Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹65.8 L+₹1.4 L (2.11%)Rejected-Finance 14 SHREE GOPAL NAGAR GOPALPURA JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | L2 | Rejected-Finance Due to L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | - | Not Admitted-Fee/PreQual/Technical Others-experience certificate of required amount is not attached. | |
| 4 | Not Admitted-Fee/PreQual/Technical 21 333 031 | JHUNJHUNU | RAJASTHAN | 333031 | - | Not Admitted-Fee/PreQual/Technical Others-experience certificate of required amount is not attached. |
Tender Value
₹66.7 L
Closing Date
23 Jul 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AO
CSIR CEERI PILANI
Repair of quaters No. F-48 to F-71 at CSIR-CEERI, Pilani
2021_CSIR_82084_1
14/440/2021-CE
Open Tender
Civil Works
Item Rate
150 days
PILANI
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
2 Sept 2021
15 Jul 2021
26 Jul 2021
15 Jul 2021
23 Jul 2021
15 Jul 2021
90 days
Amount
Part A: Civil Work Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand),having below rough plaster of avarage 20 mm of 1:4 (1 cement : 4 coarse sand) for surface prepration and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets
20 mm dia (heavy type)
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete
Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete.
300 mm weighing not less than 200 gms
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete Including taking out old one as per the direction of the Engineer-in-charge
With 2nd class teak wood beading of suitable size
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design
In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : including cutting wall for fixing stone upto 50mm deep in wall & repairs as per the direction of the Engineer-in-charge
White sand stone slab 40 to 50 mm thick
Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 fine sand)
Stone ware spout
12 mm cement plaster including proper double scaffolding system of mix
1:6 (1 cement : 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall proper double scaffolding system of mix
1:6 (1 cement : 6 coarse sand)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Applying priming coat:
With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood).
Removing white wash,dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :
Old work (one or more coats)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
One or more coats on old work
Renewing of
glass panes, with putty and nails wherever necessary including racking out the old puttyFloat glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
Old putty of glass panes (length)
Taking out existing wooden/steel door and window shutter & frmaes, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required and proper closing and locking system by sawing, chiseling, plaining, tightening, hammering,welding etc. new screws/nails, nuts and bolts etc all complete as per the direction of the Engineer-in-charge
Demolishing cement concrete manually/ by mechanical means including disposal of material within CEERI Campus as per direction of Engineer - in - charge
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within CEERI Campus as per direction of Engineer-in-charge
In cement mortar
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within CEERI Campus
75 to 80 mm dia pipe
100 mm dia pipe
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within CEERI Campus as per direction of Engineer-in-charge :
15 mm to 40 mm nominal bore
Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within CEERI campus as per direction of Engineer-in-charge
Up to 150 mm diameter
Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within CEERI campus as per direction of Engineer-in-charge
Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within CEERI campus including refilling the excavated gap as per direction of Engineer - in - charge
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within CEERI campus as per direction of Engineer - in - charge
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within CEERI campus as per direction of Engineer - in - charge
Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars disposal within CEERI Campus as per direction of Engineer - in - charge
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required
Kitchen sink without drain board 610x460 mm bowl depth 200 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete
Flexible pipe 32 mm dia
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing
Rectangular shape 450x600 mm
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete
Providing and fixing soil, waste and vent pipes
100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
75 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete
75 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing plain bend of required degree
100 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
75 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete
100x100x100x100 mm Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
75x75x75x75 mm Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing terminal guard
100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe
100 mm dia SS 304 grade coupling with EPDM rubber gasket
75 mm dia SS 304 grade coupling with EPDM rubber gasket
Providing and fixing M.S. stays and clamps for sand cast iron /centrifugally cast (spun) iron pipes of diameter
100 mm dia
75 mm dia
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors
100 mm inlet and 75 mm outlet Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc
15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall
15 mm dia nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete
15 to 40 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
20 mm dia nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions
45 cm length 15 mm nominal bore
Providing and fixing C.P. brass shower With Shower Arm &Wall Flange OF 15 or 20 mm inlet of approved quality and design as per direction of Engineer - in - charge
100 mm diameter
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)
15 mm dia nominal bore
20 mm dia nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
15 mm dia nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms
15 mm dia nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15 mm dia nominal bore
Cutting holes up to 30x30 cm in walls including making good the same:
With common burnt clay F.P.S. (non modular) bricks
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete
100 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design
100 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete
For pipes 100 to 250 mm diameter
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Dismantling EWC/Indian WC, wash basin with brackets, mirror glass self & bib cock, stop cock etc. with all fittings in one complete toilet including depositing in central store as per direction of Engineer-in-charge 15mm to 40 mm nominal bore
Taking down GI Pipes including fittings & cleaning for following diameters and depositing in central store as per direction of Engineer-in-charge 15 mm to 25 mm nominal bore
Refixing old GI pipe including fitting (new) as per direction of Engineer-in-charge of the following sizes 15 mm to 25 mm nominal bore
Providing and fixing CP Brass Towel rail of size 600mmx20mm with brackets fixed to wooden cleats etc. complete including removing the damaged towel rail and depositing the same as per direction of Engineer-In-Charge.
Taking out sinder from sunken floor of toilet including proper stacking including refilling the same with proper campaction as per direction of Engineer-in-charge
20 mm cement plaster on roof including of mix 1:4 (1 cement: 4 coarse sand) including admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. The whole terrace so finished shall beflooded with water for a minimum period of two weeks for curing and for final test as per direction of Engineer-in-charge
Repair of existing broken RCC corners of chajjas, railings, projected areas, shelves by chiseling the existing surface, removing of loose materials and repairing the same with cement concrete 1:2:4 and plastering with Cement motar 1:4 and finishing as per existing as per direction of Engineer-in-charge
Providing and fixing 35mm thick panelled / glazed shutters for doors and window frames made of hollock wood/shisham wood and 12mm thick water proof ply paneling as per the design existing in the colony including MS but hinges, screws and removing the old shutters and depositing same as per direction of Engineer-in-charge
Repairs of reveals and jambs of doors and windows with cement mortar 1:3 (1 cement : 3 fine sand) including chiseling the damaged area and disposal of mulba in low laying area in CEERI Campusas per direction of Engineer-in-charge
Welding of square/round MS bars/welding to existing articals where it is broken as per direction of Engineer-in-charge
Providing and fixing MS window handles with washers, nuts & bolts etc. complete as per direction of Engineer-in-charge
Providing and fixing steel glazed windows and ventilators, side /top /centre hung, with beading & putty and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including fly proof stainless steel grade 304 wire gauge standred size and 4 mm thick glass pans, priming coat,handles,peg stays of approved steel primer etc, fittings, complete all as per approved design, including repairs existing revaels &jambs etc Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per direction of Engineer-in-charge
Taking down PVC tanks of 500 ltr capacity and including refixing the same complete with New 20mm brass float valve if broken to be deposited CEERI Store yardas per direction of Engineer-in-charge
Part B: Electrical Work Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group-A ( Irrespective of any length)
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying & fixing call bell/ ding dong suitable for single phase ,230 volts on the existing box/wooden block including making connections etc. as requierd.
Wiring for circuit/ sub main wiring alongwith earth wire with following sizes of FRLS PVC insulated copper conductor, single core cable of 1.1kv grade in surface/ recessed medium class PVC conduit, making connections, testing etc as required.
2 x 2.5 Sq.mm +1 x 2.5 Sq.mm
2 x 4 Sq.mm +1x 4 Sq.mm
2 x 10 Sq.mm + 1 x 6 Sq.mm
P & F ISI marked flush type 120/280 watt rotary step fan regulator two module including making connection testing etc. as required.
Supply of XLPE insulated PVC sheathed 1.1 kv. Grade Aluminium conductor armoured Cable, IS marked of approved make.
4 x 35 Sqmm.
Laying of PVC/ XLPE insulated PVC sheathed of 1.1 Kv grade with aluminium conductor armoured cable in ground as per IS:1255 including excavation of 30cmx75cmsize trench, 25cm thick under layer of sand, II nd class brickes covering refilling earth, compaction of earth, making necessary both side connections testing etc. as reqd.of following sizes.
upto 35 Sqmm.
Laying of cable as per specification of above item on wall, pole or surface including fixing with wooden plugs as per approved spacings by means of screws & rag bolts, M.S.U. clamps etc complete as per specifications including making connections and testing etc
upto 35 Sqmm.( clamped with 1mm thick saddle)
Laying of one number cable as per specification of above in the existing RCC/ hume/ Stoneware/ Metal pipe including making connections both side and testing etc as rqd.
upto 35 Sqmm.
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 35 sq. mm (32mm)
Supplying and making outdoor end termination with heat shrinkable/cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 35 sq. mm
Dismantling of PVC/ XLPE insulated armoured LT cable, 1.1 KV grade from under ground after disconnection of supply connections including digging trenches up to 1.2mtr depth and return back the same to store etc. as required.
Up to 70 sqmm.
Dismantling of PVC/ XLPE insulated armoured LT cable, 1.1 KV grade from surface of wall/ pole/ pipe including disconnection of connections, clamps and return back to store etc.
Up to 70 sqmm.
Cutting road/ Cement floor and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening/ Cement, red bajri and labour required.
Plate Earthing as per IS: 3043 with copper earth plate 600 x 600 x 3 mm thick by embodying 4 mtr below the ground lavel with alternate layers of salt and charcoal (95 kg. each) with 20 mm dia G.I. B class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete and testing of earth resistance as required.
Supplying & Laying 25mm x 3mm copper strip at surface/recess including riveting, soldering, saddles or 0.50 meter below ground as strip earth electrode, including connections terminating with nut ,bolt,spring, washer etc.as requierd. (Jointing shall be done by overlapping & with 2 sets of brass nut bolt & spring washer) duly soldered or crimped etc. as required
S & Laying following size' A' class G.I. Pipe with accessories for laying earth conductor/strip in ground/surface/recess as required.
40 mm dia.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required.
P & F of heavy duty capacitor start Exhaust fan Size-300 mm sweep, 900 RPM, single phase, IS: 2312 marked of Havells make model-Turbo force SP or other approved make in existing opening including grouting of metal fastener with bolts, nuts making connections , testing etc. as reqd.
P & F of gravity louver shutter of superior quality made out of frame of 18 SWG MS sheet & louvers made from 24 swg Al. sheet with nut bolts enamel paint etc as required. Size Up to 380mm.
Making hole in wall of required size for housing exhaust fan of Size - 300 mm sweep and making good the damages with cement morter etc. as required.
Dismantling of all type of existing wiring upto 4Sq.mm size with batten /casing/ conduit including fittings i.e. bulb holder/ ceiling rose /lamp bracket deposit the same to centrel store (measured batten/casing/condiut length as single run only )
Labour charges for dismantling of surface/ recessed light/ power point switch board of any size and depositing the same with listing of material in store.
SITC of wall mounted dust and vermin proof, compartmentalised cubical panel made out of CRCA sheet, required hardware, duly painted by powder coating with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable gland plate, fixing of glass for observe meter reading without opening the hinged door with locking arrangement for equipment/ switchgear/ busbar chamber/ cable alley . Thickness of sheet shall not be less than 2.0mm of any compartment. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls compartments having bolted type doors with detachable extension type structure. S/F of following accessories and their inter connections with lugs, terminating all the outgoing and incoming supply terminals in cable alley fixed on SMC/DMC type insulators/ suitable size connectors (as per requirement) with suitable size copper strip with heat shrinkable PVC sleeves/ wire, testing etc as required.( area of board not less than 3.38sqmtr. also only outer area of board should be measured).(Panel should be fabricated & assembled as per attached drawing through electrical panel builders and delivery challan should be produced along with panel)
a) 1No- quick make and quick break 4 Pole current limiting MCCB 125 Amp., 30 KA adjustable O/L & fixed S/C setting with Thermal Magnetic Release and conforming to IS:13947-2/ IEC 60947-2 with front face and centralized adjustable, line load inter changeability including making connections with lugs/ spreaders, Direct rotary handle etc. as required for incoming circuit. b) 1 Set – 200 A, 4 strips copper busbar of suitable length, fixed on SMC/DMC type insulators & colour coding with heat shrinkable PVC sleeves c) 1Set 240/220 volts pilot lamps with intenral circuit, terminal block ,including 3 nos. SP MCB 0-5AMP. "B" curve,10 KA, 415 V. grade of approved make for 3- phase supply, making connections with lugs, testing for incoming circuit etc. d) 5Nos..Double Pole, AC MCB 32 Amps, 415 V, 10KA with "C" breaking capacity,ISI marked IS:8828(1996) including making connections with lugs, testing etc. for outgoing circuits. e) 5Nos. Single phase, two wire solid state (static) fully electronic energy meters of accuracy class 1.0 & current rating 10-60 A, with backlit LCD display for 240 Volt systems, direct operated type, 50Hz having resolution 0.1kwh, led indicator for temper operation and meter sealing as per IS: 13779 etc. as required. f) 6sets suitable size SP&N terminal connectors for outgoing circuits with suitable size FRLS PVC insulated copper conductor up to terminal blocks, to receive XLPE aluminium/ copper cable/10 Sq.m copper wire of 1.1KV grade for outgoing ckts.
Fixing of existing 8 way(2+6 way) single phase, double door MCB-DB complete with its all existing accessories, MCBs/ RCCB etc. recessed to the wall including cutting and making good the wall, making connections, testing as required.
Dismantling of existing wall/ floor mounted Main Switch board safely from the wall/ floor with all accessories, meters, frame/ wooden board, inter connections including repairing wall / floor etc. and return back the dismantled items/ accessories of boards to store/ EME Div. are as follows.
Board with 1No. 60/100A main switch, 1 set 4strip busbar, 4Nos. 25/ 40A DP RCCB, and all other accessories like- 4/5 Nos. energy meters, inter connections etc. as required.
New Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .