Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.4 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST TENDER | |
| 2 | L2₹91.9 L+₹7.5 L (8.91%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L2 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 3 | L3₹92.6 L+₹8.3 L (9.79%)Rejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L3 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 4 | L4₹93.3 L+₹8.9 L (10.5%)Rejected-Finance DOOR NO 6 1 JOTHI NAGAR 6TH STREET VARATHARAJAPURAM UPPLIPALAYAM PO COIMBATORE 641015 | COIMBATORE | COIMBATORE | TAMIL NADU | 641015 | L4 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 5 | L5₹93.7 L+₹9.3 L (11.1%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L5 | Rejected-Finance BEING NOT LOWEST TENDER. |
| Sl No | Description | Qty | Unit | M/s.Sai Agency L3 | LAKSHMI ELECTRICAL ENTERPRISES L2 | p.chinnasamy L1 | devan enterprises L7 | eurekaenterprises L6 | SUPER COOL L5 | PRIYA ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE A BOQ | ||||||||||
| 2.00 | M&L for shifting of Air Conditioner, window/Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed by Engineer-in-Charge. | 50 | Job | 1,500 ₹75,000 Lowest | 1,845 ₹92,250 | 2,000 ₹1,00,000 | 1,600 ₹80,000 | 1,545 ₹77,250 | 1,545 ₹77,250 | 1,778 ₹88,900 |
| 3.00 | Disconnecting & taking out unserviceable one and replacemet with new flair nut of dia 5/8", 1/2", 3/8", 1/4", 1/16" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed | 40 | Each | 55 ₹2,200 Lowest | 67 ₹2,680 | 95 ₹3,800 | 55 ₹2,200 Lowest | 60 ₹2,400 | 72 ₹2,880 | 78 ₹3,120 |
| 4.00 | M & L for pressure testing and rectifying the leakages found in the system of window/ split type ACs capacity upto 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning complete all as specified and as directed.
Note:Toping up of gas will be measured and paid seperately | 85 | Each Job | 715 ₹60,775 | 735 ₹62,475 | 1,050 ₹89,250 | 700 ₹59,500 Lowest | 700 ₹59,500 Lowest | 725 ₹61,625 | 788 ₹66,980 |
| 5.00 | Disconnecting & taking out unserviceable one and replacemet with new Hermetic sealed/Rotory new compressor for window type AC of capacity upto 2 Ton including disconnecting the electrical and refrigerant connection of defective sealed unit of window type AC of capacity upto 2 Ton and connection of all pipe line & charging of refrigerant and testing complete complete all as specified and as directed. | 5 | Each Job | 18,200 ₹91,000 | 17,225 ₹86,125 | 15,500 ₹77,500 Lowest | 16,200 ₹81,000 | 19,200 ₹96,000 | 18,200 ₹91,000 | 18,008 ₹90,040 |
| 5.01Note :- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase. | ||||||||||
| 6.00 | Disconnecting & taking out unserviceable one and replacemet with new front grill suitable for window type Air Conditioner of any make upto 2 TR capacity, complete all as specified and as directed. | 5 | Each | 715 ₹3,575 | 735 ₹3,675 | 350 ₹1,750 Lowest | 700 ₹3,500 | 715 ₹3,575 | 715 ₹3,575 | 800 ₹4,000 |
| 7.00 | Disconnecting & taking out unserviceable one and replacemet with new Selector switch, suitable for window type Air Conditioner of any make upto 2 TR capacity, complete all as specified and as directed. | 5 | Each | 325 ₹1,625 | 335 ₹1,675 | 335 ₹1,675 | 315 ₹1,575 Lowest | 315 ₹1,575 Lowest | 315 ₹1,575 Lowest | 400 ₹2,000 |
| 8.00 | Disconnecting & taking out unserviceable one and replacemet with new condenser fan blade suitable for upto 2 Ton split/ window AC complete all as specified and as directed. | 25 | Each | 1,100 ₹27,500 Lowest | 1,175 ₹29,375 | 1,200 ₹30,000 | 1,100 ₹27,500 Lowest | 1,100 ₹27,500 Lowest | 1,245 ₹31,125 | 1,200 ₹30,000 |
| 9.00 | Disconnecting & taking out unserviceable one and replacemet with new Thermostat suitable for window type Air Conditioner of any make up to 2 TR capacity, complete all as specified and as directed. | 5 | Each | 400 ₹2,000 | 415 ₹2,075 | 325 ₹1,625 Lowest | 400 ₹2,000 | 400 ₹2,000 | 445 ₹2,225 | 445 ₹2,225 |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
14 Nov 2025, 6:00 pmClosed
GE AF
kangayampalyam
REPAIR / MAINT OF SUMMER APPLIANCES, SPLIT AC, WINDOW AC, DUCTABLE TYPE AC, CASSETTE TYPE AC AND OTHER E/M WORKS AND REPAIR / MAINT OF COOLING APPLIANCES AND OTHER CONNECTED E/M WORKS AT AF STN SULUR
2025_MES_735881_1
8806/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF SULUR
Please refer to tender document
7 documents required · 7 mandatory
₹1,000
GE AF SULUR
₹1.6 L
19 Dec 2025
17 Oct 2025
17 Nov 2025
17 Oct 2025
14 Nov 2025
7 Nov 2025
19 Oct 2025 - 4 Nov 2025
Amount
SCHEDULE A BOQ
M&L for shifting of Air Conditioner, window/Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed by Engineer-in-Charge.
Disconnecting & taking out unserviceable one and replacemet with new flair nut of dia 5/8", 1/2", 3/8", 1/4", 1/16" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed
M & L for pressure testing and rectifying the leakages found in the system of window/ split type ACs capacity upto 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning complete all as specified and as directed. Note:Toping up of gas will be measured and paid seperately
Disconnecting & taking out unserviceable one and replacemet with new Hermetic sealed/Rotory new compressor for window type AC of capacity upto 2 Ton including disconnecting the electrical and refrigerant connection of defective sealed unit of window type AC of capacity upto 2 Ton and connection of all pipe line & charging of refrigerant and testing complete complete all as specified and as directed.
Note :- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Disconnecting & taking out unserviceable one and replacemet with new front grill suitable for window type Air Conditioner of any make upto 2 TR capacity, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new condenser fan blade suitable for upto 2 Ton split/ window AC complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Thermostat suitable for window type Air Conditioner of any make up to 2 TR capacity, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Over load relay suitable for window type Air Conditioner of any make up to and including 2 TR capacity, including taking down existing one complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Blower motor suitable for window type Air Conditioner of any make upto 2 TR capacity complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Condenser coil after disconnecting the refrigerant connection of defective condenser coil unit of window type AC upto and including 1.5/ 2 Ton and replacing the condenser coil unit connecting the same unit with refrigerant connections complete complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new overload protector for window/ split AC upto 2 Ton capacity complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Condenser coil after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 1.5 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new flexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete complete all as specified and as directed.
M&L for Refrigerant gas, (R22) suitable for cooling equipments supplied and filled complete all as specified and as directed.
M&L for Refrigerant gas, (R 401/R32) suitable for cooling equipments supplied and filled complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new 3 pin metal clad plug top 20 Amps, AC 230 volts for any type of AC complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new dummy nut of dia 3/8" , 1/4" , 5/8" ,1/2" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed
Disconnecting & taking out unserviceable one and replacemet with new PVC insulated multi stranded copper conductor 3 core 2.5 sq.mm, complete all as specified and as directed.
M & L disconnecting electric connection from defective blower/ fan motor and taking out from unit capacity 8.75TR of existing make and transporting to workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burnt winding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding wire as per maunufactrer instructions including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Outdoor fan motor suitable for small shaft condensing coil including blade suitable for ductable AC of 8.75TR complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new liquid line drier filter suitable for 8.75 ton ductable AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete complete all as specified and as directed. Note : Supply and charging refrigerent gas will be measured and paid seperately under relavent items.
Inspection, checking adjustment and minor repair of unserviceable window type/ split type AC /any type any capacity placed at any location includes repair/ replacement of defective parts such as checking of electrical connection, condenser, gas leakage, PCB, condenser fan blade, indoor unit, outdoor unit, compressor, PVC pipe etc, complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
Disconnecting & taking out unserviceable one and replacemet with new single phase single pole contactor suitable for upto 2.0 Ton split type AC complete all as specified and as directed.
Repair and maintenance of inverter type split AC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning complete all as specified and as directed. here under :-
(a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower.
(b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower.
(c) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary.
(d) The work shall be done by a specialized team of Engineer/Technicians of OEM.
(e) Inverter type split AC are installed at the distant height. To carryout servicing of these AC's special T&P (Boomer vehicle) of height 24 meter will be required. The cost of arrangement of special T&P will be inclusive in quoted rate.
Disconnecting & taking out unserviceable one and replacemet with new PCB board of inverter type split type AC for upto 2 Ton (indoor & outdoor) at any location complete all as specified and as directed.
M&L for dismantling the transformer from the stabilizers of 4 KVA and removing the old / burnt transformer and replaced with new transformer complete all as specified and as directed.
M&L for dismantling the transformer from the stabilizers of 5 KVA and removing the old / burnt transformer and replaced with new transformer complete all as specified and as directed.
S & F in repair of following spare parts for 4 KVA/5 KVA capacity stabilizers complete all as specified and as directed.
(a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
Disconnecting & taking out unserviceable one and replacemet with new Digital voltmeter 0-250volt for voltage stabilizers any type as per existing complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Digital timer 230 volt for split ACs any type as per existing complete all as specified and as directed.
Taking down and strip opening of old unserviceable sealed unit compressor of any make from cassette type air conditioner by disconnecting cooling and condensor copper pipe and electric connection carefully and S&F new scroll compressor of capacity 4 ton including charging of refrigerant gas (R-22/R-407C/R 32/R 410) upto required cooling and connecting all the copper pipes, electric connection and testing the AC complete all as specified and as directed. Note : Supply and charging refrigerent gas will be measured and paid seperately under relavent items
Taking down of defective evaporator unit of 4 TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
Disconnecting & taking out unserviceable one and replacemet with new condensing unit of Cassette type AC of capacity 4 TR capacity condensing/ outdoor unit complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete complete all as specified and as directed. Note : Supply and charging of refrigerent gas will be measured and paid for separetly.
Disconnecting & taking out unserviceable one and replacemet with new liquid line drier filter suitable for 4 TR cassette type AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete including taking down existing one complete all as specified and as directed. Note : Supply and charging refrigerent gas will be measured and paid seperately under relavent items.
Disconnecting & taking out unserviceable one and replacemet with new outdoor fan motor suitable for small shaft condensing coil including blade suitable for cassettte AC of 4 TR complete complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new thermal relay 15A, 230 Volt, single phase suitable for cassette type AC of 4 TR capacity complete all as specified and as directed.
M & L for carrying out pressure leak test of 4 ton cassette type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumization complete all as specified and as directed. Note :- Supply & charging of refrigerant gas (R-22/R-407C/R 32/R 410) will be measured and paid for separately
Disconnecting & taking out unserviceable one and replacemet with new multi capacitors 45+6 µfd for cooling appliances and including taking down existing one complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new multi capacitors 50+2 µfd for cooling appliances complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new MCCB four pole, 125 Amp ultimate breaking capacity 25 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new MCCB three pole, 63 Amp ultimate breaking capacity 16 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Double pole MCB 32 Amp, 240 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC tape roll self adhesive of size 1.90cm x 0.125mm x 25m. complete all as specified and as directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed.
Note :- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor alongwith PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M & L carrying out pressure leak test of 8.75 ton ductable split type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumization complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately
Disconnecting & taking out unserviceable one and replacemet with new Indoor blower motor for cooling coil including blower suitable for ductable AC 8.75 TR complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Air filter set suitable for 8.75 ton ductable split type AC complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new PCB (circuit plate) of in-door unit of 8.75 TR ductable split AC complete complete all as specified and as directed.
Taking out of defective wiring of indoor/ outdoor unit of PCB, visual eye damp plates, Supply and fixing new wiring in place of damaged items of capacity of AC 8.75 TR including matching the existing system complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Complete wiring kit for outdoor panel of ductable AC of capacity 8.75 Ton complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Reverse cycle valve suitable for cassette type AC of capacity 8.75 Ton complete complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Low pressure switch for 8.75 ton ductable split type AC complete complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Wall mount remote kit with wire and complete assembly suitable for ductable AC of 8.75 TR complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Thermal relay 20A, 415 Volt, single phase suitable for ductable split type AC of 8.75 TR capacity complete as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new AC 4 Pole power contactor three phase of capacity 40 Amp suitable for LG 8.75 TR capacity ductable split type AC completecomplete all as specified and as directed.
S & F insulation on and around suction and discharge copper tube of size 3/8"/ 5/8" with 6mm thick flexible thermocol heat resistance duly wrapped with sticking tape and finally covered with flexible PVC conduit of 50mm bore complete including taking down existing damaged one complete all as specified and as directed.
Taking down of defective evaporator unit of 2 TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity suitable for existing AC with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
Disconnecting & taking out unserviceable one and replacemet with new condensing unit of Cassette type AC of capacity 2 TR capacity condensing/ outdoor unit complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Note : Supply and charging of refrigerent gas will be measured and paid for separetly.
M & L for carrying out pressure leak test of 2 ton cassette type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumization complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately
Disconnecting & taking out unserviceable one and replacemet with new Outdoor fan motor suitable for small shaft condensing coil including blade suitable for cassette AC of 2 TR complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new PCB (circuit plate) of in-door unit of 2.0 TR cassette type split AC complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new thermal relay 7.5A, 230 Volt, single phase suitable for cassette type AC of 2 TR capacity complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new reverse cycle valve suitable for cassette type AC of capacity 2 Ton complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new pipe thermister suitable for cassette type AC of capacity 4 Ton complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new reverse cycle valve suitable for cassette type AC of capacity 4 Ton complete including taking down existing one complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new PCB (circuit plate) of in-door unit of 4.0 TR ductable split AC complete including taking down existing one complete all as specified and as directed.
Removing the window/split type AC any type upto 2 ton capacity of any make from any location for carrying out servicing complete as and when ordered and installing back at original location, testing and commissioning complete all as specified and as directed. by Engineer-in-Charge. Note :-The rate of following deemed to be included in quoted rate :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary d) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, materials & labour, tools and plants, and back in on final position complete (e) The work shall be done by a specialized team of Engineer/Technicians of OEM.
Disconnecting & taking out unserviceable one and replacemet with new filter suitable for split type Air Conditioner of any make upto 2 TR capacity, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new discharge valve suitable for 1.5 Ton/2 Ton of split type AC all as specified and directed
Disconnecting & taking out unserviceable one and replacemet with new DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton and including taking down existing unserviceable one of any capacity and at any location complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new blower of indoor unit suitable for 1.5 Ton / 2 Ton split AC at any location complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Remote sensing unit for upto 2.0 TR split type AC all as specified and as directed.. Make : As per existing AC at the site.
Disconnecting & taking out unserviceable one and replacemet with new copper tube 15 mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new metal frame stand factory made outdoor type to hold outdoor split unit of ACs complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Copper tube, 9 mm bore superior quality suitable for refrigeration and discharge lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof including taking down existing one complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new filter suitable for split type Air Conditioner of any make up to 1.5/ 2 TR capacity complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Front grill suitable for split type Air Conditioner of any make up to 2 TR capacity, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Hermetic sealed/Rotory new compressor for 2 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Hermetic sealed/Rotory new compressor for 1.5 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete complete all as specified and as directed.
Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Disconnecting & taking out unserviceable one and replacemet with new Condenser coil after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 2.0 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new over load relay suitable for split type Air Conditioner of any make up to 2.0 TR capacity, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new remote assembly corded/cordless for any type and size of split type ACs, upto 2.0 TR complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Blower motor suitable for split type Air Conditioner of any make up to 2 TR capacity complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Ton complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Condenser Fan motor suitable for split type Air Conditioner of any make up to and including 1.5/2.0 TR capacity, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new suction valve suitable for 1.5 Ton/2 Ton of split type AC of existing make complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new indoor unit including blower fan , PCB board and all accessaries capacity 1.5/2.0 Ton split type A/C any type complete all as specified and as directed by Engineer-in-charge
Disconnecting & taking out unserviceable one and replacemet with new outdoor unit including condenser fan motor, and all accessaries capacity 1.5/2.0 Ton split type A/C any type complete all as specified and as directed by Engineer-in-charge.Note:- (a) Old Unserviceable outdoor unit shall be deposited to MES store yard.
Disconnecting & taking out unserviceable one and replacemet with new 4 KVA capacity Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 170V - 250V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as per manufacturers instructions and directed by Engineer-in-Charge.Note:- (a) Old Unserviceable Voltage stablizers shall be deposited to MES store yard.
Disconnecting & taking out unserviceable one and replacemet with new 5 KVA capacity Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 170V - 250V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as per manufacturers instructions and directed by Engineer-in-Charge.Note:- (a) Old Unserviceable Voltage stablizers shall be deposited to MES store yard.
Disconnecting & taking out unserviceable one and replacemet with new 5 KVA capacity Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 170V - 250V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as per manufacturers instructions and directed by Engineer-in-Charge.Note:- (a) Old Unserviceable Voltage stablizers shall be deposited to MES store yard.
Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator 165/180/175/210/260/280/300/310/320/335 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 300 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed. Note:Topping up of gas will be measured and paid seperately
Disconnecting & taking out unserviceable one and replacemet with new hermetically sealed new compressor for 260 to 310 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 260 to 310 litres. Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Disconnecting & taking out unserviceable one and replacemet with newcondensing coil for refrigerator of capacity 260 to 310 Ltr complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new Chiller tray suitable for Refrigerator of any make, 260 to 310 litres capacity, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Evaporator coil, suitable for refrigerator of 260 to 310 ltrs any make size and type complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Vegetable tray suitable for Refrigerator of any make, 260 to 310 litres capacity, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new ice superior quality plastic/PVC Ice cube tray for refrigerator of capacity 260 Ltrs to 310 ltrs complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new electric bulb 20 watt 230v threaded type for refrigetator of Capacity 260 ltrs to 310 ltrs complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new Freezer compartment including door and accessories suitable for refrigeratorr 280, 300, 310 and 320 ltrs capacity refrigerator complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC shelf transparent type of tough plastic suitable for refrigerator of capacity 300 ltrs complete all as specified and as directed.
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed. Note:Topping up of gas will be measured and paid seperately
Disconnecting & taking out unserviceable one and replacemet with new hermetically sealed new compressor for 165 to 255 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 255 litres complete all as specified and as directed. Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Disconnecting & taking out unserviceable one and replacemet with new condensing coil for refrigerator of capacity 165 to 255 Ltr complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new Chiller tray suitable for Refrigerator of any make, 165 to 255 litres capacity, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new magnetic beading for refrigerator of cap 165 ltrs to 335 ltrs complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new Relay, box type, suitable for refrigerator of any make 165 to 335 litres capacity complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Evaporator coil, suitable for refrigerator of 165 to 255 ltrs any make size and type complete all as specified and as directed.
M & L for preparing the old painted surface of refrigerator of capacity 165 litres to 335 litres and spray painting with synthetic enamel paint of approved colour complete all as specified and as directed
Note for item No 116 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
Disconnecting & taking out unserviceable one and replacemet with new Vegetable tray suitable for Refrigerator of any make, 165 to 255 litres capacity, complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Thermostat, suitable for refrigerator of any make 165 to 335 litres capacity complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Gasket, suitable for door of Refrigerator of any make, 165 to 260 litres capacity,complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Multi capacitors 2 µfd for cooling appliances complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Filter of refrigerator complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Timer and sensor of Refrigerator complete all as specified and as directed as per Make of Refrigerator
Disconnecting & taking out unserviceable one and replacemet with new Over load protector for refrigerator any description complete all as specified and as directed..
Disconnecting & taking out unserviceable one and replacemet with new Copper capillary tube suitable for refrigerator any description complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new Starting relay suitable for refrigerator complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Multi capacitors 4 µfd for cooling appliances complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Multi capacitors 2.5 µfd for cooling appliances complete all as specified and as directed.
M&L for pressure testing and rectifying the leakage found in the system of Deep freezer of capacity 320 litres including vacuuming and charging the refrigerant Refrigerant gas R-134 a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately
Disconnecting & taking out unserviceable one and replacemet with new hermetic sealed new compressor 1/6 HP suitable for deep freezer of capacity 320 ltr including disconnecting the electrical and refrigerant connection of defective sealed unit of deep freezer 320 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Disconnecting & taking out unserviceable one and replacemet with new Copper capillary tube of Deep freezer any description complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Condenser fan motor of Deep freezer complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Thermostat for Deep freezer complete all as specified and as drected.
Disconnecting & taking out unserviceable one and replacemet with new Starting relay of Deep freezer complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Filter for Deep freezer complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Over load protector for Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
Supply and charging of Refrigerant gas, (R-22/R-134(a)/R-407(c)) Freon suitable for cooling equipments like water cooler, refrigerator, deep freezer air conditioner etc of any type and capacity complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new multi capacitors 60 µfd for cooling appliances complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new multi capacitors 50+5 µfd for cooling appliances complete all as specified and as directed.
M&L for dismantling the transformer from the voltage stabilizers of following capacity and removing the old / burnt transformer and replaced with new transformer complete all as specified and as directed
S & F in repair of following spare parts for 1 KVA to 2 KVA capacity voltage stabilizers complete all as specified and as directed
(a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/200 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately
Disconnecting & taking out unserviceable one and replacemet with new hermetic sealed new compressor for water cooler 150 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 ltr and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and as directed Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Disconnecting & taking out unserviceable one and replacemet with new Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc suitable for water cooler of any make of 150 ltr capacity, complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Door gasket suitable for lid of water cooler upto 150 litres capacity, complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Stainless steel tray suitable for water cooler of 150 Litres capacity complete all as specified and as directed
Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour complete all as specified and as directed
M&L for preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed
Note for item No 154:- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately
Disconnecting & taking out unserviceable one and replacemet with new hermetic sealed new compressor for water cooler 60/120 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Disconnecting & taking out unserviceable one and replacemet with new Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc suitable for water cooler of any make of 60/120 litres capacity, complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Candle (filter) 10” size complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Self closing push type Bib tap 15mm dia made out of cast copper alloy chromium plated suitable for water cooler conforming to ISI mark, including testing and leak proof etc.complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC connection pipe 450mm long 15 mm dia with brass unions with washers on both the ends complete all as specified and as directed
Supply and fixing ball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new gun metal gate valve 15mm dia including GI nipple complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new PVC drain out pipe 30mm dia bore as per existing including providing necessary GI clamps, nut bolt etc.complete all as specified and as directed
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately
Disconnecting & taking out unserviceable one and replacemet with new hermetic sealed new compressor for water cooler 40/80 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
M&L for repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed.
Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour complete all as specified and as directed
Note for item No 167 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
Disconnecting & taking out unserviceable one and replacemet with new Stainless steel tray suitable for water cooler of 40/ 80 litres capacity complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Evaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity complete all as specified directed.
Supply and fixing in repair of Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc suitable for water cooler of any make of 40/80 litres capacity, complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new Condensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity complete all as specified directed.
Disconnecting & taking out unserviceable one and replacemet with new Multi capacitors 45 µfd for cooling appliances complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Multi capacitors 6 µfd for cooling appliances complete all as specified and as directed.
M&L for preparing the old painted surface of the water coolers of capacity up to 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed
Note for item No 174:- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
Disconnecting & taking out unserviceable one and replacemet with new filter for water cooler of any size any make complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Carbon (filter) 12” size complete all as specified and as directed.
Routine repair and annual maintenance of Aqua guards installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters complete all as specified and as directed by Engineer-in-charge, for the any models / types, for 09 month period of each aqua guard - 18 Nos Notes :- (a) The contractor shall make AMC contract with the authorised service agency of best water cooler and repair/ maint shall be carried out through the authorised person of OEM only. (b) The rate quoted shall deem to be included for carried out all repairs to water cooler noticed during the period 09 months.
Disconnecting & taking out unserviceable one and replacemet with new PCB Card 12 Volt of DC capacity for Aquaguard incl dismantling old unsv complete all as specified and directed.
Routine repair and annual maintenance of best water doctor of tank capacity 25/ 44 ltrs installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters complete all as specified and as directed by Engineer-in-charge, Make :- Best water doctor model No. HIMA-5NC of flow rate 100 ltr/ hr - 2 Nos Notes :- (a) The contractor shall make AMC contract with the authorised service agency of best water cooler and repair/ maint shall be carried out through the authorised person of OEM only. (b) The rate quoted shall deem to be included for carried out all repairs to water cooler noticed during the period 09 months.
Routine repair and annual maintenance of best water doctor of tank capacity 40/ 80 ltr installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters complete all as specified and as directed by Engineer-in-charge, Make :- Best water doctor model No. UV 7 NC of flow rate 200 ltr/ hr - 9 Nos Notes :- (a) The contractor shall make AMC contract with the authorised service agency of best water cooler and repair/ maint shall be carried out through the authorised person of OEM only. (b) The rate quoted shall deem to be included for carried out all repairs to water cooler noticed during the period 09 months.
Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance alongwith blower assembly filter and other components including checking electrical connections complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new blower motor assembly of Air curtain unit of any type capacity and length, single phase AC, 230 Volts as including electrical connections complete all as specified and as directed
Periodical servicing, calibaration and maintenance of Electric Air shower installed at TRCD/CRRW/75 RMU/Avionics for smooth functioning of hudraulic doors, maintaining required air pressures, lighting etc all as directed.- 16 Nos
Note for Item No 183 :- (i) The unit quoted rate shall deem to be included to carried out all repairs noticed during the period. (ii) Repairs/ maintenance shall be carried out through the authorised service agency only as per instructions recommended by the original manufacturer. (iii) The authorised service agency must be attended as and when called for urgent nature of repair of synchronous panel irrespective of number of visit. (iv) Otherwise, periodicity shall be around 03 to 04 months or as per manufacturer instruction. (v) Replacement of minor items shall be included in the unit quoted rate. (vi) Replacement of any major defective items will not be included in the scope of work. However, the decision of Accepting Officer is final and binding in deciding, whether the defective item is major or minor in nature. (vii) Payment shall be made thrice for the period of 09 months proportionately.
Disconnecting & taking out unserviceable one and replacemet with new PCB board for Electric Air shower installed at TRCD/CRRW/75 RMU/Avionics for smooth functioning of hudraulic door all as directed.
Disconnecting & taking out unserviceable one and replacemet with new door magnet of Electric Air shower installed at TRCD/CRRW/75 RMU/Avionics for smooth functioning of hudraulic doors, maintaining required air pressures, lighting etc all as directed.
Disconnecting & taking out unserviceable one and replacemet with new blower motor of Electric Air shower installed at TRCD/CRRW/75 RMU/Avionics for smooth functioning of hudraulic doors, maintaining required air pressures, lighting etc all as directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed.
Note for item No 187: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor alongwith PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Disconnecting & taking out unserviceable one and replacemet with new MCCB four pole, 125 Amp ultimate breaking capacity 25 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new MCCB three pole, 63 Amp ultimate breaking capacity 16 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 2.5 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 2.5 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed.
Note for item No 190: (a) 2 runs of 2.5 sqmm cable along with one run of 2.5 sqmm cable for earth conductor alongwith PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Disconnecting & taking out unserviceable one and replacemet with new Triple pole MCB 25 to 63 Amp, 415 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Triple pole Neutral MCB 16 to 32 Amp, 415 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
Supply and fix in repair Triple pole Neutral MCB 40 to 100 Amp, 415 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
M&L for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one 15A Socket & switch point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 4 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly including taking down existing point wiring complete all as specified and as directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed.
Note for item No 195: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor alongwith PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
LAKSHMI ELECTRICAL ENTERPRISES (BID ID -3473447)
M/s.Sai Agency (BID ID -3470902)
PRIYA ENTERPRISES (BID ID -3473834)
SUPER COOL (BID ID -3474509)
eurekaenterprises (BID ID -3474430)
devan enterprises (BID ID -3474273)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BOQ_824024.xls
BOQ • 2.44 MB
8806TENDER.pdf
Tender Documents • 0.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .