Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.2 LAdmitted-Finance | -4.51% | ₹8.2 L | L1 | Admitted-Finance |
| 2 | L2₹8.6 L+₹38,906.16 (4.72%)Admitted-Finance | +0.00% | ₹8.6 L+₹38,906.16 (4.72%) | L2 | Admitted-Finance |
| 3 | L3₹9.1 L+₹82,039.37 (9.96%)Admitted-Finance | +5.00% | ₹9.1 L+₹82,039.37 (9.96%) | L3 | Admitted-Finance |
Tender Value
₹75 L
EMD Value
₹1.5 L
Closing Date
27 Apr 2026, 2:00 pmClosed
Executive Engineer,PHED,Distt Rural Div.I,Bikaner
Executive Engineer,PHED,Distt Rural Div.I,Bikaner
Rate Contract for Upgradation of Panel, Lighting and Automation under Distt Rural Div I Bikaner
2026_PHCJA_552780_1
NIB 03 2026-27 D1
Open Tender
Electrical Works
Percentage
300 days
Bikaner
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Executive Engineer,PHED,Distt Rural Div.I,Bikaner
₹1.5 L
Yes
6 May 2026
18 Apr 2026
27 Apr 2026
18 Apr 2026
27 Apr 2026
18 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing Laying Jointing of HDPE Pipe Line | - | - | - | - |
| 2 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required. | - | - | - | - |
| 3 | High Power LED Flood Light Minimum lumen outpu 3900 lm | - | Each | - | - |
| 4 | High Power LED Flood Light Minimum lumen output 6500 lm | - | Each | - | - |
| 5 | High Power LED Flood Light Minimum lumen output 10400 lm | - | Each | - | - |
| 6 | High Power LED Flood Light Minimum lumen output 13000 lm | - | Each | - | - |
| 7 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing and secondary lens on each LED/ integrated lens diffuser without cover & should be High power LED of 3 to 5 watt each . The System efficacy >=135 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required. | - | - | - | - |
| 8 | LED Street Light fixture with Minimum lumen output 6075 lm | - | Each | - | - |
| 9 | LED Street Light fixture with Minimum lumen output 8100 lm | - | Each | - | - |
| 10 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 33 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TD03.pdf
Tender Documents • 0.98 MB
BOQ_984952.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .