Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹78.8 LAccepted-Finance 263 URBAN ESTATE PHASE II BATHINDA | BATHINDA | PUNJAB | 151001 | ₹78.8 L | 1 | Accepted-Finance Ok |
| 2 | Not Admitted-Fee/PreQual/Technical 243 3 NEAR GOVT BOY SCHOOL BHAMNA PATTI SAMANA PATIALA | SAMANA | PATIALA | PUNJAB | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹82.2 L
EMD Value
₹1.6 L
Closing Date
2 Sept 2019, 5:00 pmClosed
Executive Engineer
Ranbir Club near red cross office Sangrur
Bid for Construction of Building for Water Sample Testing Lab for Water Supply and Sanitation Department at Reserve Stock Sangrur Distt. Sangrur
2019_WB_35977_1
WSSD/Sangrur/EE/2019-20/19
Open Tender
Civil Works - Buildings
Item Rate
180 days
Sangrur
Please refer Tender documents.
3 documents required · 3 mandatory
₹1
TIA
₹1.6 L
7 Feb 2020
5 Aug 2019
3 Sept 2019
5 Aug 2019
2 Sept 2019
5 Aug 2019
Amount
CivilnWork & Furniture
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. (6.6)
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres {6.8(a)i}
Cement Concrete 1:8:16 with 40mm gauge stone aggregate to be used instead of brick ballast. (10.10 b ii)
Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containing chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides up to height of 300mm by uniformly spraying solution @ 5 Litre / sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter (width - 300 mm, depth - 450 mm) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per sqm. (184.15 x 5 Ltr) (14.147)
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer using batch type concrete mixer as per IS: 1791 and vibrated by needle vibrator but excluded steel reinforcement centering and shuttering in foundation. (Plinth Beam) (10.16)
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) (9.1)
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3)
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. (10.21)
Column (Ground Floor)
Lintels/Sunshade (Ground Floor )
Beams (Ground Floor)
Slab (Ground Floor)
Shelves (Ground Floor)
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. (9.8)
Ground Floor Slabs & Shelve
Centring and shuttering for columns (Square or rectangular or poly gonal in plain) (9.4)
Column (Ground Floor)
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels (9.6)
Ground Floor Beam & Lintel
Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. (10.28)
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.. (11.4)
Ground Floor ( Main Walls)
115 mm thick brick wall laid in cement mortar 1 :4 without reinforcement in super structure. (11.34)
12.5mm thick cement plaster 1:4 (15.9)
Ground Floor (Main Walls) Partion Wall & Parapet Walls
20 mm thick cement plaster 1:4 in two coats work. (15.21)
Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement {13.13 (i)}
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (13.55)
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the premises laying in plinth in 15 cm layers including ramming, watering and consolidating including all leads. {6.8 (ci)}
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Ground Floor)(14.3)
Providing and laying vitrified floor tiles 600x600mm size premium quality, manufactured using Double Charge Technology, with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand) for new flooring laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per sqm of tile area in average 3mm thickness over existing base, including grouting he joints (Tiles to be laid with 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout).with cement based grout and matching pigments etc., complete (Design is homogenous throughout the tile body). (14.132)
Black granite stone tiles 20mm thick in skirting, risers of steps dado, walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement, 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowels pins and cramps. (14.91)
Providing and fixing stair case railing made out of M.S. square bars 20mm x 20mm as vertical part 0.57.5 m high fixed with M.S. base plate of 40mm x 40mm x 6mm and flat iron 40mm x 6mm as hand rail complete in all respect. (18.30)
Providing and Fixing of 65mm wide PVC cover on stair case railling 1st quality in any shape and size fixed with adhesive compound complete in all respect as per drawing and entire satisfactio of engineer- in -charge. (N.S)
Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc.complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge. (17.62)
Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. (Vertical & Horizontal) (17.64)
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm {17.23 (ii)}
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm {17.49 (a)}
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. (18.4)
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm thick above 0.40 sqm area. 18.25 (b)
Supplying and fixing of Pressed steel sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiveing tower bolts and finished with 2 coats of ready mixed painted lead non setting primer of approved quality, fixed in position including the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete (17.45)
Door and window frame of size 113mmx60mmx with 35mm wide Doublerebate
Providing and fixing MS Tubular frames for doors, windows, ventilators and cupboard with L-Type section made of 1.60mm thick MS Sheet, Joints mitred and welded and grinded finish, with profiles of required size with 15x3mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 or with wooden pugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primers. (@ 25 Kg/Sqm) (16.14)
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 (17.27 b)
35 mm thick (iv)
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 550 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete (18.18)
Preparation of plastered or concrete surface for painting including sand papering the surface using readymixed cement based wall putty by applying two coats to get reqiered finish complete. (16.66)
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade. (16.11)
Finishing Wall with exterior decorative cement based paint such as snowcem, robbiacem etc. two coats to give an even shades (16.14)
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fills consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Applying pink primer or aluminium priming coat on wood work including preparation of surface knotting and stopping etc. B) With ordinary quality Paint
Painting two coats excluding priming coat with readymixed paint for metallic surfaces in all shades on new steel or iron work. B) With ordinary quality Paint
Office Table (6x3)
Office Chair (Executive)
Office Chair (Visitor)
Computer Chair
Reception Table (4x2)
Reception Table (6x2.5)
Steel Almirah
Steel Rack
Work Station set
ELECTRICALS
Wiring in PVC insulated copper conductor single core FR cable (ISI marked), 1100volts grade to be laid in heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules, for having electronic fan regulators (two module), bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20 Amp. Sockets and 6 Amp./16/20Amp. Swithces etc., and covered with Frame Plate etc., & including the cost of required number of modular switches/sockets, step type electronic fan regulator 100 watts, PVC connector (For Fan Box and Electronic Buzzer), PVC Bush, SteelHooks,CircularInspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:- (33.01)
Wiring fan point with sheet metal fan box (shape hexagonal ) in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with steptype electronic fan regulator 100watts (two module). (i )(b)
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade. (ii)
Wiring call-bell point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with bell push and electronic buzzer 230 volts AC (including the cost of bell push, electronic buzzer & powder coated concealed metal box for electronic buzzer). (iii)
Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade. (iv)
Wiring 3 Pin 6 Amp. Plug control comprising wall socket (shuttered) and switch including bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade complete. (v)
Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch. (vi)
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with double control switches. (viii)
Wiring TV sockets and Telephone socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules, for having TV sockets, Telephone sockets RJ11 & RJ45 (one module) etc., and covered with Frame Plate etc., & including the cost of required number of modular TV sockets, Telephone sockets RJ11 & RJ45 (one module) and other petty material etc. including the cost of cutting and filling up of chases:- (ix)
Wiring Telephone socket point RJ11 (one module) (b)
PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE: (33.09)
Supply and erection of PVC insulated single core FRLS copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and erection of pipe or casing.
PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq.mm, 1100volts grade (ii)
PVC insulated copper conductor single core FRLS cable (ISI marked) overall 2.5 sq.mm, 1100volts grade (iii)
PVC insulated copper conductor single core FRLS cable (ISI marked) overall 4 sq.mm, 1100volts grade (iv)
PVC insulated copper conductor single core FRLS cable (ISI marked) overall 10 sq.mm, 1100volts grade (vi)
PVC insulated copper conductor single core FRLS cable (ISI marked) overall 16 sq.mm, 1100volts grade (vii)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: (33.12)
Supply & erection of PVC pipes & HDPE pipes (fire retardant) for wiring purposes including bends, inspection boxes etc.,where necessary including other petty material as per PWD General Specifications 2010:-
Heavy gauge PVC conduit pipe 20mm dia. (ISI marked 2mm thick) Flushed (vi)
Heavy gauge PVC conduit pipe 40mm dia. (ISI marked 2mm thick) Flushed (ix)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: (33.16)
Supply and erection of Miniature Circuit Breakers/ RCBO's/RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.
GROUP-A: (Siemens (Beta Guard), Legrand (Lexic) & Schneider (Neo Break), L&T (Hager)
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply (ii)
Miniature circuit breaker double pole 50, 63amp. (Breaking capacity 10kA, Curve-C)suitable for 240/ 415 volts 50cycles AC supply (viii)
Miniature circuit breaker four pole 50, 63amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply (xvi)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: (33.17)
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.
GROUP-A: (Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager vision+)
Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/ TPN MCB's/ isolators for incoming and DP/ SP & N/ Single Pole MCB's /RCBO/RCCB's for outgoing 8 way each (vii)
Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/ TPN MCB's/ isolators for incoming and DP/ SP & N/ Single Pole MCB's/ RCBO/RCCB's for outgoing 6 way each (vi)
GROUP-B (Havell's HPL, ABB, Standard & other brands approved by PWD)
Sheet metal plug and socket distribution board single pole MCB and neutral enclosure with a two pin and earth plug socket to incorporate in one single pole MCB 20amp. (xxiv)
XLPE/ PVC INSULATED ARMOURED CABLES (LOOSE): (33.10B)
Supply & laying of aluminium conductor XLPE/ P.V.C. insulated armoured and served cable to be laid loose in the existing trench or pipe as per PWD General Specidications 2010:-
xxviii) Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 150sq.mm (3 ½ Core) for power & emergency load
COPPER EARTHING: (33.14)
Earthing of Sheet metal/ iron clad switches and metallic cases etc., with 20 mm x 3 mm thick electrolytic copper tape rivetted (with 10 nos. copper rivets) to 30 cm x 120 cm x 3 mm thick tinned copper plate (made cylindrical) burried 20 metre below ground level in the hole of excavation having bore dia. 125mm and surrounded bysalt & charcoal dust mixture (20 kg.) including fixing the copper tape on wall and in floor etc., up to 23 metre inlength (including bore length). G.I. pipe 20mm dia. (Aclass) should be laid in the hole of excavation from bore urface level to 1 feet below ground level and having wire mesh funnel fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation. (ii)
Supply and Erection of 20mm x 3mm thick copper tape (As additional length). (xiii)
GALVANIZED IRON PIPES AND G.I. EARTHING: (33.13)
Supply & erection of G.I Pipe for wiring purposes including bends, inspection boxes etc. where necessary including painting as per PWD Genenral Specification 2010.
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/12 S.W.G. (7/2.80mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling). (c)
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: (33.37)
Supply and erection of double walled corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation (making necessary trench), placing the pipe in position and back filling with excavated soil etc. of the required size.
Double walled corrugated (DWC) HDPE pipe 120/103.5mm (outer/ inner dia.) (iv)
Supply and erection of Surface mounted Box type 1 x 28watt T-5 lamp channel luminaires Make Crompton Greaves Cat. No. T5GP 28EB Phillps TMS 122M 1x TL528W EBT suitable for 1x 28watt energy saving tube complete with box type fixtures including lamp. electronic choke (Low losses & improved power factor) and lamp holder etc. along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charges at site. (NSR)
Supply and erection of Surface mounted Box type 2 x 28watt T-5 lamp channel luminaires Make Crompton Greaves Cat. No. T5GP 28EB and Phillps TMS 122M 2xTL528W EBT suitable for 2x 28watt energy saving tube almp complete with box fixtures including lamp, electronic choke(Low losses & improved power factor) and lamp holder etc. along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charges at site. (NSR)
S/E of Energy Saving Ceiling Fans 1400mm sweep ( 56") Make Crompton/Havell's/Orient ISI Marked having two ball bearing but without regulator including flexible wire & petty material etc. for connection complete wih erection, connections and testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. (NSR)
S/E of Energy Saving Ceiling Fans 1200mm sweep ( 48") Make Crompton/Havell's/Orient ISI Marked having two ball bearing but without regulator including flexible wire & petty material etc. for connection complete wih erection, connections and testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. (NSR)
Supply and erection of 18" Exhaust fan (450mm) sweep of make Crompton/Havell's ISI marked heavy duty motor with die cast Aluminium rotor mounted on two ball bearing including erection, connections and testing etc. complete with flexible wire and petty material reqd. for connectoins and Aluminium louver shutter complete in all respects as appd. and desired by the Engineer-in-charge at site. (NSR)
Supply and erection of 12" Exhaust fan sweep of make Crompton/Havell's ISI marked heavy duty motor with die cast Aluminium rotor mounted on two ball bearing including erection, connections and testing etc. complete with flexible wire and petty material reqd. for connectoins and Aluminium louver shutter complete in all respects as appd. and desired by the Engineer-in-charge at site. (NSR)
Supply and erection of 20mm dia, heavy gauge welded conduit pipe (1.60mm thick) suspension rod for celling fan complete in all respcet as desired by the Engineer-in-charge. {33.11 (xi)}
Supply and erection of Fancy type wall bracket of brass material with double lamps and covered with coloured fancy glass ISI marked of approved Make and shape including CFL lamp spiral 15W and erection, connection, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. (NSR)
Supply and Erection of Connealed Metal box 3"x3" (1&2 Module) Recessed in wall including the cost of cutting & filling of chases with complete connections as per satisfaction of the Engineer-in-charge Make: LEGRAND (NSR)
Supply Erection, Testing & Commissioning of Indoor Cubical Panel shall be suitable for operation at 415 + 6% volt, 50Hz, 3 Phase wire + E system Panel will be free standing, floor provision for cable entry from bottom or top as per requirement, The panel will be extensible type in design with dust and vermin proof. The switchgear frame shall be fabricated using mild steel structrual section pressed as shaped cold rolled steel smoothly finished levelled and free from flaws of thichness not less than 16SWF. The complete structure shall be rigid, self supporting and free from twist & bends Entire sheet metal work will undergo pre- treatment covering degreasing, sensing, derusting/phosphating using various tanks installed in paint shop. The sheet metal is sprayed with corrosion resistant Etch primer. The Finishing treatment shall be applicable with synthetic enamel/air (Powder coated)after necessary putty work. Panels will be provided with doors having all along the length of panel. Each Outgoing switch is feeded from the main busbar with copper strips of suitable (NSR)
size according to the capactiy of each switch. Bus Bars shall be of uniform cross-section through out the Length of the switchgear, Bus Bars shall be of high conductivity COPPER (Current density will be equal to or not less than 1.39Amps. per sq mm) All Bus Bare will be codified in Red, yellow Blue and Black Colour as per standred prectices. Panel will be provided with lables on the front indicating the switchgear designation and shall be made of anodized aluminium property fixed using screws of appropriate size, Earth Bus bars shall be supported at suitable intervals. A base frame of iron channel 75mm x 40mm x56mm is to be welded at the bottom of the panel. The Panel shall be complete in all respects as approved and desired by the Engineer-in-charge of the work. The size & design of Panel will be as per site available:-
Incorner: MCCB 250 Amp. 4 Pole 16 KA = 1 no
Supply and erection of Flood light luminaire of Make Halogen lamps phillp, cronpton 500W. The fitting will be mounting with the help of 'U' shape MS channel 3"x 1 1/2", the fittling and gear box frame will be fixed with 8" nuts &bolts across including painting the MS Channel and complete as per satisfaction and desired by the Engineer-in- Charge at site. (NSR)
OVER HEAD DISTRIBUTION ALUMINIUM CABLES & ACSR CONDUCTORS: (33.34)
Wiring over-head line in two single core cable with aluminium conductor insulated with P.V.C. and P.V.C.sheathed overall 1100 volts grade on G.I. wire 4mm dia. with brass/ aluminium link clips cable. (i)
PVC insulated & PVC sheathed two single core aluminium conductor cable overall 1100 volts grade size 10mm² (1/1.40mm) ©
Generator Set
Providing, installing testing and commissioning of generator set 20 KVA on CC foundation including making connection with panel board change over switch etc. complete. (Kirloslar, Sudhir) (NS)
GALVANIZED IRON PIPES AND G.I. EARTHING: {(33.13) (vii) (c)}
Supply & erection of G.I. pipe for wiring purposes including Bends, inspection boxes etc., where necessary including Painting as per PWD General Specifications 2010:-
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/12 S.W.G. (7/2.80mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).
Providing and fixing Truss Type Shed made upto MS frame covered with fibre sheet for protection of Gen. Set against SUN & RAIN of area 100 sft. (NS)
PUBLIC HEALTH SERVICES
SUB HEAD NO . 1
Estate Water supply, Sewerage & Development of site
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage. D.I. Pipe as per IS 8329 DI-K7 (28.07 A)
80mm i/d pipe lines laid complete (a)
Supplying and laying D.I. specials/fitting as per IS:2000 (ISI marked with the prior approval of Engineer Incharge) class k-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys etc complete in all respects. (28.25
C.I. specials upto 300mm i/d (a)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1 as per ISI 28.27 (A)
80mm i/d Sluice Valves flanged (b)
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. (28.66)
Size 0.6 m. x 0.6 m. (a)
Providing & fixing C.I indicating plates of size 100mm x 100mm for SV/FH including synthetic enammel paint & letters in white enamel paint , fixing in the ground with angle iron of size 25x25x5mm, 230mm height from ground including concrete block complete in all respect as directed by Enginner-in-Charge. (28.33)
Providing, fixing and jointing Cast Iron surface box for Sluice valve, Air valve, Fire hydrant etc. including all carriages complete. (Weight @6kg per box) (28.32)
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. (29.5)
For depths not exceeding 3.0 metre B.G.L. (A) For all classes of soil except rocky (a)
For Sewer Line 160 mm & 100mm dia
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. (29.65)
160 mm o/d pipes (c)
110mm o/d pipes (a)
Sand filling under and around UPVC pipes (For sewer line 160mm i/d (15x0.19) & 100mm i/d (10x0.19) (NS)
Extra for making connections of all sizes newly laid sewers within benching of fully charged sewers including pluging of sewer, dewatering & desilting of manholes etc. complete in all respects. (With existing sewerage ) (29.103)
Providing and laying 60mm thick cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro-hydraulic compaction machine and of approved size and design/ shape laid in ordinary grey colour and pattern over and including 40mm thick compacted bed of coarse sand,filling the joints with fine sand etc,all complete as per directions of engineer-in-charge for light traffic areas such as pedestrain plazas,shoping complexes,ramps,car park,office driveways,housing colonies,office complexes,rural roads with low volume traffic,farm houses,beach sites,tourist resorts,local authority footways,residential roads,etc. (14.155)
Earth filling under floors with surplus ordinary soil or soil containing gravel on kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidated lead upto 30 metres
Construction of brick masonry toe wall in 15 cement sand mortar with depth 0.90 mtr C.C 1816 AND 12.5MM thick cement plaster in 14 on both sides and top of toe wall complete in all respects
Providing & Fixing Udyogi Safety Shower & eye wash (6250 G.I) Including Cost of HDPE water storage tank triple layer 1000 ltr., G.I tank nipple, 40.00mm G.I pipes (as per IS 1239) B-Class , Construction of platform for HDP Tank & Labour Complete in all respect.
SUB HEAD NO .2
Internal Water supply , Sewerage & installation
Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make such as (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. (28.35)
15mm i/d (a)
20mm i/d (b)
40mm i/d (d)
Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. (28.40)
15mm i/d G.I. Union (a)
20mm i/d G.I. Union (b)
25mm i/d G.I. Union (c)
40mm i/d (d)
Painting G.I. Pipes and Specials with synthetic enamel Paint in all shades as per I.S.I. specification on existing or new work, two coats paints including cleaning rubbing surface, etc. (28.52)
15mm & 20mm i/d G.I. Pipe (a)
25mm & 40mm i/d G.I. Pipe (b)
Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-charge )including cutting, jointing, wastage, but including cost of jointing complete in all respect. 30.74 (iii)
110mm o/d SWR UPVC pipe line laid complete (b)
75mm o/d SWR UPVC pipe line laid complete (c)
Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonage pipes as per as per IS - 14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. 30.81(iii)
For 110mm i/d pipes (a)
Bend Plain (v)
Cowls (vi)
Collars (vii)
For 75mm i/d pipes (b)
Bend Plain (vi)
Cowls (vi)
Collars (vii)
With 75mm i/d outlet deep seal at Ground Floor (viii)
Construction of brick masonry inspection chambers size as given below upto 0.60 m average depth in 1:5 cement sand mortar, lime concrete with 40 per cent lime mortar 2:3 in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside light duty C.I. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. (29.89)
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal (b)
Extra for every 0.30 metre depth of inspection chamber. (29.90)
450mm x 600mm inside (b)
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer in charge ) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer in charge. (30.4)
Providing and fixing jet spray with 2'-6" long PVC pipe.With PTMT nut {30.8 (b)}
Providing and fixing partition for different type of urinals. 15 to 20 mm thick Dungri marble partition size 375mm x 750mm {30.21 (A) (i)}
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap complete in all respect. (30.37)
Size 630mm x 500mm (above counter oval) (viii)
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. (30.47)
Size 600 mm x 450 mm x 225 mm (Net size excluding flat edge) (a)
Providing and fixing in position vitreous Chinaware sinks of approved make (to the approval of Engineer-in-charge) consisting of 40mm i/d C.P. brass waste, pair of brackets complete in all respect. (30.46)
Size 610 mm x 450 mm x 250 mm (b)
Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect. (30.57)
C.P. brass toilet paper holder (a)
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. (30.58)
C.P. brass towel Rails size 15mm dia 600mm long (a)
C.P brass towel ring (b)
C.P. brass towel bracket (610mm long) (c)
Proving and fixing of looking glass mirror 0.5 mm thick including cost of wooden frame complete in all respects (Make: Atul /Modiguard) on any other Equivalent. (NS)
1.59 x 1.00 mtr = 1.59 sqm (a)
Providing and fixing in position vitreous Chinaware white senso urinal of approved make (to the approval of Engineer-in-charge) complete in all respect. (30.17A)
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. (30.60)
Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect. (30.67)
C.P. brass liquid soap container (a)
Providing & fixing in position C.P. copper tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. (30.73)
C.P. copper tube connection of size 15 mm x 600 mm with C.P. Brass nut (d)
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. (30.65A)
C.P. brass Bib cock long nose/ long body without flange (i)
C.P. brass Bib cock without flange (ii)
Providing & Fixing in postion stop cock / Angle valve (as approved by the Engineer-in-charge). (30.66)
C.P.brass 15mm Concealed stop cock with flange. (b)
C.P.brass 15mm Angle valve ©
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. (30.99)
100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm (a)
Providing & Fixing in position C.P. Brass flange of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. (30.64 A)
Providing & Fixing in position C.P. Brass extension piece 25mm long to 50mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. (30.64 B)
Providing & fixing in position best Indian make PVC flexible tube connection. PVC tube connection of size 15 mm x 375 mm with PTMT nut (30.72 e)
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks {30.97 A) (ii)
2000 ltr Capacity & 1000 ltr Capacity = 3000 ltr Capacity (a)
Providing and fixing in postion storage type automatic electric water heater pressure / non pressure type thermostatically controlled, single phase, vertical wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. (30.102)
25 litre capacity water heater (a)
50 litre capacity water heater (c)
Providing and fixing in position automatic brass Ball Cock in tanks. (30.96 B)
Brass Ball Cock with rod and Plastic Ball 32mm i/d (iii)
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm (30.85 a)
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. (28.56)
Through wall 22.86 cm thick (b)
Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. (28.44)
20mm i/d Brass Ball valves (b)
25mm i/d Brass Ball valves (c)
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. (30.78)
M.S. Holder bats clamps for 110mm i/d PVC SWR. Pipes (a)
M.S. Holder bats clamps for 75mm i/d PVC SWR. Pipes (b)
Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. (28.11)
uPVC Pipe 6 Kgf/cm2 (50mm i/d ) (B) b
Providing and fixing PVC waste pipe 32mm complete in all respect. (30.20)
Qty same as WB+Urinal+Steel sink+ Drinking water except Geyser
Providing & fixing 15 mm C.P brass laboratory cock swan neck of approved make (to the approval of Engineer-in-charge ) complete in all respect. (30.68)
Laboratory cock swan neck One Way (a)
Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs and C.P brass screws complete in all respect. CP brass Acrylic Shelf size 560mmx130mm (30.59) (a)
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (30.61) (a)
Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect. (30.100)
Construction of Plateform complete as per specification & as desired by Enginer-in-charge( For urinal) (NS)
Flooring and Wall Tile
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) including carrage (14.3)
Anti-skid floor tiles 10mm thick in flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with white cement slurry in joints including corners angles and beading. (14.71)
Door Cill
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 300 x 300mm mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (14.142)
Water Cooler
Supply & installation of self contained drinking water cooler with (Non CFC Refrigerant) energy efficient compressor of make USHA, Model No. SRA 60 120 G, cooling capacity Ltrs/hr. 60, storage type capacity 120 Ltrs. Including installation etc. Complete in all respect as approved and desired by the Engineer-in-charge at site. Make...USHA/ Voltas. complete in all respect. (NS)
Supply & installation of AQUA FLO DX UV Water purification system, capacity 60 ltr. Per hour, 100% chemical free, Dimension 210mm width x 140mm depth x 382mm height, in built voltage stabilizer, Hi Flo, Dual Cartridge including installation etc. Complete in all respect as approved and desired by the Engineer-in-charge at site. Make... EUREKA FORBES/ Kent .complete in all respect. (NS)
SUB HEAD NO . 3
FIRE FIGHTING ARRANAGEMENTS
Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity (28.125 c)
Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity (28.124 c)
Supply and erection of 4 nos. buckets having capacity of 10 Kg. of appd. Quality alongwith M.S. Pedestal stand , Red painted confirming to IS : 2546/1974 duly ammended up to date including the cost of stand, filling etc. as required complete in all respect as approved and desired by the Engineer-in-Charge. (NS)
Providing & fixing smoke detectot ISI Marked as required complete in all respect as approved and desired by the Engineer-in-Charge. Total covered area = 102' x 78' =7956 sft Area covered by 1 smoke detector=100 sft No. of smoke detector = 7956/100 = 80 Nos (NS)
Providing & fixing Fire Panel 16 zone with battery ISI Marked as required complete in all respect as approved and desired by the Engineer-in-Charge. (NS)
Providing & fixing Hotter ISI Marked as required complete in all respect as approved and desired by the Engineer-in-Charge. (NS)
Providing & Fixing Mcp complete in all respect. (NS)
Installation charges for Hoter complete in all respect (NS)
Providing & Fixing Wire roll 1.50mm complete in all respect. (NS)
SUB HEAD NO . 4
AIR CONDITIONERS
Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 3 Star Make:- Carrier, Hitachi, Voltas, Blue Star, Daikin with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects (NS)
2 ton capacity (6000 K. Cal/hr) 3 star model (a)
1.5 ton capacity (4500 K. Cal/hr) (b)
Providing laying hard soft copper concealing of copper pipes of various dia as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects.10 mtr. per unit
Providing and fixing PVC 70/76 3 core wire including cutting chase in wall & making good the walls complete in all respect as per approval of Engineer-in-charge (NS)
Providing and fixing 15 mm PVC drain pipe with specials including cutting the chase & making good the walls complete in all respect as per approval of Engineer-in Charge. (NS)
Provision for Land Scaping
Planting permanent hedge including digging of trenches 60 cm wide and 30cm deep refilling the excavated earth mixed with manure supplied @ of 4.65 cum per 100 m & supplying & planting hedge plants at 30 cm apart. (NS)
Supplying and planting permanent trees including digging of pits size 75cm x 75cm x 75cm deep, refilling the excavated earth. With with manure supplied @ 0.113 4 cum each like Neem ,Ashoka ,Dake Arjun Etc. (NS)
Making lawns including ploughing & dragging with 'Sohaga' breaking of clods, removal of earth rubbish dressing & Supplying doob grass roots and planting at 15 cm. apart supplying and spreading of farm yard manure & loosening (NS)
Planting ground cover plants including digging and refilling of beds with excavated soil and FYM, Fertilizer and insecticides, planting of saplings at 30cm distance from plant to plant and row to row, providing and fixing brick tiles edging. (NS)
Planting flower beds including digging and refilling of beds with excavated soil and FYM, fertilizer and insecticides, planting of sapling at 30cm distance from plant to plant and row to row. Around pump chamber OHSR and both side of path. (NS)
Provision for One way stand post with Khurra complete in all respects. (NS)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .