Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC 1 28 NORTH STREET SOUTH VILAYANARAYANAM NANGUNERI TALUK TIRUNELVELI DIST 627 118 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627118 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹10.5 L+₹45,958 (4.58%)Rejected-AOC 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L2 | Rejected-AOC Rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical Since not enlisted in appropriate category | |
| 4 | Rejected-Technical | - | Rejected-Technical Since not enlisted in appropriate category | |
| 5 | Rejected-Technical 10 67 1 CHINNAMUSHIDIWADA PENDURTHI VISAKHAPATNAM ANDHRA PRADESH 530051 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530051 | - | Rejected-Technical Since not enlisted in appropriate category |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
17 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
Garrison Engineer Naval Post Base Vijayanarayanam Tirunelveli -627119
REPAIR/MAINT OF SUMMER COOLING APPLIANCES AT KATTABOMMAN AND RS(P) UNDER GE TIRUNELVELI
2024_MES_647179_1
GE/TVL/8356/E8 of 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Vijayanarayanam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹19,000
Yes
8 Jul 2024
20 Mar 2024
19 Apr 2024
20 Mar 2024
17 Apr 2024
3 Apr 2024
21 Mar 2024 - 30 Mar 2024
Amount
Checking of Split/ Window AC at INS Kattabomman, RS(P), of capacity 1.5/ 2.0 TR any type for smooth functioning as per manufacturer specification complete all as specified and directed and including replacement of minor components as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:- (i) Cleaning of coil unit with dust blower, lubricate the indoor & outdoor fan motor with oil. (ii) Checking and cleaning the drain connection and air filter periodically, washing of coil with solution once in a contract period. (iii)Checking the refrigerant pipe insulation. (iv) Check & repair the minor electrical fault in incoming supply. (v) Checking and cleaning drain pipe for water leakage from indoor unit. (vi) Supply of spares/components required to be replaced under this contract shall be measure and paid separately. (vii) Checking the fault of cooling/ heating appliances.
Supply only the following for 1.5/2.0 Ton capacity window/split type AC including testing and commissioning etc complete all as directed by Engineer-in-Charge.
(a). Starting Capacitor 80/100 MFD.
(b). Running Capacitor but 36 MFD.
(c). Relay Assembly (Make: SRI RAM).
(d). Over load protector (O L P) (Make: SRI RAM).
(e). Thermostat (Make: RANUTROL/INDOFOSS).
(f). Air filters (FIL/ UTILITY/ SPENCER/ VOLTAS/ AIRCON/ VIDEOCON / SIDWAL).
(g). Condenser fan blade metal or plastic.
(h). Blower with circular leaf.
(j). Fan capacitor (Make: SARADA/USHA/UNISTAR/KELTRON), 4/6 MFD.
(k). Cabinet wiring Kit .
(m). PVC insulated, sheathed 3-core, 2.5Sqmm copper cable
(n). Strainer tube (copper)
(p). Non Return valve (For gas top up charging)
(q). Capillary tube (copper)
(r). Condenser coil unit (For A/C)
(s). PCB board suitable for indoor unit of Split AC 1.5/2.0 TR any type (Inverter/ normal type)
Supply and fixing the following for water cooler :-
(a). Relay unit for water cooler.
(b). PVC float Ball valve, high pressure with polythene float and fly nut screwed to iron pipe or ferrule of bore 15mm for water cooler
(c). Thermostat switch for water cooler. (Make: RANUTROL/INDOFOSS).
(d). Water tap push type suitable for water cooler
Supply and fixing the following for refrigerators :-
(a). Relay unit for refrigerators.
(b). Thermostat assembly for refrigerator.
Taking down, checking for serviceability and supply and fix new compressor including first filled Oil, cleaning the refrigeration system/pipe before installing with CO2 and charging refrigerant gas as required, providing/refixing if required NRV for further gas top up and re-fixing in the position including testing complete all as specified and directed.
(a). Window/ Split type AC 1.5 Ton capacity (Make: SRIRAM/ KIRLOSKER/ TECUMSHAW/ VOLTAS).
(b). Window/ Split type AC 2.0 Ton capacity (Make: SRIRAM/ KIRLOSKER/ TECUMSHAW/ VOLTAS).
(c). Water cooler 40/80 Litres capacity (Make: SRIRAM/ KIRLOSKER/ Voltas).
(d). Refrigerators any capacity
Supply and fixing Fan motor suitable for condenser unit of window/split AC complete with all accessories and fixing in position and testing the unit as directed by Engr-in-charge.
Taking down existing worn out fan from Split AC 1.5/2.0 TR AC and supply and fix motor of same capacity (single speed) with standard manufacturer specification including testing and commissioning complete all as directed by Engineer-in-Charge. (Make: LG/BLUE STAR/ VIDEOCON/ VOLTAS).
All as per item No.7 but for Water cooler. (Make: SRIRAM/ KIRLOSKER/ Voltas).
Taking out refrigerants of ACs 1.5/2.0 Ton capacity, Refrigerators and water cooler, cleaning the refrigeration system with CO2 and charging refrigerant gas M-22/F-22/R-134/R-410 or equivalent as per manufacturer recommendation and reassembling the system in original position complete including testing and commissioning for the following all as directed by Engineer-in-Charge.
(a). Split/window type AC 1.5/2.0 Ton capacity
(b). Refrigerator 180 to 300 Litres capacity.
(c). Water cooler 40/80 & 60/120 Litres capacity .
Material and labour for SPN enclosure with two pin and earth plug with socket 240 volts 20 Amp MCB including replacement of old unsv one complete all as specified .
Supply only copper pipe of split AC 1.5/2.0 ton capacity complete all as specified and directed by Engr-in-charge.
Taking down refrigerant of Split AC of any capacity by dismantling, checking for leakages at various places and fixing the indoor and outdoor units and making electric and copper pipe connection complete all as specified and directed by Engr-in-charge. (Note : - Spare parts replaced shall be measured and paid separately under relevant items.)
Supply and fix PVC flexible drain pipe suitable for 1.5/2.0 TR split / window type AC complete all as specified and directed.
Material and labour for Opening and dismantling both sides covers of Condensor and descaling of Condensor unit 16.5 TR by pumping chemicals, brushing with rods, cleaning/ oiling of tubes, replacement of gasket and reassembling it after descaling complete all as directed.
Checking of Package type AC of capacity 16 TR at Tarangini Auditorium for smooth functioning as per manufacturer specification including replacement of faulty components as required OLP, PCB card, Relays, Sensors complete all as specified and directed by Engr-in-Charge.
Supply and charging gas refrigerant R 22 in the Central AC plant of capaity 16.5 TR all as specified and directed. Make : Mafron/freon
M/s.Sai Agency
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .