Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹47.0 L+₹12.3 L (35.4%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹49.3 L+₹14.6 L (42.1%)Rejected-Finance R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹50.1 L+₹15.4 L (44.3%)Rejected-Finance H O WANI HOUSE II SHOWPORA SRINAGAR J K | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹51.0 L+₹16.2 L (46.8%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
3 Apr 2024, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR REPLACEMENT AND MAINT OF INTERNAL ELECTRIFICATION AND CONNECTED ACCESSORIES INSTALLED AT SECTOR C AND ADJACENT AREA UNDER AOR OF AGE EM I OF GE 865 EWS
2024_MES_646529_1
865/EWS(NIT-13)/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹87,000
Yes
31 May 2024
14 Mar 2024
10 Apr 2024
14 Mar 2024
3 Apr 2024
28 Mar 2024
Amount
Dismantling/taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc. complete all as specified and directed.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic,medium grade PVC concealed conduit not less than 25mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
Description all as per item No 2.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 2.00 here in before but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per srl item No 2.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Supply and fix modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fix modular switches, one way, 20 Amps, one module, 230 volt , AC supply, complete all as specified and directed.
Supply and fix modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed.
Supply and fix modular socket outlet 6/20 amps,3 pin, 2 module, complete all as specified and directed.
Supply and fix modular switches, bell push, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fix modular blanking plate 1 module complete all as specified and directed.
Supply and fix switch piano 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
Supply and fix switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, ISI Marked, complete all as specified and directed.
Supply and fix bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
Supply and fix socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed.
Supply and fix socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified.
Supply and fix ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
Supply amd fix lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed.
Supply and fix door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified.
Supply and fix sheet metal enclosure SP with two pin and earth plug and socket inclduing metal clad top with one single pole MCB 20/32 Amp complete all as specified and directed.
Supply and fixing of LED light fitting 1x20W , 220V, AC with aluminium housing with batten type with driver , holder including 20W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector complete all as specifid and directed
Supply and fix batten type with surface mounted LED tube light fitting with high efficient diffuser mirror light, polycarbonate housing in CRCA body suitable and including 10 watt LED tube rod high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fix bulk head light fitting, 10 watt, energy efficient with lamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting complete including disconnecting and taking down old existing light fitting of any description complete all as specified and directed.
Supply and fix bracket for security light made up of 25/40mm dia suitable for security light, 0.6 metre long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
Supply and fix LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply and fix LED security light luminaire 45 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply and fix inverter LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with 4 hours battery back up all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
S&F LED strip light soft glare free light complete with driver (white/warm white colour), holder suitable for wall fittings including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair post top lantern LED 45W , cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing of LED based Bollard light 10 watt with aluminium pipe housing with glare free PMMA Diffuser, IP 65 of height not less than 600mm including necessary excavation & PCC work etc complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fixing of recess/ surface mounted LED flat panel 2' x 2' CRCA powder coated, 36 watt, IP20 with battery back up with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fixing of Inverter LED tube light fitting 1x20 Watt with minimum 04 hours battery back up integrated aluminium batten with diffuser and including 20 Watt LED hight efficient , AC 220-240 V, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fixing inverter LED bulb B-22 cap with opal diffuser, IP20 and inbuilt battery back up of 10 Watt capacity all as specified and as directed
Supply and fixing inverter LED bulk head, IP65 and inbuilt battery back up of 10 Watt capacity complete all as specified and as directed
Supply and fixing LED flood light highly efficient integral type, made of pressure die cast aluminium housing with 10 KV SD lens & toughened glass IP 66, energy efficient provided with including LED 50 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing LED flood light highly efficient integral type, made of pressure die cast aluminium housing with 10 KV SD lens & toughened glass IP 66, energy efficient provided with including LED 100 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 2.5 sqmm drawn in and including rigid non metallic PVC medium grade 20 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.5 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE: - 3 run of 2.50 sqmm cable with concealed conduct shall be measured as 1 unit.
All as per Item No 37 above but for Material and labour for sub main wiring of 6.00 sqmm NOTE:-3 run of 6.0 sqmm cable with concealed conduct shall be measured as 1 unit complete all as specified and directed.
All as per Item No 37 above but for Material and labour for sub main wiring of 4.00 sqmm. NOTE:- 3 run of 4.0 sqmm cable with concealed conduct shall be measured as 1 unit complete all as specified and directed.
Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type ,125AMPS ,25 KA as incomer and MCB s as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed.
All as per Item No 40 above but VTPN DB alongwith MCCB 4 pole,100AMPS 16 KA as incomer and MCB s as out going complete all as specified and directed complete all as specified and directed.
Supply and fixing in repair SPN distibution board 8 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets complete all as specified and directed.
Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, ISI complete all as specified and directed.
Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, ISI marked complete all as specified and directed.
Supply and fixing in repair MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, 'B' Series complete all as specified and directed.
Supply and fix in repair MCCB four pole 415 volts, 160 Amps,25KA, 50 Hz, thermal release adjustable type with settubg upto 70% complete all as specified and as directed.
Supply and fix in repair MCCB four pole 415 volts, 400 Amps,16KA, 50 Hz thermal release adjustable type with setting upto 70% complete all as specified and as directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 10Sqmm including all incoming and outgoing connection with proper size of thimble complete all as specified and directed.
All as per Item No 48 above but one twin core cable circulat of size 16 Sqmm complete all as directed and specified.
Material and labour for taking down existing lighting fiting any type/size/Make/capacity i.e T/L, Surface/ Recess Panel, flame proof, wall light, bulk head, mirror light etcand re-fixing the same after minor repair/cleaning including replacement connection wire with suitable size coper wire twin core 0.75 sqmm for connection from ceiling rose to light fitting complete all as specified and directed.
M&L for attending day to day complaints of E/M nature by means of checking unserviceable Electrical fitting and fixture and emergent fault rectification in elctrical circuit incl no light , earth leakage, short cicuit, neutral break mains /sub mains/internal circuits of existing system of main building / block ,making continious electric supply including carrying out minor repairs etc as required to make system in order / functional by replacing, copper cable , copper thimbles, glands, earthing wire complete all as specified and as directed as required at site by Engineer-in-Charge. NOTE : - (a) Items reqd for replacement such as switchs, sockets for power/light/ fan/ bell/geyser points including complete will be measured and paid under respective items of BoQ. (b) Contractor rep/supervisor will report to MES Service Centre alongwith qualified/Experianced electrician and helper to collect dockets between 0900 hrs to 1000 hrs on all working days for rectification of complaints and resubmit the dockets after completion of each job of each job on the same day. If contractor is failed to submit the docket within 48 hours after issuing of dockets , the contractor i liable to pay the penalty i.e. 20.00 per docket per day till the re-submission of docket. (c) Contractor will attend emergent nature of work i.e. no light, short circuit after working hours/holiday as when ordered. The rate of the is deemed to be included in above quoted rates.
Supply only PVC insulated, unsheathed cable 2.5 Sqmm single core 1100 volt grade with multi stranded copper conductor complete all as specified and as directed.
Supply only Cable PVC copper conductor flexible twin core 0.75mm complete all as specified and directed.
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire 4 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) Taking out old unserviceable earthing complete all as specified and directed. NOTE : - The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to be including in quoted rates.
SUMEET TRADING CORPORATION
M/S ZTECH
M/S WEB COMPNAY
national engineering
RND ENGINEERS & CONTRACTORS
N K BUILDERS
M/S STANZIN NOBROO
M/S GLOBAL ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .