| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.7 L+₹3.5 L (9.77%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹41.4 L+₹5.2 L (14.4%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
17 Sept 2024, 6:00 pmClosed
GE CENTRAL BANGALORE
SC CENTRE AND COLLEGE AGRAM POST BANGALORE 560007
REPAIRS REPLACEMENT OF CEILING EXHAUST FANS HOT WATER SYSTEM WITH CONNECTED WORKS SUMMER APPLIANCES AND WATER COOLERS DEEP FREEZER ACs REFRIGERATORS ETC UNDER GE C BANGALORE
2024_MES_666783_1
8407E
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE CENTRAL BANGALORE
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE CENTRAL BANGALORE
₹94,000
Yes
24 Oct 2024
19 Jul 2024
19 Sept 2024
19 Jul 2024
17 Sept 2024
29 Jul 2024
19 Jul 2024 - 27 Jul 2024
Amount
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc.
Point Wiring with 1.5 Sqmm (Nominal Area) PVC insulated unsheathed 1100 Volts Grade Stranded Copper Conductor Cable (Red Colour Cable for Phase and Black Colour Cable for Neutral), laid in and including PVC Casing and Capping with Accessories (size of Casing and Capping as required at Site) including 1.50 Sqmm PVC ins-ulated Stranded Copper Conductor Cable (Green Colour) as Earth Continuity Conductor and connected to Common Earth Dolly or as directed and MS terminal box with 3mm thick masonite laminated sheet top cover fixed on Wall for one light and fan point controlled by one switch complete all as specified and as directed for One light /fan point controlled by one 5 Amps switch one way
All same as per item No 2 here-in-above but One 3 pin socket point 5 Amp on independent board
All same as per item No 2 here-in-above but One 3 pin socket point 5 Amp on same board with other switches.
All same as per item No 2 here-in-above but with 2.5 sqmm ( Nominal area ) cable with 2.5 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
M&L, Switch piano, flush button single pole, 5 Amps one way
S&F Switch socket combination flush type 5 Amp 2 in 1
S&F Switch socket combination flush type 5/16 Amps5 in 1
Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC square blocks.
S&F in replacement of sheet metal enslosure single pole and neutral with a two pin & earth plug and socket complete with 1 single pole MCB 20 Amps 'C' series 10 KA breaking complete all as specified and directed. Make- Legrend/Standard/Havells.
S&F in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SP 8 way horizontal type, Double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete and old MCB DBs Deposit to store with all as directed.
S & F in replacement MCB single pole 6-32 Amps 240 volts, 10 kA rupturing capacity providing in DB complete e with all as specified and directed by Engr-in-charge. Make Indoasian
S & Fin replacement MCB single pole & neutral 40 Amps 240 volts, 10 kA rupturing capacity providing in DB complete all as specified. Make Indoasian
S & Fin replacement indurstrial socket with MCB 32 A FP with enclouser 415 volts, 10 kA rupturing capacity complete all as specified. Make Indoasian
S & Fin replacement 30W LED 4x1 ft white,surface mouted LED luminire with polymer duffiser complete assccessories suitable armstorm/grid ceilling with inernal prewired and connecting twin core twisted flexible copper wire all as specified. Make Indoasian
S & Fin replacement 30W LED 4x1 ft white,recess mouted LED luminire with polymer duffiser complete assccessories suitable armstorm/grid ceilling with inernal prewired and connecting twin core twisted flexible copper wire all as specified. Make Indoasian
S & Fin replacement 24W LED 1x2 ft white,recess mouted LED luminire with polymer duffiser complete assccessories suitable armstorm/grid ceilling with inernal prewired and connecting twin core twisted flexible copper wire all as specified. Make Indoasian
Supply ony PVC Casing & caping 25X1800mm
Supply ony PVC Casing & caping 20X1800mm
Supply only 2.5sqmm copper,FRLS (Nominal Area) PVC insulated unsheathed 1100 Volts Grade Stranded Copper Conductor Cable
Supply only 1.5sqmm copper,FRLS (Nominal Area) PVC insulated unsheathed 1100 Volts Grade Stranded Copper Conductor Cable
Supply only 4 sqmm copper,FRLS (Nominal Area) PVC insulated unsheathed 1100 Volts Grade Stranded Copper Conductor Cable
Supply only PVC plain board of size 4 x 4 inch
Supply only PVC plain board of size 7 x 4 inch
Supply only PVC plain board of size 11 x 7 inch
Supply only PVC plain board of size 8 x 4 inch
S&F in replacement of metal clad plug top protected type 20 Amps 230 volts complete all as specified and directed. Make-Std/Havells/Bajaj
S&F LED tube light fitting Mirror type ,2 Feet of 10 watts , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with wall mounting all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Shakti/Crompton Greaves/Bajaj
S&F in replacement LED tube light fitting of 20 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with wall mounting all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm with all as specified and directed by Engr-in-charge. Make : Shakti/Crompton Greaves/Bajaj
Taking down old existing sub main wiring and provide new submain wiring with 2 runs of 6 Sqmm single core PVC insulated, unsheathed, multi stranded copper conductor and one single core 6 Sqmm PVC insulated , unsheathed , multi stranded copper cable as earthing lead as per IS : 694 / 1990 drawn through and including non-metallic PVC rigid conduit/casing caping of size as ordered in walls / ceilings etc with all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note :- 2 runs 6 Sqmm cable , one run 6 Sqmm cable and one run of PVC Conduit /Casing caping shall be measured as one unit length) .
All as per item No 30 here-in-above but 2 runs with 4 Sqmm single core cable and 4 Sqmm single core as earth contunity wire -do- . (Note :- 2 runs 4 Sqmm cable , one run 4 Sqmm cable and one run of PVC Conduit/Casing caping shall be measured as one unit length)
All as per item No 30 here-in-above but 2 runs with 2.5 Sqmm single core cable and 2.5 Sqmm single core as earth contunity wire -do- . (Note :- 2 runs 2.5 Sqmm cable , one run 2.5 Sqmm cable and one run of PVC Conduit/Casing caping shall be measured as one unit length)
Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) , including connecting with three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of the ceiling fan , making necessary connection & testing on completion all as directed.
Supply & Fix in replacement flexible cord copper conductor of size 23/ 0.0076 twisted twin core for connection to fan from ceiling rose, complete all as specified and directed.
REPAIR TO CEILING FAN : Taking down ceiling/exhaust fan dismantling and painting of ceiling/exhaust fan complete at site with synthetic enamel paint by spraying incl (fittings with filler) one coat after cleaning all dust etc incl connecting up. Provn of twin core cable of suitable size for ceiling rose to connector connecting of earth wire incl replacement of fan capacitor 2.5/3.15 MFD,canopy, bearing/bush, rubber bushes minor nuts bolts screws washers greassing in fan bearing & refix same complete all as directed
Rewinding of ceiling fan 1200/1400mm sweep with super enameled copper wire of existing specification, guage and weight including insulating material all as directed by Engr-in-Charge
Supply & fix in replacement fan capacitor 2.5 MFD including necessary connection all as directed.
Supply & fix in replacement ball bearing ceiling fan 1200mm/1400mm sweep including necessary greasing all as directed by Engr-in-Charge. Existing make
Supply & fix in replacement gun metal bush of existing size suitable for 1200/1400mm.
Supply & Fix in replacement U clamp with rubber reel insulator with nuts bolts of size 10mm dia 75mm long including necessary washer and split pin.
Supply & Fix in replacement ceiling fan hook any shape&size including nuts, bolts and rubber reel. angle,
M&L for overhauling of ceiling fan of any make and sweep including dismantling, cleaning internally and externally and oiling, greasing, checking of electric connection.Replacement of worn out check nuts, split pins, nut,bolts,washers, socketsfan capacitor 2.5/3.15 MFDand etc including two coats of painting , assembling and testing complete all as specified and directed.
REPAIR TO EXHAUST FAN : Rewinding motor of exhaust fan 450 to 200 mm sweep with supr enamelled copper wire of existing specification, guage and weight including insulating material all as directed by Engr-in-Charge.
Supply & fix in replacement ball bearing of existing exhaust fan suitable for 450 to 200 mm sweep including necessary greasing all as directed. Make : SKF/NBC/Norma
S&F in replacement of Exhaust fan metal body 450mm sweep, star, 240V 1500 RPM all as specified and directed
S&F in replacement of Exhaust fan metal body 225/300mm sweep, star,240V 1500RPMall as specified and directed
S&F in replacement of Exhaust fan PVC body 200mm sweep, star, 240V 1500 RPM all as specified and directed
S&F in replacement of Exhaust fan PVC body 150mm sweep, star,240V 1500 RPM all as specified and directed
S&F in replacement of inderstrial wall mounted fan ,heavy duty 600mm sweep, 1500 RPM , metal body body 240V all as specified and directed
Supply & fix in replacement mounting legs with rubber suitable for any type of exhaust fan.
REPAIR TO GEYSER :Taking down of storage water heater any capacity, type any, make (Geyser) of any size 50/35/25 ltrs capacity from existing position by disconnecting from water supply pipe line and electric connection mains to carryout necessary repairs or to deposit to E/M store yard as directed including refixing on same position after repair and making electric/water connections complete all as specified and directed by Engineer-in-Charge.
M&L for opening of storage water heater any size/make and taking out inner tank from the geyser body brazing inner tank with suitable welding rod, testing of inner tank for leakage under water pressure after brazing, reassembling geyser including repair/replacement of worn out rubber gasket nuts,bolts and testing complete and refixing in original position as specified and directed by Engr-in-Charge.
S&F in replacement 2 KW, 230 volts AC of Heating element for geyser any capacity, type any make(Round head / Triangular head type (,Big, small,Medum )as per site requirements ) including rubber gasket/washer (ISI marked) complete as specified and as directed. Make: All Models of Bajaj l / Havells /Racold / venus / shakthi .Note : As per at site requirement.
S&F in replacement 1.5 KW, 230 volts AC of Heating element for geyser (Round head/Triangular head type (,Big, small,Medum ) as per site requirement ) including rubber gasket/washer (ISI marked) complete as specified and as directed. Make: All Models of Bajaj l / Havells /Racold / venus / shakthi .Note : As per at site requirement.
S&F geyser packing rubber for fixing inlet and outlet complete all as specified and directed.
S&F in replacement of stud bolt with nuts and washers set of three by brazing on inner tank of geyser complete all as specified and directed.
S&F in replacement of Thermostat/auto cut off chromium plated suitable for existing make as per site requirement designed to controlling the temperature of storage water heater(Geyser) to any type single phase 230 V all as specified .
S&F in replacment of indicator lamp red and green (round/rectangular shape )suitable for any type & any size of geysers complete all as speified and directed.
S&F in replacement of 450 to 600 mm long PVC connection pipe for HOT & COLD water supply with chromium plated brass screwed nuts at bolt ends with washers for making water connections for storage water heater(Geyser) to GI pipe 15mm complete as directed .
S&F in replacement of 600 to 900 mm long PVC connection pipe for HOT & COLD water supply with chromium plated brass screwed nuts at bolt ends with washers for making water connections for storage water heater(Geyser) to GI pipe 15mm complete as directed .
Supply & replacement of existing u/s bottom cover of the geyser in two halfs.
Supply & replacement of GI hexagonal nipple 15mm long 15mm dia.
Supply & fix in replacement Plug top 3 pin 15 Amps ISI marked. Make- Anchor/KONA/Kinjal/Plaza
Supply and fix in replacement hanger bolt 100mm long and 12mm dia for mounting of geyser
Remove the unserviceable cooling appliances from the position, transportation only from the site/store to the contractor work shop for replacement of compressor, cooling coil & painting and repair work and refixing the same after repair at the same location all as per direction of Engr-in-Charge for the following :-Window type AC upto 2.0 Ton capacity.
All same as per item No 65 here-in-above but Split type AC upto 2.0 Ton capacity.
All same as per item No 65 here-in-above but Water cooler upto 150 ltrs capacity.
All same as per item No 65 here-in-above but Refrigerator upto 400 ltrs capacity.
All same as per item No 65 here-in-above but Deep Freezer upto 400 ltrs capacity.
Disconnect the suction and discharge refrigerant line to the unserviceable compressor, and replace with the new one compressor brough from the factory of the same make and capacity, connect the refrigerant lines, system fusing, vacummising of the entire system arrest all leakages incl M&L charging of required quantity of refrigerant gas adjusting all connected parts, testing and commissioning for Window/Split type AC upto 2 ton capacity.
All same as per item No 70 here-in-above but Water cooler 150 ltrs capacity
All same as per item No 70 here-in-above but Water cooler 60/120 Ltrs capacity
All same as per item No 70 here-in-above but Water cooler 40/80 Ltrs capacity
All same as per item No 70 here-in-above but Refrigerator 310/320 Ltrs capacity
All same as per item No 70 here-in-above but Refrigerator 200/280 Ltrs capacity
All same as per item No 70 here-in-above but Refrigerator 180/185 Ltrs capacity
All same as per item No 70 here-in-above but Deep Freezer 205/320 Ltrs capacity
Removing and replacement of blower motor/fan motor of the same make and capacity, connection and testing etc all as per specified and directed for Window type AC upto 1.5 Ton capacity
All same as per item No 78 here-in-above but Split type AC upto 2 ton capacity
All same as per item No 78 here-in-above but Water cooler upto 120/150 Ltrs capacity
All same as per item No 78 here-in-above but Water cooler upto 40/80 Ltrs capacity
Servicing and maintenance of window type AC/Split AC including compressed air wash, rearranging of wires, studs or evaporator washing to condenor cooling coil/evoporator cooling coil. Air filter, front grill and make the system functional
Removing the UNSV running capacitor of 40 MFD, supply and fix of running capacitor 40 MFD suitable for 1.5 ton AC make : BHEL or equivalent.
All as per item No 84 here-in-before, but starting capacitor of 60/80 MFD for water cooler
All as per item No 84 here-in-before, but starting capacitor of 80/100 MFD for 1.5 TR/2.0 TR AC.
S & F in replacement of unserviceable thermostate from the cooling appliances Window type AC/Split type AC upto 2.0 Ton capacity
All same as per item No 88 here-in-above but Water cooler upto 150 Ltrs capacity
All same as per item No 88 here-in-above but Refrigerator upto 310/320 Ltrs capacity
Dismantle the unserviceable condenser coil, replace new condenser cooling coil for cooling appliances including system fusing vacumising and M&L of gas and charging testing and commissioning as directed for Window type AC upto 1.5 Ton capacity
All same as per item No 91 here-in-above but Refrigerator upto 310/320 Ltrs capacity
All same as per item No 91 here-in-above but Deep freezer upto 205/320 Ltrs capacity
Taking down the unserviceable fan blade from the condenser cooling motor replace new fan blade of same and type for Water cooler any type
All same as per item No 93 here-in-above but Window type AC any type
Remove unserviceable relay box any type and capacity from refrigerator and supply and fix new relay of same make & type
Servicing/maintenance (at site) of the refrigerator checking complete wires, reconnect cleaning with compressed air to cooling coils, condenser water wash to the internal cabin of refrigerator all as directed by Engineer-in-Charge
All same as per item No 96 here-in-above but for water coolers any size any type .
All same as per item No 96 here-in-above but for Deep Freezer any size any type.
S & F in replacement of push tap of same make & type chromium plated
S & F in replacement of unserviceable float valve of any make 15mm dia
S & F in replacement of unsericeable PVC flexible pipe inlet 16mm outer dia and 450 mm long with brass nuts & bolts
S & F in replacement of plug top 16 Amps suitable for water coolers/Refrigerator /Deep Freezer
Removing and replacement of unserviceable supply cable to the cooling appliances PVC insulated 3 core cable 1.5 sqm multi stranded copper conductor
Material and labour for body repairs by fabrication and painting to cooling appliances incl prepared with two coats of synthetic enamel over a coat of primer after scraping and rubbing the old painted surface all as specified and directed forWater cooler 150 Ltrs capacity
Material and labour for body repairs by fabrication and painting to cooling appliances incl prepared with two coats of synthetic enamel over a coat of primer after scraping and rubbing the old painted surface all as specified and directed forWater cooler 40/80 Ltrs capacity
Material and labour for body repairs by fabrication and painting to cooling appliances incl prepared with two coats of synthetic enamel over a coat of primer after scraping and rubbing the old painted surface all as specified and directed forDeep freezer upto 320/400 Ltrs capacity
Remove and replacement of unserviceable thermostat for refrigerator/deep freezer
Remove and repalcement of unserviceable freezer complete incl M&L of gas charging etc complete all as specified and directed
Remove and replacement of over load protection relay for any type of refrigerator/window AC/Split Each AC/Deep Freezer
Supply and fill R-134 in cylinder for domestic cooling appliance.
Removing the UNSV voltage stabilizer from position, open the outer covers, removing the burnt out winding from the transformer and rewinding with super quality insulated copper winding wire of suitable size and insulating properly incl replacement of boost buck relays, assembling the stabilizer complete and fixing back in original position and testing and commissioning for 1 KVA capacitiy :-
All same as per item No 111 here-in-above but 2 KVA
All same as per item No 111 here-in-above but 3 KVA
Taking out the UNSV sensor/remote unit completely and supply and fix in sensor arrangement/remote unit to suit the following makes carrier/Blue star/voltas for 1.5 Ton Split type AC :-
All same as per item No 114 here-in-above but 2.0 Ton Split type AC.
Removing the damaged/unserviceable refrigerator magnetic gasket of door and replacing with new door gasket of same type and size incl making good the surfaces for proper sealing of the door for 165/286 ltrs capacity.
All same as per item No 117 here-in-above but 286/310 ltrs capacity.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cmx6.3 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connecting with steel GI earth wire 4mm dia by means of bolt nut check nuts and washers including PCC pit with 1:2:4 type B-1 using 20mm graded stone aggregate and frame cover of angle iron 25x25x6mm, MS sheet 3mm thick, and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering common salt chorcoal funnel wiremesh, earthwork in any type of soil returning filling in and removal of soft/loose soil to a distance n. exc 5 mtr including earth test point and making connections, testing on completion all as per electric plate No 5 of SSR Part-I and directed by engr-in-charge at site including taking down ofold U/S eartning materials
GS TRADERS (BID ID -3097637)
Chandana Enterprises (BID ID -3080550)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .