Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST AND ACCEPTABLE | |
| 2 | L2₹17.4 L+₹45,431 (2.68%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹17.8 L+₹88,079.80 (5.20%)Rejected-Finance MEGHA SADAN GAGANNAGAR CURTI PONDA GOA 403401 | PONDA | SOUTH GOA | GOA | 403401 | L3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹18.4 L
EMD Value
₹37,000
Closing Date
3 Jan 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JODHPUR
HQ CWE AF JODHPUR Opp Mosam Vibhag Airforce Chauraha , Ratanada Jodhpur (Raj)-342011
PROVN OF SERVO VOLTAGE STABILIZER FOR ADM AREA AT AFS JAIPUR
2024_MES_687231_1
89019/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) AF JAIPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
AGE (I) AF JAIPUR
₹37,000
Yes
27 Jan 2025
6 Dec 2024
6 Jan 2025
6 Dec 2024
3 Jan 2025
20 Dec 2024
Amount
Supply, installation, testing and commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-I) :1994, reaffirmation 2019 latest version). Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:- (a) Capacity :400 KVA (b) Type - Suitable for unbalanced load and unbalanced input. (c) Input Voltage- 360V-480V, Input Frequency-50Hz. (d) Output Voltage- Stabilized at any designed/desired voltage 415/+- 1%. (e) Rated Frequency- 50Hz. (f) Waveform destortion- Nil. (g) Response Time- Not to exceed 20 mili Second. (h) Sensitivity- (+/- 1%). (j) Rate of correctio- Not less than 6 V per Second between phase and neutral. (k) Efficiency- moer than 95%. (I) Type of load- Three Phase unbalanced type. (m) Metering- DIgital display Voltmeter/Ameter with multifunctional meter. (n) Operating Temprature- for inddor use upto max ambient temprature + 55 degree Celcius. (o) Class of insulation- Class F. (p) Mode of operation- Automatic/Manual. (q) Winding Temprature rise- Max 55 degree Celcius (10 degree above operating temprature). (r) Transformer oil- IS 335 marked. (s) Core-CRGO M4 grade/CRNO (Cold roll grain oriented)/Cold rolled non oriented. (v) auto transformer (variac)-100% copper wound Electrolytic grade. (u) losses- as per IS norms. (w) Power factor- not less than 0.95. (x) Protection- (i) Overload protections (ii) Short Circuit protections. (iii) High/Low voltage cutoff. (iv) Bypass arrangement in case of emergency. (v) Single phase sequence change/phase fail protection. (vi) Earth fault protection. (aa) Standered fitting and Accessories i.e Marking plate, lifting lugs, CI rollers, Earthing Terminals, cable box etc. Note : Specification given in this item shall be supersede the specification mentioned in Particular Specification.
Excavation in trenches not exc 1.5 mtrs wide & not exc 3 mtrs in depth for taking out/laying of pipes/cables etc & getting out in Hard/Dense soil complete all as specified and directed .
Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed .
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size. Outer/Inner dia of pipe 63/50 mm with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately). Rate for Inserting cable in pipe deemed to be included in quoted rate.
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size. Outer/Inner dia of pipe 50/38 mm with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately). Rate for Inserting cable in pipe deemed to be included in quoted rate.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core all as specified and as directed.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 630 Amps all as specified and as directed.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps.all as specified and as directed.
Supply installation and testing 3 phase and neutral, 415 volts factory made, Outdoor type, free standing, floor mounting, dust and vermin proof cubical type, LT panel fabricated from 3.15 mm thick ( minimum) CRCA sheet steel powder coated with Grey shade (RAL-7035) after seven tank process having thickness of 50-6- microns fully compartmentalized design with 4 Nos of busbars made of high conductivity 99.9% pure copper of ETP grade suitable for 400 amps pre-wired with suitable size of copper strip, including complete wiring and comprising of INCOMMING (a) MCCB 400 A FP 36KA with Microprocessor based release for O/C + S/C, spreader link and Ext Rotary Handle. (b ) Digital Ampere Meter (c) Indicating light RYB LED 230 V AC (d) Digital Volt meter (e) Control MCB 6A, 10 KA (f) CT 400/5A tape wound. OUTGOING (a) MCCB 320A,FP, 36 KA with TM release for O/C + S/C, spreader link and Ext Rotary Handle-01 Nos (b) MCCB 200A , FP, 25 KA with TM release for O/C + S/C, spreader link and Ext Rotary Handle-02 Nos. (c) MCB TPN 63 A,FP, 10 KA -03 Nos
M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, using galvanised iron strip 25×4mm as earthing lead connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. NOTE : (i) Earth resistance value should be less than 5 Ohms (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip.(iii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends , elbows etc. shall be deemed to be included in the quoted rate. (iv) excavation and earth work shall be measured and paid separately.
M&L for Earthing complete with Copper Plate electrode 60cm×60cm× 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, using Copper strip 20x3 mm as earthing lead connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. NOTE : (i) Earth resistance value should be less than 5 Ohms (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip.(iii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends , elbows etc. shall be deemed to be included in the quoted rate. (iv) excavation and earth work shall be measured and paid separately.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L for Cement concrete type C-2,1:3:6 (40 mm graded aggregate) 100 mm Thick complete all as spd and directed
M&L for Sand filling under floors/Blocks or in foundations including watering and consolidation
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade except tiles all as specified and as directed.
Bhawani Enterprises (BID ID -3203418)
M/S HARI CONSTRUCTION (BID ID -3205050)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .