Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.7 LAccepted-AOC AT BACHRA P O BACHRA P S PIPARWAR BACHRA 829201 | BACHRA | CHATRA | JHARKHAND | 829201 | L-1 | Accepted-AOC As per recommendation of TC and approval of competent authority | |
| 2 | L-2₹1.8 L+₹5,899.36 (3.38%)Rejected-Finance | L-2 | Rejected-Finance As per recommendation of TC and approval of competent authority | |
| 3 | L-3₹2.3 L+₹53,101.68 (30.4%)Rejected-Finance AT MOHAN NAGAR PO DAKRA PS KHALARI DISTT RANCHI JHARKHAND 829201 | CHATRA | JHARKHAND | 829201 | L-3 | Rejected-Finance As per recommendation of TC and approval of competent authority |
Tender Value
₹2.2 L
EMD Value
₹2,790
Closing Date
30 Mar 2024, 5:00 pmClosed
Staff Officer (EnM),M-S Area
Office of the General Manager M-S Area
Repairing and Rewiring of Quarter, MQ- 03 Vishnujhappa Colony Bachra and Qtr. No. TH- 07, 1 BR Colony Bachra and VIP room with AC service wire and extra point in Arunoday Bachra under Magadh - Sanghmitra Area
2024_CCL_305607_1
GM(MS)/SO(EnM)/e-NIT/23-24/160
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Office of the general manager M-S Area, Bachra
Please Refer NIT
4 documents required · 4 mandatory
₹2,790
11 Aug 2024
19 Mar 2024
1 Apr 2024
20 Mar 2024
30 Mar 2024
20 Mar 2024
20 Mar 2024 - 27 Mar 2024
Amount
Qtr. No. MQ-03,Vishnujhapa Colony:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc.as required.
Wring for circuit/ subman wiring alongwith earth wire with 2x2.5 sqmm + 1x2.5 sqmm. FR PVC insulated copper conductor single core cable in surface/recessed steel conduit as required
Supplying and fixing of metal box of 180mmX100mmX60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 15/16 amps socket outlet and 15/16 amps piano type switch connection , painting etc. as required.
Wiring for light/power plug with 2x4sqmm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1No. 4 sqmmFR PVC insulated copper conductor single core for loop earthing as required.
Supplying and fixing of 5amps to 32amps rating, 240/415volts "c" curve, miniature breaker suitable for induction load of following poles in the existing MCB DB complete with connections testing and commissioning etc.as required. (1) single pole.
Supply of 2+2 way, SPN single door, MCB distribution box.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 150 mm X 60 mm
Supplying and fixing two modular stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Qtr. No. TH -07 1 BR Colony:- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.
Supplying and fixing of metal box of 180mmX100mmX60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 15/16 amps socket outlet and 15/16 amps piano type switch connection , painting etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. COST FOR 1 POINT
Supplying and fixing of 5amps to 32amps rating, 240/415volts "c" curve, miniature breaker suitable for induction load of following poles in the existing MCB DB complete with connections testing and commissioning etc.as required. (1) single pole.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply of 2+2 way, SPN single door, MCB distribution box.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 150 mm X 60 mm
Supplying and fixing two modular stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required Group A
Repairing of VIP Rooms with AC Serivce :- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required Group A.
Supplying and fixing of metal box of 180mmX100mmX60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 15/16 amps socket outlet and 15/16 amps piano type switch connection , painting etc. as required.
Wring for circuit/ subman wiring alongwith earth wire with 2x2.5 sqmm + 1x2.5 sqmm. FR PVC insulated copper conductor single core cable in surface/recessed steel conduit as required
Supplying and fixing of 5amps to 32amps rating, 240/415volts "c" curve, miniature breaker suitable for induction load of following poles in the existing MCB DB complete with connections testing and commissioning etc.as required. (1) single pole.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply of 2+2 way, SPN single door, MCB distribution box.
SSupplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 150 mm X 60 mm
Supplying and drawing of 2x6sq.mm of FR PVC insulated copper conductor single core in the existing surface recessed steel/PVC conduit as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Total impact of GST for the purpose of CTC
Baldeep Construction
M/S MAA CONSTRUCTION
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_316658.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .