Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance OFFICE NO 206 D WING EXTENSION RAIKER CHAMBERS DEONAR VILLAGE ROAD GOVANDI EAST MUMBAI 400088 | MUMBAI | MUMBAI | MAHARASHTRA | 400088 | Admitted-Finance |
| 2 | Admitted-Finance 1 GANESH DARSHAN ADV SURVE MARG SANDHURST ROAD W MUMBAI 9 | MUMBAI | MAHARASHTRA | Admitted-Finance |
Tender Value
₹74.4 L
EMD Value
₹1.8 L
Closing Date
22 Jan 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE and Head, Centralised Services Section
CE and Head CSS, TSD
Operation, Maintenance and Upgradation of electrical system of SAS facility of BARC at Gauribidanur, Karnataka-561208
2025_BARC_844019_1
BARC/CSS/ET/44/2024-2025
Open Tender
Electrical Works
Item Rate
730 days
SAS Facility at SAS BARC Facility, Gauribidanur
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.8 L
Yes
PG Hostel, Anushaktinagar, Mumbai-400094
6 Mar 2025
13 Jan 2025
24 Jan 2025
13 Jan 2025
22 Jan 2025
13 Jan 2025
13 Jan 2025 - 20 Jan 2025
17 Jan 2025
Amount
Operation, monitoring and data logging of various electrical equipments of the electrical power system of the entire SAS facility of BARC at Gauribidnaur on day to day basis as per TSS-1
Preventive Maintenance with Oil filteration and testing of 100kVA transformers as per TSS-2
Preventive Maintenance with Oil filteration of 200kVA transformers as per TSS-2
Painting of Transformer of rating 100kVA to 200kVA as per TSS-3
Replacemement of all gasket and rectification of oil leakage in transformers of rating 100kVA to 200kVA as per TSS-4
Preventive Maintenance with Oil filteration and testing of 100 kVA AC Voltage Stabiliser) as per -TSS-5
Routine Maintenance and testing of 100 to 160kVA DG Set (2Nos X 24 Months)with AMF as per TSS- 6
Preventive Maintenance and testing of LT PCC panel (15Nos X 2 times = 30 Nos)as per TSS-7
Preventive Maintenance Electrical Distribution boards(30Nos X 2 times = 60 Nos)as per TSS-8
Comprhensive Maintenance of 3X20kVA UPS set of M/s Dubas make with battery bank and transfer switch (1 Set X 8 Times) as per TSS-9
Comprhensive Maintenance of 2X10kVA UPS set with battery bank and transfer switch as per TSS-10
Comprhensive Maintenance of 2X3kVA UPS set with battery bank and transfer switch as per TSS-10
Supply installation, testing and commissioning of VRLA battery bank of 360V, 65AH (12 V X 65AH X 30Nos) as per TSS-11
Supply, installation, testing and commissioning of 12V, 180AH Battery for DG set as per TSS-12
Maintenance of 3 HP Mono block pump 2Nos X 4 Times= 8Nos)as per TSS -13
Repairing of faulty summersible borewell pump of 10HP per TSS -14
Rewinding of 3HP LT motor as per TSS -15
Rewinding of 10HP LT motor as per TSS -16
Maintinance of electrical lighting fixtures and power points of various rating (100 Nos X 4 times=400Nos) as per TSS- 17
Maintenance of Earthing pits staion (15Nos X 4times=60nos) as per TSS -18
Maintenance of Lightening Arrestor (30Nos X 2 Times= 60 Nos) as per TSS-19
Supply, installation, testing and commissioning (SITC) of 40W LED street lights as per TSS -20
Supply, installation, testing and commissioning of 36W LED 600x600 recess lighting fixture as per TSS- 21
Supply, installation, testing and commissioning of 3kW instant geayser as per TSS-22
Supply, installation, testing and commissioning of 16A switch as per TSS-23
Supply, installation, testing and commissioning of 6A switch as per TSS-24
Supply, installation, testing and commissioning of 6/16A socket as per TSS-25
Supply, installation, testing and commissioning of 6A socket as per TSS-26
Supply, installation, testing and commissioning of 4 Module surface mount PVC box with face plateas per TSS-27
Supply, installation, testing and commissioning of 8 Module surface mount PVC box with face plateas per TSS-28
Supply, installation, testing and commissioning of Chemical Earthing stations as per TSS-29
Supply installation testing and comissioning of 80mmX50mm PVC Trunking as per TSS-30
Supply installation testing and comissioning of LED, 20W Indoor Aluminium body Batten Type Lighting Fixture as per TSS-31.
Supply installation testing and comissioning of LED, 40 W Outdoor Extruded metal body street Lighting Fixture as per TSS-32
Supply installation testing and comissioning of LED, 30 W 2ft X 2ft Indoor recess/Surface indoor Lighting Fixture as per TSS-33
Supply installation testing and comissioning of BLDC ceiling fan with sweep 1200mm as per TSS-34
Metal surface painting with supply of materials as per TSS-35
Excavation of Soil as per TSS-36
Supply and installation of MS Fabricated items as per TSS-37
Preparation of SLD drawing of electrical distribution system of the facility as per TSS-38
Stenciling of all Panels, DBs, Power Poing and switchbox points as per TSS-39
Underground cable laying as per TSS-40
Arathi Electricals (BID ID -3159925)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .