Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹15.3 L+₹86,368 (5.98%)Rejected-Finance 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹15.6 L+₹1.1 L (7.90%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹15.7 L+₹1.3 L (8.72%)Rejected-Finance VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹15.9 L+₹1.4 L (10.0%)Rejected-Finance 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
15 Jul 2021, 6:00 pmClosed
Shri R Durga Shyam, EE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REWIRING AND REPLACEMENT OF ELECTRICAL FITTINGS OF MD / OTM ACCN AT AFS KALAIKUNDA UNDER GE(AF) KALAIKUNDA.
2021_MES_453716_1
8678/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN KALAIKUNDA
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Kalaikunda
₹40,000
Yes
9 Aug 2021
22 Jun 2021
16 Jul 2021
22 Jun 2021
15 Jul 2021
3 Jul 2021
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M & L for concealed point wiring for one light/fan point with 1.50 sqmm (nominal area), FRLSH PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade,ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories(PVC Casing and caping of size 25 mm , ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLSH muti stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly, including sunk sheet steel terminal box GI/MS/ pressed steel terminal box to be conclead in wall, duly painted with two coates of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface , including laminated hylum sheet cover, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer including making good as per existing complete all as specified and directed. Note : (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge) (III)Wiring to be done as per approved colour code in IE rule. (iv) Sub circuit from MCB DB to Switch board should be of 3 x 2.5 Sqmm Cable and the length of cable in this case should be of max 3 x 15 Mtr from the distribution board. Beyond this length it shall not be considered as point wiring and the whole length to be measured in sub main wiring. (v) The cable length from switch board to fittings/ fixture should be of 3 x 1.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring..
All as per item No. 2 here-in-before but for 3 pin socket outlet, 5 Amp on the same board with other switches, complete all as specified and directed.
All as per item No. 2 here-in-before, but for 3 pin 5 amp switch socket combination on independent board with other switch complete all as specified and directed.
All as per item No. 2 here-in-before, but for bell buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 Sqmm. complete all as specified and directed.
All as per item No. 2 here-in-before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
All as per item No.2 here -in- before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Industrial metal clad socket with 4.0 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete but excluding sunken box and hylam sheet all as specified and directed. .
M & L Point wiring with PVC insulated unsheathed electric cable 1100 volts grade, single core,FRLS cable having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area, ISI marked, drawn in existing concealed/ surface conduit with 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor FRLS cable, ISI marked as continuous earth conductor connected to earth dolly by providing suitable lugs including new laminated hylum sheet cover of min 2.8 mm thick , ISI marked of Make" Hylem" of suitable sizes to be fixed/ mounting on existing MS/ GI sunkun boxes for mounting of fittings like switches, sockets, fan regulators etc fixed with galvanised screw and cup washer. complete all as specified and directed for the following. Note : (i) Wiring to be done as per arroved colour code. (ii) Sub circuit from MCB DB to Switch board should be of 3 x 2.5 Sqmm Cable and the length of cable in this case should be of max 3 x 15 Mtr from the distribution board. Beyond this length it shall not be considered as point wiring and the whole length to be measured in sub main wiring. (iii) The cable length from switch board to fittings/ fixture should be of 3 x 1.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring. (iv) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (v) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge)
(a) One light/fan point controlled by one switch.
(b) One bell point controlled by one bell Push
(c) One 5 Amps socket out let point controlled by one switch on independent board.
(d) All as per item 8 herein before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
(e) All as per item 8 herein before but wiring with 4.0 Sq mm FRLSH mutistranded copper conductor cable for Industrial metal clad socket with 4.0 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
M & L Point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLS cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLS copper wire, ISI marked of green colour for continous earth, excluding sunken box , laminated hylum sheet cover but including PVC box for mounting of fittings like switches, sockets, fan regulators etc. complete all as specified and directed. Note :(i) Wiring to be done as per arroved colour code. (ii) Sub circuit from MCB DB to Switch board should be of 3 x 2.5 Sqmm Cable and the length of cable in this case should be of max 3 x 15 Mtr from the distribution board. Beyond this length it shall not be considered as point wiring and the whole length to be measured in sub main wiring. (iii) The cable length from switch board to fittings/ fixture should be of 3 x 1.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring..
(a) One 5 Amps socket out let point controlled by one switch on independent board.
(b) All as per item 9 herein before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
M & L Point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLS cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLS copper wire, ISI marked of green colour for continous earth, including sunken box made out GI/MS/ pressed steel terminal box to be conclead in wall, duly painted with two coated of aluminium paint on internal surface and two coat of anti corrosive paint over external surface, including laminated hylum sheet cover, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code. (ii) Sub circuit from MCB DB to Switch board should be of 3 x 2.5 Sqmm Cable and the length of cable in this case should be of max 3 x 15 Mtr from the distribution board. Beyond this length it shall not be considered as point wiring and the whole length to be measured in sub main wiring. (iii) The cable length from switch board to fittings/ fixture should be of 3 x 1.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring..
(a) One light/fan point controlled by one switch.
(b) One call bell point controlled by one push button on the same board with other switces or independent.
(c) One light point controlled by two 2-way switches.
(d) One 3 pin socket outlet 5 Amps on independent board.
(e) One 3 pin socket outlet on same board with other switch.
(f) - All as per item 10 herein before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
(g) All as per item 10 herein before but wiring with 4.0 Sq mm FRLSH mutistranded copper conductor cable for Industrial metal clad socket with 4.0 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete excluding sunken box and hylam sheet all as specified and directed.
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S&F Polycarbonate switch piano, flush button, single pole, two way, 5 Amp, 240 volts ISI marked, (white colur) complete all as specified and directed
Supply and fixing, Polycarbonate ceiling rose, surface type, 3 terminal, 240 , ISI marked, (white colur) complete all as specified and directed
Supply and fixing Polycarbonate switch socket combination 2-in-1, 3 pin 5 Amps, 240 volts, flush type(white colur) complete all as specified and directed
S&F Polycarbonate switch socket combination flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete as directed .
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S&F Polycarbonate angular lamp holder with back plate, suitable for batten fittings complete all as specified and directed
S & F buzzer, din dong, suitable for single phase, AC, 240 volts complete all as specified and as directed.
S & Fix Bell push, flush type, SP, 5 amp, 240V complete all as specified and as directed.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
Supply and Fixing Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed by EIC.
Supply and Fixing Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed by EIC.
Supply and Fixing Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in but including PVC casing caping not less than 25 mm width, ISI marked, double locking type including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface complete all as specified and directed by EIC.
Supply and Fixing Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in but including PVC casing caping not less than 25 mm width, ISI marked, double locking type including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface complete all as specified and directed by EIC.
Supply and Fixing Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in but including PVC casing caping not less than 38 mm width ISI marked double locking type including one including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface complete all as specified and directed by EIC.
Supply and Fixing Sub main wiring with Four single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 38 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 6.0 sqmm + 2 x 6.0 Sqmm earth wire) .
Supply and Fixing Sub main wiring with Four single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 10 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 40 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 10.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 10.0 sqmm + 2 x 10.0 Sqmm earth wire) .
S&F DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 6 way, double door with 100 Amp,25 KA,TP MCCB as incomer (Vertical type double door, 100 Amps, TP, 25 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 250 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507746 Model: (Ekinox-3) , MCCB 100 Amp, Cat No. 420045 Model : DPX -3 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S&F DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 4 way, double door with 63 Amp,25 KA,TP MCCB as incomer (Vertical type double door, 63 Amps, TP, 25 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 IK 09, As Per IEC 61439-3, with 250 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507745 Model: (Ekinox-3) , MCCB 63 Amp Cat No. 420043 , Model : DPX -3 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S&F DB Box, in sheet metal enclosure VT DB TPN, MCB DB TPN 4 way, double door, with MCB as incomer, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 54, IK 09, As Per IEC 61439-3, with 100 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, with provision for FP MCB as incomer and SP/TP MCB`s as out going, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. Make- Legrand Cat Part No. 507725 or equivalent in Seimens/ Schinder. Note : (i) MCB and DB box shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 12 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cabel management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507612 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 8 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cabel management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507611 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar,4 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cabel management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507611 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 2 way, single door without bus bar, enclosure made up of CRCA sheet steel RAL 9003 powder coated, IP 30 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder.
S & F MCB SP (Single Pole) 6-32 Amp , AC , 220 Volt , 10 kA , C-curve , ISI marked, as per IEC 60898-1 2002 complete all as specified & directed.
S & F MCB SPN (Single Pole and Neutral) 6-32 Amp , AC , 220 Volt , 10 kA , C-curve , ISI marked, as per IEC 60898-1 2002 complete all as specified & directed.
S & F MCB, TP (Triple Pole) , 6-32 Amp , AC , 415 Volt , 10 kA , C-curve , ISI marked, as per IEC 60898-1 2002 complete all as specified & directed.
S & F MCB, 4 Pole, (Four Pole) 40-63 Amp , AC , 415 Volt , 10 kA , C-curve , ISI marked, as per IEC 60898-1 2002 complete all as specified & directed.
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, complete all as specified and as directed. Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T.
S&F LED 18/20 Watt tube light fitting (T8 type) ,single end connection type including LED retrofit tube lamp 18/ 20 W , 240 Volt, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, single side connection type complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed
S&F in repair LED tube lamp 18/20 Watt (reterofit type, T8 pattern, single side connection) 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100 Lm/W, to be fixed in existing or new batten/ patti including changing the wiring suitable for T8 LED retrofit lamp in existing tube light fitting complete.
S&F in repair LED 9/10 Watt tube light fitting intergated type, 240 v, PF > 0.90, colour Temp 6500 K, suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed .
S&F in repair LED lamp 18 Watt 4 Pin type, colour Temp 6500K, retrofit type in existing fitting with necessary change in wiring complete all as specified and directed by Engineer in charge.
S&F in repair LED light with pressure die-cast housing along with prismatic polycarbonate diffuser and LED's with secondary optics and IP-65 protection of 25 watt,PF>0.9, having efficacy 100 Lumen per watt for building security light complete all as specified and directed by Engineer in charge.
S&F in repair LED bulkhead light of 12 W with pressure die-cast housing along with polycarbonate diffuser and LED's IP-65 protction of watt,PF>0.95 complete all as specified and directed by Engineer in charge. Note for item no.40 to 45 :All LED lights have replacement warranty of 3 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of 3 year replacement warranty certificate.
M&L for repairing distribution box(DB's) of any rating, any size by proper dressing of wirings,providing lugs, screw, nuts , cleaning of the burned surfaces etc, tightening of all the connections of incoming and outgoings from the MCB's/ DB, connecting Earthing connection to each earth dolly including fixing of DB cover by providing screws etc complete all as specified and directed by Engr-in-Charge.
S&F PVC casing caping of min 25 mm dia exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping including taking down old u/s all as specified and directed by Engineer in charge.
Supply and fixing in repair PVC insulated multistranded Copper conductor, sheathed round cable ISI marked 2.5 sqmm x 3 core complete all as specified and directed by Engr-in-charge. Make : Finolex/ Havells
Taking down ceilling fans/Exhaust fan, sealing cable end, including painting of fan with systhetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc. and repositioning & hanging ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as directed by engineer in charge.
M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, refilling of pit with agriculture soil, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed. (Note: (i) Unit rate of earthing deemed to be included with GI wire 4 mm, GI pipe light grade protection pipe 15 mm up to 7.5 RM) (ii) Since the resistivity of soil is high contractor shall bring the agriculture soil from out side defence land to fill the earth pit.
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electric connections all as directed specifed and directed by EIC Make : Secure (Model Saral) or eqivelent in L&T Note : Old meter to be deposite in AGE E/M store.
S&F in repairs laminated hylum sheet cover, ISI marked of Make" Hylem" cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in loc with new galvanised screw and cup washer complete all as specified and directed by EIC of following sizes.
(a) 11 x 13 inches
(b) 9 x 11 inches
(c) 5 x 8 inches
(d) 5 x 5 inches
S&F galvanised steel tubing light grade 15 mm dia for protection of GI wire fixed/ laid on floor/wall fixed with including fittings all as directed specifed and directed
Supply and fixing earth continuity conductor or main earthing lead of 4 mm GI wire laid in pipe/ fixed to wall on batton or recess or chases or buried in ground or drawn in conduit / pipe or any other indicated situation for loop earthing etc including jointing by using suitable size lugs, GI nuts, bolts and washer complete and all as specified and directed by GE.
Supply and fixing in repair switch socket combination 5-in-1, 5A/15 Amps, 6 pin, 240 volts controlled by one switch, flush type including PVC mouting box complete all as specified and directed by Eng in Charge. Make Anchor Penta , Cat No. 39593
Taking down existing u/s CFL light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , white powder coated CRCA housing with LEDs, seam less front frame with flat white high transmission acrlyic cover, classic design with glare free soft illumination, cool white,including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed Note for item :All LED lights have replacement warranty of 3 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer .
S&F in repair Polycarbonate angular lamp holder with back plate, suitable for batten fittings all as specified and directed
S&F in repair modular switch piano 1 way 6A, 1 Module complete all as specified and directed
S&F in repair modular switch piano 1 way 16A, 1 Modulecomplete all as specified and directed
S&F in repair modular bell switch 1 way , 1 Module complete all as specified and directed
S&F in repair modular socket 6A/16A 2/3 Pin combined -2 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings including taking out u/s all as specified and directed by Engr- in - Charge : Make : Anchor / L& T/ Havells
S&F in repair modular switch socket combination 16A , 6 Pin combined -3 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings complete all as specified and directed
Supply and fixing in repair of stepped type Modular electronic fan regulator 2 module , 120 watt flush type , (deluxe) on the existing hylam laminated sheet etc as required. Make: Anchor (Deluxe /Code:-14502) / L&T/ Havells
Supply and Fixing in repair Modular white cover plate with frame for 1 Module icomplete all as specified and directed
Supply and Fixing in repair Modular white cover plate with frame for 2 Module complete all as specified and directed
Supply and Fixing in repair Modular white cover plate with frame for 4 Module complete all as specified and directed
Supply and Fixing in repair Modular white cover plate with frame for 6 Module complete all as specified and directed
Supply and Fixing in repair Modular white cover plate with frame for 8 Module complete all as specified and directed
Supply and Fixing Modular metal flush box of 1/2 module including taking out unserviceable including make good to match with existing surface complete all as specified and directed by EIC.
Supply and Fixing in repair Modular metal flush box of 4 module including taking out unserviceableincluding make good to match with existing surface complete all as specified and directed by EIC.
Supply and Fixing in repair Modular metal flush box of 6 module including taking out unserviceableincluding make good to match with existing surface complete all as specified and directed by EIC.
Supply and Fixing in repair Glitter LED lamp 7 watt with base GU - 10, CCT 2700K, 560 Lumen, with 2.5K surge protection including taking down unserviceable complete all as specified and directed
Supply and Fixing LED bulb 10 watt with B22 base, 1100 lumen, 6500 K. complete all as specified and directed
M&L for repairing / replacement of old rusted sunken box after removing hylam plate and providing new MS /GI suncken box flush in wall including fixing of hylam sheet and making good of surface to match with existing complete for following size of boxes.
(a) 4 x 4 inchs
(b) 7 x 4 inchs
(c) 10 x 8 inchs
SENCO
NAVYUG CONSTRUCTION
M/s Santosh Industrial Corporation
Ultimate Solution Company
M/S ELECTROVISION
M/S OM BUILDERS
NATIONAL CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .