| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹43.2 L+₹5.5 L (14.7%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted than L1 | |
| 3 | L3₹43.9 L+₹6.2 L (16.4%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted than L1 | |
| 4 | L4₹44.0 L+₹6.3 L (16.6%)Rejected-Finance | L4 | Rejected-Finance Higher rate quoted than L1 | |
| 5 | L5₹45.1 L+₹7.4 L (19.6%)Rejected-Finance SOUTH CANEL PAR PO PANAGARH BAZAR DISTT PASCHIM BARDWAN WB PIN 713148 | PANAGARH BAZAR | PASCHIM BARDWAN | WEST BENGAL | 713148 | L5 | Rejected-Finance Higher rate quoted than L1 |
Tender Value
₹49.4 L
EMD Value
₹98,900
Closing Date
21 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_546523_1
8400-845/E8
Open Tender
Civil Works
Works
210 days
PANAGARH
Class D and Category a (i) (Building)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹98,900
Yes
29 Nov 2022
20 Aug 2022
23 Sept 2022
20 Aug 2022
21 Sept 2022
6 Sept 2022
Amount
Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc. in soft / loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and exc 1.5m but n.exc 3.0 m in depth for foundation etc. in soft / loose soil complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) in foundation filling and mass concrete complete all as specified and directed.
M&L for RCC (Design Mix) M-25 (using 20mm graded stone aggregate), in foundations, footings, foundation beams, plinth beams, bases of columns and mass concrete complete all as specified and directed.
M&L for RCC (Design Mix) M-25 (using 20mm graded stone aggregate), in columns, pillers, piers, post and struts complete all as specified and directed.
M&L for RCC (Design Mix) M-25 (using 20mm graded stone aggregate), in in Beams, cantilevers, lintels over 1.5m span complete all as specified and directed
M&L for formwork to sides concrete foundations, bases of columns, sides and soffits (if any) of foundation and plinth beams, and similar work complete all as specified and directed.
M&L for formwork to sides piller post ,struts, and columns and similar work complete all as specified and directed.
M&L for formwork to sides and soffits of lintel / lintel band for flat and rough finished surface of concrete complete all as specified and directed
M&L for TMT deformed steel bars 8mm dia & over, cut to length, bend to shape required including cranking, bending and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and directed.
All as per item No 11.00 mentioned here-in-above but 8mm dia in stirrups complete all as specified and directed.
M&L for damp proof course 40mm thick in cement concrete 1:2:4 type B-0 to horizontal or vertical surfaces including necessary form work complete all as specified and directed
M&L for fly ash brick straight or curved on plan exc 6 mtr mean redious built in CM (1:6) complete all as specified and directed
M&L for 15mm thick rendering in CM (1:6) on internal surfaces of brick masonry wall finished even and smooth without using extra cement complete all as specified and directed
M&L for 15mm thick rendering in CM 1:4 mixed with water proofing compound on external surfaces of brick masonry wall finished even and fair complete all as specified and directed. (Note: Water proofing item to be paid separately)
Supply only Liquid water proofing compound complete all as specified and directed. (Make : Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for preparation of new plastered surfaces of wall and applying two coat oil bound distemper over a coat of alkali resistant primer complete all as specified and directed. (Make: M/s Tractor Acrylic Distemper of Asian/M/s Bison Acrylic Distemper of Berger, M/s No 1 Premium Acrylic Distemper of Shalimar).
M&L for preparation of new surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar)
M&L for moorum filling in floors or pavements, laid in layers n.exc. 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for broken stone hardcore of guage n.exc 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick Cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded coarse aggregate) in flooring complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-22 mm thick, laid over & including 20 mm thick (average thickness) cement mortar (1:4) screed and jointed with grey cement slurry mixed with matching shade pigment including rubbing and polishing complete all as specified and directed
M&L for kota stone slab 20-22 cm thick on vertical surfaces like riser of steps, skirting, dado and pillar laid over & including 10 mm thick (average thickness) cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed.
S&F 2nd class hard wood plain solid straight chowkhat and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint complete all as specified and directed.
S&F factory made 35 mm thick 2nd hardwood plain framed panelled shutters ( two panel) with lock rail and panel of 9mm thick B.W.P commercial ply. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35mm thick 2nd class hard wood, glazed & skeleton shutters, open rebated & prepared to receive glass, (two panel to receive wire gauge) gauge etc, edges of framing plain, chamfered as rounded fitted with cut and mitere beads for securing etc complete all as specified and directed.
M&L for preparation of newly wooden surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality with oil putty in square n.exc. 0.5m in each pane complete all as specified and directed.
S&F 100 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed
S&F for 125 mm aluminium handles, cast type, anodised complete all as specified and directed
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy complete all as specified and directed.
S&F door closer hydraulically regulated, aluminium body, designation No. 3 universal type, suitable for door shutters upto 851 to 1000 mm in width and of weight between 60 to 80 kg, ISI marked, complete all as specified and directed
M&L for framed work such as grills, grating, etc, with ends of bars shouldered and or riveted or forged into spike; framed guard bars for windows and iron gate conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F mild steel flat iron as in hold fast clamps small articles conforming to FE 290 GDE -E- 165 complete all as specified and directed.
M&L for PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in bed blocks for hold fast including necessary formwork complete all as specified and directed.
S&F rolled mild steel in plates channel (plain or chequered) square cut or notched (ordinary and counter shunk)forming holes, without any attachment of quality FE 410-W (Gde-E-250) quality-A complete all as specified and directed
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of quality FE 410-W (Gde-250) quality A complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on newly steel surfaces of any description over 10cm in width or girth not otherwise described including preparation of surfaces complete all as specified and directed
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, fixed with self tapping screws complete all as specified and directed
S&F wind ties for roof including securing bolts, flat iron fillets(for securing weather boarding with screw bolts and nuts) including all necessary drilling or riveting etc and similar work conforming to Fe 410-O or Fe-310-O including painted with one soap coat of zinc cromate primer paint (including preparation of surfaces at contractor's workshop before fabrication) complete all as specified and directed
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded coarse aggregate) in subbase and plinth protection complete all as specified and directed.
S&F floor door stopper of brass body 140 mm long and tongue with rubber shoes complete all as specified and directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers n.exc 25cm in soft loose soil complete all as specified and directed.
Removing excavated soil n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed
Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm in soft/loose soil complete all as specified and directed.
M&L for PCC type B2 1:2:4 (using 40mm graded stone aggregate), in foundations, filling and mass concrete complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles and removing rubbish from the premises complete all as specified and directed.
Taking down cement plaster, any description on brick or stone walls and ceiling, chajja, landing etc including racking of joints hacking for key scrubbing down with water etc and removing rubbish off from the premises complete all as specified and directed.
M&L for completely removal of existing surface and applying two coats of oil bound distemper on wall surface including applying alkali resistant primer complete all as specified and directed. (Make: M/s Tractor Acrylic Distemper of Asian/M/s Bison Acrylic Distemper of Berger, M/s No 1 Premium Acrylic Distemper of Shalimar)
Dismantling (corrugated, semi corrugated) sheet in roof covering complete all as specified and directed.
Taking down chowkhats or frame n.exc 1.5 Sqm each with shutter(s) (without taking off shutters from the frame), complete all as specified and directed
Taking down chowkhats or frame exceeding 1.5 Sqm but n.exc 4 Sqm each with shutter(s) (without taking off shutters from the frame), complete all as specified and directed
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge complete all as specified and directed
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge etc complete all as specified and directed
S&F 4mm thick sheet glass ordinary quality with oil putty in square n.exc. 0.5m in each pane complete all as specified and directed.
S&F 150 mm aluminium handles, cast type, anodised complete all as specified and directed
S&F factory made steel ventilator with side hung shutters, dovetailed or welded including pintol hinges, steel handles, etc. as shown with fixed type including one shop coat of red oxide zinc chrome primer, complete all as specified and directed.
Dismantling of wall or ceiling boards of any thickness including cover fillets complete all as specified and directed
S&F 605mm x 605mm Anodised aluminium snap grid frame work for false ceiling with all necessary aluminium angle & tee arrangement with and incl fixing cleats screws etc complete all as specified in SSR and directed.
S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm complete all as specified and directed.
S&F 6mm thick (non asbestos fiber) designer building boards fixed in aluminium frame work in ceilling flat or sloping with screw complete all as specified and directed
Demolition of cement concrete (un-reinforced) n.exc 15 cm thickness of any description and in any position and removing rubbish off from the site complete all as specified and directed
M&L for 50mm thick PCC 1:2:4 type B-1 (using 20mm graded coarse aggregate) in flooring with nominal reinforcement complete all as specified and directed.
M&L for coloured Non - skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete in floor, over cement screed bed 15mm thick in CM (1:6), including dismantling wall tiling and cement mortar bedding complete all as specified and directed
M&L for coloured Non - skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete in floor, over cement screed bed 10mm thick in CM (1:3), including dismantling wall tiling and cement mortar bedding complete all as specified and directed
M&L for glazed ceramic coloured tiles in vertical surfaces of size 350x250x7mm/350X450x7mm thick quality not less than group II, straight edge, as in skirting, dados, walls etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 10mm thick rendering in cement mortar (1:3), including dismantling wall tiling and cement mortar bedding complete all as specified and directed.
M&L for chequered cement concrete tiles 300x300x25mm thick, over & including 15 mm thick cement mortar (1:6) screed, set, jointed and pointed in neat cement slurry in floors complete all as specified and directed
M&L for cement concrete, 1:2:4, type B1 (using 20mm graded stone aggregate) as in bed block, coping ,lintel upto 1.50 m span, cills, kerbs etc complete all as specified and directed
Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint on old steel surfaces of any description over 10cm in width or girth not otherwise described incl preparation of surfaces and complete all as specified and directed
M&L for 200 mm thick with mix of fly ash, clinker & stone dust in the proportion of 1:3:6 (ie 10% fly ash, 30% clinker and 60% stone dust ) laying in layers n.exc 10cm thick, watering, ramming and compacted with vibratory/power roller 8 to 12 ton roller/hand roller where power roller can not be used to required camber and gradient complete all as directed by Engineer-in- Kankar or laterite, spread, rolled and consolidated to gradient and camber required complete all as specified and directed
M&L for 100mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed
M&L for 100 mm thick PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in hardstanding laid in panels with and including use and waste of formwork and to divide the area in panels and finishing the surface even and smooth with out using extra cement fair complete all as specified and directed
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ when thickness of concrete slab is 100mm complete all as specified and directed.
M&L for Excavating over areas, n.exc 1.5 m deep and getting out in soft loose soil complete all as specified and directed.
Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and directed.
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers or modular cover plate with frame of suitable size and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No 82.00 mentioned here-in-above but one 3 pin 5 Amps socket out let points on independent board complete all as specified and directed
All as per item No 82.00 mentioned here-in-above but 5 Amp socket on same board with other switches complete all as specified and directed.
M&L for wiring for socket out let on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including Modular pressed steel terminal switch boxes of different module and 4.0 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed
S&F switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed.
S&F switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified and directed
S&F socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and directed .( For Same Board only)
S&F switch socket combination 5 in 1 , 6 pin , (5/16 Amps ) flush type controlled by one switch complete all as specified and directed
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed
S&F stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified and directed
S&F lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified and directed
S&F two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including and including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. (Note: (i) 3 runs cable & PVC conduit pipe shall be measured and paid in single unit. (ii) Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
S&F security light fittings 25 watts, minimum lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbonate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed
S&F 18 W LED light fitting wall mounted batten 4'ft , extruded polycarbonate, environmental friendly, heat sink provided for efficient heat dissipation and integrated electronic driver for 18 watt,6000K including necessary connection complete all as specified and directed.
S&F recessed mounted 2' x 2 ' LED luminaire 36 watt complete all as described here-in-below:- (i) Total system lumen not less than 3960 lumens. (ii) High pressure die cast aluminium. (iii) IP rating :- IP 66 (iv) Front cover : Toughened Clear glass. (v) Mounting :- Suitable for recess mounting (vi) Finish :- Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp :- High bright LED with Lens. (viii) System efficacy (lm/W) of the luminaries :- Not less than 100 lm/watt. (ix) Colour temperature :- Not less than 5700K (x) Colour rendering Index (CRI) Not less than 74 (xi) Life : Not less than 50000 Hrs of operation (xii) Optics :- Spread (Beam angle along the driveway)- 120degree, Through( Beam angle across the drive wat)- 60 degree, Beam pattern - Asymmetrical driveway (xiii) Control gear:- Inbuilt electronic driver, PF not less than 0.90 and TDH less than 20% with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection :- Inbuilt surge protection minimum 5 KV (xv) Heat Sink :- As per OEMs design.
S&F Vertical distribution board double door TPN 4 way with IP 43 multiphase outgoing suitable for mounting 100 Amps as incomer with Bus bars, neutral links complete with all accessories complete all as specified and directed.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel, neutral link and incoming contact complete all as specified and directed.
S&F MCCB of 4 pole , 415 volts of capacity 100 Amps with breaking capacity of 16 KA Fixed thermal and fixed magnetic setting including necessary connection complete all as specified and directed.
S&F in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessary connection complete all as specified and directed.
S&F in repairs MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth wire electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion.
Taking down of AC ceiling fan of any sweep & any height and opening the fan and oiling, greasing and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and hanging it back in position including provn of 0.5 Sqmm copper flexible twin twisted cable (length n.exc 0.5 metre) from ceiling rose to fan as directed by the Engr-in-Charge. (Note : Accessories such as gun metal bush and split pin and jam nut shall be measured and paid under relavtem here-in-after).
M&L for painting of ceiling fans upto 1400mm sweep carefully, dismantling fan blades and paint with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc complete all as directed.
Supply, laying / fixing / connecting, testing and commissioning of 16 Sqmm x 4 core LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the cross sectional area including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and directed by the Engr-in-Charge. Note:- (i) Excavation, sand cushioning, brick will be measured and paid separately.
M&L for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . (Note : Punned thickness 18 cm shall only be considered for payment)
Supply and lay in trenches fly ash bricks, for cable protection complete all as specified and directed by the Engr-in-Charge.
S&F Pipes galvanized, 50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or complete all as specified and directed
Supply, laying / fixing / connecting, testing and commissioning of 10 Sqmm x 2 core LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the cross sectional area including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and directed by the Engr-in-Charge. Note:- (i) excavation, sand cushioning, brick will be measured and paid separately.
Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
S&F Surface mounted type decorative light fitting 1 x 10W LED 6k 230V AC, 50Hz complete with all accessories complete all as specified and directed.
S&F ceiling fan 1200mm size , star 5 rated, ISI mark, 240V, 50 Hz all as specified and directed.
S&F ventilating exhaust fan 300 mm sweep 230 volt AC complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size all as directed.
subash chander bahl
MS ROYAL CONSTRUCTION INDEX NO 158 2010 BKP
Jaibalaji Enterprise
Hooghly Construction Co.
NATIONAL CONSTRUCTION CO
UNITED BUILDERS
ROY ENTERPRISE
SUPARNA TRADING
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .