Executive Engineer (EnM) M-8
Office of the Executive Engineer (EnM) M-8 Nangloi Phase-III, Near Maharaja Surajmal Stadium Metro Station New Delhi-110041.
NIT No.15 /EE(EnM)M-8/2026-27 Item 05
2026_DJB_300011_1
NIT No.15 /EE(EnM)M-8/2026-27 Item 05
Open Tender
Civil Works
Works
45 days
Nangloi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹16,700
Yes
14 Oct 2026
14 Oct 2026
21 Oct 2026
14 Oct 2026
21 Oct 2026
14 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Air circuit breakers (ACB), 3 pole, 1600Amp.MDO 50ka type with microprocessor based with both side terminal adapter Make L&T | 1 | No. | 80 | ₹80 |
| 1.02 | MCCB 400Amp. TP 415V with spreader terminal 50Ka Make L&T | 1 | No. | 80 | ₹80 |
| 1.03 | Motor protection Relay with Thermal over load, short circuit, earth fault protections, Make: L&T | 4 | Nos | - | - |
| 1.04 | Replacement of Amp. Meter digital with selector switch Make: L&T | 8 | Nos | - | - |
| 1.05 | Replacement of Volt Meter digital with selector switch Make: L&T | 2 | Nos | - | - |
| 1.06 | Replacement of UV release Make: L&T | 2 | Nos. | - | - |
| 1.07 | Retrofitting of ACB (1600A,3 Pole) as above in existing panel by carrying out following works:- 1) Supply of necessary hardware, supports etc. 2) Making /supply of M.S angle base frame/supports of size as suitable to the mounting of new ACB. Fixing of the same at the panel chamber with the help of nuts bolts /welding etc. as suitable for installation of new ACB /their cradles. 3) Dismantling the existing circuit breaker from the chambers of the LT panel including its cradles and disconnecting the bus bar connections with the main bus bars, disconnecting the outgoing cables etc 4) Installation of new ACB cradle in the panel by the help of nuts bolts etc. in proper alignment for connecting the bus bars. Fixing the ACB in the cradles in the proper condition including checking the movement. Making control wiring connection for the ACBs. 5) Connecting the main bus bars to the incoming sides of the ACB by re-arrangement /modification/addition of bus bar lengths in Aluminum construction for retrofitting of ACB. 6) making a new M.S. door in 2mm CRCA Sheet ,powder coated as suitable size to match symmetry, Connecting the bus bar at the outgoing side of the ACB by re-arrangement/ modification/addition of bus bar lengths in Aluminum for retrofitting of ACB. 7) Testing of the ACB for ON –OFF operation first at NO load and then at ON load including operation, manual charging system etc. | 1 | Job | - | - |
| 1.08 | Fixing of motor protection relays & over current & earth fault relay in incomer by doing necessary modification in panel door for fixing the sane and control wiring with coper wire & setting of various fault protection as per site requirements. | 4 | Jobs | - | - |
| 1.09 | Fixing of MCCB in existing panel by necessary modification in door etc. including required bus bar, links etc. & making cable connection | 1 | job | - | - |
| 1.1 | Insulation with heat shrinkable PVC sleeve/PVC tape throughout in red, yellow & blue color to identify three phases & black for neutral on panel bus bar | 1 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
BOQ_400370.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .