Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.2 LAdmitted-Finance | -4.51% | ₹8.2 L | L1 | Admitted-Finance |
| 2 | L2₹8.6 LAdmitted-Finance | +0.00% | ₹8.6 L | L2 | Admitted-Finance |
| 3 | L3₹9.1 LAdmitted-Finance | +5.00% | ₹9.1 L | L3 | Admitted-Finance |
Tender Value
₹75 L
EMD Value
₹1.5 L
Closing Date
27 Apr 2026, 2:00 pmClosed
Executive Engineer,PHED,Distt Rural Div.I,Bikaner
Executive Engineer,PHED,Distt Rural Div.I,Bikaner
Rate Contract for Upgradation of Panel, Lighting and Automation under Distt Rural Div I Bikaner
2026_PHCJA_552780_1
NIB 03 2026-27 D1
Open Tender
Electrical Works
300 days
Bikaner
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Executive Engineer,PHED,Distt Rural Div.I,Bikaner
₹1.5 L
Yes
6 May 2026
18 Apr 2026
27 Apr 2026
18 Apr 2026
27 Apr 2026
18 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Providing Laying Jointing of HDPE Pipe Line | - | - | - | - | BI01010001010000000000000515BI0100001174 |
| 2 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required. | - | - | - | - | BI01010001010000000000000515BI0100001175 |
| 3 | High Power LED Flood Light Minimum lumen outpu 3900 lm | - | Each | - | - | BI01010001010000000000000515BI0100001176 |
| 4 | High Power LED Flood Light Minimum lumen output 6500 lm | - | Each | - | - | BI01010001010000000000000515BI0100001177 |
| 5 | High Power LED Flood Light Minimum lumen output 10400 lm | - | Each | - | - | BI01010001010000000000000515BI0100001178 |
| 6 | High Power LED Flood Light Minimum lumen output 13000 lm | - | Each | - | - | BI01010001010000000000000515BI0100001179 |
| 7 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing and secondary lens on each LED/ integrated lens diffuser without cover & should be High power LED of 3 to 5 watt each . The System efficacy >=135 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required. | - | - | - | - | BI01010001010000000000000515BI0100001180 |
| 8 | LED Street Light fixture with Minimum lumen output 6075 lm | - | Each | - | - | BI01010001010000000000000515BI0100001181 |
| 9 | LED Street Light fixture with Minimum lumen output 8100 lm | - | Each | - | - | BI01010001010000000000000515BI0100001182 |
| 10 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 33 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. | - | - | - | - | BI01010001010000000000000515BI0100001183 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TD03.pdf
Tender Documents • 0.98 MB
BOQ_984952.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid