Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹27.8 L+₹3.1 L (12.7%)Rejected-Finance 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹28.5 L+₹3.8 L (15.5%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹30.2 L+₹5.5 L (22.5%)Rejected-Finance MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹34.9 L+₹10.2 L (41.4%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
| Sl No | Description | Qty | Unit | PROACH ASSOCIATES BUILDERS & ENGINEERS L1 | M/S M P Construction Co L2 | PAWAN KUMAR GOVT. CONTRACTORS L5 | RANBIR ENTERPRISES L4 | PRATAP TRADING CO L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked of size 35 Sq.mm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing with taking down unserviceable cable complete all as specified and directed.
Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engineer-in-Charge before laying the cable.
(ii) Excavation & earth work will be measured and paid separately. | 150 | RM | 220 ₹33,000 | 100 ₹15,000 Lowest | 350 ₹52,500 | 180 ₹27,000 | 260 ₹39,000 |
| 2.00 | All as per Item No. 1 herein before but cable of size 25 sqmm, 4 core complete all as specified and directed. | 200 | RM | 190 ₹38,000 | 80 ₹16,000 Lowest | 250 ₹50,000 | 130 ₹26,000 | 240 ₹48,000 |
| 3.00 | All as per Item No. 1 herein before but cable of size 16 sqmm, 4 core complete all as specified and directed. | 400 | RM | 165 ₹66,000 | 70 ₹28,000 Lowest | 198 ₹79,200 | 100 ₹40,000 | 190 ₹76,000 |
| 4.00 | All as per Item No. 1 herein before but cable of size 240 sqmm, 3.5 core complete all as specified and directed. | 200 | RM | 1,190 ₹2,38,000 | 380 ₹76,000 | 1,475 ₹2,95,000 | 285 ₹57,000 Lowest | 1,300 ₹2,60,000 |
| 5.00 | Supply & Fix in repairs of Polycarbonate Thermoplastic Junction Box for outdoor type IP-67/69 Protection Mini. Size 155 x 210 x 92. The Junction Box shall be UV resistance test IEC 61439-1,anti-acid, anti corrosive, glow wire test 960 degrees as per IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing ,Weather Proof, Rust Proof, Dust Proof, Rainwater Proof, mechanical load shall be IK08 (5 Joule) Accordance IEC 62262. The Junction box RAL 9011 colour Black. The junction box Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories and Four Side Walls shall have knockouts for cable entry & Provision for Din Rail including 20 Amp MCB SP with lugs of suitable size up to 25 sqmm . The gasket shall be internally embedded made of polyurethane. The Junction Box shall be with complete all accessories ( Cable Glands for 16-25 Sq.mm 3 Core Cable - 2 Nos and 4 Sq.mm 3 Core - 2 Nos, TPN Terminals - 1 No 63A , ISO-FILL BRW Gel for water proofing, Pole mounting Clamp and nut bolts etc). Make-Cat No. KF 1600 B of Hensel or its equivalant as Schneider/ABB/Siemens. | 34 | Each | 1,900 ₹64,600 | 800 ₹27,200 Lowest | 1,250 ₹42,500 | 1,400 ₹47,600 | 1,400 ₹47,600 |
| 6.00 | Supply and fix LED street light fitting of capacity 150 watt in yellow colour with intergral wellglass luminaire epoxy finish aluminium alloy housing with heat resistant and toughened glass cover painted MS wire guard, IP - 66, 6000K CCT high power LED incuding all accessories pre wired with polycarbonate cover polyester die cast resin encloser and central locking system, with taking down unserviceable light any type complete all as specified and directed.
Make cat pt No LSRT01S150XW of Jaqar or its equivallent to HPL cat Pt No HPLLEDSL15060S/Bajaj. | 20 | Each | 4,890 ₹97,800 | 3,500 ₹70,000 | 5,500 ₹1,10,000 | 2,100 ₹42,000 Lowest | 4,000 ₹80,000 |
| 7.00 | Supply and fix LED street light fitting of capacity 180 watt in yellow colour with intergral wellglass luminaire epoxy finish aluminium alloy housing with heat resistant and toughened glass cover painted MS wire guard, IP - 66, 3000K CCT high power LED incuding all accessories pre wired with polycarbonate cover polyester die cast resin encloser and central locking system, with taking down unserviceable light any type complete all as specified and directed.
Make cat pt No cat pt No LSRT01S180XW of Jaqar or equivallent to HPL Cat Pt No HPLLEDSL18060S /Bajaj. | 14 | Each | 6,000 ₹84,000 | 4,200 ₹58,800 | 6,800 ₹95,200 | 2,300 ₹32,200 Lowest | 5,000 ₹70,000 |
| 8.00 | Supply and fix in repairs three core copper cable of size 2.5 Sqmm 1100 volt heavy duty PVC insulated served with inner sheathing PVC tape and overall PVC round sheathed in service connection complete all as specified and directed. | 200 | RM | 98 ₹19,600 | 30 ₹6,000 Lowest | 118 ₹23,600 | 60 ₹12,000 | 190 ₹38,000 |
| 9.00 | M&L for PVC DWC black pipe laid in trenches 90 mm dia medium grade for cable protection with taking down unserviceable pipe type complete all as specified and directed | 100 | RM | 120 ₹12,000 | 50 ₹5,000 Lowest | 198 ₹19,800 | 125 ₹12,500 | 160 ₹16,000 |
| 10.00 | M&L for PVC DWC black pipe laid in trenches 63 mm dia medium grade for cable protection with taking down unserviceable pipe complete all as specified and directed | 100 | RM | 60 ₹6,000 | 25 ₹2,500 Lowest | 162 ₹16,200 | 85 ₹8,500 | 150 ₹15,000 |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
27 Nov 2025, 6:00 pmClosed
GE AF UDHAMPUR
GE AF STATION UDHAMPUR
SPECIAL REPAIRS TO CERTAIN SECURITY LIGHTS AND E/M INSTALLATIONS AT AF STN NATHATOP UNDER GE (AF) UDHAMPUR
2025_MES_738667_1
GEAFU-59/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE (AF) STATION UDHAMPUR
SPECIAL REPAIRS TO CERTAIN SECURITY LIGHTS AND E/M INSTALLATIONS AT AF STN NATHATOP UNDER GE (AF) UDHAMPUR
8 documents required · 8 mandatory
₹500
GE (AF) UDHAMPUR
₹58,000
12 Dec 2025
6 Nov 2025
29 Nov 2025
6 Nov 2025
27 Nov 2025
20 Nov 2025
6 Nov 2025 - 13 Nov 2025
Amount
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked of size 35 Sq.mm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing with taking down unserviceable cable complete all as specified and directed. Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engineer-in-Charge before laying the cable. (ii) Excavation & earth work will be measured and paid separately.
All as per Item No. 1 herein before but cable of size 25 sqmm, 4 core complete all as specified and directed.
All as per Item No. 1 herein before but cable of size 16 sqmm, 4 core complete all as specified and directed.
All as per Item No. 1 herein before but cable of size 240 sqmm, 3.5 core complete all as specified and directed.
Supply & Fix in repairs of Polycarbonate Thermoplastic Junction Box for outdoor type IP-67/69 Protection Mini. Size 155 x 210 x 92. The Junction Box shall be UV resistance test IEC 61439-1,anti-acid, anti corrosive, glow wire test 960 degrees as per IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing ,Weather Proof, Rust Proof, Dust Proof, Rainwater Proof, mechanical load shall be IK08 (5 Joule) Accordance IEC 62262. The Junction box RAL 9011 colour Black. The junction box Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories and Four Side Walls shall have knockouts for cable entry & Provision for Din Rail including 20 Amp MCB SP with lugs of suitable size up to 25 sqmm . The gasket shall be internally embedded made of polyurethane. The Junction Box shall be with complete all accessories ( Cable Glands for 16-25 Sq.mm 3 Core Cable - 2 Nos and 4 Sq.mm 3 Core - 2 Nos, TPN Terminals - 1 No 63A , ISO-FILL BRW Gel for water proofing, Pole mounting Clamp and nut bolts etc). Make-Cat No. KF 1600 B of Hensel or its equivalant as Schneider/ABB/Siemens.
Supply and fix LED street light fitting of capacity 150 watt in yellow colour with intergral wellglass luminaire epoxy finish aluminium alloy housing with heat resistant and toughened glass cover painted MS wire guard, IP - 66, 6000K CCT high power LED incuding all accessories pre wired with polycarbonate cover polyester die cast resin encloser and central locking system, with taking down unserviceable light any type complete all as specified and directed. Make cat pt No LSRT01S150XW of Jaqar or its equivallent to HPL cat Pt No HPLLEDSL15060S/Bajaj.
Supply and fix LED street light fitting of capacity 180 watt in yellow colour with intergral wellglass luminaire epoxy finish aluminium alloy housing with heat resistant and toughened glass cover painted MS wire guard, IP - 66, 3000K CCT high power LED incuding all accessories pre wired with polycarbonate cover polyester die cast resin encloser and central locking system, with taking down unserviceable light any type complete all as specified and directed. Make cat pt No cat pt No LSRT01S180XW of Jaqar or equivallent to HPL Cat Pt No HPLLEDSL18060S /Bajaj.
Supply and fix in repairs three core copper cable of size 2.5 Sqmm 1100 volt heavy duty PVC insulated served with inner sheathing PVC tape and overall PVC round sheathed in service connection complete all as specified and directed.
M&L for PVC DWC black pipe laid in trenches 90 mm dia medium grade for cable protection with taking down unserviceable pipe type complete all as specified and directed
M&L for PVC DWC black pipe laid in trenches 63 mm dia medium grade for cable protection with taking down unserviceable pipe complete all as specified and directed
M&L for PVC DWC black pipe laid in trenches 50 mm dia medium grade for cable protection with taking down unserviceable pipe complete all as specified and directed
M&L for boring holes horizontally under road/pavement/hardstanding manually in soft/loose soil without cutting/disturbing the existing road surface for inserting 50 mm bore pipe at a depth 600 mm for UG cable protection including GI Pipe complete all as specified and directed.
Supply and fix in repairs 50 mm GI bracket of 0.75 M length with suitable size of nuts, bolts and clamps for fixing street light on pole including painting with two coats of aluminium paint over a coat of primer complete all as specified and directed
M&L for Earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized earth strip of 20X3mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of SSR Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized earth strip of 32X6mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of SSR Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion
Supply and Fix in repairs earth continuity conductor or main galvanised iron strip of size 25 x 4 mm burried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necesarry insulators and fastning screws, rawl plugs complete all as specified and directed. NOTE: - The joints of each lead strip shall be welded / brazed and the cost of brazing / welding shall deem to be included in unit rate of this item.
Supply and Fix in repairs earth continuity conductor or main copper strip of size 20 x 3 mm burried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necesarry insulators and fastning screws, rawl plugs complete all as specified and directed. NOTE: - The joints of each lead strip shall be welded / brazed and the cost of brazing / welding shall deem to be included in unit rate of this item.
Supply and fix of 20 KVA capacity on line UPS with sine wave form and double converson online UPS technology suitable for minimum 30 minutes back up, three phase AC, designed for input voltage of 380 to 415 Volts and output voltage at 400 Volts with accuracy of + 1% comprising of the following provisions and specifications including taking down complete all as specified and directed: - (a) Technology : IGBT based Double conversion PWM based online UPS. (b) Parallel mode : 4(N+1) (c) Input Parameters : (i) Rated : 400 VAC 3 hse, 4 wire. (ii) Voltage range : three phase 175 VAC -498 VAC. (iii) Rated frequency : 50Hz/60 hz. (iv) Frequency range : 40 Hz to 70 Hz. (v) Power factor : 0.95 for three fase. (d) Output Parameters - (i) Output voltage : 20 KVA/20 KW. (ii) Output voltage : three phase 415 VAC single phase. (iii) Output voltage - three phase 415 VAC/ 230 VAC single phase. (iv) frequency synchronization range : rated frequency + 3 Hz. configurable range : + 0.5 Hz to + 5 Hz (v) Rated power factor : Unity. (vi) Crest factor : 3:1' (Vii) Voltage harmonic distortion : <2% (linear load). (viii) Voltage relation : 1% (ix) dinomec response recovery time : 60ms. (x) Inverter over load capability on utility mode : at 25 degree : 105% - 125% - 10 min, 125% to 150% - 1min, 150% - more than 200 ms. (xi) (d) inbuilt bypass should be separate.. (e) efficiency : ECO mode : 96%. online mode > 96%. inverter efficiency > 92% . (f) transformer time : Synchronous transfer < 0 ms. Asynchronous tranfer : < 20 ms. (g) Noise : 65db. (h) Envirenmental Parameter : (i) Relative humidity : 5% RH - 95 % RH non-condensing and height of site is above 9000m abobe MSL. (j) Display : Graphical LCD display. (k) Battery type : SMF VRLA, Tubular, LI-ION (for 30 mins back up as per OEM) ((m) Number of battery : 24, 32, 40 Adjustable in even block. (n) Battery charger : 12 V inbuilt charger. (p) Ingress protection level :IP : 20. (q) Surge Protection : IEC/EN62040-2, meeting IEC/EN61000-4-5 (r) Backup : 30 minutes on each UPS (Minium 12200 VAH as per UPS OEM). (s) Provision of rack made up of MS power coated sheet and all sizes of interconnection cables complete in all respect.
S & F in repairs, installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made LT feeder panel shall be made of modular Polycarbonate thermoplastic rnclosure which should be UV resistance, Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate of degree of ingress protection IP 68 in accordance with IEC 60529 and the share panel assembled by OEM , channel partner or sister concerned assembly will not be accepted. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The gasket should be internally embedded made of polyurethane. The panel should pass glow wire test 96 0 C in accordance with 60695-2-11 [flame retardant and self-extinguishing]. LT Feeder panel size minimum 1800 mm x 1200 mm x 450 mm,415 volts for outdoor uses as to accomodate following listed accessories , with Copper TPN Bus Bar rating 800 Fixed on insulators on PVC / epoxy insulators, mounted on angle legs of size 25mm x 25mm x 5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer ,legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded stone aggregate) complete with suitable cable Glands/Grommets and including all provision of opening for incomming/outgoing cables and testing complete all as directed. Make- Hensel / L&T/ Schneider/ ABB.
The Feeder panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland adge of Brass CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) Supply and fix onload changeover of capacity 630 Amp with , 4 Pole, 36 KA, 50 Hz with with pypass arrangement ----- 02 No. OUTGOING :- (i) Supply and Fix MCCB 630 Amps 36 KA 4 Pole microprocessor based release --- 4 No MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. Make : LEGRAND /SCHNEIDER / ABB INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED - 01 set of 3 lamps (RED,YELLOW & BLUE) Digital Multifunction meter - 01 No. Make : L&T / AE/ CONZERV / ELMEASURE C.T having Ratio 800/5, resin cast, - 03Nos.
S & F in repairs, installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made LT feeder panel shall be made of modular Polycarbonate thermoplastic rnclosure which should be UV resistance, Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate of degree of ingress protection IP 68 in accordance with IEC 60529 and the share panel assembled by OEM , channel partner or sister concerned assembly will not be accepted. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The gasket should be internally embedded made of polyurethane. The panel should pass glow wire test 96 0 C in accordance with 60695-2-11 [flame retardant and self-extinguishing]. LT Feeder panel size minimum 1800 mm x 1200 mm x 450 mm,415 volts for outdoor uses as to accomodate following listed accessories , with Copper TPN Bus Bar rating 500 Fixed on insulators on PVC / epoxy insulators, mounted on angle legs of size 25mm x 25mm x 5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer ,legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded stone aggregate) complete with suitable cable Glands/Grommets and including all provision of opening for incomming/outgoing cables and testing complete all as directed. Make- Hensel / L&T/ Schneider/ ABB.
The LT panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland adge of Brass CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) Supply and fix onload changeover of capacity 315 Amp with , 4 Pole, 36 KA, 50 Hz with with pypass arrangement ----- 02 No. OUTGOING :- (i) Supply and Fix MCCB 315 Amps 36 KA 4 Pole microprocessor based release --- 4 No MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. Make : LEGRAND /SCHNEIDER / ABB INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED - 01 set of 3 lamps (RED,YELLOW & BLUE) Digital Multifunction meter - 01 No. Make : L&T / AE/ CONZERV / ELMEASURE C.T having Ratio 500/5, resin cast, - 03Nos.
S & F in repairs istallation, testing and commissioning for microprocessor based factory fabricated AMF control panel type tested from OEM indoor / outdoor type system suitable for 320 KVA DG set with and including internal wiring, free standing, floor mounted type, vertical type, front operated, dust & verminn proof & sound proof canopy fabricated out of 3.15 MS CRCA sheet duly undergoing with pretreatment covering degreesing water rinsing, derusting/phosphating, After pre treating sheet metal shall be sprayed with high corrison resistance primer and finally epoxy polyester power coating of flint grey shade in the panel consisting the following :-
Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc or /getting out cable cover and stacking for reuse/ credit , trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing surplus excavated soil nexc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for dry sand cushioning to underground cables with 8 CM thick before laying of cables and 15 CM thick after laying and stretching of Cable complete all as specified and directed.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
M/S M P Construction Co (BID ID -3484071)
PRATAP TRADING CO (BID ID -3484278)
RANBIR ENTERPRISES (BID ID -3483543)
PAWAN KUMAR GOVT. CONTRACTORS (BID ID -3484309)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_827111.xls
BOQ • 2.67 MB
TENDER59.pdf
Tender Documents • 1.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .