Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.1 LAccepted-AOC 1 1 MEREDITH STREET KOLKATA 700072 INDIA | KOLKATA | WEST BENGAL | 700072 | L-1 | Accepted-AOC ACCEPTED | |
| 2 | L-2₹25.7 L+₹2.3 L (9.83%)Rejected-Finance | L-2 | Rejected-Finance Being higher bid value | |
| 3 | L-3₹26.0 L+₹2.6 L (11.1%)Rejected-Finance 117 LENIN SARANI KOLKATA 700 013 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700013 | L-3 | Rejected-Finance Being higher bid value | |
| 4 | L-4₹26.6 L+₹3.2 L (13.8%)Rejected-Finance 28 H TOLLYGUNGE CIRCULAR ROAD KOLKATA 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L-4 | Rejected-Finance Being higher bid value | |
| 5 | L-5₹26.7 L+₹3.3 L (14.1%)Rejected-Finance 53 TOLLYGUNGE CIRCULAR ROAD KOLKATA 700 053 | KOLKATA | WEST BENGAL | 700053 | L-5 | Rejected-Finance Being higher bid value |
Tender Value
₹24.2 L
EMD Value
₹48,400
Closing Date
7 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alipore Kolkata
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
SPL REPAIR TO COOK HOUSE, DINNING HALL AND OTHER CONNECTED STORES ROOMS OF HQ RTG ZONE, KOLKATA UNDER GE (A) KOLKATA
2024_MES_637831_1
GE/ALP(8297B) KOLKATA OF 2023-24
Open Tender
Civil Works - Canal
Item Rate
180 days
GE Alipore Kolkata
CLASS E and Category a (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer Alipore
₹48,400
Yes
GE Alipore Kolkata
21 Feb 2024
17 Jan 2024
14 Feb 2024
17 Jan 2024
7 Feb 2024
31 Jan 2024
17 Jan 2024 - 24 Jan 2024
25 Jan 2024
Amount
Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbing down with water etc complete all as specified and directed.(upto four storiey bldg)
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each complete all as specified and directed.
Taking down of steel window with guard bar complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each and removing from site complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings n. exc 15 cm thickness (below or above ground level ) complete all as specified and directed.
Demolition of brick work built in cement mortar including all quions, arches, pillers etc complete all as specified and directed.
Dismantiling of floor hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises (out of MOD land) complete all as specified and directed.
Dismantling wrought iron or mild steel works of any description not otherwise provided for
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) of insulation boards/slabs/blankets, any thickness, including cover fillets complete all a specified and directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (up to four stories bldg) complete all as specified and directed.
Dismantiling of plain or corrugated,semicorrugated steel sheeting any gauge,thickness,including Nainital or similar pattern in roof coverings and rubbish off the premises (outside of MOD land), complete all as specified and directed.
Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Material and labour for brick work with sub class 'B' bricks straight or curved on plan or to any radius in half brick work built in CM 1:4 complete all as specified and directed.
Material and labour for rendering 15mm thick in CM (1:4) on other than fair face of brick work or concrete surfaces and finished the surface even and smooth completeall as specified and directed.(upto four storie bldg)
Material and labour for 15 mm thick cement plaster (1:6) on fair faces of brick work or concrete surfaces complete all as specified and directed.(upto four storey high bldg)
Material and labour for glazed ceramic tiles of size 450x300x7-8mm thick in verticle surfaces set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles laid over and including 10mm thick cement plaster in cement mortar (1:4) complete all as specified and directed. .
M&L for 25mm thick PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in bedding of tiles/kota complete all as specified and directed.
M&L for light shade vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles n. exc 0.36 sqm over and including 15 mm thick screed bed in CM (1:6) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match .
Material & labour for framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-16.
S&F for powder coated aluminium sliding windows for three track with rubber gasket, stopper powder coated aluminium standard beads/glazing clips ,locking arrangement etc and aluminium frame of size 80mmX25mmX1.55mm and shutter of section 20mm X20mm X1.55mm incl ( two shutter of 4.8mm thick glass and one shutter of wiremesh 0.36 mm dia of wire and average width of aperture 1.40 mm) including aluminum chequered grill with necessary all fittings complete all as per manufacturer's instructions and all as specified and directed.
Supply and fixing for stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of apperture 1.40 mm and fixed with stainless steel staples in steel/wooden /aluminium frames all as specified and directed.(upto four storied bldg )
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal.
Taking up or down 25mm bore steel tubing and connections, including cleaning for re-fixing or removal.
S&F for 15mm bore steel tubing medium grade galvanised with all fittings fixed to wall and ceiling complete all as specified and directed.
S&F for 20mm bore steel tubing medium grade galvanised with all fittings fixed to wall and ceiling complete all as specified and directed.
S&F 25mm bore steel tubing medium grade galvanised with all fittings fixed to wall and ceiling complete all as specified and directed.
Supplying and laying for 25 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls including all brass fitting/fixtures in any grade to receive plumbing fittings and fixtures complete all as specified and directed
Supplying and laying for 32 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls including all brass fitting/fixtures in any grade to receive plumbing fittings and fixtures complete all as specified and directed
M&L for cutting chases, pinning, in making good to facing where required of of brick wall and pointing in cement motrar (1:3) to ends and cutting chases for concealed water tubing and concealed conduit wiring etc and making good surfaces complete all as specified and directed.
S&F in powder coated aluminium fixed portion (Squre or circular) of frame size 80mm x 38mm x 2.00 mm with standard beads/glazing clips, locking arrangement etc any shape and size with necessary all fittings complete all as per manufacturer's instructions and all as specified and directed.
M&L for 9 mm thick prelaminated partilce boards interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screw to timber frame for pelmet boxes,aluminium door and aluminium partitions complete all as specified and directed.
S&F for 4.8 mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area of glass not exc 0.5 sqm each pane.
M&L for granite slab 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, walls, window- cills, cooking platforms over and including screed bed/plaster 15 mm thick in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.(upto 10 storey High of building)
Supply and fixing for curtain rods decorative aluminium alloy with fixing brackets including taking down old pelmet box making wood on wall complete all as specified and directed. (upto 4 storey of building)
Supply and fixing for bracket decorative type for curtain rods aluminium alloy complete all as specified and d9irected. (upto 4 storey of building)
S&F 1000 ltr capacity rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed including taking down existing water tanks complete all as specified and directed.
S&F for 500 ltr capacity rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed including taking down existing water tanks complete all as specified and directed.
S&F for water tank lid for 500/1000 Ltrs capacity PVC tank
S&F for pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall,fixed with self tapping srews all as specified and directed.
S&F for pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall for rain water pipe ,fixed with self tapping srews all as specified and directed.
S&F for MS Plates (plain or chequered) square cut or notched (forming holes with riveted,bolted attechment) 300x300x8 at bottom & 200x200x8 at top GDE Fe 410-S
S&F for steel work in tubular truss and tubular post including special shaped washer etc .complete using ERW or induction butt welded tubes conforming IS:1161-1979 grade St-240
S&F for MS rolled section as in roof purlins, rafters and truss etc of MS pipe fixed with iron cleats along with nuts & bolts of required size or section or welded conforming to Fe-290 Gde E-165.
Supply and fixing for MS screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be be fitted with washers and one hexagonal square nut length of bolt exc 15 cm but n. exc 22.5 cm complete all as specified and directed.
S & F for MS screw bolts (machine made) with hexagonal or square heads at one end and screwed the other,or screwed both ends,each screwed end to be fitted with washers and one hexagonal or square nut,but lenth of bolt exc 5 cm but n exc 10 cm
Material and labour for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.(upto four storey bldg)
From work edges of concrete not 10 cm but n.exc 20 mm in rough finished surface.
Material and labour for form work to soffit of suspended slab such as roof slab n.exc 20 cm thick for rough finished of roof complete all as specified and as directed.
M&L for RCC (1:2:4) type B1, (using 20 mm graded stone aggregate) as in roof slab supported to wall, slab ,shelves and the like complete all as specified and directed.
Supply and fixing in repair 15mm bore bib taps cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and directed.
S&F in repair 15mm bore brass CP angular stop cock concealed type with crutch or butterfly handle complete all as specified and directed .
Supply and fixing in repair for 15mm bore chromium plated pillar tap fancy type cast copper alloy, with capstan heads screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
Supply and fixing in repairs vitreous china wash basin ( white), flat back, size 580 x 450 mm including CP waste coupling 32mm dia excluding taps, waste,chain and plug and porcelain stopper but including brackets, complete all as specified and directed.
supply and fixing in repair 32mm dia flexible PVC waste pipe for basin etc complete all as specified and directed.
M&L for anodised aluminium snap grid frame work for false ceiling all as specified and directed .
M&L for hanger 6mm dia GI (upto 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flate 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and directed.
Supply and fixing for 6 mm thick non esbestor fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws complete all as specified and directed.
S&F for gun- metal, globe or gate valves 20 mm dia of pipe with iron wheel head,screwd both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair stainless steel kitchen sink 1mm thick with plug, waste pipe. washers including cantilever cast iron brackets, connecting union etc over all size 915mm x 460mm with bowl size 410mm x 330mm x 160mm complete with fixing accessories and fixed in position all as directed at site
Material & labour for preparation of new plastered surfaces of wall and applying two coats of oil bound distember over a coat of primer complete all as specified and directed.
Material & labour for preparation on new plastered surfaces of wall and applying two coats of anti-algae and anti-fungal exterior grade weather coat paint over a coat of primer complete all as specified and directed.(upto four storey bldg)
Material & labour for preparation of old decorated surfaces of wall and applying one coat of oil bound distemper complete all as specified and directed.(upto four storey bldg)
Material & labour for preparation of old decorated surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds,etc and applying one coat of anti-algae and anti-fungal exterior grade weather coat paint complete all as specified and directed.(upto four storey bldg)
S&F for 110mm bore PVC(SWR) pipe single socket in any length rubber ring joints complete all as specified and directed.
S&F for 110mm bore PVC(SWR) pipe bend single socket complete all as specified and directed.
S&F in repair CI nahani trap of 100mm dia, including jointing to waste pipe fixed in cement concrete, (1:2:4), type B1 ( using 20 mm graded crushed stone aggregate) complete all as specified and directed.
S&F in repairs CP grating of 100mm dia, fixed with cement mortar (1:3).complete all as specified and directed.
Supply & fixing for 2nd class hard wood plain solid straight chowkhats and frames, wrought, framed rebated on the solid rounded or chamferred put together with glue, pinned at joints complete all as specified and directed.
Supply & fixing for 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F for 35mm thick 2nd class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc (wihout sash bars), edge of framing plain, chamferred or rounded, fitted with cut and mitred beads for securing glass etc sizes of memebers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed.
Supply and fixing in repair for 18/19mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice laminations and other side balancing white lamination fixed with screws to timber frame work as in kitchen cabinet shutter including external teak wood lipping 6mm thick fixed with nails complete all as specified and directed.(upto 12 storied bldg).
Supply and fixing in repair for 18/19mm thick block boards, grade 2 quality,interior grade, decorative type with decorative face veneer on both face fixed with screws to timber frame work as in cupboard shutter, Kitchen cabinate, work station etc including external teak wood lipping 6mm thick fixed with nails complete all as specified and directed.
Supply and fixing in repair for 0.9mm thickess of decorative laminated type 1 of surfaces finish,colour and pattern as approved fixed with approved adhesive as per manufacture,s instruction complete all as specified and directed.
Supply and fixing for 30mm width of flap continious piano hinges mild steel,bright finish or electro galvanised complete all as specified and directed.
S&F in magnetic catches 50 mm long of any description
Supply and fixing for 40mm dia cupboard knobs of brass fixed with nut, screw and washer complete all as specified and directed.
Supply and fixing for 75mm hasp and staple, safety type brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F in repair 6mm thick plywood in cupboards complete all as specified and directed.(upto 12 storied bldg)
S&F in repair for 2nd class hard wood plain fillet of size exc 13 but n.exc 25 Sq cm, rectangular or square in section, clean sawn, secured with nails or beads complete all as specified and directed.(upto 12 storied bldg).
M&L for applying evenly a tack coat of industrial bitumon 85/25 at the rate of 1.2 kg per sqm including cleaning surface on roof surface for fixing APP membrane complete all as specified and directed. (upto 12 storey High of building)
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid over bitumen coated surface of roof applied with propere torch flames all as per manufactures instruction. NOTE:- The APP membrane will have an overlaping of 100 mm on the end laps and 150 mm on side laps. The overlaping and joints will be thermo sealed with the propere torch complete all as specified and directed.(upto 12 storey High of building)
M&L for applying protective coating with aluminium paint @ 0.2 kg/sqm complete all as specified and directed.(upto 12 storey High of building)
Material & labour for PCC 1:3:6, type C1 (using 20mm graded stone aggregate) as in bed blocks for hold fast including making good or disturbed portion with plaster to match with existing surface complete all as specified and directed.
Supply & fixing for 100mm long butt hinges medium weight, cold rolled mild steel complete all as specified and directed.
Supply & fixing for 300 mm long aluminium anodised , barrel tower bolts of extruded section complete all as specified and directed.
Supply & fixing for 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F for 300mm long aluminium alloy anodised sliding door bolts and hasp and staple (Bolt type) and fixing clips of sheets cast or extruded sections and fixing bolts and sliding bolts or extruded section ot cast alum alloy and fixed .
M&L for preparation of new or previous untreated wood and wood based surfaces of any description over 10 cm girth or width not otherwise described and applying two coats of synthetic enamal paint over a coat of pink primer complete all as specoified and directed.
M&L for precast cement concrete (1:2:4), type B-1(using 20mm graded stone aggregate) as in cover slab, shelves, and similar work set in CM (1:4) complete all as specified and directed.
M&L for mild steel TMT bars 8 to 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M&L for providing factory made 75 mm thick precast RCC cover slab of 3 MT load bearing capacity confirming to IS : 12592 (Grade M-30) complete all as specified and directed.
M & L for cement concrete 1:3:6,type C1 (using 20mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings/hold fast, kneelers, apex stones, bed plates, kerbs water troughs and the like including or chamfered angles and throating, complete all as specified and directed
Excavation in trenches not exc 1.5 mtr wide and not exc. 1.5 mtr deep for foundation in soft/loose soil complete all as specified and directed.
Demolition and breaking up 150mm dia drain pipes (salt glazed stoneware AC or reinforced concrete drain pipe) jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
M&L for concrete bed for 150 mm bore pipe in PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) to drain pipes including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for 150 SGSW drain pipes laid in trenches and jointed complete all as specified and directed.
Returning filling in trenches including spreading leveling and well ramming with water complete n.exc 25 cm thick in each layer in soft/loose soil complete all as specified and directed.
Removing exavated soild n.exc 50 mtr and depositing where directed at a leve n. exc 1.5 mtr above the starting point.
M&L for 75 mm thick PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for machine preesed precast concrete glazed interlocking paver block any shape and size over sand/stone dust cushion confirming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement and pigment complete all as specified and directed.Note:- Sand cushion shall be measured and paid separeatly.
M & L for supply only sand cushion below paver block for levelling complete all as specified and directed.
M&L for coloured rubber polished chequered tiles with grey cement and no pigment 30cm x 30 cm x 25mm thick , over and including 15mm thick screed bed in CM 1:6, set jointed and pointed in neat cement slurry in floors complete all as specified and directed.
Cutting into exisiting manholes 150mm dia for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4, type B-1 smooth finished and reforming benching as required complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light,fan,socket etc.) complete including fittings such as switch, ceiling rose, light fittings, regulators etc. and making good to the disturbed surface of walls, floors etc. complete all as specified and directed.
M&L for point wiring for one light/ bell/ fan controlled by one number one way switch for light/fan complete with 1100V grade FRLSH PVC insulated unsheathed multistranded copper conductor cable conforming to IS : 694 of size 1.5 Sqmm two runs single core for phase and neutral drawn through in and including PVC concealed conduit of suitable size (minimum 20mm dia medium grade ISI Marked) complete with one run of 1100V grade FRLSH PVC insulated multistranded copper conductor cable 1.5 Sq mm single core green colour for earth continuity conductor and connecting to common earth dolly including provn of modular type galvanized MS sheet pressed sunken box not less than 1.00 mm thick concealed on wall including fixing of modular cover plate of suitable modules with fixing screws, for fixing of modular type switches / socke t/ fan regulator etc. complete including making good of disturbed surfaces of wall/ceiling/floor in same specification as per existing surrounding surface complete all as specified and directed.
All as per item No. 108 above but for 5 amps socket on same board complete all as specified and directed.
All as per item No. 108 above but for 5 A socket point on independent board complete all as specified and directed.
All as per item No. 108 above but for 15 A socket point independent with 2.5 sqmm 1100V grade FRLSH PVC insulated copper conductor complete all as specified and directed.
All as per item No. 108 above but for AC Point independent with 4.0 sqmm 1100V grade FRLSH PVC insulated copper conductor complete all as specified and directed.
S & F for ceiling rose, 3 terminal, PVC/ polycarbonate isolated body, 230 V.
S & F for modular type switch, one way 6 Amps , 1 module complete Make:-Legrand/Anchor(Roma)/Crabtree
S & F for modular type socket 5 pin, 6 Amps 2 module complete .Make:-Legrand/Anchor(Roma)/Crabtree
S & F for modular type socket 5 pin, 16 Amps 2 module complete Make:-Legrand/Anchor(Roma)/Crabtree
S & F for modular type switch, one way 16 Amps, 1 module completeMake:-Legrand/Anchor(Roma)/Crabtree
M & L for taking down exhaust fan and refixing the same after completion of E/M & B/R works complete all as specified and directed.
M & L for making/reparing the hole for fixing the exhaust fan of size 450 mm complete all as specified and directed.
Taking down the existing tube light fitting and fixing the same after completion of B/R and E/M works and all as directed by Engg-in-charge
Dismantling and taking down carefully sub-main wiring any size including wooden batten etc and making good the disturbed surfaces of wall/ floor to match the existing wall/ floor etc complete all as specified and directed.
Material and labour for of sub-main wiring with two runs of 1100 V grade FRLSH PVC insulated & unsheathed 6.0 Sqmm single core multi stranded copper conductor cable alongwith one run of 6.0 Sqmm 1100 V grade PVC insulated & unsheathed single core multi stranded copper conductor cable for earth continuity conductor connected to common earth dolly, drawn through concealed PVC conduit complete all as specified and directed. Note : (i) Three runs of 6.0 Sqmm cable shall be measured as one length.
S&F for LED tube light fitting 4 ft 20 watt, 230 volt energy efficient comprises of extruded PVC housing, with inbuilt driver and PC diffuser including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make: Bajaj/Crompton/Havells
Supply and fixing for TPN MCB DB 4 way with 200 Amps rated bus bar, neutral link, dinrail suitable for mounting MCB's 240 volts double door type as in repair of busbar for distribution of power and light circuit including taking down old bus bar box and making good the disturbed surface complete all as specified and directed . Make : ABB /Legrand/ Havells/L&T/Schineider/C&S.
Supply and fixing for MCB TPN 63 AMP 415 Volt "C" series, breaking capacity 10 KA as incomer complete all as specified and directed. Make : ABB /Legrand/ Havells/L&T/Schineider/C&S.
Supply and fixing for MCB 06 Amps to 32 Amps, single pole, 240 Volt "C" series, breaking capacity 10 KA complete all as specified and directed.Make : C&S /Legrand/ Havells/L&T/ABB.
Supply and fixing for MCB 32 Amps, SPN, 240 Volt "C" series, breaking capacity 10 KA complete all as specified and directed. Make : C&S /Legrand/ Havells/L&T/ABB.
Supply and fixing for SPN MCB DB 8 way with Amps rated copper bus bar, neutral link, suitable for mounting MCB's 240 volts double door type including taking down old one and making good the disturbed surface complete all as specified and directed. Make : ABB /Legrand/ Havells/ L&T/ Schineider/ C&S.
Supply and laying/fixing on wall with GI clamp under ground heavy duty XLPE insulated, armoured aluminium conductor cable 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core in trenches / through pipe in road crossing / plinth/ drain/ duct/ floor along pole / wall /ceillings etc after and including disconnecting and taking out existing unserviceable cable complete all as specified and directed.
S&F for GI pipe light grade 50mm tubes, 'light grade'' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed
S & F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with inbuilt driver, suitable for roof ceiling including connecting up with driver three core flexible copper conductor wire of suitable size complete all as specified and directed. Make : Crompton , Cat No. : LCTLRNE-36-FO-CDL Havells (CAT No- VENUSNEOHE4x1PLR36WLED8576)/ BAJAJ(CAT No-BZRSQL 36L LED GX NW)
S & F for modular type 32 A motor starters (for AC) white colour, Make crabtree/ Havells/ Legrand/ North west/ Anchor (ROMA)
S & F for LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
KAY BEE ASSOCIATES
BHARUKA ENTERPRISES
CONSTRUCTION AND MAINTENANCE ENGINEERING CORPORATION
S.S.ENTERPRISE
Rounaq Enterprise
Tirupati Buildcon Pvt. Ltd.
RAJ ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .