Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.3 L+₹32,601.45 (3.62%)Rejected-Finance 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L2 | Rejected-Finance Being other than L1. | |
| 3 | L3₹10.7 L+₹1.7 L (19.4%)Rejected-Finance | L3 | Rejected-Finance Being other than L1. |
Tender Value
₹8.7 L
EMD Value
₹17,500
Closing Date
12 Sept 2024, 6:00 pmClosed
AGE (I) Naya Raipur
AGE (I) Naya Raipur, Military Engineer Service, C/O HQ COSA, Near International Cricket Stadium, Atal Nagar,Raipur (CG) - 492101
As per BOQ
2024_MES_660445_2
8400/384/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Naya Raipur
As per NIT
7 documents required · 7 mandatory
₹500
AGE (I) Naya Raipur
₹17,500
Yes
24 Oct 2024
22 Jul 2024
14 Sept 2024
22 Jul 2024
12 Sept 2024
29 Jul 2024
Amount
Disconnecting and taking out DG set electric connection from both side incoming and out going electric and DG set supply of 30 KVA DG Set and serving the DG set with authotrised dealer/rep of dealer (kirloskar) and make it complete with all respect as servicing, connecting including replacement of necessary minor spares for the engine and alternator, repair machining of cylinder head for the optimum performance of the machine and overhauling of FIP and injectors with necessary calibration etc all as specified and as directed testing etc with duly change of US Parts of DG Set same shall be paid separately and checking the battery terminals, apply necessary vesline on it and fresh connection complete all as specified and directed Note rate deemed to included the T&P used for this purpose bring by the contractor and If again any fault occur of same nature of repair during the contact period is rectified by the contractor at free of cost. Note : Supply only spares required for repairs shall be measured and paid separately under Sch 'A' item No 2.00 to 15.00 herein after.
Supply only Set of fuel filter elements for replacement during the process of overhaul repair of the generating set vide serial items No-1 here in before.
Ditto - all as per above item No 2 but Set of oil filter elements.
Ditto - all as per above item No 2 but Air filter elements.
Ditto - all as per above item No 2 but Set of hose pipes with kits.
Ditto - all as per above item No 2 but Oil temperature gauge with sensor.
Ditto - all as per above item No 2 but Cylinder liner.
Ditto - all as per above item No 2 but Piston.
Ditto - all as per above item No 2 but Set of upper engine gasket.
Ditto - all as per above item No 2 but CR bearing.
Ditto - all as per above item No 2 but Oil pan gasket.
Ditto - all as per above item No 2 but Cylinder head repair kit complete including valve and valve seat grinding springs collects and sleeves.
Ditto - all as per above item No 2 but Barrel plunger and cup.
Ditto - all as per above item No 2 but Set of Lower engine gasket.
Ditto - all as per above item No 2 but Solonide switch.
S & filling/ changing in replacement of old US oil with of Kirloskar Engine Oil as per prescribed grade of Kirloskar complete all as specified and directed by engr-in-charge
S&F in replcement of coolant of DG set as per existing complete all as specified and directed by engr-in-charge.
Disconnecting and taking out DG set electric connection from both side incoming and out going electric and DG set supply of 62.5/63 KVA DG Set and serving the DG set with authotrised dealer/rep of dealer (kirloskar) and make it complete with all respect as servicing , connecting , including replacement of necessary minor spares for the engine and alternator, repair machining of cylinder head for the optimum performance of the machine and overhauling of FIP and injectors with necessary calibration etc complete all as specified and as directed. testing etc with duly change of US Parts of DG Set same shall be paid separately and checking the battery terminals, apply necessary vesline on it and fresh connection complete all as specified and directed Note rate deemed to included the T&P used for this purpose bring by the contractor and If again any fault occur of same nature of repair during the contact period is rectified by the contractor at free of cost. Note : supply only spares required for repairs shall be measured and paid separately under Sch 'A' item No 19.00 to 32.00 herein after).
Supply only Set of fuel filter elements for replacement during the process of overhaul repair of the generating set vide serial items No 18.00 here in before :-
Ditto - all as per above item No 19 but Set of oil filter elements.
Ditto - all as per above item No 19 but Air filter elements.
Ditto - all as per above item No 19 but Set of hose pipes with kits.
Ditto - all as per above item No 19 but Oil temperature gauge with senser.
Ditto - all as per above item No 19 but Cylinder liner.
Ditto - all as per above item No 19 but Piston.
Ditto - all as per above item No 19 but Set of upper engine gasket.
Ditto - all as per above item No 19 but CR Bearing.
Ditto - all as per above item No 19 but Oil pan gasket.
Ditto - all as per above item No 19 but Cylinder head repair kit complete including valve and valve seat grinding springs collects and sleeves.
Ditto - all as per above item No 19 but Barrel plunger and cup.
Ditto - all as per above item No 19 but Set of Lower engine gasket.
Ditto - all as per above item No 19 but Solonide switch.
S&F in replacement of battery terminal brass suitable for 12 volt 150 Ah battery of DG set complete all as specified and directed by engr-in-charge
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 metre in depth and getting out for laying of pipe cables etc., and getting out complete all as specified and directed.
Returning filling in, including spreading levelling, watering and well ramming in layers not exceeding 25cm thick with earth obtained from excavation complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour for dry river washed and screened dry sand for filling in trenches below and around the cable for cushioning including punning down as specified in relevant clause of SSR Part I complete all as specified and as directed. Note:- Punned thickness shall only be measured and paid.
Supplying and laying reinforced precast concrete cable cover class LV, type 1, size flat size 250 x 150 x 40 mm complete all as specified and as directed.
Taking out carefully existing unserviceable LT cable from pole, panels and trenches any size any capacity and removing connection from existing switch board/ over head line etc complete all as specified and directed by engr-in-charge
Supply/Laying or fixing or passing through pipe, jointing and testing 1100 volt grade XLPE insulated armoured heavy duty PVC insulated, PVC sheathed armoured electric cables 16 sqmm 4 core with aluminum stranded conductor complete all as specified and as directed.
Ditto - all as per above item No 40 but size of cable 50 sqmm 3.5 core.
Ditto - all as per above item No 40 but size of cable 70 sqmm 3.5 core
Supply and laying galvanised iron pipe “Light Grade” 40mm bore dia in trenches, under floors, roads, along poles for protection of cables with all necessary fittings , including sealing ends complete all as specified and as directed.
Ditto - all as per above item No 43 but pipe size 50mm dia.
S& F for onload change over switch (four pole) TPN 40 Amps capacity complete in sheet steel enclosure type FN (TPN) suitable for DIN fuse link and removing existing unserviceable one all as specified and directed by Engr-in-Chage
Ditto - all as per above item No 45 but TPN 63 Amps.
Ditto - all as per above item No 45 but TPN 100 Amps.
Taking down MCCB of any type and any capacity complete all as specified and directed by engr-in-charge.
Supply and fixing MCCBs 4 pole 415 volt adjustable type 250 amps, 36 KA three pole, incl necessary cable connection complete all as specified and directed by Engr-in-charge.
Supply and fixing MCCBs 4 pole 415 volt fixed type 63 amps, 16 KA three pole, incl necessary cable connection complete, all as specified and directed by Engr-in-charge.
Supply and fixing MCCBs 4 pole 415 volt fixed type 100 amps, 16 KA three pole, incl necessary cable connection complete, all as specified and directed by Engr-in-charge.
Supply and fixing MCCBs 4 pole 415 volt fixed type 125 amps, 16 KA three pole, incl necessary cable connection complete, all as specified and directed by Engr-in-charge.
Supply and fixing MCCBs 4 pole 415 volt fixed type 200 amps, 36 KA three pole, incl necessary cable connection complete, all as specified and directed by Engr-in-charge.
M & L for cable glands of size 16 sqmm to 50 sqmm complete all as specified and directed.
M & L for cable glands of size 70 sqmm to 95 sqmm complete all as specified and directed.
M & L for aluminum cable lugs off sizes 16 sqmm to 35 sqmm complete all as specified and directed by Engr-in-Charge
M & L for aluminum cable lugs off sizes 50 sqmm to 185 sqmm complete all as specified and directed by Engr-in-Charge
M & L for Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI strip 32 x 6 sqmm ia by means of GI bolts, nuts, check nuts and washers and earth strip protected by 40 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion. Notes : The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. Note :- Earthing will be redone if desired earth result not found during testing of the same at site.
Supply and fix aluminium strip 25 X 3.15 mm with PVC saddle and PVC gutties for keeping the gap with roof and wall complete all as directed.
Supply and fix GI strip 32 x 6 mm with PVC saddle and PVC gutties for keeping the gap with roof and wall complete all as directed.
Supply and fix in repair Battery 12V 100AH Make-Exide or quivalent from approved list of make complete all as specified and directed.
Supply and fix Combined Voltmeter & Ammeter digital type, square, Make: L & T model ISCELMLX0007 or equivalent for repairs of LT pannel/Dg set pannel boards situated at various installation including making copper cable connections with lugs, connectors, ferrule, glands of suitable size as per requirement etc complete all as specified and directed.
Ditto - all as per above item No 62 but Push button with NC.
Ditto - all as per above item No 62 but Indicating light.
Ditto - all as per above item No 62 but Main contactor 100 Amps Make L&T. model MCX 22 or equivalent model from approved list of make.
Ditto - all as per above item No 62 but Main contactor 130 Amps MCX23 Make L&T. model MCX 23 or equivalent model from approved list of make.
Ditto - all as per above item No 62 but Main contactor 50 Amps Make L&T. model MCX 11 or equivalent model from approved list of make.
Ditto - all as per above item No 62 but Main contactor 63 Amps Make L&T. model MCX 12 or equivalent model from approved list of make.
Ditto - all as per above item No 62 but Main contactor 80 Amps Make L&T. model MCX 13 or equivalent model from approved list of make.
Ditto - all as per above item No 62 but Multi meter(RPM,Frequency & hours) digital type, square, Make:RB model GCX1000 or equivalent model from approved list of make.
Ditto - all as per above item No 62 but CT's 100/5.
Ditto - all as per above item No 62 but CT's 200/5.
Ditto - all as per above item No 62 but Relay Contact with specification 250VAc 10A(NO) , 5A(NC) , 3 NO + 1 NC , PF 0.41 (as per Sample)
Ditto - all as per above item No 62 but DOL starter three phase 415 volts suitable for 05 HP make L&T or equivalent model from approved list of make.
Ditto - all as per above item No 62 but HRC fuse 63A Type HC.
Ditto - all as per above item No 62 but HRC fuse 32A Type HC.
Ditto - all as per above item No 62 but capacitor barrel type of capacity 12.5Kvar of makeL&T model -MDXL or equivalent model from approved list of make.
M & L for Comprehensive maintenance of water cooler 40/80, 60/120 ltr capacity including performing following tasks at different locations at :- (a) Inspection, dismantling front and rear shutte disconnecting electric and water connection (b) Cleaning thoroughly the body of water cooler including cleaning of cold water tank with bleaching powder solution. (c) Servicing of cooling fan by greasing to bearing, oiling to bushes after opening the motor. (d) Checking/rectifying the connection and working of thermostat relays, condenser, evaporator, capacities, switches, electrical connection, float valve, compressor earth connection including replacement of defective wire sleeves etc (e) Replacement of PVC drain pipe from water cooler tray to neared drain. (f) Reconnecting power and water lines and testing to make it functional complete all as specified and as directed.
M & L for Comprehensive maintenance of Refregirator/Deep freezer of any capacity any make including cleaning, checking after repair, connecting the main lead all as specified and directed by Engr-in-Charge.
S & F in repairs of compressor assembly as per existing make (sealed unit) for water cooler incl testing after gas charging complete all as specified and as directed. Note : Gas charging shall be measured and paid for separately.
M & L for Gas charging the water cooler with gas R-134/R-22 capacity 40/80,60/120 litres capacity including making necessary connection, testing etc to make it functional complete all as specified and as directed
S & F in repairs of compressor assembly as per existing make (Sealed unit) for refrigerator of any size, capacity and make including soldering of copper pipe filling of gas, commissioning and testing all as specified and as directed. Note : Gas charging shall be measured and paid for separately.
S & F in repairs of blower motor for inner unit of 1.5 /2 Ton AC split type all as per manufacturer specification complete as per existing make all as specified and as directed
S & F in repairs PCB Card for 1.5/2 ton AC as per existing make complete all as specified and as directed
S & F in repairs of compressor unit (sealed) completed for 1.5 Ton AC as per existing make complete all as specified and as directed
M & L for Comprehensive maintenance of air conditioner split type 15 ton capacity, any make including performing following tasks at different locations at Station :- (a) Inspection, taking down, removing grills and outer housing (b) Descaling, brushing and cleaning thoroughly and replacing filter pad of AC (c) Servicing the cooling fan by greasing/oiling the bearing bushes after opening the motor, cleaning the armature, checking and tightening all nuts and bolts etc (d) Checking rectifying the connection, working of thermostat assembly, relay, condenser, heater assembly, compressor and earth connection etc including replacing defective wire and sleeves etc (e) Re-fixing AC in position, after assembling including packing as required at site and testing complete to make it functional Note : Supplying and replacement of parts shall be measured and paid separately
M & L for repairing to voltage stabilizer 5 KVA/20 Amps 2/3 step, wall mounting digital type including replacement of relay, electronic circuit, connection socket/ terminal, indicating lamp, copper cable of suitable size 3 core with lug connector, voltmeter if required and other defective parts for high and low voltage cut off and automatic adjustment complete all as specified and as directed.
Ditto - All as per above item No 88 but 4 KVA
Ditto - All as per above item No 88 but 3 KVA
Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 21,331.00
M K ENTERPRISES (BID ID -3093270)
M/S INDIA ENTERPRISES (BID ID -3087305)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .