Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC OPP CCS GARACHARMA PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹43.2 L+₹1.9 L (4.70%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹43.3 L+₹2.0 L (4.89%)Rejected-Finance NEAR PLAY GROUND BIRDLINE CALICUT POST PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹43.8 L+₹2.6 L (6.19%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹45.0 L+₹3.7 L (9.06%)Rejected-Finance 018 GROUND FLOOR LEKHRAJ ENCLAVE LEKHRAJ PANNA SECTOR 2 VIKAS NAGAR LUCKNOW UTTAR PRADESH 226022 | LUCKNOW | UTTAR PRADESH | 226022 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹42.7 L
EMD Value
₹85,500
Closing Date
18 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BRICHGUNJ
GE BRICHGUNJ, PORT BLAIR
SPL REPAIRS TO BLDG NO P164A (COOK HOUSE) AT BRICHGUNJ MILITARY STATION , PORT BLAIR
2023_MES_624969_1
8413A
Open Tender
Civil Works
Item Rate
180 days
Brichgunj
AS per NIT
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹85,500
Yes
3 Apr 2024
26 Oct 2023
21 Nov 2023
26 Oct 2023
18 Nov 2023
10 Nov 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness ( below or above ground level).
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for slab,shelves etc complete all as specified and directed
Demolition of Precast Concrete work built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed.
Taking down cement plaster of any description on brick or concrete surfaces etc including racking out joints, hacking for key, scrubbing down with water etc.
Dismantling floor, hearth or wall tiles including cement mortar bedding(but not backing) and removing serviceable tiles to stores and rubbish off the premises.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
M&L for Cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in floors, 40mm thick, laid in panels and finished even & smooth without using extra cement complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, approns and laid bedded and pointed in any mortar etc.
Use & waste of Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, for fair finished flat surfaces of concrete complete all as specified and directed.
M & L for RCC- M -30 Design Mix as in slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in,shelves and the like all as specified
S&F Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes all as specified and directed
M&L for Cement concrete 1:4:8 type D2 using 40mm graded stone aggregate in floors and paving, 75mm thick, laid in panels and finished even & smooth without using extra cement complete all as specified and directed.
M & L for coloured chequered cement concrete tiles 30 cm x 30cm x 25 mm thick, set and jointed neat cement slurry and pointed with With mixture of white & grey cement in equal proportions & no pigment, over and including 20 mm thick screed bed or bedding layer in cm 1:6 etc. complete all as specified and directed.
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.18 Sqm but n.exc 0.38 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment to match over 15mm thick screed bed in cement mortar (1:6) all as specified and directed.
All as per item No. 16 above but in skirting/dado laid over 10mm thick cement plaster in cement mortar 1:4 complete all as specified and directed.
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment to match over 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
All as per item No. 18 above but in skirting/dado laid over 10mm thick cement plaster in cement mortar 1:4 complete all as specified and directed.
M&L Glazed ceramic coloured / printed tiles (450X350mm) x6-7mm thick on vertical surfaces as in skirting/dado, set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles over 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
M&L pre-polished Machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
All as per item No. 18 above but in skirting/dado laid over 15mm thick cement plaster in cement mortar 1:4 complete all as specified
M&L pre-cast cement concrete block masonry Type C1 1:3:6 (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed
M&L for precast cement concrete block masonry with solid Type C1 1:3:6 (20mm graded aggregate as per IS 383) not exc. 10 cm in width and setting in CM 1:6 complete all as specified and directed
M&L for Rendering 10mm thick in cement mortar 1: 4 on faces of brick work or concrete surfaces, finished fair, even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 10mm thick in cement mortar 1: 6 on faces of brick work or concrete surfaces, finished fair, even and smooth without using extra cementcomplete all as specified and directed.
M&L for rendering 15mm thick in two coats on faces of brick work or concrete surfaces; first coat (rendering coat) of 10 mm thick in cement mortar 1: 6 and second coat (finishing coat) of 5 mm thick in cement mortar 1: 4 mixed with water proofing compound (water proofing compound to be measured separately as supply only) and finished even and smooth complete all as specified and directed.
Supply only integral water proof compound
M&L for Rendering 5 mm thick in cement mortar 1: 3 on faces of brick work or concrete surfaces, finished fair, even and smooth without using extra cementcomplete all as specified and directed.
M & L for preparing newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of putty complete all as specified and as directed.
M & L for complete removal of existing treatment on old plastered wall surfaces and applying two coats of oil bound distemper over a coat of resistant primer over a coat of putty complete all as specified and as directed.
M & L for preparing newly plastered ceiling surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of putty complete all as specified and as directed.
M & L for preparing old plastered ceiling surfaces and applying one coats of oil bound distemper over complete all as specified and as directed.
M&L Preparation of newly plastered surfaces of wall & applying Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over a coat of putty complete all as specified and directed.
M & L for complete removal of existing treatment on old plastered surfaces of walls and applying Two or more coatsof 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over a coat of putty complete all as specified and directed.
M&L for removing loose and broken concrete by chiselling/picking etc upto a depth of 10 to 20mm from floor/roof slab/chajjas and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles including necessary scaffolding etc and removal of debris to a distance not exceeding 50m complete all as specified and as directed.
M&L for application of high build polymer modified cement mortar (1:2.5) mixed with 3 kg SBR per bag of cement in ceiling surfaces 10 to 20mm thick in two layers surfaces over a coat of bonding agent Nito Bond SBR (1Ltr SBR + 1 ltr water + 3 kg cement) complete all as specified and directed.
M&L Preparing old steel/ Iron surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint over a coat of red oxide primer complete all specified and directed.
M&L Preparing new steel/ Iron surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all specified and directed.
M&L 40mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded aggregate) as in floorings , finished even and smooth without using extra cement complete all a specified and directed.
M&L 75 mm thick PCC 1:3:6 Type C-2 using 20mm crushed stone aggregate as in plinth protection and like finished even and smooth without using extra cement complete all a specified and directed.
S&F 38mm width of strip glass dividing strips, 3mm thick and inserted in position to confirm to design complete all a specified and directed.
S&F solid PVC door frame of sixe 50mmx47mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube in opening as per specification and drawing.
S&F factory made soilid panel PVC Door shutter 30mm thick (S type) consisting of frame made out MS frame shall be covered with heat moulded woodgrain printed PVC 'C' channel having PVC sheet stripof 20mm width stuck inside with solvent cement for stiles and woodgrain printed PVC sheet for top rail, lock rail, & bottom rail; Panneling of colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing.
M&L Painting two coats of synthetic enamel paint over a coat of red exide including preparation of new steel surfaces of any description over 10cm in width or girth not other wise described complete all as specified and directed.
Dismantling boarding of any description, fixed in any position with nails/screws.
Material and labour for false ceiling with aluminum grid work (Size of grid 600x600 mm) with 35 x 25 x 1.5 mm main tee and 25 x 25 x 1.4 mm cross tee and wall angle and suspended with 2mm dia GI wire hooked to roof with needful adjustment bolts at an interval of 1.20 m centre to centre staggered and board with Eco board decorative type size 600 x 600 x 4 mm thick finished with two coats of oil bound distemper over a coat of primer on exposed surfaces all as specified and directed
S & F Aluminium anodised (minimum anodisation is 50 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco). (Note:- Weight of various Aluminium sections handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only).
Supply and fix aluminium composite panel sheet of 3 to 4mm thick as in cupboards, wall cladding & false ceiling fixed on aluminium frame work with plastic strips (Double sided sticker) of suitable size of varying thickness of 10mm to 30mm excluding aluminium frame work applying adhesie over aluminium screws. The joints in panels shall be filled with weather proof sealant, the board shall be stuck with a layer of any colour high intensity reflective grade polymer sticker installed using epoxy adhesive complete all as specified and as directed.
Supply only 12 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination and fixed to aluminium frames complete all as specified and as directed
Supply only 5.5mm thick sheet glass, ordinary quality in squares exc 0.50 sq.m in each pane complete all a specified and directed.
Supply only aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixed with aluminium wire staples etc.complete all as specified and as directed
S&F in repairs aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixed with aluminium wire staples etc.complete all as specified and as directed
Supply only 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete all a specified and directed.
Supply only 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all a specified and directed.
Supply only Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all a specified and directed.
Supply only 125mm aluminium handles, cast type , anodised complete all a specified and directed.
S&F of 150mm Floor door stoper of aluminium alloy and tounge, anodised, with hard drawn steel sring, fixed in door complete all a specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all a specified and directed.
M & L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc and fixed by riveting or welding or with nut and bolts (including nuts and bolts) conforming to Fe-410-W grade E 251 Quality B complete all as specified and directed.
S &F MS work in wind ties for roof including securing bolts complete all a specified and directed.
Dismantling Plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings in roof covering all as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.5mm thickness, of colour as approved by GE, having tensile strength of 550 Mpa as in roof coverings/cladding to wall, etc, fixed with & including self tapping screws on angle frame complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.5mm thickness, of colour as approved by GE, having tensile strength of 550 Mpa as in ridges, etc, fixed with & including self tapping screws complete all as specified and directed.
Taking down eaves gutter and rain water pipes (of any size and pattern), incl all fittings and, heads, shoes, bends, swan-necks, etc incl cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories)
S&F 110mm bore PVC (SWR) soil, waste and vent pipe, in any length , with rubber joints, laid in trenches or in floors complete all as specified and directed.
S&F 110mm bore PVC (SWR) soil, waste and vent pipe, in any length , with rubber joints, fixed in walls complete all as specified and directed.
S&F 75mm bore PVC (SWR) soil, waste and vent pipe, in any length , with rubber joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) 110mm dia bend of any radius complete all as specified and directed.
S&F PVC (SWR) 110mm dia double T equal or unequal at Junctions of any radius complete all as specified and directed.
S&F PVC (SWR) 75mm dia bend of any radius complete all as specified and directed.
S&F PVC (SWR) 75mm dia double T equal or unequal at Junctions of any radius complete all as specified and directed.
S&F PVC (SWR) 75mm dia double T equal or unequal at Junctions of any radius complete all as specified and directed.
S&F in repairs 20mm bore Brass ball valve with polythene float and fly nut fixed in repairs complete all as specified and directed.
S&F in repairs 25mm bore Brass ball valve with polythene float and fly nut fixed in repairs complete all as specified and directed.
Taking up or down steel tubing 15mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down steel tubing 20mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down steel tubing 25mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20 mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 25 mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repairs PVC valve less, syphonic action type low level flushing cistern of capacity 10 Ltrs with inlet, ball valve, float and handle and fixed to IWC on existing brackets, complete all as specified and directed.
S&F in repair vitreous china washbasin, white, flat back, size 550 x 400mm, fixed on existing brackets incl 32mm bore MS CP waste coupling complete all as specified and directed.
S&F in repair viterous china squartting pan orrisa pattern , size 580x 440mm white, interged foot rest including connection to trap and to flush pipe, anti syphonic pipe etc complete making good to floor complete all as specified and directed.
S&F in repairs Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&F in repairs Vitreous china urinal partition white of size 310x700 mm and Urinal partitions slabs terminating about 40cm above floor line, complete all as specified and directed.
S&F CI floor traps 110mm bore with stainless steel grating including jointing to waste pipe in cement concrete 1:2:4 type B-1 complete all as specified and directed.
S&F Rotational moulded (three layered, ISI marked) polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity including PVC cover, hoisted and fixed in position including connecting up pipes complete all as specified and directed.
S&F Rotational moulded (three layered, ISI marked) polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity including PVC cover, hoisted and fixed in position including connecting up pipes complete all as specified and directed.
S&F 25mm dia aluminum powder coated best quality curtain rails with fixing brackets in both ends complete all as specified and as directed.
S&F in repair decorative globes for curtain rails to be fixed at both end complete all as specified and as directed.
S&F in repair Sinks with out drainage board made of stainless steel 1mm thick for kitchen with plug washers, waste pipe and coupling including bedding in cement mortar, two coat iron fixing bracket of required size and connecting union to pipe over all size 1040mm x 510mm bowl size 510mm x 405 mm x 203mm, complete all as specified and as directed.
S&F in repair Waste pipe any size suitable for wash basin urinal and sink complete all as specified and directed
S & F in repairs 15 mm dia bore fancy type pillar taps ,cast copper alloy chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with capstan head, screwed for iron pipes or for union and fixed, complete all as specified and as directed.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia D-type, 60cm long between flange complete all as specified and as directed.
Supply only PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S&F in repair 15mm bore stop valve/angle valve cast copper alloy chromium plated fancy type screwed down, high pressure, with crutch or butter fly handles fixed in repairs complete all as specified and as directed.
S&F in repair Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe 20mm bore complete all as specified and as directed.
S&F in repair Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe 25mm bore complete all as specified and as directed.
S&F in repair 15mm Bib taps chromium, plated cast copper alloy, fancy type with cruttch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed 15mm bore complete all as specified and as directed.
S&F in repairs two way bib cock, brass CP mixture for mixing hot & cold water complete of make Jaquar Cat Part No ARI 39041 or equivalent complete all as specified and as directed.
S&F in repairs chromium plated hand shower (health faucet) 1 meter with PVC tube with wall hook complete all as specified and directed.. Make Jaquar Cat No ALD-CHR-593 or equivalent.
M&L for PCC 1:2:4 type B1 (20mm graded aggregate) as in levelling course for slope correction of existing RCC roof surfaces including cleaning the roof surfaces and removing existing APP based membrane removing all foreign materials by wire brushes/ brooms/ water jet as specified.
M & L for water proofing treatment with the following specifications including taking down existing roof treatment including cement screed/plaster of any description and cleaning with water and scrubbing and disposing off the rubbish outside the premises, complete all as specified and as per manufacturers instructions:- (i) Rendering 10mm thick in CM 1:4 on fair faces of brick or concrete wall surfaces finished smooth and even mixed with water proofing compound @ 3% by weight of cement or as per manufacturers instructions complete all as specified and as directed. (Note:- Water proofing compound shall be measured and paid separately) (ii) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. (iii) Laying Aquashield membrane weighing 3to 4Kg/sqm, with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iii) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M& L for decco grill of aluminium section 8 to 10mm thick complete all as specified and directed.
Taking down carefully aluminium point wiring (light, fan, socket or power) DBs complete offering credit, making good disturbed surfaces of walls, floors, etc, all as specified and as directed.
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, etc., all as specified and as directed for one light point/exfans controlled by one one way switch.
All as per item No. 112 above but for one fan point controlled by one 5 Amps switch with 1.5 sq mm copper conductor cable complete all as specified and as directed.
All as per item No. 112 above but for 5 Amps switch socket point on the same board controlled by one switch complete all as specified and as directed.
All as per item No. 112 above but for 3 pin switch socket outlet point 5 amps on independent board.
Supply and fix switch piano flush button single pole oneway 5 amp complete all as specified and as directed.
Supply and fix switch socket combination 3 & 2 pin (multi pin) 5 amp flush type complete all as specified and as directed.
All as per item No 112 above but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed.
Supply and fix switch socket outlet multipurpose 3 pin 15 and 5 amp controlled by one switch, flush type complete all as specified and as directed.
Supply and fix ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and as directed.
Supply and fix fan speed regulator, electronic suitable socket type for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed.
Supply and fixing energy efficient LED Smart bright batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
S & F LED mirror light fitting 1 x 10 Watt provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable mirror light fitting of any wattage, complete all as specified and directed.
S&F 36 W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
Dismantling and taking down ceiling fan &exhaust fans and refixing/connecting up including provision of cable from ceiling rose or connector to fan and Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as directed
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB complete all as specified and as directed.
Supply and fix in repair MCB single pole 240 volts, 6 to 32 amps "C" series complete all as specified and as directed.
Supply and fix single pole and netural 240 Volts 6 To 32 amps complete all as specified and as directed.
Supply and fix sheet metal enclosures Loadline vertical distribution board TPN, 4 ways 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs and in and including 63A MCCB ,16KA as incomming complete all as specified and as directed including taking down old MCB DBs complete including cutting chases pinning in making good to facings where required and pointing in cement mortar 1:3 ends of edges of landing,steps, cills sunsades,shelves,lintels,etc and cutting for concealed conduit wiring etc and making good,cutting not exc 10 cm girth in brick wall complete all as specified.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
M & L in repairs for sub main wiring complete with three runs of 4 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 4 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Three runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
Supply only Industrial type sheet metal enclosure with metal clad plug and socket single phase with a two pin and earth plug & socket complete rated 240V, 30 Amps capacity controlled by and including One No 32 Amps MCB SP 10 KA rupturing capacity complete all as specified and directed.
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 4 C x 16 sq mm
Supply and filling pulverized stone dust to the full width of trenches for protection of cables including spreading and punning down including watering consolidation complete all as specified. Note : Thickness of stone dust will be paid after cushioning after punning.
Supplying and laying unreinforced Precast Cement Concrete Cable Covers, Class LV, Type - 1, Flat, size 250mm X 150mm X 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface incl taking down old cover complete all as specified and as directed.
S& F steel water tubes light grade (ISI marked) galvanised with all fittings supporting for ceiling fans in ceilings of size 50 mm bore pipe, complete, all as specified and as directed.
Supply and fix 25 mm bore GI tubing medium grade laid in trenches / floor or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out complete all as specified and directed
Supply and fix 25 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, complete all as specified and as directed
M&L for cutting existing 50mm GI line and making branch connection of 40 mm dia GI line complete all as specified and directed
Supply and fix 25 mm bore Gun Metal gate valve with iron wheel head ISI Marked screwed both ends suitable for GI tubing complete all as specifed and directed
M/s Prem Enterprise
M/s Saina Enterprises
M/s Kamal Electrical
SK ENTERPRISES
Bismi Builders & Enterprises
P Babu
Nirman Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .