Loading…
Loading…
Tender Value
₹61.1 L
EMD Value
₹1.2 L
Closing Date
24 Jul 2026, 3:30 pm
Provision of communication facility to sub divisional hospital, RPF barrack, ADEN office and other Engineering Depots along with utility shifting/ relocation on Solapur division of Central Railway.
SUR-N-T-2026-27-18
SUR-N-T-2026-27-18
Open
12 Months
Solapur, Maharashtra
₹0
₹1.2 L
30 Jun 2026
30 Jun 2026
10 Jul 2026
01-Tender Schedule
Item Breakup - 01-Tender Schedule
Supply of Indoor Access Points similar to TP-Link Numbers EA225-POE from Cisco or TP Link or D-Link or Ubiquity. (Inspection by Consignee)
Supply of 8 Port Smart Managed Switch with 8- Numbers Port Giga PoE Ethernet & 2-Port Giga SFP loaded with SM Fiber Transceiver (1310nm) of reputed make such as TP Link/ DLink/ Cisco/ Juniper only. (Inspection by Consignee)
Supply of factory molded Cat-6 patch cord 1 Mtr Numbers from D-link or DAX or Krone or Finolex make. (Inspection by Consignee)
Laying & drawing of communication/ power Metre /data cable through PVC conduit pipe/ casing caping. This includes fixing of pipe/casing with all accessories as required as per site condition with proper identification marks and as per the instruction of site engineer. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply of Multifunction Machines (MFM) as per Numbers specification with on site OEM Warranty of 3 Year from HP or cannon or Epson (Inspection by Consignee)
Supply of 1G BiDi SFP modules compatible to Numbers switches of any make and model. (Inspection by Consignee)
Supply of CAT 6 UTP 24 port loaded patch panel Numbers from D-Link or Avaya or Lucent or AT&T or Comscope make. (Inspection by Consignee)
Supply of STP (shielded Twisted Pair) CAT-6 Boxes cable from D-Link, Finolex, Lucent or DAX Make(1 Box-305 mtrs) (Inspection by Consignee).
Supply of Media converters with one Fiber port Pair (SC connector) and four Ethernet ports, supporting port isolation and with built in AC Power supply. Model: FABIO 104L of make MRO- TEK or similar model of RAD, ANDA Telecom, ZYXEL or CTC only.(Inspection by Consignee)
Supply of High throughput LAN extenders as Pair per RDSO specification No.RDSO/SPN/ TC/80/2020 Ver 2.0. (Inspection by Consignee)
Supply of Krone module of 10 pair each from Numbers Krone or DAX or OBO or R&M make. (Inspection by Consignee)
Supply of PVC switch board 10 Pair, 0.5mm dia Metre twisted pairPVC insulated, PVC sheathed, ATC copper conductor as perTEC specification no. TEC/GR/WIR009/05 March 2011 orlatest from Network or Finolex or Synergy or Delton make. (Inspection by Consignee)
Supply of PVC switch board 05 Pair, 0.5mm dia Metre twisted pair PVC insulated, PVC sheathed, ATC copper conductor as per TEC specification no. TEC/GR/WIR/06/03 March 2002 or latest from Network or Finolex or Polycab or Delton make. (Inspection by Consignee)
Supply of multiport I/O box surface mounting Numbers having two RJ-45 port and three RJ-11 port from D-Link or Legrand or Anchor or similar reputed make. (Inspection by Consignee)
Fixing of UTP I/O box as per the instruction of Numbers site Engineers of the Railways.
Supply of single line caller ID hand free Numbers telephone with speaker of make Beetel M 53 or latest with RJ 11 rosettes and 3 No. of pen torch cells Eveready or Novino to be supplied with each instrument and warranty of 01 year. (Inspection by Consignee)
Supply of Control IP telephones (PoE) without Numbers hands free and attachable gooseneck (microphone with base unit) operation for way side control telephone as per clause 8 of RDSO specification No.RDSO/SPN/TC/ 99/2023 Ver 3.0 or latest . (Inspection By RDSO)
Supply of Toughened moulding composite DP Numbers box for 20 pair Krone module along with mounting, fixing bracket size of DP box 230mm X 170mm X 105mm similar to ITR120 module. Make Sintex, Network, Krone. (Inspection by Consignee) SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply, Installation, Testing and commissioning Numbers of Single Fiber based multi service multiplexer with 2 optical port, 2 E1 and 8 E&M Circuits similar to MRO-TEK/MAPLE-1C(O)(V4) make or similar from Team link or Cygnus or Mro-Tek. (Inspection by Consignee)
Supply of OFC Pluggable Module suitable to be Numbers accommodated in multiservices multiplexer equipment as above from OEM. (Inspection by Consignee)
Supply of Wall Mounting Speaker BOSCH/ Numbers L'Acoustic /Renkus Heinz or superior as per specification. All necessary accessories required for installation will be supplied/provided by contractor. (Inspection by Consignee)
Supply of 6 fibre single mode armoured Metre OPTICAL FIBRE Cableas per ITU-TG 652D specification make D-Link or Digisol or AMPor Molex make. (Inspection by Consignee)
Supply of 12 port LIU, 19 inch rack mountable Numbers as per following specification: a) It should have12 SP type ports for termination of SM optical fibres.b) It should be rack mountable with 1U height. c) It should be equipped with front managed saddle for jumper/patch cord management. d) It should have 12 SC termination. e) It should be equipped with adequate nos.of splicing trays to splice 12 fibres. f) It should have proper rubber grommet for cable protection and to minimize dust build up. g) It should be fully loaded with all the accessories for splicing and termination of fibres. h) It shall be of reputed make like D-Link or 3M or Digilink or Molex make.(Inspection by Consignee)
Installation & commissioning of 12 port LIU with Numbers all accessories and shall be used for terminations of optical fibers into the splice trays supplied with it, it shall be installed inside the 19 inch rack using all required fixing/ installation material like nuts, bolts, screws and cable ties etc. as per requirement. The splice trays shall be placed and secured into the LIU after splicing. The SC terminations shall be fixed and secured after splicing of the pigtails into the LIU. It shall be ensured that the movement of the trays is easy and free of any obstructions.
Supply of optic fiber pigtails for termination of Numbers OFC cables withfollowing specification: a) Itshall be single mode SC/SCtype with push pull mechanismor as per site requirement andfully compliance with latestindustry standard. b) It shallhave length of 2 Meters atleast. c) It shall have SCconnector at one end and othershall be loose for splicing. d) Itshould be of reputed make D-Link or 3M or Digilink or Molex. (Inspection by Consignee). SOLAPUR DIVISION-S AND T/CENTRAL RLY
Splicing/ fiber/pigtail in LIU/IObox/terminal joint through fusion splicing for termination of OFC cables. The fibers terminated shall be tested and test report (hard copy and soft copy) shall be submitted to the Railways site in-charge for records. each fiber shall be properly marked with necessary ferrules/tags, as per following specification: i) The optical fibre cables shall be entered in to the rack through cable entry and using the cable guides. ii) The loosened ends of the fibres and pigtails shall be properly prepared for termination in to the already fixed LIU. iii) Eachof the fibre shall be spliced witha pigtail by the method of fusion splicing using a Fusion Splicing Machine of standard reputed make. The splicing shall be done carefully by a skillful person. iv) The splices shall be carefully placed and well secured in the splice trays of the LIU. v) Each fiber /pigtail shall be properly marked with necessary ferrules/tags.vi) The extra length of the fibers / pigtails shall be coiled and placed and secured with cable ties. vii) The optical connectors of the pigtails shall be placed into the patch panel as per the numbering of fibers.viii) All of the terminated fibers shall be tested with OTDR and test report (Hard copy and Soft copy) shall be submitted to the Railways site In-charge for records.
Supply of OFC patch cord with connector at Numbers both ends single mode Simplex 05 Mtr. Make of 3M or Sterlite or Finolex or Raychem. (Type of connector will be specified by consignee) (Inspection by Consignee)
Blowing/drawing of OFC cable in HDPE/DWC Kilometre duct and protective work, as per direction of site engineer.
Supply, installation and commissioning of On Numbers Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type Rating of UPS: 5.0 KVA, Indicative Backup time: 60 Minutes. This includes supply of external battery (42Ah Min) or as required to cater the back up time. (Inspection by Consignee)
Supply of SMPS Based Battery Charger Numbers 48V/50A, FR-BC in 2 plus 1 configuration using 03 modules of 25 Amp (SMR) each, as per RDSO spec.No.RDSO/SPN/ TL/23/99 Ver.4.0 or latest. (Inspection by RDSO)
Supply Sealed maintenancefree VRLA Battery Set set of 24 Cells (Stackable) each cell of 2Volt 200AH Capacity. Fully Charged Confirming to RDSO Specification No.IRS/S-93/96(A) with latest amendment complete with connecting Links and mounting rack along with user manual. (Inspection by RDSO)
Supply of Maintenance free VRLA Battery set of Numbers standard make similar to Exide / Amararaja, 2V per cell, 300 AH capacity in stack of 24 cells for giving a out put voltage of 48V complete with associated base plates interconnecting cables, connectors for the rows and cells with all accessories as per RDSO SpecificationNo.IRS 93/96(A) Amdt.1 or latest. (Inspection by RDSO)
Installation, Testing and Commissioning of Set Battery set with battery charger as per site condition with all tools & plant, petroleum jelly and accessories as required. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply of 9U wall mounting rack of size 600 Numbers mm wide and 500 mm depth, cabinet made up of steel powder coated light gray painted, glass door with lock and key and other complete accessories such as 5x 6A power socket module, 2 fan trays etc from HCL or President or APW or Valrack. (Inspection by Consignee)
Supply digital psophometer as per specification Numbers similar to APLAB make Model 1072 or equivalent as per TEC specs.(Inspection by Consignee)
Supply of Class B&C surge protection Device Numbers (SPD) type I & II with visual indication and potential free contract for remote monitoring as per RDSO spec No. RDSO/SPN/165/2012 version 3.0 or latest and IEC standard 61643 for single phase 230 V AC application, handling lightning surges of 10/350 microseconds and switching surges of 8/20 microseconds. One set consists of 3 Nos of SPD (Two Nos of B Class (L N, N-E) and one no of C class (L-N) all enclosed in a box with KEMA or VDE certified as per latest IEC 61643-11-2011 standard class B&C surge protection device required with Three modules only. (Inspection by Consignee)
Supply of Lighting surge arrestors for LAN Numbers network class C type as per VDE classification housed in a suitable impact resistance box. The equipment shall support one input and one output port with provision for ground connection for surge suppression. the equipment shall be from Ubiquiti or Tuvpavco or DiTek or Tripp-Lite.(Inspection by Consignee)
Supply of PVC channel of size 50x50 mm with Metre all accessories like joint, bends etc of precision, Garware make or similar standard make. (Inspection by Consignee)
Supply of PVC casing & capping of size 25mm x Metre 25mm x 1mm thickness of Precision or Garware or Presto make. (Inspection by Consignee)
Fixing of PVC casing caping of size 25mm/ Metre 50mm or PVC channels or conduilt pipe on wall etc. with suitable fasteners as per route given by and as per the instruction of site engineer of Rly.This inclues breaking up of wall for cabling & painting it to original level & laying of cables.
Supply of PVC conduit pipe of size 25mm x Metre 2mm of pipe heavy duty with all accessories of Astral make or similar reputed make. (Inspection by Consignee)
HDPE pipe 110 mm Diameter, PE63, Class PN6, Metre with confirming to IS4984 with ISI marked (or) Latest. Type test report from Central Govt./state Govt/NABL/ILAC to be submitted at the time of supply. (Inspection by Consignee)
Supply of HDPE duct 50 mm dia, inner dia 42 Kilometre mm and wall thickness 4mm, permanently lubricated etc. to be supplied from TEC approved sources as per Specification TEC GR No. GR/TX/ CDS-008/03/ March 11 with latest amendment. (Inspection by Consignee)
Laying & fixing of HDPE duct for protection of Kilometre cable in trenches or roof wall etc as per route given by site Engineer of Railways.
Supply of RCC pipes half round of size 150mm Numbers 1000.00 dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection by RITES) SOLAPUR DIVISION-S AND T/CENTRAL RLY
Laying of RCC half round cement pipe of Metre appprox. Size (150/300mm dia X 2 mtr. length) inside the trench after laying of cable. Pipes shall be placed as per directives of site engineer.
Supply of GI pipe, inner dia. 100mm dia. B-class Metre as per spec.No.IS 1239 PT. 1/2004 or latest with sockets and fittings.TATA, JINDAL/ ZENITH BIRLA make. (Inspection by Consignee)
Fixing of GI pipes for crossing the culverts, Metre bridges etc. andconcreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.
Supply, Transporting and installation of Numbers concrete (RCC) route indicators at intervals of 50 meters . They should be standard RCC with letters on one side "CR" and the other side "S&T Cables" as per drawing SK 12/10 of RVNL SC. In case of Telecom quad cable joint locations it shall be painted with RED colour.(Inspection by Consignee)
Conceal Wiring with cuting the wall and repair Metre in 04 inch width.This includes supply of Concelling pipe/channel also.
Excavation of cable trench as per cable route cum plan,1.0 mt.deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by stones/bricks,clearing of route,bushes etc.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineerat site. In case depth of trench is not achievable due to site conditions proportionate payment will be made.
Excavation of cable trench as per cable route cum plan,1 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by stones/bricks,clearing of route,bushes etc.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. In case depth of trench is not achievable due to site conditions proportionate payment will be made.
Where ever depth of 0.5 m cable trench is not cum feasible cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor'sown materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.
Cutting of all types of Roads/ platforms cum preparatory to trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.
Laying of signalling/Power/Telecom cable of Kilometre various cores/sizes intrenches. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Horizontal boring of cable duct of minimum 2.0 Metre Mtr. depth along with laying of 120mm HDPE pipe for other locations with minimum depth reckoned from ground level. The work shall be done as per extant practice & instructions of site Engineer. Prepration of site for Horizondal boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. BORING upto the length of 150mtrs. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative.
Maintenance RDSO/SPN/197/2008 or latest consisting of: (1) Copper bond steel electrode 3 Mtr long 17 mm dia with copper bonding thickness of min 250 micron & UL listed & marked-01 No. (2) Earth Enhance compound RDSO approved in sealed bag of 10 Kg-03 Nos. (3) Copper strip 150 x 25 x 6 mm-02 Nos. (4) Copper strip 300 x 25 x 6 mm-01 No. (5) 35 Sqmm copper cable to connect earth electrode to MEEB-15 Mtr. approximately. (Inspection by RDSO)
Installation RDSO/SPN/197/Ver 1 or latest, to construct earthing of </= 1 Ohm consisting of: a) Digging the earth to required depth, insertion of electrode, filling of earth enhancing compound & construction of chamber, measurement of earth value and other work of earthing as per code of practice. All the consumables for mounting the copper tape inside the equipment room, exothermic weld material and tools & fixtures for the welding copper tapes and electrodes etc. shall be arranged by the contractor. Total 6107641.81
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Instructions_To_Tenderer_PWI_KWV.pdf Instructions to Tenderer
ATTACHMENT
Special_Condition_PWI_KWV.pdf
ATTACHMENT
GCC with ACS
ATTACHMENT
Tender_form_Annexure-I.pdf
ATTACHMENT
Cable_cut_policy_CR_1st_Sept_23.pdf
ATTACHMENT
Instructions_To_Tenderer_PWI_KWV.pdf
ATTACHMENT
GCC_April-2022_with_ACS_11_13032026.pdf
ATTACHMENT
Download all tender documents and submit your bid