamfered on edges complete all as specified and directed by Engineer-in-Charge.
M & L 75mm th PCC 1:3:6 type C-2 as in plinth protection, finished even and fair complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall/ceilling over one coat of primer incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new plasterd surfaces and applying two coats of weather coat/exterior emulsion paint of electric blue/white or AF blue colour or equivalent colour as approved by GE,using ultra clean paint of Dulux ICI or Apex ultima of Asian paints or equivalent in berger paints over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
Taking Down carefully Copper/aluminium Point Wiring (light, fan,socket or Power) complete,(fittings Such as switches, ceiling roses, pendents, regulators sockets etc, to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer-in-Charge.
Taking Down carefully Copper/aluminium Point Wiring 4.0 sq mm ,removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper / aluminum two core sub main wiring of sizes 1.5 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper / aluminum two core sub main wiring of sizes 4/6 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring in repairs complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of 2 mm thick pressed steel terminal box of suitable size with 3 mm thick hylam laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) cocomplete all as specified and directed by Engineer-in-Charge for following (Color coding to be followed) :-
All as per Item No 78 mentioned here-in- before but one three pin 5 Amps socket out let on the same board with other switches with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engineer-in-Charge.
All as per item No 78 mentioned here-in- before but one three pin 5 Amps socket out let on independant board with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engineer-in-Charge.
All as per item No 78 mentioned here-in- before but 15 Amps 3 pin socket outlet on independent board with 2.5 sq mm PVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engineer-in-Charge.
All as per item No 78 mentioned here-in- before but for Single pole and neutral enclosure with 4.0 sq mm PVC insulated and sheathed copper conductor with 4 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engineer-in-Charge.
S&F Piano switch in repairs, flush button,single pole,one way 5/6 Amp complete all as specified and directed by Engineer-in-Charge.
S&F piano switch,in repairs, flush button single pole one way 15/16 Amp complete all as specified and directed by Engineer-in-Charge.
S&F bell push, in repairs, flush type 5 Amps complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, in repairs,flush type 2 in 1, 2 pin and 3 pin 5 Amp complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, in repairs,flush type 2 in 1, 3 pin and 6/16 Amp complete all as specified and directed by Engineer-in-Charge.
S&F stepped type electronic fan regulator, in repairs, flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,ceiling rose surface backlight, 65 x 50 mm two to to three terminals complete all as specified and directed by Engineer-in-Charge.
S & F in repairs Bell Multi Music type,240 V complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete all as specified and directed by Engineer-in-Charge. Make - As per sample
Supply and fix Modular switch 2 way 6A, 1 module type, 230 volts, ISI marked complete all as specified and directed by Engineer-in-Charge. Make - As per sample
Supply and fix Modular Bell push 6A 1 module type, 230 volts, ISI marked complete all as specified and directed by Engineer-in-Charge. Make - As per sample
S & F Modular stepped type electronic fan regulator 2 Module, on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge.. Make - As per sample
Supply and fix Socket, 6A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and directed by Engineer-in-Charge. Make - As per sample
Supply and fix Socket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and directed by Engineer-in-Charge. Make - As per sample
Supply and fix Modular switch 1 way 16A, 1 module, multipurpose flush type, ISI marked complete all as specified and directed by Engineer-in-Charge. Make - As per sample
Supply and fix 8" x 6" hylem sheet 3 mm thick ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply and fix 7" x 4" hylem sheet 3 mm thick ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply and fix 4" x 4" hylem sheet 3 mm thick ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply and fix Switch flame proof rotary Type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-Charge.
Suppply and fix flame proof switch socket & plug combined in LM 6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed by Engineer-in-Charge.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 1 module ISI marked complete all as specified and directed by Engineer-in-Charge.Make - As per sample
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 2 module ISI marked complete all as specified and directed by Engineer-in-Charge. Make - As per sample
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 3 module ISI marked complete all as specified and directed by Engineer-in-Charge. Make - As per sample
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 4 module ISI marked complete all as specified and directed by Engineer-in-Charge.Make - As per sample
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 6 module ISI marked complete all as specified and directed by Engineer-in-Charge. Make - As per sample
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 8 module ISI marked complete all as specified and directed by Engineer-in-Charge.Make - As per sample
Supply and fix MODULAR METAL FLUSH BOX 3 module ISI marked complete all as specified and directed by Engineer-in-Charge. Make - As per sample
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 4"x4" complete all as specified and directed by Engineer-in-Charge.
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 7"x4" complete all as specified and directed by Engineer-in-Charge.
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 8"x10" complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,sheet metal enclosure for MCB DB's SPN 240 volts, 4 way with neutral bus bar 200 Amp rated double door type regal grey complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,sheet metal enclosure for MCB DB's SPN 240 volts, 8 way with neutral bus bar 200 Amp rated double door type regal grey complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 114 here in above but 12 ways DBs complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 114 here in above but TPN DB, 4 ways DBs complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,Single pole and neutral enclosure with a two pin and earth plug and socketcomplete with one single pole MCB 32 Amp complete all as specified and directed by Engineer-in-Charge.
M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 1.5 Sqmm duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 1.5 Sqmm size and connecting to common earth dollycomplete all as specified and directed by Engineer-in-Charge.(Flexible Copper Wire Used In FRLS)
M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 6 Sqmm duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 6 Sqmm size and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge..(Flexible Copper Wire Used In FRLS)
All as per item No 119 mentioned here-in- before but 4.0 sq mm PVC insulated and sheathed copper conductor with 4 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB SP 6 to 32 Amps 240 Volts."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB,SP 40 Amps, 240 Volts."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB,SPN 6-32 Amps, 240Volts,"B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB SPN, 40 Amps, 240Volts ."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB SPN, 63 Amps, 240Volts."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB TPN 40 Amps,415Volts ."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB TPN, 63 Amps,415Volts ."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,LED tube light batten 22W LED,6000K (4 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,LED tube light batten,12W(+) 2% LED 6000K (2 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,LED false ceiling panel fittings ,1x45W/1x40W LED 6000K (2ftx2ft.), 230 volts AC,suitable for false ceiling, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engineer-in-Charge. Make - Polycab/Crompton/Havells.
Supply and fixing LED Lamp 20 Watts with suitable to replace 36/40 Watts FTL,high Efficiency PMMA diffuser soft glare free light complete and including provision of three core textile braided copper conductor flexible wire from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge. Make- CG model No :LTT8-20 or equivalent to in Philips/Ledvance/Wipro.
S & F Electronic drivers suitable to fix Recessed mounted LED Light Fitting 2'x2' 40Watt 6000 K/5400K complete make and model all as requred on site for smooth functioning of lights complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan complete any type size from existing location and cleaning body blades etc including greasing,oiling,replacing wornout bearing ,bush and refixing the same at site complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No. 133 here in above but for Exhaust fan 300 mm sweep complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 113 here in above but for Exhaust fan 450 mm sweep complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 113 here in above but for wall/floor mounted fan 450 mm sweep complete all as specified and directed by Engineer-in-Charge.
Rewinding unserviceable ceiling fan 1200/1400 mm Sweep from site by strip opening,cutting removing the burnt winding from starter cleaning the slots and rewind the same with original guage of super enameled copper winding wire, insulation materials and all accessories & varnishing etc replacement of service wire copper twisted size 23/0.0076 including reassembling the fan complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 137 here in above but for Exhaust fan 300 mm sweep complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 137 here in above but for Exhaust fan 450 mm sweep complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 137 here in above but for wall/floor mounted fan 450 mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Capacitor 2.5 mfd suitable for Ceiling Fan/Wall fan/Exhaust Fan complete all as specified and directed by Engineer-in-Charge. Make :-Universal / Havells / Sarda
S&F in repairs Capacitor 3.15 mfd suitable for Ceiling Fan/Wall fan/Exhaust Fan complete all as specified and directed by Engineer-in-Charge. Make :-Universal / Havells / Sarda
S&F in repairs Capacitor 4.0 mfd suitable for Ceiling Fan/Wall fan/Exhaust Fan complete all as specified and directed by Engineer-in-Charge. Make :-Universal / Havells / Sarda
Supply only ball bearing for 1200/1400mm sweep Make;- TATA / SKF/NBC complete all as specified and directed by Engineer-in-Charge.
Supply only FR PVC electrical insulation tape,1.8 cm x 25 mtr x0.125 mm thick complete all as specified and directed by Engineer-in-Charge. Make: Anchor/Steelgrip/Pidlite.
S&F ceiling fan down rod 15 mm bore 45 cm long including cutting and threading suitable for hanging of ceiling fan 1200mm/1400mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F ceiling fan down rod 15 mm bore 2 mtr long including cutting and threading suitable for hanging of ceiling fan 1200mm/1400mm sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fix Ventilation fan PVC (250 mm Sweep) with louvers and acessories complete all as specified and directed by Engineer-in-Charge. Make: Standard Model No. Refresh air-DX or equivalent to Havells/USHA
Supply and fix Ventilation fan PVC (200 mm Sweep) with louvers and acessories complete all as specified and directed by Engineer-in-Charge. Make: Standard Model No. Refresh air-DX or equivalent to Havells/USHA
MAA BHAWANI CONSTRUCTION
MAHABIR SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .